Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tuning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A frequency doubled pressure-tunable oscillator-amplifier dye laser system

A tunable high-repetition-rate oscillator-amplifier dye-laser system is reported. The dye laser described was longitudinally pumped with the second harmonic of a Nd-YAG laser operating at 10 Hz. Using three Faraday-Perot etalons and pressure tuning, a maximum fundamental output power of the order of 6 MW with a corresponding spectral width of less than 0.003 nm at 564 nm was obtained. The fundamental at 564 nm was frequency doubled to give a maximum power level of 0.6 MW of second-harmonic output power with a spectral width less than 0.0015 nm at 282 nm. Frequency stability could be maintained to within approximately 15% of the line-width.

Moriarty, A.↗

Evaluation of the dual differential radiometer for remote sensing of sediment and chlorophyll in turbid waters

The dual differential radiometer (DDR) was tested to determine its capability for measuring suspended sediment and chlorophyll in turbid waters. Measurements were obtained from a boat dock and from a helicopter with combinations of sample and reference filters with peak transmissions at various wavelengths. Water samples were taken concurrently and were analyzed for light scattering, particle count, and total chlorophyll. Least-squares estimates of the linear relationship between DDR output and the water parameters yielded correlation coefficients of less than 0.7. Under the turbid water conditions of the present tests, the DDR did not accurately measure either suspended sediment or chlorophyll. A precise knowledge of the spectral signatures of various pollutants might enable appropriate filters to be selected for tuning the DDR to monitor a particular pollutant.

Witte, W. G.↗

Sequence characterization of 5S ribosomal RNA from eight gram positive procaryotes

Complete nucleotide sequences are presented for 5S rRNA from Bacillus subtilis, B. firmus, B. pasteurii, B. brevis, Lactobacillus brevis, and Streptococcus faecalis, and 5S rRNA oligonucleotide catalogs and partial sequence data are given for B. cereus and Sporosarcina ureae. These data demonstrate a striking consistency of 5S rRNA primary and secondary structure within a given bacterial grouping. An exception is B. brevis, in which the 5S rRNA sequence varies significantly from that of other bacilli in the tuned helix and the procaryotic loop. The localization of these variations suggests that B. brevis occupies an ecological niche that selects such changes. It is noted that this organism produces antibiotics which affect ribosome function.

Woese, C. R.↗

A distributed computing approach to mission operations support

Computing mission operation support includes orbit determination, attitude processing, maneuver computation, resource scheduling, etc. The large-scale third-generation distributed computer network discussed is capable of fulfilling these dynamic requirements. It is shown that distribution of resources and control leads to increased reliability, and exhibits potential for incremental growth. Through functional specialization, a distributed system may be tuned to very specific operational requirements. Fundamental to the approach is the notion of process-to-process communication, which is effected through a high-bandwidth communications network. Both resource-sharing and load-sharing may be realized in the system.

Larsen, R. L.↗

Solar energy microclimate as determined from satellite observations

A method is presented for determining solar insolation at the earth's surface using satellite broadband visible radiance and cloud imagery data, along with conventional in situ measurements. Conventional measurements are used to both tune satellite measurements and to develop empirical relationships between satellite observations and surface solar insolation. Cloudiness is the primary modulator of sunshine. The satellite measurements as applied in this method consider cloudiness both explicitly and implicitly in determining surface solar insolation at space scales smaller than the conventional pyranometer network.

Vonder Haar, T. H.↗

Twisted shield-pair transmission line

Lightweight cable forms balanced transmission line and replaces costlier coaxial cables for multiplex-signal transmission. Cable is fabricated with carefully-controlled electrical characteristics and functions without tuning networks at frequencies up to 10 MHz.

Lind, W. N.↗

A high-temperature wideband pressure transducer

A condenser microphone AM carrier system, which has been developed to measure pressure fluctuations at elevated temperatures, consists of the following components: a condenser microphone designed for operation at elevated temperatures; existing carrier electronics developed under two previous research grants but adapted to meet present requirements; a 6 m cable operating as a half-wavelength transmission line between the microphone and carrier electronics; and a voltage-controlled oscillator used in a feedback loop for automatic tuning control. Both theoretical and practical aspects of the development program are considered. The three predominant effects of temperature changes are changes in the membrane-backplate gap, membrane tension, and air viscosity. The microphone is designed so that changes in gap and membrane tension tend to have compensating effects upon the microphone sensitivity.

Zuckerwar, A. J.↗

A unified acquisition system for acoustic data

A multichannel, acoustic AM carrier system was developed for a wide variety of applications, particularly for aircraft noise and sonic boom measurements. Each data acquisition channel consists of a condenser microphone, an acoustic signal converter, and a Zero Drive amplifier, along with peripheral supporting equipment. A control network insures continuous optimal tuning of the converter and permits remote calibration of the condenser microphone. With a 12.70-mm (1/2-in.) condenser microphone, the converter/Zero Drive amplifier combination has a frequency response from 0 Hz to 20 kHz (-3 db), a dynamic range exceeding 70 db, and a minimum noise floor of 50 db ref. 20 micro Pa) in the band 22.4 Hz to 22.4 kHz. The system requires no external impedance matching networks and is insensitive to cable length, at least up to 900 m (3,000 ft). System gain varies only + or - 1 db over the temperature range 4 to 54 C (40 to 130 F). Adapters are available to accommodate 23.77-mm (1-in.) and 6.35-mm (1/4-in.) microphones and to provide 30-db attenuation. A field test to obtain the acoustical time history of a helicopter flyover proved successful.

Zuckerwar, A. J.↗

The application of digital computers to near-real-time processing of flutter test data

Procedures used in monitoring, analyzing, and displaying flight and ground flutter test data are presented. These procedures include three digital computer programs developed to process structural response data in near real time. Qualitative and quantitative modal stability data are derived from time history response data resulting from rapid sinusoidal frequency sweep forcing functions, tuned-mode quick stops, and pilot induced control pulses. The techniques have been applied to both fixed and rotary wing aircraft, during flight, whirl tower rotor systems tests, and wind tunnel flutter model tests. An hydraulically driven oscillatory aerodynamic vane excitation system utilized during the flight flutter test programs accomplished during Lockheed L-1011 and S-3A development is described.

Hurley, S. R.↗

Acoustic cavity technology for high performance injectors

The feasibility of damping more than one mode of rocket engine combustion instability by means of differently tuned acoustic cavities sharing a common entrance was shown. Analytical procedures and acoustic modeling techniques for predicting the stability behavior of acoustic cavity designs in hot firings were developed. Full scale testing of various common entrance, dual cavity configurations, and subscale testing for the purpose of obtaining motion pictures of the cavity entrance region, to aid in determining the mechanism of cavity damping were the two major aspects of the program.

Source record↗

Acoustic tests of augmentor wing model

Acoustic and aerodynamic data were obtained for a full-scale section of an augmentor wing. Features of the design included a single-row, multielement nozzle array and acoustically tuned panels placed on the interior surfaces of the augmentor. When the data were extrapolated to a 91,000-kilogram aircraft, the calculated sideline perceived noise levels were approximately the same for either the takeoff or approach condition.

Goodykoontz, J. H.↗

Isotope separation using metallic vapor lasers

The isotope U235 is separated from a gasified isotope mixture of U235 and U238 by selectively exciting the former from the ground state utilizing resonant absorption of radiation from precisely tuned lasers. The excited isotope is then selectively ionized by electron bombardment. It then is separated from the remaining isotope mixture by electromagnetic separation.

Russell, G. R.↗

Direct reading inductance meter

A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.

Kolby, R. B.↗

Upgrading and testing program for narrow band high resolution planetary IR imaging spectrometer

An imaging spectrometer, intended primarily for observations of the outer planets, which utilizes an acoustically tuned optical filter (ATOF) and a charge coupled device (CCD) television camera was modified to improve spatial resolution and sensitivity. The upgraded instrument was a spatial resolving power of approximately 1 arc second, as defined by an f/7 beam at the CCD position and it has this resolution over the 50 arc second field of view. Less vignetting occurs and sensitivity is four times greater. The spectral resolution of 15 A over the wavelength interval 6500 A - 11,000 A is unchanged. Mechanical utility has been increased by the use of a honeycomb optical table, mechanically rigid yet adjustable optical component mounts, and a camera focus translation stage. The upgraded instrument was used to observe Venus and Saturn.

Wattson, R. B.↗

Atmospheric temperature profiles derived through the inversion of a system of first order differential equations

Generation of vertical temperatures profiles from remotely sensed atmospheric radiance data is described as an analogous communications system. The radiative transport characteristics of the atmosphere encodes the continuous temperature profile into an 'n' element vector where 'n' is the number of channels in the satellite instrument. The temperature profile is a message transmitted from station A to station B and the link is the satellite instrument. At station B the decoder reproduces a continuous function which is the best estimate of the message encoded at station A. It is shown that the decoder must operate in a tuned mode where the parameters used in the encoder precisely determine the decoder parameters, and that the characteristics of the total message block must be given by a set of decoder constraints

Gatlin, J. A.↗

Geometry and properties of the plasma in a quadrupole ion pump

The diameter of the plasma in a quadrupole ionization gauge and quadrupole ion pump has been measured as a function of pressure. The radio-frequency quadrupole systems are tuned in such a way that electrons remain on stable trajectories in the center of the tube. Being emitted at one end, the electrons encounter an inverted field at the other end so that they travel on spiral paths back and forth until they collide with the rest gas molecules, producing ions which are collected as an ion current at a cylinder surrounding the four hyperbolically shaped quadrupole electrodes.

Schwarz, H.↗

Redundant integrated flight control/navigation inertial sensor complex

A redundant strapdown inertial navigation system for integrated flight control/navigation use is described. Design of the system, which consists of four tuned-gimbal gyros, eight accelerometers, and four processors, is discussed, with emphasis on its compact configuration (13 by 13 by 14 in.), based on symmetry properties of an octahedron. A matrix operator for least-squares combination of data from an arbitrary number of two-degree-of-freedom gyros is derived, and general parity equations for error analysis are given. Self-contained detection and isolation of a two-axis gyro failure is considered; system failure probability, which depends on component failure rates and self-correction capacities, is analyzed. Test data, including typical parity equation responses during motion and simulated gyro and accelerometer failures, are also presented.

Ebner, R. E.↗

Single heterostructure lasers of PbS/1-x/Se/x/ and Pb/1-x/Sn/x/Se with wide tunability

Single-heterostructure diode lasers formed by compositional interdiffusion (CID) and liquid-phase epitaxy (LPE) of lead salts are discussed. The CID technique, which involves creation of a single heterostructure in a pseudobinary compound having binary constituents with different vapor pressures, is reviewed; growth of lead-salt crystals of various compositions is described. Some electrical and optical characteristics, including properties indicative of high internal quantum efficiencies, are given for lasers which employ the CID and LPE diodes. High operating temperatures (i.e., liquid nitrogen levels and above), together with wide tuning ranges (a diode wavelength of 12.7 microns is reported), make the lasers useful in high-resolution spectrometry and advanced trace-gas monitoring systems.

Linden, K. J.↗