Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wavelet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Radiation Anomaly Detection Algorithms for Field-Acquired Gamma Energy Spectra

The Remote Sensing Laboratory (RSL) is developing a tactical, networked radiation detection system that will be agile, reconfigurable, and capable of rapid threat assessment with a high degree of fidelity and certainty. Our design is driven by the needs of users such as law enforcement personnel who must make decisions by evaluating threat signatures in urban settings. The most efficient tool available to identify the nature of the threat object is real-time gamma spectroscopic analysis, as it is fast and has a very low probability of producing false positive alarm conditions. Urban radiological searches are inherently challenged by the rapid and large spatial variation of background gamma radiation, the presence of benign radioactive materials in terms of the normally occurring radioactive materials (NORM), and shielded and/or masked threat sources. Multiple spectral anomaly detection algorithms have been developed by national laboratories and commercial vendors. For example, the Gamma Detector Response and Analysis Software (GADRAS) a one-dimensional deterministic radiation transport software capable of calculating gamma ray spectra using physics-based detector response functions, was developed at Sandia National Laboratories. The nuisance-rejection spectral comparison ratio anomaly detection algorithm (or N-SCRAD), developed at Pacific Northwest National Laboratory, uses spectral comparison ratios to detect deviation from benign medical and NORM radiation source and can work in spite of strong presence of NORM and or medical sources. RSL has developed its own wavelet-based gamma energy spectral anomaly detection algorithm called WAVRAD. Test results and relative merits of these different algorithms will be discussed and demonstrated.

networked sensor, gamma spectroscopy, false alarm ↗

Networked Gamma Radiation System for Tactical Deployment

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2" × 4" × 16" sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmonic enhancement of thin-film solar cells using gold-black coatings

Coatings of conducting gold-black nano-structures on commercial thin-film amorphous-silicon solar cells enhance the short-circuit current by 20% over a broad spectrum from 400 to 800 nm wavelength. The efficiency, i.e. the ratio of the maximum electrical output power to the incident solar power, is found to increase 7% for initial un-optimized coatings. Metal blacks are produced cheaply and quickly in a low-vacuum process requiring no lithographic patterning. The inherently broad particle-size distribution is responsible for the broad spectrum enhancement in comparison to what has been reported for mono-disperse lithographically deposited or self-assembled metal nano-particles. Photoemission electron microscopy reveals the spatial-spectral distribution of hot-spots for plasmon resonances, where scattering of normally-incident solar flux into the plane increases the effective optical path in the thin film to enhance light harvesting. Efficiency enhancement is correlated with percent coverage and particle size distribution, which are determined from histogram and wavelet analysis of scanning electron microscopy images. Electrodynamic simulations reveal how the gold-black particles scatter the radiation and locally enhance the field strength.

14 SOLAR ENERGY↗

B-spline active rays segmentation of microcalcifications in mammography

Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation to identify microcalcification contour point estimates in a coarse-to-fine strategy at two levels of analysis. An iterative region growing method is used to delineate the final microcalcification contour curve, with pixel aggregation constrained by the microcalcification contour point estimates. A radial gradient-based method was also implemented for comparative purposes. The methods were tested on a dataset consisting of 149 mainly pleomorphic microcalcification clusters originating from 130 mammograms of the DDSM database. Segmentation accuracy of both methods was evaluated by three radiologists, based on a five-point rating scale. The radiologists' average accuracy ratings were 3.96{+-}0.77, 3.97{+-}0.80, and 3.83{+-}0.89 for the proposed method, and 2.91{+-}0.86, 2.10{+-}0.94, and 2.56{+-}0.76 for the radial gradient-based method, respectively, while the differences in accuracy ratings between the two segmentation methods were statistically significant (Wilcoxon signed-ranks test, p<0.05). The effect of the two segmentation methods in the classification of benign from malignant microcalcification clusters was also investigated. A least square minimum distance classifier was employed based on cluster features reflecting three morphological properties of individual microcalcifications (area, length, and relative contrast). Classification performance was evaluated by means of the area under ROC curve (A{sub z}). The area and length morphologic features demonstrated a statistically significant (Mann-Whitney U-test, p<0.05) higher patient-based classification performance when extracted from microcalcifications segmented by the proposed method (0.82{+-}0.06 and 0.86{+-}0.05, respectively), as compared to segmentation by the radial gradient-based method (0.71{+-}0.08 and 0.75{+-}0.08). The proposed method demonstrates improved segmentation accuracy, fulfilling human visual criteria, and enhances the ability of morphologic features to characterize microcalcification clusters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks when compared to the previous one. Specifically, at 60%, 65%, and 70% per-mammogram sensitivity, the new CAD system achieves 0.50, 0.68, and 0.92 FP marks per mammogram, whereas at 70%, 75%, and 80% per-case sensitivity it achieves 0.37, 0.48, and 0.71 FP marks per mammogram, respectively. Conversely, at the same sensitivities, the previous CAD system reached 0.71, 0.87, and 1.15 FP marks per mammogram, and 0.57, 0.73, and 0.92 FPs per mammogram. Also, statistical significance of the difference between the two per-mammogram and per-case FROC curves is demonstrated by the p-value<0.001 returned by jackknife FROC analysis performed on the two CAD systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Smoothing of respiratory motion traces for motion-compensated radiotherapy

Purpose: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera ''as is''. Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method. Methods: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS{sub 2} algorithms. Results: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS{sub 2}) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS{sub 2} and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal. Conclusions: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18C-09: Mammogram Surveillance Using Texture Analysis for Breast Cancer Patients After Radiation Therapy

Purpose: To study the feasibility of applying cancer risk model established from treated patients to predict the risk of recurrence on follow-up mammography after radiation therapy for both ipsilateral and contralateral breast. Methods: An extensive set of textural feature functions was applied to a set of 196 Mammograms from 50 patients. 56 Mammograms from 28 patients were used as training set, 44 mammograms from 22 patients were used as test set and the rest were used for prediction. Feature functions include Histogram, Gradient, Co-Occurrence Matrix, Run-Length Matrix and Wavelet Energy. An optimum subset of the feature functions was selected by Fisher Coefficient (FO) or Mutual Information (MI) (up to top 10 features) or a method combined FO, MI and Principal Component (FMP) (up to top 30 features). One-Nearest Neighbor (1-NN), Linear Discriminant Analysis (LDA) and Nonlinear Discriminant Analysis (NDA) were utilized to build a risk model of breast cancer from the training set of mammograms at the time of diagnosis. The risk model was then used to predict the risk of recurrence from mammogram taken one year and three years after RT. Results: FPM with NDA has the best classification power in classifying the training set of the mammogram with lesions versus those without lesions. The model of FPM with NDA achieved a true positive (TP) rate of 82% compared to 45.5% of using FO with 1-NN. The best false positive (FP) rates were 0% and 3.6% in contra-lateral breast of 1-year and 3-years after RT, and 10.9% in ipsi-lateral breast of 3-years after RT. Conclusion: Texture analysis offers high dimension to differentiate breast tissue in mammogram. Using NDA to classify mammogram with lesion from mammogram without lesion, it can achieve rather high TP and low FP in the surveillance of mammogram for patient with conservative surgery combined RT.

60 APPLIED LIFE SCIENCES↗

WE-E-17A-02: Predictive Modeling of Outcome Following SABR for NSCLC Based On Radiomics of FDG-PET Images

Purpose: This study aims to develop predictive models of patient outcome by extracting advanced imaging features (i.e., Radiomics) from FDG-PET images. Methods: We acquired pre-treatment PET scans for 51 stage I NSCLC patients treated with SABR. We calculated 139 quantitative features from each patient PET image, including 5 morphological features, 8 statistical features, 27 texture features, and 100 features from the intensity-volume histogram. Based on the imaging features, we aim to distinguish between 2 risk groups of patients: those with regional failure or distant metastasis versus those without. We investigated 3 pattern classification algorithms: linear discriminant analysis (LDA), naive Bayes (NB), and logistic regression (LR). To avoid the curse of dimensionality, we performed feature selection by first removing redundant features and then applying sequential forward selection using the wrapper approach. To evaluate the predictive performance, we performed 10-fold cross validation with 1000 random splits of the data and calculated the area under the ROC curve (AUC). Results: Feature selection identified 2 texture features (homogeneity and/or wavelet decompositions) for NB and LR, while for LDA SUVmax and one texture feature (correlation) were identified. All 3 classifiers achieved statistically significant improvements over conventional PET imaging metrics such as tumor volume (AUC = 0.668) and SUVmax (AUC = 0.737). Overall, NB achieved the best predictive performance (AUC = 0.806). This also compares favorably with MTV using the best threshold at an SUV of 11.6 (AUC = 0.746). At a sensitivity of 80%, NB achieved 69% specificity, while SUVmax and tumor volume only had 36% and 47% specificity. Conclusion: Through a systematic analysis of advanced PET imaging features, we are able to build models with improved predictive value over conventional imaging metrics. If validated in a large independent cohort, the proposed techniques could potentially aid in identifying patients who might benefit from adjuvant therapy.

60 APPLIED LIFE SCIENCES↗

A two-stage method for microcalcification cluster segmentation in mammography by deformable models

Purpose: Segmentation of microcalcification (MC) clusters in x-ray mammography is a difficult task for radiologists. Accurate segmentation is prerequisite for quantitative image analysis of MC clusters and subsequent feature extraction and classification in computer-aided diagnosis schemes. Methods: In this study, a two-stage semiautomated segmentation method of MC clusters is investigated. The first stage is targeted to accurate and time efficient segmentation of the majority of the particles of a MC cluster, by means of a level set method. The second stage is targeted to shape refinement of selected individual MCs, by means of an active contour model. Both methods are applied in the framework of a rich scale-space representation, provided by the wavelet transform at integer scales. Segmentation reliability of the proposed method in terms of inter and intraobserver agreements was evaluated in a case sample of 80 MC clusters originating from the digital database for screening mammography, corresponding to 4 morphology types (punctate: 22, fine linear branching: 16, pleomorphic: 18, and amorphous: 24) of MC clusters, assessing radiologists’ segmentations quantitatively by two distance metrics (Hausdorff distance—HDIST{sub cluster}, average of minimum distance—AMINDIST{sub cluster}) and the area overlap measure (AOM{sub cluster}). The effect of the proposed segmentation method on MC cluster characterization accuracy was evaluated in a case sample of 162 pleomorphic MC clusters (72 malignant and 90 benign). Ten MC cluster features, targeted to capture morphologic properties of individual MCs in a cluster (area, major length, perimeter, compactness, and spread), were extracted and a correlation-based feature selection method yielded a feature subset to feed in a support vector machine classifier. Classification performance of the MC cluster features was estimated by means of the area under receiver operating characteristic curve (Az ± Standard Error) utilizing tenfold cross-validation methodology. A previously developed B-spline active rays segmentation method was also considered for comparison purposes. Results: Interobserver and intraobserver segmentation agreements (median and [25%, 75%] quartile range) were substantial with respect to the distance metrics HDIST{sub cluster} (2.3 [1.8, 2.9] and 2.5 [2.1, 3.2] pixels) and AMINDIST{sub cluster} (0.8 [0.6, 1.0] and 1.0 [0.8, 1.2] pixels), while moderate with respect to AOM{sub cluster} (0.64 [0.55, 0.71] and 0.59 [0.52, 0.66]). The proposed segmentation method outperformed (0.80 ± 0.04) statistically significantly (Mann-Whitney U-test, p < 0.05) the B-spline active rays segmentation method (0.69 ± 0.04), suggesting the significance of the proposed semiautomated method. Conclusions: Results indicate a reliable semiautomated segmentation method for MC clusters offered by deformable models, which could be utilized in MC cluster quantitative image analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-R-24: Identifying Prognostic Imaging Biomarkers in Early Stage Lung Cancer Using Radiomics

Purpose: Patients diagnosed with early stage lung cancer have favorable outcomes when treated with surgery or stereotactic radiotherapy. However, a significant proportion (∼20%) of patients will develop metastatic disease and eventually die of the disease. The purpose of this work is to identify quantitative imaging biomarkers from CT for predicting overall survival in early stage lung cancer. Methods: In this institutional review board-approved HIPPA-compliant retrospective study, we retrospectively analyzed the diagnostic CT scans of 110 patients with early stage lung cancer. Data from 70 patients were used for training/discovery purposes, while those of remaining 40 patients were used for independent validation. We extracted 191 radiomic features, including statistical, histogram, morphological, and texture features. Cox proportional hazard regression model, coupled with the least absolute shrinkage and selection operator (LASSO), was used to predict overall survival based on the radiomic features. Results: The optimal prognostic model included three image features from the Law’s feature and wavelet texture. In the discovery cohort, this model achieved a concordance index or CI=0.67, and it separated the low-risk from high-risk groups in predicting overall survival (hazard ratio=2.72, log-rank p=0.007). In the independent validation cohort, this radiomic signature achieved a CI=0.62, and significantly stratified the low-risk and high-risk groups in terms of overall survival (hazard ratio=2.20, log-rank p=0.042). Conclusion: We identified CT imaging characteristics associated with overall survival in early stage lung cancer. If prospectively validated, this could potentially help identify high-risk patients who might benefit from adjuvant systemic therapy.

60 APPLIED LIFE SCIENCES↗

Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study

Purpose: Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. Methods: The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background. Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Results: Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. Conclusions: MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.

60 APPLIED LIFE SCIENCES↗

Analysis of the Spectral Composition of Fluorescence from Laser-Excited Cold Atomic Clouds

A consistent quantum approach is used to calculate the signal of fluorescence from a laser-excited cold atomic ensemble. The possibility of analyzing the spectral composition of this nonstationary signal is investigated. Application of wavelet transforms is shown to be a very efficient method that allows achieving a good spectral or temporal resolution, depending on specific problem. On the basis of this approach, the spectral composition of fluorescence and its dynamics after excitation are studied. The spectral properties of the secondary emission of the ensemble are compared for different directions and polarizations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nonlinear Thomson scattering of an ultrashort laser pulse

The nonlinear scattering of an ultrashort laser pulse by free electrons is considered. The pulse is described in the 'Mexican hat' wavelet basis. The equation of motion for a charged particle in the field of a plane electromagnetic wave has an exact solution allowing, together with the instant spectrum approximation, the calculation of the intensity of nonlinear Thomson scattering for a high-intensity laser pulse. The spectral distribution of scattered radiation for the entire pulse duration is found by integrating with respect to time. The maximum of the emission spectrum of a free electron calculated in 10{sup 19}-10{sup 21} W/cm{sup 2} fields lies in the UV spectral region between 3 and 12 eV. A part of the continuous spectrum achieves high photon energies. One percent of the scattered energy for the field intensity 10{sup 20} W/cm{sup 2} is concentrated in the range h{omega} > 2.7 Multiplication-Sign 10{sup 2} eV, for a field intensity of 10{sup 21} W/cm{sup 2} in the range h{Omega} > 7.9 Multiplication-Sign 10{sup 2} eV, and for an intensity of 10{sup 22} W/cm{sup 2} in the range h{Omega} > 2.45 Multiplication-Sign 10{sup 5} eV. These results allow us to estimate nonlinear scattering as a source of hard X-rays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Situ Summarization with VTK-m

Summarization and compression at current and future scales requires a framework for developing and benchmarking algorithms. We present a framework created by integrating existing, production-ready projects and provide timings of two particular algorithms that serve as exemplars for summarization: a wavelet-based data reduction filter and a generator for creating image-like databases of extracted features (isocontours in this case). Both support browser-based, post-hoc, interactive visualization of the summary for decision-making. A study of their weak-scaling on a distributed multi-GPU system is included in this article.

97 MATHEMATICS AND COMPUTING↗

Libra: Scalable Load Balance Analysis

Libra is a tool for scalable analysis of load balance data from all processes in a parallel application. Libra contains an instrumentation module that collects model data from parallel applications and a parallel compression mechanism that uses distributed wavelet transforms to gather load balance model data in a scalable fashion. Data is output to files, and these files can be viewed in a GUI tool by Libra users. The GUI tool associates particular load balance data with regions for code, emabling users to view the load balance properties of distributed "slices" of their application code.

Source record↗

Convective and turbulent motions in non-precipitating Cu. Part 1: Method of separation of convective and turbulent motions

Atmospheric motions in clouds and cloud surroundings have a wide range of scales, from several kilometers to centimeters. These motions have different impacts on cloud dynamics and microphysics. Larger-scale motions (hereafter referred to as convective motions) are responsible for mass transport over distances comparable with cloud scale, while motions of smaller scales (hereafter referred to as turbulent motions) are stochastic and responsible for mixing and cloud dilution. This distinction substantially simplifies the analysis of dynamic and microphysical processes in clouds. The present research is Part I of the study aimed at describing the method for separating the motion scale into a convective component and a turbulent component. An idealized flow is constructed, which is a sum of an initially prescribed field of the convective velocity with updrafts in the cloud core and downdrafts outside the core, and a stochastic turbulent velocity field obeying the turbulent properties, including the -5/3 law and the 2/3 structure function law. A wavelet method is developed allowing separation of the velocity field into the convective and turbulent components, with parameter values being in a good agreement with those prescribed initially. The efficiency of the method is demonstrated by an example of a vertical velocity field of a cumulus cloud simulated using the System for Atmospheric Modeling (SAM) with bin microphysics and resolution of 10 m. It is shown that vertical velocity in clouds indeed can be represented as a sum of convective velocity (forming zone of cloud updrafts and subsiding shell) and a stochastic velocity obeying laws of homogeneous and isotropic turbulence.

54 ENVIRONMENTAL SCIENCES↗

Convective and Turbulent Motions in Nonprecipitating Cu. Part II: LES Simulated Cloud Represented by a Starting Plume

The dynamic structure of a small trade wind cumulus (Cu) is analyzed using a novel approach. Cu developing in a shear-free environment is simulated by 10-m-resolution LES model with spectral bin microphysics. The aim is to clarify the dynamical nature of cloud updraft zone (CUZ) including entrainment and mixing in growing Cu. The validity of concept stating that a cloud at developing state can be represented by a parcel or a jet is tested. To investigate dynamical entrainment in CUZ performed by motions with scales larger than the turbulence scales, the modeled fields of air velocity were filtered by wavelet filter that separated convective motions from turbulent ones. Two types of objects in developing cloud were investigated: small volume ascending at maximal velocity (point parcel) and CUZ. It was found that the point parcel representing the upper part of cloud core is adiabatic. The motion of the air in this parcel ascending from cloud base determines cloud-top height. The top-hat (i.e., averaged) values of updraft velocity and adiabatic fraction in CUZ are substantially lower than those in the point parcel. Evaluation of the terms in the dynamical equation typically used in 1D cloud parcel models show that this equation can be applied for calculation of vertical velocities at the developing stage of small Cu, at least up to the heights of the inversion layer. Dynamically, the CUZ of developing cloud resembles the starting plume with the tail of nonstationary jet. Both the top-hat vertical velocity and buoyancy acceleration linearly increase with the height, at least up to the inversion layer. An important finding is that lateral entrainment of convective (nonturbulent) nature has a little effect on the top-hat CUZ velocity and cannot explain the vertical changes of conservative variables qt and θl. In contrast, entrained air lifting inside CUZ substantially decreases top-hat liquid water content and its adiabatic fraction. Possible reasons of these effects are discussed.

54 ENVIRONMENTAL SCIENCES↗