Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A comparison of two rocket borne Langmuir probes having electrodes of different materials

The behavior of two types of Langmuir probes, one with electrodes made of low-sulfur stainless steel and one with electrodes made of aluminum coated with Aquadag, has been compared on two rocket flights. Each rocket payload included one Langmuir probe of each type. The electron temperatures measured with the stainless-steel electrodes were about 15% higher than the electron temperatures measured with the Aquadag-coated electrodes at 150 km on ascent and about 10% higher at 180 km. These results imply that the use of Aquadag coated electrodes or electrodes of other carefully chosen materials permits greater reliability in the measurement of electron temperatures in the ionosphere by the Langmuir probe technique.

Schutz, S. R.↗

Characterization of Fluorescent Polystyrene Microspheres for Advanced Flow Diagnostics

Fluorescent dye-doped polystyrene latex microspheres (PSLs) are being developed for velocimetry and scalar measurements in variable property flows. Two organic dyes, Rhodamine B (RhB) and dichlorofluorescence (DCF), are examined to assess laser-induced fluorescence (LIF) properties for flow imaging applications and single-shot temperature measurements. A major interest in the current research is the application of safe dyes, thus DCF is of particular interest, while RhB is used as a benchmark. Success is demonstrated for single-point laser Doppler velocimetry (LDV) and also imaging fluorescence, excited via a continuous wave 2 W laser beam, for exposures down to 10 ms. In contrast, when exciting with a pulsed Nd:YAG laser at 200 mJ/pulse, no fluorescence was detected, even when integrating tens of pulses. We show that this is due to saturation of the LIF signal at relatively low excitation intensities, 4-5 orders of magnitude lower than the pulsed laser intensity. A two-band LIF technique is applied in a heated jet, indicating that the technique effectively removes interfering inputs such as particle diameter variation. Temperature measurement uncertainties are estimated based upon the variance measured for the two-band LIF intensity ratio and the achievable dye temperature sensitivity, indicating that particles developed to date may provide about +/-12.5 C precision, while future improvements in dye temperature sensitivity and signal quality may enable single-shot temperature measurements with sub-degree precision.

Maisto, Pietro M. F.↗

Thermal interfaces in dynamic compression experiments

Temperature is a difficult thermodynamic variable to measure in dynamic compression experiments. Optical pyrometry is a general-purpose technique for measuring temperature from a radiant surface, but that surface is often the interface between distinct materials with temperatures that vary spatially along the loading direction. This leads to a fundamental problem: how does the measured interface temperature relate to this temperature profile along the compression axis? Numerical analysis of loading history and thermal diffusion at these interfaces shows that seemingly subtle changes in experiment geometry can lead to very different temperature profiles. We compare these results to laboratory temperature measurements of shock-compressed tin.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of Dragonfly Entry Aerosciences Measurements (DrEAM)

Dragonfly Entry Aerosciences Measurements (DrEAM) is an instrumentation suite for the Dragonfly mission’s entry vehicle heat shield and backshell that satisfies NASA’s Engineering Science Investigation requirement for a New Frontiers mission. Key in-situ measurements will be made in Titan’s atmosphere for the first time. High level DrEAM project goals include the following: measure heat shield near surface and in-depth temperatures; measure backshell near surface and in-depth temperatures; measure pressure at the heat shield and backshell surface; and measure backshell radiative and total heat flux.

EDL↗

Development of High-Temperature Emissivity Measurement Capabilities for Molten Salts at PNNL

In this study, an emissivity measurement system for a liquid molten salt was developed on the bases on the Stefan Boltzmann Law. A prototype device operating in ambient atmosphere was constructed an initial result compared well with available literature. The diffuse emissivity of NaCl-KCl system (NaCl, 51mol% NaCl – 49mol% KCl and KCl) was measured from 550 to 850 °C at a wavelength of 1.3 µm. The system appears to be relatively invariant with composition but a clear trend of decreasing emissivity values from ~0.9 at 550 °C to 0.75 at 850 °C was observed. A schematic for an enclosed system for inert atmosphere and actinide salts was drafted. Several of the components for fabrication of this device, improved laser system, furnace, nickel for capsule construction, have been purchased and are ready for assembly. The new laser system will have an improved measurement range of 275-1000 °C. The clam shell furnace has a maximum temperature of 1200 °C and will support the hermetically sealed inert encapsulation vessels. Nickel plate and tubing will create a relatively corrosion resistance capsule for testing that can withstand temperature up to 1000 °C. Emissivity measurements are important for a larger effort to understand radiative heat transfer within molten salts at elevated temperatures (600-1000 °C). Literature review of optical salt properties and radiative heat transfer models indicated that systems within elevated temperature regimes could see upwards of 20% or more of their total heat transferred through photonic mechanisms. Ultimately, future work will measure the total thermal conductivity and break down the molecular and radiative portions. Thermal conductivity, along with other thermal properties of molten salts, both coolant and fuel, are fundamental to modeling and simulations that support MSR design. The results presented here and ongoing work at PNNL will be useful in selecting optimal salt compositions, designing reactor systems, and optimizing heat transfer within a MSR power plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flexible Multiplexed Surface Temperature Sensor

Unitary array of sensors measures temperatures at points distributed over designated area on surface. Useful in measuring surface temperatures of aerodynamic models and thermally controlled objects. Made of combination of integrated-circuit microchips and film circuitry. Temperature-sensing chips scanned at speeds approaching 10 kHz. Operating range minus 40 degrees C to 120 degrees C. Flexibility of array conforms to curved surfaces. Multiplexer eliminates numerous monitoring cables. Control of acquisition and recording of data effected by connecting array to microcomputers via suitable interface circuitry.

Daryabeigi, Kamran↗

Using optical fibers to examine thermal mixing of liquid sodium in a pool-type geometry

Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.

42 ENGINEERING↗

BOREAS RSS-17 Stem, Soil, and Air Temperature Data

The BOREAS RSS-17 team collected several data sets in support of its research in monitoring and analyzing environmental and phenological states using radar data. This data set consists of tree bole and soil temperature measurements from various BOREAS flux tower sites. Temperatures were measured with thermistors implanted in the hydroconductive tissue of the trunks of several trees at each site and at various depths in the soil. Data were stored on a data logger at intervals of either 1 or 2 hours. The majority of the data were acquired between early 1994 and early 1995. The primary product of this data set is the diurnal stem temperature measurements acquired for selected trees at five BOREAS tower sites. The data are provided in tabular ASCII format. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Zimmerman, Reiner↗

A Simple Transient Thermal Test Assembly for Insulation Materials

A simple transient thermal test was developed for evaluating the thermal performance of high-temperature flexible insulation materials in atmospheric pressure air. The test setup was inspired by the test assembly used for evaluating the performance of fire shelters and fire protective clothing. The heating source used was a burner supplied with propane gas that can generate relatively uniform heating over a wide area. The ratio of the in-plane width to thickness of the insulation test sample in the test assembly was selected to be greater than ten so that the heat transfer in the center of the test assembly was nearly one-dimensional. A rigid, thin Inconel plate was used as the septum plate directly exposed to the flame to provide a relatively uniform, known-temperature boundary condition for the test assembly, and to prevent convective heat transfer through the test insulation from the burner. The test sample, flexible alumina paper insulation, was placed between the Inconel plate and a thin titanium witness plate. The overall assembly was further insulated using a combination of rigid and flexible ceramic insulations to minimize heat losses from the periphery of the test assembly. Thermocouples installed on the septum and witness plates and inside the insulation test sample provided temperature measurements at various locations. For the evaluation tests, the Inconel septum plate reached temperatures between 780°C and 850°C for tests with flame exposure durations of 120 sec to 300 sec. The measured temperatures for various tests with similar flame exposure times were repeatable. A one-dimensional numerical heat transfer model of the test assembly was developed. The close agreement between measured and predicted temperatures on the titanium witness plate and inside the insulation test sample indicated that this test may provide a one-dimensional thermal testing capability for evaluation of thermal performance of similar insulations.

Daryabeigi, Kamran↗

Analysis of the NASA White Sands Test Facility (WSTF) Test System for Friction-Ignition of Metallic Materials

Friction is a known ignition source for metals in oxygen-enriched atmospheres. The test system developed by the NASA White Sands Test Facility in response to ASTM G-94 has been used successfully to determine the relative ignition from friction of numerous metallic materials and metallic materials pairs. These results have been ranked in terms of a pressure-velocity product (PV) as measured under the prescribed test conditions. A high value of 4.1(exp 8) watts per square meter for Inconel MA 754 is used to imply resistance to friction ignition, whereas a low value of 1.04(exp 8) watts per square meter for stainless steel 304 is taken as indicating material susceptible to friction ignition. No attempt has been made to relate PV values to other material properties. This work reports the analysis of the WSTF friction-ignition test system for producing fundamental properties of metallic materials relating to ignition through friction. Three materials, aluminum, titanium, and nickel were tested in the WSTF frictional ignition instrument system under atmospheres of oxygen or nitrogen. Test conditions were modified to reach a steady state of operation, that is applied, the force was reduced and the rotational speed was reduced. Additional temperature measurements were made on the stator sample. The aluminum immediately galled on contact (reproducible) and the test was stopped. Titanium immediately ignited as a result of non-uniform contact of the stator and rotor. This was reproducible. A portion of the stator sampled burned, but the test continued. Temperature measurements on the stator were used to validate the mathematical model used for estimating the interface (stator/rotor) temperature. These interface temperature measurements and the associate thermal flux into the stator were used to distinguish material-phase transitions, chemical reaction, and mechanical work. The mechanical work was used to analyze surface asperities in the materials and to estimate a coefficient of fiction. The coefficient of fiction was analyzed in terms of material properties that is, hardness, Young's modulus and elasticity/plasticity of the material.

Shoffstall, Michael S.↗

Elastic constants at low temperatures - Recent measurements on technological materials at NBS

Solid-state low-temperature elastic properties have been experimentally studied at the NBS Cryogenic Division for four years. Most studies were between room temperature and liquid-helium temperature; some were only to liquid-nitrogen temperature. Two dynamic (high-frequency) experimental methods were used, pulse-echo and resonance, resulting in adiabatic elastic constants. The present paper reviews these studies for 47 technological materials - metals, alloys, and composites. The elastic constants primarily discussed are Young's modulus, the shear modulus, the bulk modulus (reciprocal compressibility), and Poisson's ratio. A summary table is presented to show which base metals tend to exhibit regular, irregular, or anomalous behavior in their elastic constant/temperature curves.

Ledbetter, H. M.↗

Jet Exhaust Measurements

Shielded thermocouples for jet exhaust temperature measurements of resistojet thrustor in vacuum environment

JET EXHAUST↗

Comparison of flight-measured and calculated temperatures on the space shuttle orbiter

Structural temperatures and thermal protection system surface temperatures were measured on the space shuttle during the flight of STS 5. The measured data are compared with values calculated at wing stations 134, 240, and 328 and at fuselage station 877. The theoretical temperatures were calculated using the structural performance and resizing finite element thermal analysis program. The comparisons show that the calculated temperatures are, generally, in good agreement with the measured data.

Gong, Leslie↗

Effect of radiometric errors on accuracy of temperature-profile measurement by the spectral-scanning method.

The spectral-scanning method may be used to determine the temperature profile of a jet- or rocket-engine exhaust stream by measurements of gas radiation and transmittance at two or more wavelengths. A single, fixed line of sight is used, using immobile radiators and radiometers outside of the gas stream, and there is no interference with the flow. A given radiometric error causes an error in computed temperatures. The ratio between temperature error and radiometric error depends on profile shape, path length, temperature level, the strength of line absorption, and the absorption coefficient and its temperature coefficient. These influence the choice of wavelengths for any given gas. Conditions for minimum temperature error are derived. Numerical results are presented for a two wavelength measurement on a family of profiles that may be expected in a practical case of H2 - O2 combustion. Under favorable conditions, the fractional error in temperature approximates the fractional error in radiant-flux measurement.

Buchele, D. R.↗