Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Assessing First-Order Dependence of Thermolytic HGR on Glycolate at Low Glycolate Concentrations

This report describes the results of testing performed to investigate the assumed first-order behavior of glycolate at low concentrations in the current Glycolate Thermolytic Hydrogen Generation Rate (HGR) expression. Four experiments were performed at 100 °C using a simulant based on a Tank 28 supernate sample, and the glycolate concentration in the experiments ranged from 5 - 175 mg/L. The thermolytic HGR results from all tests were well-described by the current Glycolate Thermolytic HGR Model. A linear fit of the Ln(HGR) and Ln(Gly) gave a suggested reaction order of 1.15. Additionally, by taking into account prior knowledge on how varying chemistry impacts the HGR, a reaction order of 0.99 was obtained. Both cases suggest that the data validates the assumed first-order dependence of HGR on glycolate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustic-based monitoring and machine learning of component status for microreactor applications

This report provides a description and assessment of recent efforts to couple acoustic-based experimental measurements and characterization with machine learning models in order to enhance structural health monitoring capabilities for nuclear microreactors. With resilient embedded sensors in development by others supported by programs funded by the US Department of Energy’s Office of Nuclear Energy, the work described herein builds upon ongoing efforts to improve non-destructive testing technology that relates measured acoustic signatures to component stresses and/or structural defects, using a combination of new experimental measurements and machine learning architectures. The experimental procedure remained similar to that developed for the previous year’s demonstration of damage detection by the authors, with the same damaged sample tested under similar applied stress conditions. Notably, a new mounting fixture was designed and implemented to improve measurement consistency and a more sophisticated laser Doppler vibrometer was employed to make high-fidelity vibration measurements. Two nominally identical sets of training data were collected for each experimental setup to better understand the repeatability of the experiment and to better test the generality of trained neural network models. Additionally, we obtained new high-quality 3D mode shapes of the damaged test article at various stress and excitation levels, providing greater insights into the physical response of the sample during testing. Previously, we demonstrated that a machine learning model based on a convolutional neural network can predict structural details of an artificially introduced interface (intact, rough cut, smooth cut), and the applied torque level. In this study, we have transitioned to graph-based neural network architectures to better develop and test a flexible framework that is more suitable to being transferred away from controlled benchtop experiments and into more applied settings where less-structured data inputs may be expected. In general, performance testing of a graph neural network on frequency-domain representations of the data indicates strong and consistent identification of test conditions for datasets recorded on damaged components. With goals of predicting damage location and other changing experimental conditions using limited datasets, predictive models using a graph neural network architecture correctly predicted the applied torque level with an accuracy of 85% using only a single measurement point and predicted within one torque level in 95% of test windows. Predictions of damage location had limited success due to the symmetry and minimal number of the damage scenarios presented during model training. Results were ambiguous as to whether the model could detect the location of the artificial damage, or if it was instead learning the location of a given measurement point on the part and subsequently detecting which points were closest to the location of the damage. This finding will be factored into upcoming planned work on damaged graphite components, where new experimental tests with a larger number and variety of damage scenarios are expected to provide improved validation of recent developments in monitoring methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel Membrane-Based Corrosion Sensors For Operating In Natural Gas Pipelines

Membrane-based electrochemical sensors (MBES) provide an attractive option for real-time continuous humidity and corrosion rate measurements inside of natural gas pipelines. The MBES, can use electrochemical techniques such as linear polarization resistance and electrochemical impedance spectroscopy even when a conductive aqueous phase is intermittent or unavailable. We now present field-test performance data of our MBES operated inside a multiphase water and natural gas flow facility. The MBES measured internal corrosion and conductivity at the top, bottom, and side of the pipe spool. Tests were carried out with flow rates of 4.6, 9.1, and 18.3 m/s, temperatures of 21, 29, and 35 °C, and a pressure of 1000 psia. All sensors followed similar trends in open circuit potential, corrosion rate, and conductivity over time. Neither flow rate, temperature, nor build-up of metal-based solids on the sensor surfaces impacted the quality of the electrochemical measurements. The field-test results confirm that the membrane-based electrochemical sensors are suitable for monitoring internal corrosion of operational natural-gas pipelines.

Duffy, Timothy↗

Radiological Characterisation of VLLW Produced at High-Energy Particle Accelerators - 19118

In this paper we describe the characterisation method of very-low-level radioactive waste (VLLW) produced at the European Organization for Nuclear Research (CERN). The method is based on the calculation of a preliminary radionuclide inventory using either analytical or Monte Carlo codes, on the measurement of γ-emitters and on the quantification of pure-α, pure-β and low-energy X-ray emitters, called difficult-to-measure (DTM) radionuclides, using the so-called scaling factor (SF) technique. The first stage of the characterisation process is the calculation of the radionuclide inventory, which is a list of radionuclides that can potentially be produced via the interaction of primary and secondary particles with the surrounding media. Once the preliminary radionuclide inventory is obtained, the γ-emitting radionuclides are measured via γ-ray spectrometry on each package of the waste population. The major γemitter, called key nuclide (KN), is also identified. The scaling factor method estimates the activity of DTM radionuclides by checking for a consistent and repeated relationship between the key nuclide and the activity of the difficult to measure radionuclides from samples. Between 2016 and 2018, several hundred samples were collected at CERN and over 1000 radiochemical analyses were performed to estimate robust statistics to quantify scaling factors for the most common DTM radionuclides, such as H-3, Fe-55 and Ni-63. This paper illustrates the sample collection strategy, the tests performed to choose the most appropriate statistical models describing the behaviour of scaling factors and a complete quantification of the uncertainties associated with the characterisation process. Finally, we present the results obtained during the characterisation of over 2000 m{sup 3} radioactive metals and cables disposed of at the French National repository for VLLW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

Single Stage Contactor Testing Of The Next Generation Solvent Blend

The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Slide Test FY 2019 Report

At Los Alamos, the Slide Test was developed in 2019 to investigate whether the mass of a main charge of explosive sliding on a gritty surface, in the absence of impact, is sufficient to heat grit to ignition temperatures in PBX 9501. This is a practical test to address frictional ignition during assembly/disassembly operations at the Pantex Plant. Twenty-seven Slide Tests were performed in total, testing PBX 9501 at various slide velocities, grit diameters, grit patterns, and charge masses. Time-resolved velocimetry of the slide event (from PDV) and spot area of the explosive charge (obtained from image analysis) is reported. High-speed videography is used to diagnose explosive reaction. Eighteen of these tests were performed with a charge mass of 30 lbs at velocities ≤ 4 m s-1 and grit diameters between 75 and 1000 µm. Nine Slide Tests were performed with a 15 lb charge mass at similar parameters. No ignition was observed in any of the tests. These data provide evidence that the mass of a main charge, caused to slide on a surface at the low velocities achievable during routine handling, is insufficient stimulus to heat grit to ignition temperatures. These findings are relevant to risk assessment for explosive handling operations and provide evidence that PBX 9501 is safe within the constraints that were tested. However, because ignitions were not observed in any of the tests, we cannot determine which variables (mass or velocity) dominate the explosive response and to what extent. The absence of observed ignition also precludes the determination of a safety margin. To identify this safety margin, further research would be necessary to define the velocity and/or mass threshold at which ignition occurs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Hanford Supplemental Low Activity Waste Simulant Evaporation Testing for Removal of Organics

The Hanford site has approximately 56 million gallons of radioactive waste stored in 177 underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) is vitrification, but additional immobilization capacity is likely needed to supplement the initial melters. An alternative cementitious waste form is being investigated for that future supplemental immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste. Developing a method to remove the organics would eliminate that impediment to permit possible use of a cementitious waste form. Savannah River National Laboratory (SRNL) performed testing to examine evaporation as a method to remove some prevalent organics from the Supplemental LAW (SLAW) stream. Samples of product streams from the evaporation were analyzed to determine partitioning of the organics. Modeling was also performed to determine if the experimental and modeling results matched. A description of the experimental details, equipment, and results of that testing are included in this report.The work is intended to inform future SLAW flowsheet development activities and gather useful data about the partitioning of constituents through a possible SLAW feed evaporator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the Effects of the Rejuvenation Treatment on Mechanical and Microstructural Properties of IN-738 Superalloy

The main scope of this paper is to show the effects of a specific rejuvenation treatment studied for IN-38 on both the microstructure and the mechanical properties of the creep-damaged superalloy and to compare the tests results with the virgin material and with the recovery obtained through the standard heat treatment. This work will show that this rejuvenation treatment is able to recover the microstructure of creep-damaged specimens and that the creep and tensile properties of the rejuvenated alloy are even better than the virgin material for the tests performed. Moreover, it will be shown that the standard heat treatment provided for IN-738 is not able to fully recover the microstructure and that the creep properties of the superalloy during the tests have been lower than the virgin material.

36 MATERIALS SCIENCE↗

Probing the Degradation Mechanisms in Electrolyte Solutions for Li-ion Batteries by In-Situ Transmission Electron Microscopy

One of the goals in the development of new battery technologies is to find new electrolytes with increased electrochemical stability. In-situ (scanning) transmission electron microscopy ((S)TEM) using an electrochemical fluid cell provides the ability to rapidly and directly characterize electrode/electrolyte interfacial reactions under battery relevant electrochemical conditions. Furthermore, as the electron beam itself causes a localized electrochemical reaction when it interacts with the electrolyte, the breakdown products that occur during the first stages of battery operation can potentially be simulated and characterized using a straightforward in-situ liquid stage (without electrochemical biasing capabilities). In this paper, we have studied the breakdown of a range of inorganic/salt complexes that are used in state-of-the-art Li-ion battery systems. The results of the in-situ (S)TEM experiments matches with previous stability tests performed during battery operation and the breakdown products and mechanisms are also consistent with known mechanisms. This analysis indicates that in-situ liquid stage (S)TEM observations can be used to directly test new electrolyte designs and provide structural insights into the origin of the solid electrolyte interphase (SEI) formation mechanism.

25 ENERGY STORAGE↗

First Demonstration of Improved Fusion Yield with Increased Compression through Reduced Adiabat in Inertial Confinement Fusion Experiments at the National Ignition Facility

Recent advancements in indirect-drive inertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) have achieved a significant milestone by demonstrating target gains greater than one, yet future applications necessitate much higher target gains. One approach to achieving improved implosion performance is to pursue increased fuel compression via a lowered implosion adiabat. Experiments have been performed testing a reduced adiabat by introducing small changes to the drive laser pulse shape and the resulting shock timing for an existing implosion design at 1.9 MJ laser drive with near-ignition performance (experiment N210808). Experiments using the updated design demonstrate, for the very first time, increased compression and fusion yield in ICF implosions on the NIF by using a lower fuel adiabat, and increased compression with a reduced adiabat in high-density carbon ablators. Compared to the previously best-performing experiment with a laser energy of 1.9 MJ, these experiments exhibit increases of up to 80% and 14% in nuclear fusion yield and fuel compression, respectively, and with repeatable performance. Further, it is the only implosion design to have achieved a target gain exceeding one with a laser energy of less than 2 MJ. These findings highlight the efficacy of reduced adiabat designs in achieving higher compression and fusion yields, offering a promising pathway for future ICF applications. In conclusion, this Letter not only addresses a long-standing question in ICF but also paves the way for achieving higher target gains with optimized implosion strategies.

Hohenberger, M. [Lawrence Livermore National Labor↗

Integrated Data Collection Analysis (IDCA) Program - AN and Bullseye Smokeless Powder

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN) mixed with Bullseye® smokeless powder (Gunpowder). The participants found the AN/Gunpowder to: 1) have a range of sensitivity to impact, comparable to or less than RDX, 2) be fairly insensitive to friction as measured by BAM and ABL, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) have thermal sensitivity about the same as PETN and Gunpowder. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed when developing safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods. Note, however, the test procedures differ among the laboratories. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent. Keywords: Small-scale safety testing, proficiency test, impact-, friction-, spark discharge-, thermal testing, round-robin test, safety testing protocols, HME, RDX, potassium perchlorate, potassium chlorate, sodium chlorate, sugar, dodecane, PETN, carbon, ammonium nitrate, Gunpowder, Bullseye® smokeless powder.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Report #33: Compressor Calorimeter Test of R-410A Alternative: R-32/R-134a Mixture Using a Scroll Compressor

This report investigates the tested performance of lower - GWP candidate refrigerant, 94.07 wt% R - 32 + 5.93 wt % R - 134 a mixture (hereafter referred to as R - 32/134a), as an alternative to baseline refrigerant R - 410 A using a 36,000 Btu/hr compressor calorimeter located at the Heat Exchanger Advanced Testing Facility at Oak Ridge National Laboratory . These tests were conducted during May and August 2013. R - 410A is a near - azeotropic blend of R - 32 and R - 125 with 0.5/0.5 mass fraction and has a GWP 100 of 2100. R - 32 and R - 134a are pure refrigerants and have GWP 100 of 716 and 1370 1, respectively. Based on the GWP 100 values of pure refrigerants and their mass fraction in the blend, GWP 100 of R - 32/134a, which is under development by National Refrigerant, is 755. This report compares various performance parameters, such as cooling capacity, compressor power, refrigerant mass flow rate, EER, isentropic efficiency and discharge temperature of the alternative refrigerant to that of R - 410 A.

42 ENGINEERING↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Updated Liquid Secondary Waste Grout Formulation and Preliminary Waste Form Qualification

This report describes the results from liquid secondary waste grout (LSWG) formulation and cementitious waste form qualification tests performed by Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions, LLC (WRPS). New formulations for preparing a cementitious waste form from a high-sulfate liquid secondary waste stream simulant, developed for Effluent Management Facility (EMF) process condensates merged with low activity waste (LAW) caustic scrubber, and the release of key constituents (e.g. 99Tc and 129I) from these monoliths were evaluated. This work supports a technology development program to address the technology needs for Hanford Site Effluent Treatment Facility (ETF) liquid secondary waste (LSW) solidification and supports future Direct Feed Low-Activity Waste (DFLAW) operations. High-priority activities included simulant development, LSWG formulation, and waste form qualification. The work contained within this report relates to waste form development and testing and does not directly support the 2017 integrated disposal facility (IDF) performance assessment (PA). However, this work contains valuable information for use in PA maintenance past FY17, and for future waste form development efforts. The provided data should be used by (i) cementitious waste form scientists to further understanding of cementitious dissolution behavior, (ii) IDF PA modelers who use quantified constituent leachability, effective diffusivity, and partitioning coefficients to advance PA modeling efforts, and (iii) the U.S. Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program. The results obtained help fill existing data gaps, support final selection of a LSWG waste form, and improve the technical defensibility of long-term waste form performance estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Note: A method for minimizing oxide formation during elevated temperature nanoindentation

A standardized method to protect metallic samples and minimize oxide formation during elevated-temperature nanoindentation was adapted to a commercial instrument. Nanoindentation was performed on Al (100), Cu (100), and W (100) single crystals submerged in vacuum oil at 200 °C, while the surface morphology and oxidation was carefully monitored using atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The results were compared to room temperature and 200 °C nanoindentation tests performed without oil, in order to evaluate the feasibility of using the oil as a protective medium. Extensive surface characterization demonstrated that this methodology is effective for nanoscale testing.

36 MATERIALS SCIENCE↗

Computer-aided detection of breast masses: Four-view strategy for screening mammography

Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.

60 APPLIED LIFE SCIENCES↗