Investigation of an anomalous flow condition of the Langley pilot model expansion tube

Free-stream flow velocity measurements were made in the Langley pilot model expansion tube during the test flow interval. During this interval, an anomalous dip in pitot pressure occurs for the expansion tube operating conditions employed. Within the test flow interval, the main conclusions reached from comparison of the measured flow velocity, pitot pressure, and tube wall pressure are: the variations which occur in velocity and wall pressure are small compared with the variations in pitot pressure; a corresponding dip in the derived flow density is associated with the dip in pitot pressure; and the value of the average density over the interval, which results from the expansion from the shocked intermediate chamber condition, is approximately one-half of the value that can result from only an isentropic process.

Friesen, W. J.↗

A finite-difference solution for unsteady wave interactions with an application to the expansion tube

An analytical study of the unsteady wave interaction of a shock wave overtaking a previously initiated shock tube flow has been conducted for a real gas by solving a finite-difference representation of the one-dimensional Navier-Stokes equations. This analysis has been used to determine the effect on the available test time of opening the secondary diaphragm in the expansion-tube operating cycle prior to the arrival of the incident shock wave. Special emphasis is placed on determining expansion-tube test-time limitations resulting from a nonuniform entropy distribution occurring during the early test-gas flow due to the varying Mach number of the incident shock wave as it traverses the expansion fan caused by the preopening process. Time distributions of velocity, temperature, pressure, and entropy at various distances from the diaphragm are presented as a function of the time required to open the diaphragm.

Weilmuenster, K. J.↗

A composite model for a class of electric-discharge shock tubes

A gasdynamic model is presented and analyzed for a class of shock tubes that utilize both Joule heating and electromagnetic forces to produce high-speed shock waves. The model consists of several stages of acceleration in which acceleration to sonic conditions is achieved principally through heating, and further acceleration of the supersonic flow is obtained principally through use of electromagnetic forces. The utility of the model results from the fact that it predicts a quasi-steady flow process, mathematical analysis is straightforward, and it is even possible to remove one or more component stages and still have the model related to a possible shock-tube flow. Initial experiments have been performed where the electrical discharge configuration and current level were such that Joule heating was the dominant form of energy addition present. These experiments indicate that the predictions of the model dealing with heat addition correspond quite closely to reality. The experimental data together with the theory show that heat addition to the flowing driver gas after diaphragm rupture (approach used in the model) is much more effective in producing high-speed shock waves than heating the gas in the driver before diaphragm rupture, as in the case of the arc-driven shock tube.

Elkins, R. T.↗

Development of an annular arc accelerator shock tube driver

An annular arc accelerator (ANAA) shock tube driver has been developed that deposits the energy of an arc discharge into a flowing gas, which then expands and cools without any delay for the opening of a diaphragm. A simplified one-dimensional flow analysis of the ANAA shock tube has been performed, which indicates that shock velocities greater than 40 km/sec may be obtained using a 300-kJ capacitor bank. The ANAA driver consists of a high-pressure driver, an expansion section, and an electrode section. In operation, the cold gas driver is pressurized until the diaphragm bursts, sending a pressure front down the expansion tube to the arc section. When the accelerated flow arrives at the electrode section, a 100-capacitor, 300-kJ capacitor bank is discharged either by breaking an insulating diaphragm between the electrodes or by the triggering of a series of external switches. Shock velocities of 28 km/sec have been obtained, and modifications are described that are expected to improve performance.

Leibowitz, L. P.↗

Study of Permanent Magnet Focusing for Astronomical Camera Tubes

A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

Long, D. C.↗

Permanent and separable aerospace tubing/ fitting evaluation program, volume 1

The tube fitting evaluation program was conducted to develop a standard overall test program including methods, procedures, and equipment as well as recommended test sequences for qualifying fitting/tubing assemblies. The program consisted of testing the MS flareless (separable) fitting and utilizing the results as baseline data from which all other fittings will be evaluated. Five separable designs and five permanent designs were tested in three sizes with two types of tubing materials. The basic design requirements were 4,000 psi operating pressure within the temperature range of minus 65 F to plus 450 F while also being compatible with 21-6-9 and titanium 3Al-2.5V tubing alloys.

Ursell, C. R.↗

Calibration of image dissector tubes

Technique employs computer-controlled light-emitting diode (LED), precision machined mask, and analog-to-digital coverter (ADC). Computer turns on LED which floods masked face of tube. Intensity pattern, generated as tube is electromagnetically swept, is fed to ADC which controls tube calibration.

Klingman, E. E., III↗

Roll-forming tubes to header plates

Technique has been developed for attaching and sealing tubes to header plates using a unique roll-forming tool. Technique is useful for attaching small tubes which are difficult to roll into conventional grooves in header plate tube holes, and for attaching when welding, brazing, or soldering is not desirable.

Kramer, K.↗

Incident shock-wave characteristics in air, argon, carbon dioxide, and helium in a shock tube with unheated helium driver

Incident shock-wave velocities were measured in the Langley 6-inch expansion tube, operated as a shock tube, with air, argon, carbon dioxide, and helium as test gases. Unheated helium was used as the driver gas and most data were obtained at pressures of approximately 34 and 54 MN/sq m. A range of pressure ratio across the diaphragm was obtained by varying the quiescent test-gas pressure, for a given driver pressure, from 0.0276 to 34.5 kN/sq m. Single- and double-diaphragm modes of operation were employed and diaphragms of various materials tested. Shock velocity was determined from microwave interferometer measurements, response of pressure transducers positioned along interferometer measurements, response of pressure transducers positioned along the driven section (time-of-arrival gages), and to a lesser extent, measured tube-wall pressure. Velocities obtained from these methods are compared and limitations of the methods discussed. The present results are compared with theory and the effects of diaphragm mode (single or double diaphragm), diaphragm material, heating of the driver gas upon pressurization of the driver section, diaphragm opening time, interface mixing, and two-dimensional (nonplanar) flow are discussed.

Miller, C. G., III↗

Effects of 1- and 2-MeV electrons on photomultiplier tubes

Various types of photomultiplier tubes useful for space applications were irradiated with 1- and 2-MeV electrons at Van Allen radiation belt fluxes of 100,000 to 10 millions electrons/sq cm-sec. The increase in the dark current due to electron irradiation was observed at various bias voltages under worst-case conditions (no shielding). Results were presented in the form of dark current plotted against electron flux. All the tubes tested showed extremely large increases in dark current. Tube types 541A, 6217, 6199, and 6903 exhibited the largest increases under irradiation, whereas type 1P22 was affected the least. All the damage observed was transient. The luminescence produced in the optical window probably accounts for a large part of the dark-current increases, but there were some effects possibly due to direct irradiation of the photocathode and dynode chain.

Beatty, M. E., III↗

Development of a high power 12GHz PPM focused traveling wave tube

An analytical and experimental program to demonstrate the technical feasibility of a high efficiency coupled cavity traveling wave tube with periodic permanent magnetic focusing operating at 12.06 GHz, with 1 to 2 kilowatts CW power is described. Such a tube would ultimately be used for broadcasting power transmission from a satellite. The electron gun was designed to be demountable with a replaceable cathode, and the tube to be operable in a bakeable vacuum chamber with its collector replaced by a collector. Therefore, the high efficiency design was concerned with the slow wave structure only, utilizing velocity resynchronization. A special adapter was designed which incorporated an electromagnet refocusing section and a collector baseplate to facilitate testing the collector. CW output power of 1000 watts yielding 21.5% electronic efficiency was demonstrated, with a minimum output power of 525 watts across the specified 160 MHz bandwidth.

Lewis, R.↗

Wave propagation along a magnetic tube

Motivated by the filamentary structure of solar magnetic fields, this paper considers the propagation of quasi-longitudinal waves along a slender magnetic tube in pressure equilibrium with the ambient medium. The velocity of such waves is expressed in terms of the Alven speed and the sound speed inside the tube. The divergence of a vertical magnetic tube in a stratified atmosphere introduces a critical frequency below which propagation is impossible.

Defouw, R. J.↗

Inspection tool for butt-welded tubing

Inspection tool for tubing consists of metal casing housing elastic collar. Collar is clamped around weld site under test. Leakage through weld is contained within chamber and is bled to detector via tubing attached to fitting. Tool, originally designed to detect fluid leakage in tubing, can be used to detect gas leaks.

Horman, D. P.↗

Traveling-wave tube reliability estimates, life tests, and space flight experience

Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.

Lalli, V. R.↗

High speed electrostatic photomultiplier tube for the 1.06 micrometer wavelength. Cup and slat dynode chain combined with flat cathode and coax output produces 0.25 nsec rise time

The Varian cup and slat dynode chain was modified to have a flat cathode. These modifications were incorporated in an all-electrostatic photomultiplier tube having a rise time of 0.25 n sec. The tube delivered under the contract had a flat S-20 opaque cathode with a useful diameter of 5 mm. The design of the tube is such that a III to V cathode support is mounted in place of the existing cathode substrate. This cathode support is designed to accept a transferred III to V cathode and maintain the cathode surface in the same position as the S-20 photocathode.

Sparks, S. D.↗

A 200 Watt Traveling Wave-Tube for the Communications Technology Satellite

This final report presents the results of the design, development, and test of experimental and production units of a PPM focused traveling wave tube (L-5394) that produces 225 watts of CW RF power over 85 MHz centered at 12.080 GHz. The tube uses a coupled cavity RF circuit with a velocity taper for greater than 26 percent basic efficiency. Overall efficiency of 50 percent is achieved by the incorporation of a multistage depressed collector designed at NASA Lewis Research Center. The collector is cooled by direct radiation to deep space. The tube was designed to be used for broadcasting power transmission from a satellite.

Jones, C. L.↗

Measurement of insulation integrity of IUE camera tube facsimiles by partial discharges method and diffusion of gases through various silicone rubbers

Several dummy tubes imitating the IUE Camera System design were encapsulated with Solithane 2, Conathane EN-11, Green and Black Hysols and SMRD 432. Various flaws were purposefully placed in some of these. Partial discharge testing in vacuum under direct voltage conditions was carried once a week for 12 weeks, 15 kv dc being applied during normal working hours for 40 hours duration per week. None of the units showed much damage during this time judging by the P.D. energy histograms. A more complete mathematical presentation is given on diffusion and permeation than previously. Measurements of diffusion constants for various silicone rubbers are carried out by the Time-Lag method and compared to other determinations in the literature. Calculations of the time required for diffusion through a thick wall are demonstrated in the long time approximation and for dimensions pertaining to void and wall sizes of a delamination problem in the LANDSAT-C vidicon tubes. An actual delaminated LANDSAT-C tube and some facsimiles are immersed in vacuum for long periods and tested for catastrophic breakdown due to diffusion of gas, by application of high voltage.

Bever, R. S.↗