Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

A sub-GeV charged-current quasi-elastic $\nu_{\mu}$ cross-section on carbon at SciBooNE

Neutrino-nucleus charged-current quasi-elastic scattering is the signal interaction used by many neutrino oscillation experiments. For muon disappearance studies the signal mode is ν μ n → μp. Modern oscillation experiments, such as T2K, produce neutrino beams with peak beam energies of order a few-GeV. It is therefore vitally important to have accurate measurements of the charged-current quasi-elastic crosssection for future neutrino oscillation experiments. Neutrino-nucleus cross-sections in the few-GeV region are not well understood, with the main uncertainties coming from understanding of the neutrino beam flux and the final state interactions within nuclei. SciBooNE is a sub-GeV neutrino-nucleus cross-section experiment based at Fermilab, Batavia, USA, with the goal to measure neutrino cross-sections with precision of order 5%. SciBooNE took data from June 2007 until August 2008, in total 0.99×10 20 and 1.53×10 20 protons on target were collected in neutrino and anti-neutrino mode, respectively. In this thesis a ν μ charged-current quasi-elastic (CCQE) cross-section contained within the SciBar sub-detector is presented. A method to tag muons in SciBar was developed and three samples were isolated. An excess in backwards tracks in the one-track sample is observed. A Poisson maximum likelihood is used to extract the CCQE cross-section. The fit was applied using a basic fit parameter model, successfully used to obtain the cross-section in the SciBar-MRD matched CCQE analysis. This method was found to be insufficient in describing the data for the SciBarcontained CCQE analysis. By adding two migration parameters the cross-section was calculated to be 1.004 ± 0.031 (stat) +0.101 -0.150 (sys) × 10 -38 cm 2 /neutron, excluding backwards tracks with a χ 2 = 203.8/76 d.o.f. and 1.083 ± 0.030(stat) +0.115 -0.177 (sys) × 10 -38 cm 2 /neutron, including backwards tracks with a χ 2 = 659.8/133 d.o.f. Only neutrino beam and detector systematics have been considered. Further study of the SciBar-contained sample is suggested, introducing additional fit parameters and considering the remaining systematics. The end goal is to extract a SciBooNE CCQE cross-section using the SciBar-contained and SciBar-MRD matched samples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Longitudinal monitoring adipose-derived stem cell survival by PET imaging hexadecyl-4-{sup 124}I-iodobenzoate in rat myocardial infarction model

Highlights: • We developed a safe, simple and appropriate stem cell labeling method with {sup 124}I-HIB. • ADSC survival can be monitored with PET in MI model via direct labeling. • Tracking of ADSC labeled with {sup 124}I-HIB was possible for 3 days in MI model using PET. • ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. • Survival of ADSC in living bodies can be longitudinally tracked with PET imaging. - Abstract: This study aims to monitor how the change of cell survival of transplanted adipose-derived stem cells (ADSCs) responds to myocardial infarction (MI) via the hexadecyl-4-{sup 124}I-iodobenzoate ({sup 124}I-HIB) mediated direct labeling method in vivo. Stem cells have shown the potential to improve cardiac function after MI. However, monitoring of the fate of transplanted stem cells at target sites is still unclear. Rat ADSCs were labeled with {sup 124}I-HIB, and radiolabeled ADSCs were transplanted into the myocardium of normal and MI model. In the group of {sup 124}I-HIB-labeled ADSC transplantation, in vivo imaging was performed using small-animal positron emission tomography (PET)/computed tomography (CT) for 9 days. Twenty-one days post-transplantation, histopathological analysis and apoptosis assay were performed. ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. In vivo tracking of the {sup 124}I-HIB-labeled ADSCs was possible for 9 and 3 days in normal and MI model, respectively. Apoptosis of transplanted cells increased in the MI model compared than that in normal model. We developed a direct labeling agent, {sup 124}I-HIB, and first tried to longitudinally monitor transplanted stem cell to MI. This approach may provide new insights on the roles of stem cell monitoring in living bodies for stem cell therapy from pre-clinical studies to clinical trials.

60 APPLIED LIFE SCIENCES↗

A modular and compact portable mini-endstation for high-precision, high-speed fixed target serial crystallography at FEL and synchrotron sources

The design and implementation of a compact and portable sample alignment system suitable for use at both synchrotron and free-electron laser (FEL) sources and its performance are described. The system provides the ability to quickly and reliably deliver large numbers of samples using the minimum amount of sample possible, through positioning of fixed target arrays into the X-ray beam. The combination of high-precision stages, high-quality sample viewing, a fast controller and a software layer overcome many of the challenges associated with sample alignment. A straightforward interface that minimizes setup and sample changeover time as well as simplifying communication with the stages during the experiment is also described, together with an intuitive naming convention for defining, tracking and locating sample positions. Lastly, the setup allows the precise delivery of samples in predefined locations to a specific position in space and time, reliably and simply.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP4-12: Real-Time Organ Motion Monitoring Using Ultrasound and KV Fluoroscopy During Lung SBRT Delivery

Purpose: Real-time ultrasound monitoring during SBRT is advantageous in understanding and identifying motion irregularities which may cause geometric misses. In this work, we propose to utilize real-time ultrasound to track the diaphragm in conjunction with periodical kV fluoroscopy to monitor motion of tumor or landmarks during SBRT delivery. Methods: Transabdominal Ultrasound (TAUS) b-mode images were collected from 10 healthy volunteers using the Clarity Autoscan System (Elekta). The autoscan transducer, which has a center frequency of 5 MHz, was utilized for the scans. The acquired images were contoured using the Clarity Automatic Fusion and Contouring workstation software. Monitoring sessions of 5 minute length were observed and recorded. The position correlation between tumor and diaphragm could be established with periodic kV fluoroscopy periodically acquired during treatment with Elekta XVI. We acquired data using a tissue mimicking ultrasound phantom with embedded spheres placed on a motion stand using ultrasound and kV Fluoroscopy. MIM software was utilized for image fusion. Correlation of diaphragm and target motion was also validated using 4D-MRI and 4D-CBCT. Results: The diaphragm was visualized as a hyperechoic region on the TAUS b-mode images. Volunteer set-up can be adjusted such that TAUS probe will not interfere with treatment beams. A segment of the diaphragm was contoured and selected as our tracking structure. Successful monitoring sessions of the diaphragm were recorded. For some volunteers, diaphragm motion over 2 times larger than the initial motion has been observed during tracking. For the phantom study, we were able to register the 2D kV Fluoroscopy with the US images for position comparison. Conclusion: We demonstrated the feasibility of tracking the diaphragm using real-time ultrasound. Real-time tracking can help in identifying such irregularities in the respiratory motion which is correlated to tumor motion. We also showed the feasibility of acquiring 2D KV Fluoroscopy and registering the images with Ultrasound.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric Effect of Online Image-Guided Anatomical Interventions for Postprostatectomy Cancer Patients

Purpose: To assess daily variations in delivered doses in postprostatectomy patients, using kilovoltage cone-beam CT (CBCT) datasets acquired before and after interventions to correct for observed distortions in volume/shape of rectum and bladder. Methods and Materials: Seventeen consecutive patients treated with intensity-modulated radiotherapy to the prostate bed were studied. For patients with large anatomical variations, quantified by either a rectal wall displacement of >5 mm or bladder volume change of >50% on the CBCT compared with the planning CT, an intervention was performed to adjust the rectum and/or bladder filling. Cumulative doses over the pre- and post-intervention fractions were calculated by tracking the position of the planning CT voxels on different CBCTs using a deformable surface-mapping algorithm. Dose and displacements vectors were projected on two-dimensional maps, the minimal dose received by the highest 95% of the planing target volume (PTV D95) and the highest 10% of the rectum volume (D10) as well as the bladder volume receiving >2 Gy (V2) were evaluated. Results: Of 544 fractions, 96 required intervention. Median (range) number of interventions per patient was 5 (2-12). Compared with the planning values, the mean (SD) pre- vs. postintervention value for PTV D95 was -2% (2%) vs. -1% (2%) (p < 0.12), for rectum D10 was -1% (4%) vs. +1% (4%) (p < 0.24), and for bladder V2 was +6% vs. +20% (p < 0.84). Conclusions: Interventions to reduce treatment volume deformations due to bladder and rectum fillings are not necessary when patients receive daily accurate CBCT localization, and the frequency of those potential interventions is low. However, for hypofractionated treatments, the relative frequency can significantly increase, and interventions can become more dosimetrically beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Eulerian adaptive finite-difference method for high-velocity impact and penetration problems

Owing to the complex processes involved, faithful prediction of high-velocity impact events demands a simulation method delivering efficient calculations based on comprehensively formulated constitutive models. Such an approach is presented herein, employing a weighted essentially non-oscillatory (WENO) method within an adaptive mesh refinement (AMR) framework for the numerical solution of hyperbolic partial differential equations. Applied widely in computational fluid dynamics, these methods are well suited to the involved locally non-smooth finite deformations, circumventing any requirement for artificial viscosity functions for shock capturing. Application of the methods is facilitated through using a model of solid dynamics based upon hyper-elastic theory comprising kinematic evolution equations for the elastic distortion tensor. The model for finite inelastic deformations is phenomenologically equivalent to Maxwell s model of tangential stress relaxation. Closure relations tailored to the expected high-pressure states are proposed and calibrated for the materials of interest. Sharp interface resolution is achieved by employing level-set functions to track boundary motion, along with a ghost material method to capture the necessary internal boundary conditions for material interactions and stress-free surfaces. The approach is demonstrated for the simulation of high velocity impacts of steel projectiles on aluminium target plates in two and three dimensions.

Barton, Philip T.↗

Heat shock protein-90-beta facilitates enterovirus 71 viral particles assembly

Molecular chaperones are reported to be crucial for virus propagation, but are not yet addressed in Human Enterovirus 71 (EV71). Here we describe the specific association of heat shock protein-90-beta (Hsp90β), but not alpha form (Hsp90α), with EV71 viral particles by the co-purification with virions using sucrose density gradient ultracentrifugation, and by the colocalization with viral particles, as assessed by immunogold electron microscopy. The reduction of the Hsp90β protein using RNA interference decreased the correct assembly of viral particles, without affecting EV71 replication levels. Tracking ectopically expressed Hsp90β protein associated with EV71 virions revealed that Hsp90β protein was transmitted to new host cells through its direct association with infectious viral particles. Our findings suggest a new antiviral strategy in which extracellular Hsp90β protein is targeted to decrease the infectivity of EV71 and other enteroviruses, without affecting the broader functions of this constitutively expressed molecular chaperone. - Highlights: • Hsp90β is associated with EV71 virion and is secreted with the release virus. • Hsp90β effects on the correct assembly of viral particles. • Viral titer of cultured medium was reduced in the presence of geldanamycin. • Viral titer was also reduced when Hsp90β was suppressed by siRNA treatment. • The extracellular Hsp90β was also observed in other RNA viruses-infected cells.

60 APPLIED LIFE SCIENCES↗

Search for the NΔ resonance in the 𝛾𝑑 → 𝑑𝜋 +𝜋 − reaction

A dibaryon which is an object with baryon number B = 2 has been studied for a long time. Dyson and Xuong classified non-strangeness dibaryon states based on SU(6) symmetries in 1960?s. In the framework, the deuteron is classified as one of the sextet states of dibaryons. Although dibaryon have been an interesting subject of research for a long time, most of the experimental studies up to the early 2000?s were unsuccessful. The CELCIUS/WASA collaboration reported this state via the double-pionic fusion reaction (?= ! 3c0c0) in 2009. Thereafter, the WASA-at-COSY collaboration revealed properties of the isoscaler resonance state via the ?= ! 3c0c0 reaction in 2011. The dibaryon resonance state with isospin ? = 0 and spin ( = 3 thought to be a ?03 which was predicted by Dyson and Xuong at 2.35 GeV?22 with a configuration of ??. The reported mass and width of that state were 2?37 GeV?22 and 0?07 GeV?22, espectively. The mass was ?0?08 GeV?22 smaller than that of 2?, the width was narrower than that of single ?. This surprising result made dibaryon study come back into the limelight. ?12 is one of the dibaryon states classified by Dyson and Xuong with isospin ? = 1, spin ( = 2. This state can be regarded as an s-wave #? resonance. ?12 is an interesting state from the point of view of the possibilities of existence as an internal structure of ?03 and contribution to many-body effects in nuclei. Though there were some experimental clues and theoretical studies of this state, it was unclear whether the obtained experimental results represented a real resonance or not due to the difficulty of separation from kinematical effects. Very recently, the FOREST group at Tohoku University reported a photoproduced isovector dibaryon state at mass of 2.14 GeV?22 in the 3c0 invariant mass spectra of the W3 ! 3c0c0 reaction. The most probable ?% configuration was 2¸ although they didn?t exclude the possibility of ?% = 1¸ or 3?. They separated the dibaryon production process from conventional pion production process for the first time using angular distribution of deuteron. We investigated the W3 ! 3c¸c? reaction for study of a possible #? dibaryon state using a deuterium target at the Research Center for Electron Photon Science, Tohoku University, Japan. In the experiment, ?3 ? 1012 tagged photon beam at energies ranging from 0.8 to 1.1 GeV was impinged to the liquid deuterium target (?520 mg?cm2) and the charged particles in the final state: deuteron, c¸, and c?, were detected by a magnetic spectrometer with a large solid angle named NKS2. NKS2 had capabilities of reconstructing momentum of charged particles, multi-track analysis, and ??c separation. We performed two different analyses named 2-track analysis and 3-track analysis. The 2-track (3-track) analysis was for events in which two (three) particles of 3c¸c? in the final state, including deuteron, were detected by NKS2. In the 3-track and 2-track analysis, ?2000? ?15000 events were identified as the W3 ! 3c¸c? reaction events, respectively. The 2-track analysis with higher statistics was mainly used to derive the cross sections, and the 3-track analysis was used to check the consistency of the 2-track analysis. In this thesis, we have shown the total cross section, the differential cross sections of the W3 ! 3c¸c? reaction in the region of jC j ¡ 0?15 GeV2. This is the world?s first measurement of this reaction in this energy region. Dibaryon resonance structures were observed below the #? threshold in the differential cross section of the invariant mass of 3c?. The mass and width of the structure were consistent with these of ?12 measured by the W3 ! 3c0c0 reaction. The mechanism of the production process was discussed based on the angular distribution of emitted deuteron.

Toyama, Yuichi↗

Development of a biomarker for Geobacter activity and strain composition; Proteogenomic analysis of the citrate synthase protein during bioremediation of U(VI).

Monitoring the activity of target microorganisms during stimulated bioremediation is a key problem for the development of effective remediation strategies. At the U.S. Department of Energy’s Integrated Field Research Challenge (IFRC) site in Rifle, CO, the stimulation of Geobacter growth and activity via subsurface acetate addition leads to precipitation of U(VI) from groundwater as U(IV). Citrate synthase (gltA) is a key enzyme in Geobacter central metabolism that controls flux into the TCA cycle. Here, we utilize shotgun proteomic methods to demonstrate that the measurement of gltA peptides can be used to track Geobacter activity and strain evolution during in situ biostimulation. Abundances of conserved gltA peptides tracked Fe(III) reduction and changes in U(VI) concentrations during biostimulation, whereas changing patterns of unique peptide abundances between samples suggested sample-specific strain shifts within the Geobacter population. Abundances of unique peptides indicated potential differences at the strain level between Fe(III)-reducing populations stimulated during in situ biostimulation experiments conducted a year apart at the Rifle IFRC. These results offer a novel technique for the rapid screening of large numbers of proteomic samples for Geobacter species and will aid monitoring of subsurface bioremediation efforts that rely on metal reduction for desired outcomes.

54 ENVIRONMENTAL SCIENCES↗

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

42 ENGINEERING↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

Molecular Aspects of Transport in Thin Films of Controlled Architecture

Our laboratory focuses on developing spatially localized chemistries which can produce structures of controlled architecture on the supermolecular length scale -- structures which allow us to control the motion of molecular species with high spatial resolution, ultimately on nanometer length scales. Specifically, nanocapillary array membranes (NCAMs) contain an array of nanometer diameter pores connecting vertically separated microfluidic channels. NCAMs can manipulate samples with sub-femtoliter characteristic volumes and attomole sample amounts and are opening the field of chemical analysis of mass-limited samples, because they are capable of digital control of fluid switching down to sub-attoliter volumes; extension of analytical “unit operations” down to sub-femtomole sample sizes; and exerting spatiotemporal control over fluid mixing to enable studies of reaction dynamics. Digital flow switching mediated by nanocapillary array membranes can be controlled by bias, ionic strength, or pore diameter and is being studied by observing the temporal characteristics of transport across a single nanopore in thin PMMA membranes. The control of flow via nanopore surface characteristics, charge density and functional group presentation, is being studied by coupled conductivity and laser-induced fluorescence (LIF) measurements. Reactive mixing experiments previously established low millisecond mixing times for NCAM-mediated fluid transfer, and this has been exploited to demonstrate capture of mass-limited target species by Au colloids. Voltage and thermally-activated polymer switches have been developed for active control of transport in NCAMs. Thermally-switchable and size-selective transport was achieved by grafting poly(N-isopropylacrylamide) brushes onto the exterior surface of a Au-coated polycarbonate track-etched membrane, while the voltage-gated properties of poly(hydroxyethylmethacrylate) were characterized dynamically. Electrophoretic separations have been coupled to analyte sampling both by LIF and mass spectrometry. Detection of electrophoresis separation products by electrospray mass spectrometry was achieved through direct interfacing to an electrospray mass spectrometer. Pb(II) interactions with the DNAzyme have been realized in an NCAM-coupled integrated microfluidic structure allowing cation separations to be coupled to molecular beacon detection motifs for the determination of Pb(II) in an electroplating sludge reference material. By changing the DNAzyme to select for other compounds of interest, it is possible to incorporate multiple sensing systems within a single device, thereby achieving great flexibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-EF-303-05: Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy

Purpose: To realize real-time-image gated proton beam therapy (RGPT) for treating mobile tumors. Methods: The rotating gantry of spot scanning proton beam therapy has been designed to equip two x-ray fluoroscopy devices that enable real-time imaging of the internal fiducial markers during respiration. Three-dimensional position of the fiducial marker located near the tumor can be calculated from the fluoroscopic images obtained from orthogonal directions and therapeutic beam is gated only when the fiducial marker is within the predefined gating window. Image acquisition rate can be selected from discrete value ranging from 0.1 Hz to 30 Hz. In order to confirm the effectiveness of RGPT and apply it clinically, clinical commissioning was conducted. Commissioning tests were categorized to main three parts including geometric accuracy, temporal accuracy and dosimetric evaluation. Results: Developed real-time imaging function has been installed and its basic performances have been confirmed. In the evaluation of geometric accuracy, coincidence of three-dimensional treatment room coordinate system and imaging coordinate system was confirmed to be less than 1 mm. Fiducial markers (gold sphere and coil) were able to be tracked in simulated clinical condition using an anthropomorphic chest phantom. In the evaluation of temporal accuracy, latency from image acquisition to gate on/off signal was about 60 msec in typical case. In dosimetric evaluation, treatment beam characteristics including beam irradiation position and dose output were stable in gated irradiation. Homogeneity indices to the mobile target were 0.99 (static), 0.89 (w/o gating, motion is parallel to direction of scan), 0.75 (w/o gating, perpendicular), 0.98 (w/ gating, parallel) and 0.93 (w/ gating, perpendicular). Dose homogeneity to the mobile target can be maintained in RGPT. Conclusion: Real-time imaging function utilizing x-ray fluoroscopy has been developed and commissioned successfully in order to realize RGPT. Funding Support: This research was partially supported by Japan Society for the Promotion of Science (JSPS) through the FIRST Program. Conflict of Interest: Prof. Shirato has research fund from Hitachi Ltd, Mitsubishi Heavy Industries Ltd and Shimadzu Corporation.

60 APPLIED LIFE SCIENCES↗

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of further calibration factors to be applied. The final accuracy of implantable MOSFETs when used for such kind of treatments was estimated to be within {+-}4%. Additional investigations using dose/fraction higher than 12 Gy, different beam configurations, and tracking systems could extend the present findings to other kind of treatments. MOSFET technology was proven to have high versatility in fast adaptation of existing detectors to new applications. It is plausible to expect a general feasibility of implantable MOSFET technology for in vivo dosimetry of the extracranial-targets treatments using the Cyberknife, provided each particular application will be validated by suitable both physical and clinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Challenges in Tracking Waste Reduction Performance Improvement in Manufacturing Plants

The recently released Circularity Gap Report 2023 by the Circle Economy Foundation states that the circularity score for the global economy is declining. The US Environmental Protection Agency (EPA) tracked municipal solid waste from 1960 to 2018 and found that 50% of the waste was destined for landfills. EPA estimates that US industry is responsible for 2.7 Gt of solid nonhazardous waste annually in the US mostly linear economy model. The circular economy framework aims to decouple economic value generation from the extraction of virgin materials from nature. The linear model of material extraction and disposal at the end of life is highly unsustainable. Manufacturing companies are adopting ambitious waste reduction targets to achieve sustainability. Through the Better Plants program, US DOE has established the Waste Reduction Network, which offers technical assistance to partners to achieve their ambitious waste reduction goals. Basic requirements of establishing a target include identifying a baseline, quantifying waste performance, and measuring progress over time. One problem faced by industry is unstandardized metrics for quantifying waste performance that may not be well suited to demonstrate progress. This paper studies traditional methods used to measure waste performance and highlights advantages, disadvantages, and limitations of each method. It also examines the suitability of applying the methods in different manufacturing circumstances. Finally, the paper presents a case study of a large manufacturer that faced inconsistencies in its tracked measurement metric. A solution was proposed and implemented to alter the methodology to enable more accurate waste performance tracking against a baseline.

circular economy↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photoproduction of the Λ(1520) hyperon with a 9 GeV photon beam at GlueX

The GlueX experiment is located at the Thomas Jefferson National Accelerator Facility (JLab) in Newport News, VA, USA. It features a hermetic 4π detector with excellent tracking and calorimetry capabilities. Its 9 GeV linearly polarized photon beam is produced from the 12 GeV electron beam, delivered by JLab’s Continuous Electron Beam Accelerator Facility (CEBAF), via bremsstrahlung on a thin diamond and is incident on a LH2 target. GlueX recently finished its first data taking period and published first results. The main goal of GlueX is to measure gluonic excitations of mesons. These so-called hybrid or exotic mesons are predicted by Quantum Chromodynamics (QCD) but haven’t been experimentally confirmed yet. They can have quantum numbers not accessible by ordinary quark-antiquark pairs which helps in identifying them using partial wave analysis techniques. The search for exotic mesons requires a very good understanding of photoproduction processes in a wide range of final states, one of them being pK + K - which contains many meson and baryon reactions. The Λ(1520) is a prominent hyperon resonance in this final state and is the subject of this presentation. This talk will give an introduction to the GlueX experiment and show preliminary results for the photoproduction of the Λ(1520) hyperon. The measurement of important observables like the photon beam asymmetry and spin-density matrix elements will be discussed and an outlook to possible measurements of further hyperon states in the pK + K - final state will be given.

Pauli, Peter↗

Adjoint Waveform Tomography for Crustal and Upper Mantle Structure of the Middle East and Southwest Asia for Improved Waveform Simulations Using Openly Available Broadband Data

Here we present a new model of radially anisotropic seismic wavespeeds for the crust and upper mantle of a broad region of the Middle East and Southwest Asia (MESWA) derived from adjoint waveform tomography. The new model enables fully 3D simulations of complete three-component waveforms and provides improved fits that were not possible with previous models. We inverted over 32,000 waveforms from 192 earthquakes recorded by over 1000 openly available broadband seismic stations from permanent and temporary networks in the region with highly uneven coverage. Inversion iterations proceeded from the period band 50–100 s in six stages and 54 total iterations reducing the minimum period to 30 s. Our final model, MESWA, improves waveform fits compared to the starting and other models for both the data used in the inversion and an independent validation set of 66 events. Restitution tests indicate that the model resolves features in the central part of the model to depths of about 150 km. The new model reveals tectonic features imaged by other studies and methods but in a new holistic model of anisotropic shear and compressional wavespeeds (V S and V P , respectively) covering a larger domain with smaller scale length and amplified features. Examples include low crustal V S in the Tethyan belt and low mantle VS following divergent (Gulf of Aden, Red Sea) and transform (Dead Sea fault) margins of the Arabian plate. Low V S is imaged below Cenozoic volcanic centers of the Mecca–Madina–Nafud Line, Arabian Peninsula, and the Türkiye–Iran border region. Elevated V S tracks Makran subduction under southeast Iran with near vertical dip. MESWA could be used as a starting model for further improvements, say, using waveforms from in-country seismic networks that are not currently openly available and/or smaller-scale studies targeting a shorter period. The model could be used to improve earthquake hazard studies and nuclear explosion monitoring.

58 GEOSCIENCES↗