Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tool”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

SU-E-T-253: Development of a GDPM Monte Carlo Based Quality Assurance Tool for Cyberknife

Purpose: To develop a 3D quality assurance (QA) tool for Cyberknife plans using a GPU-based Monte Carlo dose calculation package, gDPM. The developed QA tool will be used as a secondary check for Cyberknife treatment planning software (TPS) reported dose distributions. Methods: Phase space files of the 5, 7.5, 10, 15, and 60 mm iris cones were downloaded from IAEA phase-space database. From the 60mm iris cone phase space file, we were able to generate raw phase space files for all other cones using a particle rejection method. The particles in the raw phase space files were binned with respect to the radial position and energy for commissioning. During the commissioning process, gDPM calculated percent depth dose and off-center ratios which were compared to those measured in the Blue Phantom. The off-axis data was measured with an SAD setup at depths of 15, 50, 100, 200, and 300 mm. At the commissioning stage, an optimization problem was solved to adjust the binned particles weights to minimize the difference between the calculated and measured ones. Commissioning validations will be performed by measuring point dose data of patient specific plans delivered to water phantoms. With commissioned phase space files, 3D patient-specific dose distributions will be calculated and compared against TPS reported dose. Results: Beyond the initial buildup region, the root mean square difference between the calculated and measured percent depth dose differences was less than 0.5%. The full-width half-max data from the off-axis ratio calculations was found to be within 0.1 mm of the measured data. Conclusion: Our current work showed excellent agreement between the gDPM calculated dose and the measured data for all cone sizes and types for the Cyberknife system. Implementation of a fast and accurate QA tool for patient specific plans will be feasible with this tool.

60 APPLIED LIFE SCIENCES↗

SU-E-T-254: Development of a HDR-BT QA Tool for Verification of Source Position with Oncentra Applicator Modeling

Purpose: To develop a High Dose Rate Brachytherapy (HDR-BT) quality assurance (QA) tool for verification of source position with Oncentra applicator modeling, and to report the results of radiation source positions with this tool. Methods: We developed a HDR-BT QA phantom and automated analysis software for verification of source position with Oncentra applicator modeling for the Fletcher applicator used in the MicroSelectron HDR system. This tool is intended for end-to-end tests that mimic the clinical 3D image-guided brachytherapy (3D-IGBT) workflow. The phantom is a 30x30x3 cm cuboid phantom with radiopaque markers, which are inserted into the phantom to evaluate applicator tips and reference source positions; positions are laterally shifted 10 mm from the applicator axis. The markers are lead-based and scatter radiation to expose the films. Gafchromic RTQA2 films are placed on the applicators. The phantom includes spaces to embed the applicators. The source position is determined as the distance between the exposed source position and center position of two pairs of the first radiopaque markers. We generated a 3D-IGBT plan with applicator modeling. The first source position was 6 mm from the applicator tips, and the second source position was 10 mm from the first source position. Results: All source positions were consistent with the exposed positions within 1 mm for all Fletcher applicators using in-house software. Moreover, the distance between source positions was in good agreement with the reference distance. Applicator offset, determined as the distance from the applicator tips at the first source position in the treatment planning system, was accurate. Conclusion: Source position accuracy of applicator modeling used in 3D-IGBT was acceptable. This phantom and software will be useful as a HDR-BT QA tool for verification of source position with Oncentra applicator modeling.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-12: End-User Oriented Tools and Procedures for Testing Brachytherapy TPSs Employing MBDCAs

Purpose: To develop user-oriented tools for commissioning and dosimetry testing of {sup 192}Ir brachytherapy treatment planning systems (TPSs) employing model based dose calculation algorithms (MBDCAs). Methods: A software tool (BrachyGuide) has been developed for the automatic generation of MCNP6 input files from any CT based plan exported in DICOM RT format from Elekta and Varian TPSs. BrachyGuide also facilitates the evaluation of imported Monte Carlo (MC) and TPS dose distributions in terms of % dose differences and gamma index (CT overlaid colormaps or relative frequency plots) as well as DVHs and related indices. For users not equipped to perform MC, a set of computational models was prepared in DICOM format, accompanied by treatment plans and corresponding MCNP6 generated reference data. BrachyGuide can then be used to compare institutional and reference data as per TG186. The model set includes a water sphere with the MBDCA WG {sup 192}Ir source placed centrically and in two eccentric positions, a water sphere with cubic bone and lung inhomogeneities and a five source dwells plan, and a patient equivalent model with an Accelerated Partial Breast Irradiation (APBI) plan. Results: The tools developed were used for the dosimetry testing of the Acuros and ACE MBDCAs implemented in BrachyVision v.13 and Oncentra Brachy v.4.5, respectively. Findings were consistent with previous results in the literature. Besides points close to the source dwells, Acuros was found to agree within type A uncertainties with the reference MC results. Differences greater than MC type A uncertainty were observed for ACE at distances >5cm from the source dwells and in bone. Conclusion: The tools developed are efficient for brachytherapy MBDCA planning commissioning and testing. Since they are appropriate for distribution over the web, they will be put at the AAPM WG MBDCA’s disposal. Research co-financed by the ESF and Greek funds. NSRF operational Program: Education and Lifelong Learning Investing in Knowledge Society-Aristeia. Varian Medical Systems and Nucletron, an Elekta company provided access to TPSs for research purposes. Miss Peppa was supported by IKY-fellowships of excellence for postgraduate studies in Greece,Siemens Program.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-03: TOPAS-edu: A Window Into the Stochastic World Through the TOPAS Tool for Particle Simulation

Purpose: The stochastic nature of the subatomic world presents a challenge for physics education. Even experienced physicists can be amazed at the varied behavior of electrons, x-rays, protons, neutrons, ions and the any short-lived particles that make up the overall behavior of our accelerators, brachytherapy sources and medical imaging systems. The all-particle Monte Carlo particle transport tool, TOPAS Tool for Particle Simulation, originally developed for proton therapy research, has been repurposed into a physics teaching tool, TOPAS-edu. Methods: TOPAS-edu students set up simulated particle sources, collimators, scatterers, imagers and scoring setups by writing simple ASCII files (in the TOPAS Parameter Control System format). Students visualize geometry setups and particle trajectories in a variety of modes from OpenGL graphics to VRML 3D viewers to gif and PostScript image files. Results written to simple comma separated values files are imported by the student into their preferred data analysis tool. Students can vary random seeds or adjust parameters of physics processes to better understand the stochastic nature of subatomic physics. Results: TOPAS-edu has been successfully deployed as the centerpiece of a physics course for master’s students at Queen’s University Belfast. Tutorials developed there takes students through a step by step course on the basics of particle transport and interaction, scattering, Bremsstrahlung, etc. At each step in the course, students build simulated experimental setups and then analyze the simulated results. Lessons build one upon another so that a student might end up with a full simulation of a medical accelerator, a water-phantom or an imager. Conclusion: TOPAS-edu was well received by students. A second application of TOPAS-edu is currently in development at Zurich University of Applied Sciences, Switzerland. It is our eventual goal to make TOPAS-edu available free of charge to any non-profit organization, along with associated tutorial materials developed by the TOPAS-edu community. Work supported in part by the U.S. Department of Energy under contract number DE-AC02-76SF00515. B. Villagomez-Bernabe is supported by CONACyT (Mexican Council for Science and Technology) project 231844.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-06: MrRSCAL: A Radiological Simulation Tool for Resident Education

Purpose: The goal of this project was to create a readily accessible, comprehensive-yet-flexible interactive MRI simulation tool for use in training and education of radiology residents in particular. This tool was developed to take the place of an MR scanner in laboratory activities, as magnet time has become scarce while hospitals are optimizing clinical scheduling for improved throughput. Methods: MrRSCAL (Magnetic resonance Resident Simulation Console for Active Learning) was programmed and coded using Matlab on a Mac workstation utilizing OS X platform. MR-based brain images were obtained from one of the co-authors and processed to generate parametric maps. Scanner sounds are also generated via mp3 convolution of a single MR gradient slew with a time-profile of gradient waveforms. Results: MrRSCAL facilitates the simulation of multiple MR sequences with the ability to alter MR parameters via an intuitive GUI control panel. The application allows the user to gain real-time understanding of image transformation when varying these said parameters by examining the resulting images. Lab procedures can be loaded and displayed for more directed study. The panel is also configurable, providing a simple interface for elementary labs or a full array of controls for the expert user. Conclusion: Our introduction of MrRSCAL, which is readily available to users with a current laptop or workstation, allows for individual or group study of MR image acquisition with immediate educational feedback as the MR parameters are manipulated. MrRSCAL can be used at any time and any place once installed, offering a new tool for reviewing relaxometric and artifact principles when studying for boards or investigating properties of a pulse sequence. This tool promises to be extremely useful in conveying traditionally difficult and abstract concepts involved with MR to the radiology resident and other medical professionals at large.

60 APPLIED LIFE SCIENCES↗

SU-C-202-03: A Tool for Automatic Calculation of Delivered Dose Variation for Off-Line Adaptive Therapy Using Cone Beam CT

Purpose: Monitoring the delivered dose is an important task for the adaptive radiotherapy (ART) and for determining time to re-plan. A software tool which enables automatic delivered dose calculation using cone-beam CT (CBCT) has been developed and tested. Methods: The tool consists of four components: a CBCT Colleting Module (CCM), a Plan Registration Moduel (PRM), a Dose Calculation Module (DCM), and an Evaluation and Action Module (EAM). The CCM is triggered periodically (e.g. every 1:00 AM) to search for newly acquired CBCTs of patients of interest and then export the DICOM files of the images and related registrations defined in ARIA followed by triggering the PRM. The PRM imports the DICOM images and registrations, links the CBCTs to the related treatment plan of the patient in the planning system (RayStation V4.5, RaySearch, Stockholm, Sweden). A pre-determined CT-to-density table is automatically generated for dose calculation. Current version of the DCM uses a rigid registration which regards the treatment isocenter of the CBCT to be the isocenter of the treatment plan. Then it starts the dose calculation automatically. The AEM evaluates the plan using pre-determined plan evaluation parameters: PTV dose-volume metrics and critical organ doses. The tool has been tested for 10 patients. Results: Automatic plans are generated and saved in the order of the treatment dates of the Adaptive Planning module of the RayStation planning system, without any manual intervention. Once the CTV dose deviates more than 3%, both email and page alerts are sent to the physician and the physicist of the patient so that one can look the case closely. Conclusion: The tool is capable to perform automatic dose tracking and to alert clinicians when an action is needed. It is clinically useful for off-line adaptive therapy to catch any gross error. Practical way of determining alarming level for OAR is under development.

60 APPLIED LIFE SCIENCES↗

SU-F-P-35: A Multi-Institutional Plan Quality Checking Tool Built On Oncospace: A Shared Radiation Oncology Database System

Purpose: Late toxicity from radiation to critical structures limits the possible dose in Radiation Therapy. Perfectly conformal treatment of a target is not realizable, so the clinician must accept a certain level of collateral radiation to nearby OARs. But how much? General guidelines exist for healthy tissue sparing which guide RT treatment planning, but are these guidelines good enough to create the optimal plan given the individualized patient anatomy? We propose a means to evaluate the planned dose level to an OAR using a multi-institutional data-store of previously treated patients, so a clinician might reconsider planning objectives. Methods: The tool is built on Oncospace, a federated data-store system, which consists of planning data import, web based analysis tools, and a database containing:1) DVHs: dose by percent volume delivered to each ROI for each patient previously treated and included in the database.2) Overlap Volume Histograms (OVHs): Anatomical measure defined as the percent volume of an ROI within a given distance to target structures.Clinicians know what OARs are important to spare. For any ROI, Oncospace knows for which patients’ anatomy that ROI was harder to plan in the past (the OVH is less). The planned dose should be close to the least dose of previous patients. The tool displays the dose those OARs were subjected to, and the clinician can make a determination about the planning objectives used.Multiple institutions contribute to the Oncospace Consortium, and their DVH and OVH data are combined and color coded in the output. Results: The Oncospace website provides a plan quality display tool which identifies harder to treat patients, and graphically displays the dose delivered to them for comparison with the proposed plan. Conclusion: The Oncospace Consortium manages a data-store of previously treated patients which can be used for quality checking new plans. Grant funding by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-J-204: Carbon Digitally Reconstructed Radiography (CDRR): A GPU Based Tool for Fast and Versatile Carbonimaging Simulation

Purpose: Research in carbon imaging has been growing over the past years, as a way to increase treatment accuracy and patient positioning in carbon therapy. The purpose of this tool is to allow a fast and flexible way to generate CDRR data without the need to use Monte Carlo (MC) simulations. It can also be used to predict future clinically measured data. Methods: A python interface has been developed, which uses information from CT or 4DCT and thetreatment calibration curve to compute the Water Equivalent Path Length (WEPL) of carbon ions. A GPU based ray tracing algorithm computes the WEPL of each individual carbon traveling through the CT voxels. A multiple peak detection method to estimate high contrast margin positioning has been implemented (described elsewhere). MC simulations have been used to simulate carbons depth dose curves in order to simulate the response of a range detector. Results: The tool allows the upload of CT or 4DCT images. The user has the possibility to selectphase/slice of interested as well as position, angle…). The WEPL is represented as a range detector which can be used to assess range dilution and multiple peak detection effects. The tool also provides knowledge of the minimum energy that should be considered for imaging purposes. The multiple peak detection method has been used in a lung tumor case, showing an accuracy of 1mm in determine the exact interface position. Conclusion: The tool offers an easy and fast way to simulate carbon imaging data. It can be used for educational and for clinical purposes, allowing the user to test beam energies and angles before real acquisition. An analysis add-on is being developed, where the used will have the opportunity to select different reconstruction methods and detector types (range or energy). Fundacao para a Ciencia e a Tecnologia (FCT), PhD Grant number SFRH/BD/85749/2012.

60 APPLIED LIFE SCIENCES↗

SU-F-T-459: ArcCHECK Machine QA : Highly Efficient Quality Assurance Tool for VMAT, SRS & SBRT Linear Accelerator Delivery

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. ArcCHECK Machine QA tool is used to test geometric and delivery aspects of linear accelerator. In this study we evaluated the performance of this tool. Methods: Machine QA feature allows user to perform quality assurance tests using ArcCHECK phantom. Following tests were performed 1) Gantry Speed 2) Gantry Rotation 3) Gantry Angle 4)MLC/Collimator QA 5)Beam Profile Flatness & Symmetry. Data was collected on trueBEAM stX machine for 6 MV for a period of one year. The Gantry QA test allows to view errors in gantry angle, rotation & assess how accurately the gantry moves around the isocentre. The MLC/Collimator QA tool is used to analyze & locate the differences between leaf bank & jaw position of linac. The flatness & Symmetry test quantifies beam flatness & symmetry in IEC-y & x direction. The Gantry & Flatness/Symmetry test can be performed for static & dynamic delivery. Results: The Gantry speed was 3.9 deg/sec with speed maximum deviation around 0.3 deg/sec. The Gantry Isocentre for arc delivery was 0.9mm & static delivery was 0.4mm. The maximum percent positive & negative difference was found to be 1.9 % & – 0.25 % & maximum distance positive & negative diff was 0.4mm & – 0.3 mm for MLC/Collimator QA. The Flatness for Arc delivery was 1.8 % & Symmetry for Y was 0.8 % & X was 1.8 %. The Flatness for gantry 0°,270°,90° & 180° was 1.75,1.9,1.8 & 1.6% respectively & Symmetry for X & Y was 0.8,0.6% for 0°, 0.6,0.7% for 270°, 0.6,1% for 90° & 0.6,0.7% for 180°. Conclusion: ArcCHECK Machine QA is an useful tool for QA of Modern linear accelerators as it tests both geometric & delivery aspects. This is very important for VMAT, SRS & SBRT treatments.

43 PARTICLE ACCELERATORS↗

TU-FG-201-05: Varian MPC as a Statistical Process Control Tool

Purpose: Quality assurance in radiotherapy requires the measurement of various machine parameters to ensure they remain within permitted values over time. In Truebeam release 2.0 the Machine Performance Check (MPC) was released allowing beam output and machine axis movements to be assessed in a single test. We aim to evaluate the Varian Machine Performance Check (MPC) as a tool for Statistical Process Control (SPC). Methods: Varian’s MPC tool was used on three Truebeam and one EDGE linac for a period of approximately one year. MPC was commissioned against independent systems. After this period the data were reviewed to determine whether or not the MPC was useful as a process control tool. Analyses on individual tests were analysed using Shewhart control plots, using Matlab for analysis. Principal component analysis was used to determine if a multivariate model was of any benefit in analysing the data. Results: Control charts were found to be useful to detect beam output changes, worn T-nuts and jaw calibration issues. Upper and lower control limits were defined at the 95% level. Multivariate SPC was performed using Principal Component Analysis. We found little evidence of clustering beyond that which might be naively expected such as beam uniformity and beam output. Whilst this makes multivariate analysis of little use it suggests that each test is giving independent information. Conclusion: The variety of independent parameters tested in MPC makes it a sensitive tool for routine machine QA. We have determined that using control charts in our QA programme would rapidly detect changes in machine performance. The use of control charts allows large quantities of tests to be performed on all linacs without visual inspection of all results. The use of control limits alerts users when data are inconsistent with previous measurements before they become out of specification. A. Carver has received a speaker’s honorarium from Varian.

07 ISOTOPE AND RADIATION SOURCES↗

WE-DE-201-02: A Statistical Analysis Tool for Plan Quality Verification in HDR Brachytherapy Forward Planning for Cervix Cancer

Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginal mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.

60 APPLIED LIFE SCIENCES↗

Poster - 30: Use of a Hazard-Risk Analysis for development of a new eye immobilization tool for treatment of choroidal melanoma

Purpose: Our treatment for choroidal melanoma utilizes the GTC frame. The patient looks at a small LED to stabilize target position. The LED is attached to a metal arm attached to the GTC frame. A camera on the arm allows therapists to monitor patient compliance. To move to mask-based immobilization we need a new LED/camera attachment mechanism. We used a Hazard-Risk Analysis (HRA) to guide the design of the new tool. Method: A pre-clinical model was built with input from therapy and machine shop personnel. It consisted of an aluminum frame placed in aluminum guide posts attached to the couch top. Further development was guided by the Department of Defense Standard Practice - System Safety hazard risk analysis technique. Results: An Orfit mask was selected because it allowed access to indexes on the couch top which assist with setup reproducibility. The first HRA table was created considering mechanical failure modes of the device. Discussions with operators and manufacturers identified other failure modes and solutions. HRA directed the design towards a safe clinical device. Conclusion: A new immobilization tool has been designed using hazard-risk analysis which resulted in an easier-to-use and safer tool compared to the initial design. The remaining risks are all low probability events and not dissimilar from those currently faced with the GTC setup. Given the gains in ease of use for therapists and patients as well as the lower costs for the hospital, we will implement this new tool.

60 APPLIED LIFE SCIENCES↗

Tools for genetic engineering and gene expression control in Novosphingobium aromaticivorans and Rhodobacter sphaeroides

ABSTRACT Alphaproteobacteria have a variety of cellular and metabolic features that provide important insights into biological systems and enable biotechnologies. For example, some species are capable of converting plant biomass into valuable biofuels and bioproducts that have the potential to contribute to the sustainable bioeconomy. Among the Alphaproteobacteria, Novosphingobium aromaticivorans , Rhodobacter sphaeroides , and Zymomonas mobilis show promise as organisms that can be engineered to convert extracted plant lignin or sugars into bioproducts and biofuels. Genetic manipulation of these bacteria is needed to introduce engineered pathways and modulate expression of native genes with the goal of enhancing bioproduct output. Although recent work has expanded the genetic toolkit for Z. mobilis , N. aromaticivorans and R. sphaeroides still need facile, reliable approaches to deliver genetic payloads to the genome and to control gene expression. Here, we expand the platform of genetic tools for N. aromaticivorans and R. sphaeroides to address these issues. We demonstrate that Tn 7 transposition is an effective approach for introducing engineered DNA into the chromosome of N. aromaticivorans and R. sphaeroides . We screen a synthetic promoter library to identify isopropyl β-D-1-thiogalactopyranoside-inducible promoters with regulated activity in both organisms (up to ~15-fold induction in N. aromaticivorans and ~5-fold induction in R. sphaeroides ). Combining Tn 7 integration with promoters from our library, we establish CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) interference systems for N. aromaticivorans and R. sphaeroides (up to ~10-fold knockdown in N. aromaticivorans and R. sphaeroides ) that can target essential genes and modulate engineered pathways. We anticipate that these systems will greatly facilitate both genetic engineering and gene function discovery efforts in these species and other Alphaproteobacteria. IMPORTANCE It is important to increase our understanding of the microbial world to improve health, agriculture, the environment, and biotechnology. For example, building a sustainable bioeconomy depends on the efficient conversion of plant material to valuable biofuels and bioproducts by microbes. One limitation in this conversion process is that microbes with otherwise promising properties for conversion are challenging to genetically engineer. Here we report genetic tools for Novosphingobium aromaticivorans and Rhodobacter sphaeroides that add to the burgeoning set of tools available for genome engineering and gene expression in Alphaproteobacteria. Our approaches allow straightforward insertion of engineered pathways into the N. aromaticivorans or R. sphaeroides genome and control of gene expression by inducing genes with synthetic promoters or repressing genes using CRISPR interference. These tools can be used in future work to gain additional insight into these and other Alphaproteobacteria and to aid in optimizing yield of biofuels and bioproducts.

Hall, Ashley N.↗

Identification of a p-Coumarate Degradation Regulon in Rhodopseudomonas palustris by Xpression, an Integrated Tool for Prokaryotic RNA-Seq Data Processing

High-throughput sequencing of cDNA prepared from RNA, an approach known as RNA-seq, is coming into increasing use as a method for transcriptome analysis. Despite its many advantages, widespread adoption of the technique has been hampered by a lack of easy-to-use, integrated, open-source tools for analyzing the nucleotide sequence data that are generated. Here we describe Xpression, an integrated tool for processing prokaryotic RNA-seq data. The tool is easy to use and is fully automated. It performs all essential processing tasks, including nucleotide sequence extraction, alignment, quantification, normalization, and visualization. Importantly, Xpression processes multiplexed and strand-specific nucleotide sequence data. It extracts and trims specific sequences from files and separately quantifies sense and antisense reads in the final results. Outputs from the tool can also be conveniently used in downstream analysis. In this paper, we show the utility of Xpression to process strand-specific RNA-seq data to identify genes regulated by CouR, a transcription factor that controls p -coumarate degradation by the bacterium Rhodopseudomonas palustris.

59 BASIC BIOLOGICAL SCIENCES↗

GradeIT (Road Grade Inference Tool)

The National Renewable Energy Laboratory (NREL) has developed the Road Grade Inference Tool, "GradeIT". This tool is a modular Python package the leverages the United States Geological Survey’s (USGS) 1/3 arc-second Digital Elevation Model (DEM), an open and free public dataset. Roadway gradient (slope) has a strong influence on vehicle energy consumption behavior and longitudinal dynamics. Therefore, any tools, models, or analyses that consider vehicle energy consumption or driving profiles is incomplete without accurate elevation and grade information. Despite the acute need for this data, it is rarely collected alongside GPS (latitude and longitude) data, and tools to post-process GPS data to append elevation and grade are difficult to come by. GradeIT satisfies this significant need in the research community. Utilization of the USGS DEM makes the underlying data available to any potential user and ensures continuous data anywhere in the continental United States. The USGS DEM is a great resource; however, in order to be useful for automotive and traffic engineering applications, significant interpolation and filtering is required to achieve an accurate representation of gradient on the roadway. GradeIT employs a two-dimensional interpolation to approximate elevation at a point on the road from the nearest nodes in the DEM. Then, GradeIT applies multiple filtering techniques to smooth the elevation profile to a realistic road topology. Finally, road grade is derived from the elevation profile and returned as the primary output.

Holden, Jacob↗

Residential Simulation Tool

Residential Simulation Tool was developed to understand the impact of residential load consumption on utilities including the role of demand response. This is complicated as many different residential loads exist and are utilized for different purposes. The tool models human behavior and contributes this to load utilization, which contributes to the electrical consumption prediction by the tool. The tool integrates a number of different databases from Department of Energy and other Government websites to support the load consumption prediction.

Starke, MichaelR↗

Oscillation Baselining and Analysis Tool

PNNL developed a new tool for oscillation analysis and baselining. This tool has been developed under a new DOE Grid Modernization Laboratory Consortium (GMLC) Project (GM0072 - “Suite of open-source applications and models for advanced synchrophasor analysis”) and it is based on the open platform for PMU analysis. The Oscillation Baselining and Analysis Tool (OBAT) performs the oscillation analysis and identifies modes of oscillations (frequency, damping, energy, and shape). The tool also does oscillation event baselining (fining correlation between oscillations characteristics and system operating conditions).

Source record↗

Frequency Response Tool

According to the North American Electric Reliability Corporation (NERC) definition: "Frequency response is a measure of an Interconnection's ability to stabilize frequency immediately following the sudden loss of generation or load, and is a critical component of the reliable operation of the Bulk-Power System, particularly during disturbances and recoveries. Failure to maintain frequency can disrupt the operation of equipment and initiate disconnection of power plant equipment to prevent it from being damaged, which could lead to wide-spread blackouts." Frequency Response Tool automates the power system frequency response analysis process. The tool performs initial estimation of the system frequency parameters (initial frequency, minimum frequency, settling point). User can visually inspect and adjust these parameters. The tool also calculates the frequency response performance metrics of the system, archives the historic events and baselines the system performance. Frequency response performance characteristics of the system are calculated using phasor measurement unit (PMU) information. Methodology of the frequency response performance assessment implemented in the tool complies with the NERC Frequency response standard.

Etingov, Pavel↗