Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

True Airspeed Measurement by Ionization-Tracer Technique

Ion bundles produced in a pulse-excited corona discharge are used as tracers with a radar-like pulse transit-time measuring instrument in order to provide a measurement of airspeed that is independent of all variables except time and distance. The resulting instrumentation need not project into the air stream and, therefore, will not cause any interference in supersonic flow. The instrument was tested at Mach numbers ranging from 0.3 to 3.8. Use of the proper instrumentation and technique results in accuracy of the order of 1 percent.

Boyd, B.↗

Coherent amplification of X-ray scattering from meso-structures

Small-angle X-ray scattering (SAXS) often includes an unwanted background, which increases the required measurement time to resolve the sample structure. This is undesirable in all experiments, and may make measurement of dynamic or radiation-sensitive samples impossible. Here, we demonstrate a new technique, applicable when the scattering signal is background-dominated, which reduces the requisite exposure time. Our method consists of exploiting coherent interference between a sample with a designed strongly scattering `amplifier'. A modified angular correlation function is used to extract the symmetry of the interference term; that is, the scattering arising from the interference between the amplifier and the sample. This enables reconstruction of the sample's symmetry, despite the sample scattering itself being well below the intensity of background scattering. Thus, coherent amplification is used to generate a strong scattering term (well above background), from which sample scattering is inferred. We validate this method using lithographically defined test samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-situ measurement of sensitivity for a piezoelectric sensor

The paper presents a technique for the in situ and real-time measurement of sensitivity change in a piezoelectric accelerometer. This technique involves the electrical stimulation of the accelerometer's piezoelectric element in a 'diagnostic' frequency band and the measurement of the frequency response of the sensor's electromechanical properties. It is found that changes in the piezomechanical properties of a compression-mode accelerator, as measured by the autocalibration function, detected a relative change in sensitivity.

Flanagan, Patrick M.↗

Spatial Correlation of Solar-Wind Turbulence from Two-Point Measurements

Interplanetary turbulence, the best studied case of low frequency plasma turbulence, is the only directly quantified instance of astrophysical turbulence. Here, magnetic field correlation analysis, using for the first time only proper two-point, single time measurements, provides a key step in unraveling the space-time structure of interplanetary turbulence. Simultaneous magnetic field data from the Wind, ACE, and Cluster spacecraft are analyzed to determine the correlation (outer) scale, and the Taylor microscale near Earth's orbit.

Matthaeus, W. H.↗

Biological responses to engineered nanomaterials: Needs for the next decade

In this study, the interaction of nanomaterials with biomolecules, cells, and organisms is an enormously vital area of current research, with applications in nanoenabled diagnostics, imaging agents, therapeutics, and contaminant removal technologies. Yet the potential for adverse biological and environmental impacts of nanomaterial exposure is considerable and needs to be addressed to ensure sustainable development of nanomaterials. In this Outlook four research needs for the next decade are outlined: (i) measurement of the chemical nature of nanomaterials in dynamic, complex aqueous environments; (ii) real-time measurements of nanomaterial-biological interactions with chemical specificity; (iii) delineation of molecular modes of action for nanomaterial effects on living systems as functions of nanomaterial properties; and (iv) an integrated systems approach that includes computation and simulation across orders of magnitude in time and space.

59 BASIC BIOLOGICAL SCIENCES↗

Transient vibration and product formation of photoexcited CS 2 measured by time-resolved x-ray scattering

Here, we have observed details of the internal motion and dissociation channels in photoexcited carbon disulfide (CS 2 ) using time-resolved x-ray scattering (TRXS). Photoexcitation of gas-phase CS 2 with a 200 nm laser pulse launches oscillatory bending and stretching motion, leading to dissociation of atomic sulfur in under a picosecond. During the first 300 fs following excitation, we observe significant changes in the vibrational frequency as well as some dissociation of the C–S bond, leading to atomic sulfur in the both 1 D and 3 P states. Beyond 1400 fs, the dissociation is consistent with primarily 3 P atomic sulfur dissociation. This channel-resolved measurement of the dissociation time is based on our analysis of the time-windowed dissociation radial velocity distribution, which is measured using the temporal Fourier transform of the TRXS data aided by a Hough transform that extracts the slopes of linear features in an image. The relative strength of the two dissociation channels reflects both their branching ratio and differences in the spread of their dissociation times. Measuring the time-resolved dissociation radial velocity distribution aids the resolution of discrepancies between models for dissociation proposed by prior photoelectron spectroscopy work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Floor and ceiling effects in the EORTC QLQ-C30 Physical Functioning subscale among patients with advanced or metastatic breast cancer

The European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire Core 30 Physical Functioning subscale is a widely used patient-reported outcome measure that quantifies cancer patients' physical functioning. Strong floor/ceiling effects can affect a scale's sensitivity to change. The aim of this study was to characterize floor/ceiling effects of the physical functioning domain in patients with advanced/metastatic breast cancer enrolled in commercial clinical trials and a community-based trial. The clinical trial cohort comprised patients from 5 registrational trials submitted to the Food and Drug Administration for review (2010-2017). The community cohort comprised a subgroup of patients from the Alliance Patient Reported Outcomes to Enhance Cancer Treatment (PRO-TECT) trial. The distribution of patient responses to Physical Functioning items and the summed score were assessed at the baseline and 3-month follow-up for both cohorts. Descriptive statistics were used to determine floor/ceiling effects at the item and scale levels. The clinical trial cohort and the community cohort consisted of 2407 and 178 patients, respectively. Twenty-four percent or more of the respondents reported “not at all” for having trouble/needing help with each Physical Functioning item across both cohorts and measurement time points. Fourteen to twenty percent of the patients scored perfectly (100 of 100) on the Physical Functioning subscale summary measure (where higher scores indicated better physical functioning) across both cohorts and time points. Minor floor effects and notable ceiling effects were found at the item and scale levels of the Physical Functioning subscale, regardless of cohort, and this creates some uncertainty about its ability to detect changes in physical functioning among high-functioning patients. In conclusion, investigators may consider adding additional high-functioning items from the EORTC's item library to more accurately describe the impact of anticancer treatment on patients' physical functioning.

60 APPLIED LIFE SCIENCES↗

Design and Construction of A Cerenkov Counter for In Situ Monitoring of Sr-90 in Groundwater

Migration of groundwater contamination from beneath the U.S. Department of Energy’s Hanford Site into the Columbia River creates a need for in situ 90Sr monitoring. The prototype monitor discussed here is designed for deployment inside a monitoring well and provides near-real-time determination of the 90Sr concentration in a two-liter groundwater sample. The measurement is made by direct detection of Cerenkov light generated in the water by beta decay of the 90Y daughter. This manuscript presents results from a prototype monitor that was designed by a parametric Monte Carlo simulation study. Calibration and testing results of the as-built system show near perfect agreement between simulated predictions and experimental results. Downwell and laboratory tests demonstrate that the prototype monitor is sensitive to 90Sr at concentrations below drinking water standards of 8 pCi/l (0.3 Bq/l) at the 90% confidence level in measurement times of less than four hours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transport studies in high-performance field reversed configuration plasmas

A significant improvement of field reversed configuration (FRC) lifetime and plasma confinement times in the C-2 plasma, called High Performance FRC regime, has been observed with neutral beam injection (NBI), improved edge stability, and better wall conditioning [Binderbauer et al., Phys. Plasmas 22, 056110 (2015)]. A Quasi-1D (Q1D) fluid transport code has been developed and employed to carry out transport analysis of such C-2 plasma conditions. The Q1D code is coupled to a Monte-Carlo code to incorporate the effect of fast ions, due to NBI, on the background FRC plasma. Numerically, the Q1D transport behavior with enhanced transport coefficients (but with otherwise classical parametric dependencies) such as 5 times classical resistive diffusion, classical thermal ion conductivity, 20 times classical electron thermal conductivity, and classical fast ion behavior fit with the experimentally measured time evolution of the excluded flux radius, line-integrated density, and electron/ion temperature. The numerical study shows near sustainment of poloidal flux for nearly 1 ms in the presence of NBI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved inertial confinement fusion gamma reaction history 12 C gamma-ray signal by direct subtraction

The Gamma Reaction History Diagnostic (GRH) located at the National Ignition Facility (NIF) measures time resolved gamma rays released from inertial confinement fusion experiments by converting emitted gamma rays into Cherenkov light. Imploded capsules have a bright 4.4 MeV gamma ray from fusion neutrons inelastically scattering with carbon atoms in the remaining ablator. The strength of 4.4 MeV gamma ray line is proportional to the capsule’s carbon ablator areal density and can be used to understand the dynamics and energy budget of a carbon-based ablator capsule implosion. Historically, the GRH’s four gas cells use the energy thresholding from the Cherenkov process to forward fit an estimation of the experiment’s complete gamma ray spectrum by modeling the surrounding environment in order to estimate the 4.4 MeV neutron induced carbon gamma ray signal. However, the high number of variables, local minima and uncertainties in detector sensitivities and relative timing had prevented routine use of the forward fit to generate carbon areal density measurements. A new, more straightforward, process of direct subtraction of deconvolved signals was developed to simplify the extraction of the carbon areal density. Beryllium capsules are used as a calibration to measure a capsule environment with no carbon signal. This is then used to appropriately subtract and isolate the carbon signal on shots with carbon ablators. The subtraction algorithm achieves good results across all major capsule campaigns, achieving similar results to the forward fit. This method is now used routinely to measure carbon areal density for NIF shots.

47 OTHER INSTRUMENTATION↗

Wavelength Dispersive X-ray Fluorescence Analysis of Actinides in Dissolved Nuclear Fuels

There is an urgent need for an instrument that can quickly measure the concentration of Plutonium and other Actinides mixed with Uranium in liquids containing dissolved spent fuel rods. Parallax Research, Inc. proposes to develop an x-ray spectrometer capable of measuring U, Np and Pu in dissolved nuclear fuel rod material to less than 10 ppm levels to aid in material process control for these nuclear materials. Due to system noise produced by high radioactivity, previous x-ray spectrometers were not capable of low level measurements but the system Parallax proposed has no direct path for undesired radiation to get to the detector and the detector in the proposed device is well shielded from scatter and has very low dark current. In addition, the proposed spectrometer could measure these three elements simultaneously, also measuring background positions with an energy resolution of roughly 100 eV making it possible to see a small amount of Pu that would be hidden under the tail of the U peak in energy dispersive spectrometers. Another nearly identical spectrometer could be used to target Am and Cm if necessary. The proposed spectrometer needs only a tiny sample of roughly 1 micro-liter (1 mm 3 ) and the measurement can be done with the liquid flowing in a radiation and chemical immune quartz capillary protected by a stainless steel rod making it possible to continuously monitor the liquid or to use a capillary manifold to measure other liquid streams. Unlike other methods such as mass spectroscopy where the sample must be taken to a remote facility and might take days for turn-around, the proposed measurement should take less than an hour. This spectrometer could enable near real-time measurement of U, Pu and Np in dilute dissolved spent nuclear fuel rod streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design Optimization for Printed Melt Wire Arrays Encapsulation

As part of the Nuclear Energy Enabling Technology (NEET) Advanced Sensor and Instrumentation (ASI) Program, Idaho National Laboratory (INL) has recently established in-house capabilities to fabricate and test new advanced-manufactured sensors for measuring peak irradiation temperature within a nuclear test reactor. Although methods of real-time temperature monitoring, such as thermocouples, may be used, the complexity of feedthroughs and attachments to collect real-time measurements greatly increases the cost of the experiment. Instead, passive monitoring techniques may be used for peak- temperature measurement that exploit the melting point of well-characterized materials (standard melt wires) to infer peak reactor temperatures. However, limited available space for instrumentation during experiments introduces an additional challenge. To accommodate this, INL has expanded its temperature- detection instrumentation capabilities to include advanced manufactured (AM) melt wires for peak irradiation temperature measurements. These melt wires can determine peak temperatures while also accommodate space limitations in irradiation experiments. In an effort to improve performance reliability of AM meltwire capabilities, a process was developed and tested to identify the significance of entrapping a high purity inert atmosphere within the packaging of printed melt wire arrays. The materials used in this study were aluminum, zinc, and tin encapsulated in high purity helium within a stainless steel (SS) 316 container. Tin, with a low melting point of approximately 230°C, Zn with a mid-melting point of approximately 420°C, and Al with a high melting point of approximately 660°C. This report describes the design, fabrication process, furnace testing and X-ray Computed Tomography (XCT) evaluation. Results show a successful outcome in creating an inert gas encapsulation and high-resolution evaluation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increased gait unsteadiness in community-dwelling elderly fallers

OBJECTIVE: To test the hypothesis that quantitative measures of gait unsteadiness are increased in community-dwelling elderly fallers. STUDY DESIGN: Retrospective, case-control study. SETTING: General community. PARTICIPANTS: Thirty-five community-dwelling elderly subjects older than 70 years of age who were capable of ambulating independently for 6 minutes were categorized as fallers (age, 82.2 +/- 4.9 yrs [mean +/- SD]; n = 18) and nonfallers (age, 76.5 +/- 4.0 yrs; n = 17) based on history; 22 young (age, 24.6 +/- 1.9 yrs), healthy subjects also participated as a second reference group. MAIN OUTCOME MEASURES: Stride-to-stride variability (standard deviation and coefficient of variation) of stride time, stance time, swing time, and percent stance time measured during a 6-minute walk. RESULTS: All measures of gait variability were significantly greater in the elderly fallers compared with both the elderly nonfallers and the young subjects (p < .0002). In contrast, walking speed of the elderly fallers was similar to that of the nonfallers. There were little or no differences in the variability measures of the elderly nonfallers compared with the young subjects. CONCLUSIONS: Stride-to-stride temporal variations of gait are relatively unchanged in community-dwelling elderly nonfallers, but are significantly increased in elderly fallers. Quantitative measurement of gait unsteadiness may be useful in assessing fall risk in the elderly.

NASA Discipline Cardiopulmonary↗

Distinguishing Research Reactor Fuels Using Neutron Multiplicity - 25615

Neutron measurements are one of the reliable means of interrogation of fissile material. Neutron measurements are used for total counting (pure metal fissile samples) or counting coincidence/multiplicity (for impure fissile samples). Various flavors of neutron measurement are used routinely by the IAEA to determine the fissile mass of an unknown sample. The objective of this work is to design an experiment to distinguish the two different fuel types using neutron multiplicity method. The design of experiment is performed using Monte Carlo N- Particle (MCNP) transport code. General Electric (GE) designed 1-MWt pool-type research reactor at UMass Lowell (UMLRR) uses Materials Testing Reactor (MTR) plate-type fuel consisting of 19 full and 2 partial fuel assemblies, controlled by four boron control blades and one regulating control rod. Two different fuel types are available at the UMLRR facility. In 2008, UMass Lowell obtained slightly burnt fuel assemblies from the decommissioned WPI research reactor. The simulation results discussed in this paper show that within the limits of statistical error, the single and double moments for the WPI and UMLRR fuels can be measured. The two fuels have very similar composition and enrichments resulting in very similar neutron multiplicity moments. This implies that neutron multiplicity measurements alone would not be sufficient to distinguish between the two fuel types at low burnups. The change in the observed single-double ratio between each fuel type is less than 6 % which falls below the uncertainty in the efficiency of the JCC71 slab detectors. The neutron signature from low burnup and low enriched uranium fuel are not strong, however, these can be measured under low background and long measurement times. This would be an important consideration in designing the experiments and parallel gamma measurements will also be planned. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Visualizations of Travel Time Performance Based on Vehicle Reidentification Data

This paper provides a visual reference of the breadth of arterial performance phenomena based on travel time measures obtained from reidentification technology that has proliferated in the past 5 years. These graphical performance measures are revealed through overlay charts and statistical distribution as revealed through cumulative frequency diagrams (CFDs). With overlays of vehicle travel times from multiple days, dominant traffic patterns over a 24-h period are reinforced and reveal the traffic behavior induced primarily by the operation of traffic control at signalized intersections. A cumulative distribution function in the statistical literature provides a method for comparing traffic patterns from various time frames or locations in a compact visual format that provides intuitive feedback on arterial performance. The CFD may be accumulated hourly, by peak periods, or by time periods specific to signal timing plans that are in effect. Combined, overlay charts and CFDs provide visual tools with which to assess the quality and consistency of traffic movement for various periods throughout the day efficiently, without sacrificing detail, which is a typical byproduct of numeric-based performance measures. These methods are particularly effective for comparing before-and-after median travel times, as well as changes in interquartile range, to assess travel time reliability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Atomic Oxygen Fluence Monitor

This innovation enables a means for actively measuring atomic oxygen fluence (accumulated atoms of atomic oxygen per area) that has impinged upon spacecraft surfaces. Telemetered data from the device provides spacecraft designers, researchers, and mission managers with real-time measurement of atomic oxygen fluence, which is useful for prediction of the durability of spacecraft materials and components. The innovation is a compact fluence measuring device that allows in-space measurement and transmittance of measured atomic oxygen fluence as a function of time based on atomic oxygen erosion yields (the erosion yield of a material is the volume of material that is oxidized per incident oxygen atom) of materials that have been measured in low Earth orbit. It has a linear electrical response to atomic oxygen fluence, and is capable of measuring high atomic oxygen fluences (up to >10(exp 22) atoms/sq cm), which are representative of multi-year low-Earth orbital missions (such as the International Space Station). The durability or remaining structural lifetime of solar arrays that consist of polymer blankets on which the solar cells are attached can be predicted if one knows the atomic oxygen fluence that the solar array blanket has been exposed to. In addition, numerous organizations that launch space experiments into low-Earth orbit want to know the accumulated atomic oxygen fluence that their materials or components have been exposed to. The device is based on the erosion yield of pyrolytic graphite. It uses two 12deg inclined wedges of graphite that are over a grit-blasted fused silica window covering a photodiode. As the wedges erode, a greater area of solar illumination reaches the photodiode. A reference photodiode is also used that receives unobstructed solar illumination and is oriented in the same direction as the pyrolytic graphite covered photodiode. The short-circuit current from the photodiodes is measured and either sent to an onboard data logger, or transmitted to a receiving station on Earth. By comparison of the short-circuit currents from the fluence-measuring photodiode and the reference photodiode, one can compute the accumulated atomic oxygen fluence arriving in the direction that the fluence monitor is pointing. The device produces a signal that is linear with atomic oxygen fluence using a material whose atomic oxygen erosion yield has been measured over a period of several years in low-Earth orbit.

Banks, Bruce A.↗

Verification of Triso Fuel Burnup Using Machine Learning Algorithms

Pebble Bed Reactors are fueled with fuel pebbles that are circulated multiple times through the reactor vessel before discharge. During the normal operation of a PBR, ejected pebbles are returned to the reactor or discharged depending on the fuel burnup and physical condition of the pebbles. The burnup measurement is usually based on detected radiation signatures of fission products accumulated in the pebble fuel over burnup. Previous research has shown that height of photopeaks of fission products, such as 134 Cs, 137 Cs, 154 Eu, etc., can be used independently or in combination to infer or predict the level of burnup in the fuel. However, it remains challenging to measure such complex sources due to self-shielding effects, strong radiation background and intervening materials. Another operational challenge is the required high throughput of burnup measurement, which necessitates limited measurement time and thus impacts quality of measured gamma-ray spectra. Hence, advanced spectral analysis methods are needed to analyze the noisy gamma spectra and predict the burnup values. We propose to use machine learning (ML) method to interpret gamma-ray spectra and predict the burnup values of the pebbles. ML has achieved widespread success and adoption across a few domains that require pattern recognition and analysis in varied data types. In this work, we apply three proven ML approaches - multilayer perceptrons, convolutional neural networks, and transformers - to the task of predicting fuel burnup from measured gamma spectra, and compile a dataset of simulated spectra for training and validation of the ML models. In this paper, we will discuss the network architecture of these three ML approaches and compare the performance of the simplest of these (MLP) to a standard linear regression.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗