Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A “Train-Track” Technique in Anatomic Reconstruction of SVC Bifurcation Complicated by Cardiac Tamponade: An Introspection

This report describes a stenting technique used to anatomically reconstruct superior vena cava (SVC) bifurcation in a patient with benign SVC syndrome. After recanalizing the SVC bifurcation, we exchanged two 0.035-in. wires for two 0.018-in. wires, deployed the SVC stent over these two wires (“train-track” technique), and stented each innominate vein over one wire. However, our decisions to recanalize both innominate veins, use the “buddy-wire” technique for SVC dilation, and dilate the SVC to 16 mm before stent deployment likely contributed to SVC tear, which was managed by resuscitation, SVC stent placement, and pericardial drainage. Here, we describe the steps of the train-track technique, which can be adopted to reconstruct other bifurcations; we also discuss the controversial aspects of this case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Solidification in Bulk Ti-Nb Alloys by Single-Track Laser Melting

Single-track laser melting experiments were performed on bulk Ti-Nb alloys to explore process parameters and the resultant macroscopic structure and microstructure. The microstructures in Ti-20Nb and Ti-50Nb (at.%) alloys exhibited cellular growth during rapid solidification, with average cell size of approximately 0.5 µm. Solidification velocities during cellular growth were calculated from images of melt tracks. Measurements of the composition in the cellular and intercellular regions revealed nonequilibrium partitioning and its dependence on velocity during rapid solidification. Furthermore, experimental results were used to benchmark a phase-field model to describe rapid solidification under conditions relevant to additive manufacturing.

36 MATERIALS SCIENCE↗

Detecting and Tracking Nonfluorescent Nanoparticles Probes in Live Cells

Precisely imaging and tracking dynamic biological processes in live cells are crucial for both fundamental research in life sciences and biomedical applications. Nonfluorescent nanoparticles are emerging as important optical probes in live-cell imaging because of their excellent photostability, large optical cross sections, and low cytotoxicity. Here, we provide a review of recent development in optical imaging of nonfluorescent nanoparticle probes and their applications in dynamic tracking and biosensing in live cells. A brief discussion on cytotoxicity of nanoparticle probes is also provided.

36 MATERIALS SCIENCE↗

Heterogeneity or illusion? Track the carbon Kuznets curve of global residential building operations

Residential buildings, the “last mile” sector in the global decarbonization, have become the most significant uncertain factor hindering carbon neutrality with increasing household energy demand. To track the operational carbon in buildings, this study investigates the carbon Kuznets curve (CKC) and the corresponding decoupling status of residential building operations at four emission scales by using the data of 30 countries from 2000 to 2019. The results show that (1) the CKC model can fit more than half of the samples. Most curves have an inverted U-shape, with 76% of emission per household and 82% of total emissions. (2) In the presence of the CKC, over four-fifths of global residential buildings peak regardless of any emission scale. The analysis denotes that the carbon emissions of developed countries reach their peaks earlier. In the total emissions, the samples’ peaking proportion is 20% and 25% with income per capita < 20,000 United States dollars (USD) and 20,000–40,000 USD, respectively. (3) The Tapio decoupling analysis and the threshold regression effectively verify the robustness and the heterogeneity of CKCs, respectively. Strong decoupling effects of CKCs in most countries are demonstrated at the scales of emission per floor space and the total emissions, and the heterogeneity proves the classic inverted U-shaped relationship between economy and emissions doesn’t exist in all emitters. Overall, this study tracks the historical carbon emission trajectories of residential building operations at a global scale, providing reference for different economies to simulate the dynamic of building carbon emissions along with the economic booming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DNA-binding induced conformational change of c-Myb R2R3 analyzed using diffracted X-ray tracking

Highlights: • DNA-binding protein, c-Myb R2R3, largely fluctuates in solution. • We evaluated structural dynamics of R2R3 using diffracted X-ray tracking (DXT). • The flexibility of R2R3 is decreased upon the DNA binding. • We could determine the DNA-binding energies of R2R3 using DXT. Previous structural analyses have shown that R2R3, the minimum unit of the DNA-binding domain of the transcriptional factor c-Myb, is largely flexible in solution, and changes to a more rigid structure upon DNA binding. In this study, we evaluated the structural dynamics using the diffracted X-ray tracking method, in correlation with DNA-binding abilities under different salt conditions, and compared them with the previous results. The resultant curve of the mean square angular displacements (MSD) clearly showed that the flexibility of R2R3 was decreased upon DNA binding, and the DNA-binding energies determined using the angular diffusion coefficients were in good agreement with those determined using isothermal titration calorimetry. The results of the MSD curves also indicate that the translational length reduces by approximately half upon DNA binding.

60 APPLIED LIFE SCIENCES↗

Microbial source tracking markers associated with domestic rainwater harvesting systems: Correlation to indicator organisms

Highlights: • Microbial source tracking markers are present in harvested rainwater. • HF183, Lachnospiraceae, B. adolescentis and adenovirus correlate with indicators. • HF183, adenovirus and Lachnospiraceae co-occurred with indicator organisms. • These MST markers may be incorporated in a toolbox to supplement indicator analysis. Domestic rainwater harvesting (tank water) systems were screened for the presence of a panel of microbial source tracking (MST) markers and traditional indicator organisms. The indicator organisms were enumerated utilizing traditional culture-based methods, while the MST markers were quantified by quantitative PCR (qPCR). The indicators Escherichia coli (E. coli) and enterococci were also quantified using qPCR. Correlations and concurrence between these parameters were then investigated to determine which markers could be utilized to supplement traditional indicator analysis. Quantitative PCR analysis indicated that Bacteroides HF183, adenovirus, Lachnospiraceae and E. coli were detected and quantifiable in 100% of the tank water samples collected throughout the sampling period, while human mitochondrial DNA (mtDNA) was quantifiable in 90% of the tank water samples and Bifidobacterium adolescentis (B. adolescentis) and enterococci were quantifiable in 67% of the tank water samples, respectively. Significant positive correlations were recorded for Lachnospiraceae versus heterotrophic bacteria (p = 0.000), adenovirus versus E. coli (culturing) (p = 0.000) and heterotrophic bacteria (p = 0.024), the HF183 marker versus E. coli (qPCR) (p = 0.024) and B. adolescentis versus fecal coliforms (p = 0.037). In addition, 100% concurrence was observed for the HF183 marker, adenovirus and Lachnospiraceae versus E. coli (qPCR), enterococci (qPCR) and heterotrophic bacteria, amongst others. Based on the correlations and the concurrence analysis, the HF183 marker, Lachnospiraceae and adenovirus may be utilized to supplement indicator organism analysis for the monitoring of harvested rainwater quality.

54 ENVIRONMENTAL SCIENCES↗

The evolutionary rate dynamically tracks changes in HIV-1 epidemics

Large-sequence datasets provide an opportunity to investigate the dynamics of pathogen epidemics. Thus, a fast method to estimate the evolutionary rate from large and numerous phylogenetic trees becomes necessary. Based on minimizing tip height variances, we optimize the root in a given phylogenetic tree to estimate the most homogenous evolutionary rate between samples from at least two different time points. Simulations showed that the method had no bias in the estimation of evolutionary rates and that it was robust to tree rooting and topological errors. We show that the evolutionary rates of HIV-1 subtype B and C epidemics have changed over time, with the rate of evolution inversely correlated to the rate of virus spread. For subtype B, the evolutionary rate slowed down and tracked the start of the HAART era in 1996. Subtype C in Ethiopia showed an increase in the evolutionary rate when the prevalence increase markedly slowed down in 1995. Thus, we show that the evolutionary rate of HIV-1 on the population level dynamically tracks epidemic events.

59 BASIC BIOLOGICAL SCIENCES↗

Off-line tracking of series parameters in distribution systems using AMI data

Electric distribution systems have historically lacked measurement points, and equipment is often operated to its failure point, resulting in customer outages. The widespread deployment of sensors at the distribution level is enabling observability. This paper presents an off-line parameter value tracking procedure that takes advantage of the increasing number of measurement devices being deployed at the distribution level to estimate changes in series impedance parameter values over time. The tracking of parameter values enables non-diurnal and non-seasonal change to be flagged for investigation. The presented method uses an unbalanced Distribution System State Estimation (DSSE) and a measurement residual-based parameter estimation procedure. Measurement residuals from multiple measurement snapshots are combined in order to increase the effective local redundancy and improve the robustness of the calculations in the presence of measurement noise. Data from devices on the primary distribution system and from customer meters, via an AMI system, form the input data set. Results of simulations on the IEEE 13-Node Test Feeder are presented to illustrate the proposed approach applied to changes in series impedance parameters. A 5% change in series resistance elements can be detected in the presence of 2% measurement error when combining less than 1 day of measurement snapshots into a single estimate.

Williams, Tess L.↗

Planning Study Comparison of Real-Time Target Tracking and Four-Dimensional Inverse Planning for Managing Patient Respiratory Motion

Purpose: Real-time target tracking (RT-TT) and four-dimensional inverse planning (4D-IP) are two potential methods to manage respiratory target motion. In this study, we evaluated each method using the cumulative dose-volume criteria in lung cancer radiotherapy. Methods and Materials: Respiration-correlated computed tomography scans were acquired for 4 patients. Deformable image registration was applied to generate a displacement mapping for each phase image of the respiration-correlated computed tomography images. First, the dose distribution for the organs of interest obtained from an idealized RT-TT technique was evaluated, assuming perfect knowledge of organ motion and beam tracking. Inverse planning was performed on each phase image separately. The treatment dose to the organs of interest was then accumulated from the optimized plans. Second, 4D-IP was performed using the probability density function of respiratory motion. The beam arrangement, prescription dose, and objectives were consistent in both planning methods. The dose-volume and equivalent uniform dose in the target volume, lung, heart, and spinal cord were used for the evaluation. Results: The cumulative dose in the target was similar for both techniques. The equivalent uniform dose of the lung, heart, and spinal cord was 4.6 {+-} 2.2, 11 {+-} 4.4, and 11 {+-} 6.6 Gy for RT-TT with a 0-mm target margin, 5.2 {+-} 3.1, 12 {+-} 5.9, and 12 {+-} 7.8 Gy for RT-TT with a 2-mm target margin, and 5.3 {+-} 2.3, 11.9 {+-} 5.0, and 12 {+-} 5.6 Gy for 4D-IP, respectively. Conclusion: The results of our study have shown that 4D-IP can achieve plans similar to those achieved by RT-TT. Considering clinical implementation, 4D-IP could be a more reliable and practical method to manage patient respiration-induced motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Intensity-Modulated Radiotherapy Planning for Dynamic Multileaf Collimator Tracking Radiotherapy

Purpose: To develop a four-dimensional intensity-modulated radiotherapy (IMRT) planning method for dynamic multileaf collimator (DMLC)-based tumor tracking that takes respiratory motion into consideration. Methods and Materials: Using the concept of optimal deformation, a series of apertures are placed at different phases in the same segment to ensure maximally similar dose contributions at various anatomic points. We used a direct aperture optimization method to find a set of segments that achieved an optimal dose distribution for aperture shapes at the reference phase and achieved corresponding optimal deformations at other phases that took respiratory motion into consideration. In our four-dimensional direct aperture optimization (4D-DAO) method, a simulated annealing algorithm and a conjugate gradients algorithm were used to optimize the shape of the segments and the monitor units, respectively. We then compared the optimization results for three-dimensional conformal radiotherapy and 4D-DAO based on a set of simulated respiration 4D computed tomography (4DCT) data and a set of real 4DCT data. Results: Dosimetric analysis indicated that, compared with the 3DCRT method, the dose distribution is significantly improved when the optimal deformation tracking technique is used, even when the maximum velocity limit of the DMLC leaves is set. Conclusions: The proposed 4D-IMRT planning method can find a set of segments and the corresponding leaf movements, which can trace the tumor motion and thus protect more normal tissue from radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Multileaf Collimator Tracking of Respiratory Target Motion Based on a Single Kilovoltage Imager During Arc Radiotherapy

Purpose: To demonstrate and characterize dynamic multileaf collimator (DMLC) tracking of respiratory moving targets that are spatially localized with a single kV X-ray imager during arc radiotherapy. Methods and Materials: During delivery of an arc field (358 deg. gantry rotation, 72-sec duration, circular field shape), the three-dimensional (3D) position of a fiducial marker in a phantom was estimated in real time from fluoroscopic kV X-ray images acquired orthogonally to the treatment beam axis. A prediction algorithm was applied to account for system latency (570 ms) before the estimated marker position was used for DMLC aperture adaptation. Experiments were performed with 12 patient-measured tumor trajectories that were selected from 160 trajectories (46 patients) and reproduced by a programmable phantom. Offline, the 3D deviation of the estimated phantom position from the actual position was quantified. The two-dimensional (2D) beam-target deviation was quantified as the positional difference between the MLC aperture center and the marker in portal images acquired continuously during experiments. Simulations of imaging and treatment delivery extended the study to all 160 tumor trajectories and to arc treatments of 3-min and 5-min duration. Results: In the experiments, the mean root-mean-square deviation was 1.8 mm for the 3D target position and 1.5 mm for the 2D aperture position. Simulations agreed with this to within 0.1 mm and resulted in mean 2D root-mean-square beam-target deviations of 1.1 mm for all 160 trajectories for all treatment durations. The deviations were mainly caused by system latency (570 ms). Conclusions: Single-imager DMLC tracking of respiratory target motion during arc radiotherapy was implemented, providing less than 2-mm geometric uncertainty for most trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Prostate Tracking and Motion Assessment in Volumetric Modulated Arc Therapy With an Electronic Portal Imaging Device

Purpose: To assess the prostate intrafraction motion in volumetric modulated arc therapy treatments using cine megavoltage (MV) images acquired with an electronic portal imaging device (EPID). Methods and Materials: Ten prostate cancer patients were treated with volumetric modulated arc therapy using a Varian TrueBeam linear accelerator equipped with an EPID for acquiring cine MV images during treatment. Cine MV images acquisition was scheduled for single or multiple treatment fractions (between 1 and 8). A novel automatic fiducial detection algorithm that can handle irregular multileaf collimator apertures, field edges, fast leaf and gantry movement, and MV image noise and artifacts in patient anatomy was used. All sets of images (approximately 25,000 images in total) were analyzed to measure the positioning accuracy of implanted fiducial markers and assess the prostate movement. Results: Prostate motion can vary greatly in magnitude among different patients. Different motion patterns were identified, showing its unpredictability. The mean displacement and standard deviation of the intrafraction motion was generally less than 2.0 ± 2.0 mm in each of the spatial directions. In certain patients, however, the percentage of the treatment time in which the prostate is displaced more than 5 mm from its planned position in at least 1 spatial direction was 10% or more. The maximum prostate displacement observed was 13.3 mm. Conclusion: Prostate tracking and motion assessment was performed with MV imaging and an EPID. The amount of prostate motion observed suggests that patients will benefit from its real-time monitoring. Megavoltage imaging can provide the basis for real-time prostate tracking using conventional linear accelerators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the reliability of the motion model is envisaged, the developed technique does not involve the estimation and continuous update of correlation parameters, thus requiring a less intense use of invasive imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Random walk particle tracking simulations of non-Fickian transport in heterogeneous media

Derivations of continuum nonlocal models of non-Fickian (anomalous) transport require assumptions that might limit their applicability. We present a particle-based algorithm, which obviates the need for many of these assumptions by allowing stochastic processes that represent spatial and temporal random increments to be correlated in space and time, be stationary or non-stationary, and to have arbitrary distributions. The approach treats a particle trajectory as a subordinated stochastic process that is described by a set of Langevin equations, which represent a continuous time random walk (CTRW). Convolution-based particle tracking (CBPT) is used to increase the computational efficiency and accuracy of these particle-based simulations. The combined CTRW-CBPT approach enables one to convert any particle tracking legacy code into a simulator capable of handling non-Fickian transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On high-order shock-fitting and front-tracking schemes for numerical simulation of shock–disturbance interactions

High-order methods that can resolve interactions of flow-disturbances with shock waves are critical for reliable numerical simulation of shock wave and turbulence interaction. Such problems are not well understood due to the limitations of numerical methods. Most of the popular shock-capturing methods are only first-order accurate at the shock and may incur spurious numerical oscillations near the shock. Shock-fitting algorithms have been proposed as an alternative which can achieve uniform high-order accuracy and can avoid possible spurious oscillations incurred in shock-capturing methods by treating shocks as sharp interfaces. We explore two ways for shock-fitting: conventional moving grid set-up and a new fixed grid set-up with front tracking. In the conventional shock-fitting method, a moving grid is fitted to the shock whereas in the newly developed fixed grid set-up the shock front is tracked using Lagrangian points and is free to move across the underlying fixed grid.

Rawat, Pradeep Singh↗

An efficient level set method for tracking many materials

Here, we present an efficient level set method to track an arbitrary number of materials. The algorithm is optimal in the sense that it only needs to store a single unsigned distance-like function and a single integer indicator function, independent of the number of materials or distinct regions being tracked. Furthermore, for smooth velocity fields and smooth interface shape, arbitrarily high order solutions can be demonstrated. For interfaces that are or become kinked, the solution is limited to second-order convergence rates in the L 1 norm and first-order in the L ∞ norm.

97 MATHEMATICS AND COMPUTING↗

Latent space dynamics identification for interface tracking with application to shock-induced pore collapse

Capturing sharp, evolving interfaces remains a central challenge in reduced-order modeling, especially when data is limited and the system exhibits localized nonlinearities or discontinuities. Here, we propose LaSDI-IT (Latent Space Dynamics Identification for Interface Tracking), a data-driven framework that combines low-dimensional latent dynamics learning with explicit interface-aware encoding to enable accurate and efficient modeling of physical systems involving moving material boundaries. At the core of LaSDI-IT is a revised autoencoder architecture that jointly reconstructs the physical field and an indicator function representing material regions or phases, allowing the model to track complex interface evolution without requiring detailed physical models or mesh adaptation. The latent dynamics are learned through linear regression in the encoded space and generalized across parameter regimes using Gaussian process interpolation with greedy sampling. We demonstrate LaSDI-IT on the problem of shock-induced pore collapse in high explosives, a process characterized by sharp temperature gradients and dynamically deforming pore geometries. The method achieves relative prediction errors below 9% across the parameter space, accurately recovers key quantities of interest such as pore area and hot spot formation, and matches the performance of dense training with only half the data. This latent dynamics prediction was 10 6 times faster than the conventional high-fidelity simulation, proving its utility for multi-query applications. These results highlight LaSDI-IT as a general, data-efficient framework for modeling discontinuity-rich systems in computational physics, with potential applications in multiphase flows, fracture mechanics, and phase change problems.

Gaussian process↗