Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL HYDRAULICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Prediction of Thermal Protection System Material Permeability and Hydraulic Tortuosity Factor Using Direct Simulation Monte Carlo

Carbon preforms used in Thermal Protection System (TPS) materials are 80 to 90% porous, allowing for boundary layer and pyrolysis gases to flow through the porous regions. The bulk material properties such as permeability and hydraulic tortuosity factor affect the transport of the boundary layer gases. The use of Direct Simulation Monte Carlo along with the Klinkenberg permeability formulation allows us to compute the continuum permeability and Knudsen correction factor for flow in the transition regime. In this work, we have computed the permeability for two types of carbon preforms, namely, Morgan Felt and FiberForm, and assessed the effect of orientation on the permeability. Since both the materials are anisotropic, the permeability was found to depend on orientation, wherein, the materials are more permeable in the in-plane orientation than the through-thickness orientation. The through-thickness orientation was also more tortuous compared to the in-plane material orientation. Compared to Morgan Felt, FiberForm is less permeable, in both, through thickness and in-plane directions.

Jambunathan, Revathi↗

Safe Affordable Fission Engine-(SAFE-) 100a Heat Exchanger Thermal and Structural Analysis

A potential fission power system for in-space missions is a heat pipe-cooled reactor coupled to a Brayton cycle. In this system, a heat exchanger (HX) transfers the heat of the reactor core to the Brayton gas. The Safe Affordable Fission Engine- (SAFE-) 100a is a test program designed to thermally and hydraulically simulate a 95 Btu/s prototypic heat pipe-cooled reactor using electrical resistance heaters on the ground. This Technical Memorandum documents the thermal and structural assessment of the HX used in the SAFE-100a program.

Steeve, B. E.↗

Thermal Stimulation and Injectivity Testing at Raft River, ID EGS Site

The Raft River geothermal field is the site of an innovative Department of Energy Enhanced Geothermal System (EGS) project to determine the viability of using combined thermal and hydraulic stimulation techniques to improve energy production. Well RRG-9 is currently undergoing a stimulation program using injectate from the US Geothermal Raft River Power Plant and cold water from a cooling tower make-up water well. The stimulation began on 13 June 2013 with injection from the power plant at a temperature of about 39 °C and a pressure of 275 psig. Next, two positive displacement plunger type pumps were used to increase the injection pressure and flow rate for about one month. The highest rate achieved was 258 gpm at a pressure of 741 psig. During this time, fluid from the cooler water well was injected for about 2 weeks at various pressures. Then, the pumps were removed and plant injection resumed on 25 September. Plant injection will continue until the spring of 2014, when a high pressure hydraulic stimulation will be conducted. A series of seismic monitoring stations deployed around the well are providing data on seismic events occurring at the site. Over the past year, 51 microseismic events have been recorded, all less than Magnitude 1. During injection, several diagnostic tests were conducted to gain a better understanding of the well and reservoir. A step-rate test was performed on 22 August to measure the in-situ stress and aid in modeling in-situ fractures. A tracer was injected into the well on 9 September. No tracer was detected in adjacent production wells after several months. A second borehole televiewer survey was conducted for comparison to pre-stimulation images. Here, a third borehole televiewer survey is planned after the high pressure stimulation. Injection test data is evaluated in real time. A modified Hall plot analysis indicates the effective permeability is increasing. The injectivity index supports the results of the modified Hall plot analysis. As the thermal stimulation has continued, the injectivity index has consistently followed an upward trend from 0.1 gpm/psi to 0.53 gpm/psi.

enhanced geothermal systems↗

TEDS Test Plan for Performance Characterization of Packed-bed Thermal Energy Storage Unit

This report proposes a set of test plans for performance measurement and characterization of the packed-bed thermal energy storage (TES) unit for TEDS. The main goals of this test plan are three-fold: (i) support the high-fidelity data measurement for TEDS, (ii) characterize thermal and structural performance of the TEDS TES unit, and (iii) produce high quality validation-oriented data. To achieve the goals, it is first suggested to revisit the instrument calibration and data sampling protocols applied during the startup and commissioning tests of TEDS, based on the observation from the recent CFD validation study using the TEDS TES operational data. The uncertainty quantification of the thermal and hydraulic measurements is also suggested. Lastly, test matrices are provided for charge, discharge, and standby modes of the packed-bed TES unit, respectively, to characterize the thermal and structural performances during the envisioned TEDS operations.

25 ENERGY STORAGE↗

Temperature Oscillations in Loop Heat Pipes - A Revisit

Three types of temperature oscillation have been observed in the loop heat pipes. The first type is an ultra-high frequency temperature oscillation with a period on the order of seconds or less. This type of temperature oscillation is of little significance in spacecraft thermal control because the amplitude is in the noise level. The second type is a high frequency, low amplitude temperature oscillation with a period on the order of seconds to minutes and an amplitude on the order of one Kelvin. It is caused by the back-and-forth movement of the vapor front near the inlet or outlet of the condenser. The third type is a low frequency, high amplitude oscillation with a period on the order of hours and an amplitude on the order of tens of Kelvin. It is caused by the modulation of the net heat load into the evaporator by the attached large thermal mass which absorbs and releases energy alternately. Several papers on LHP temperature oscillation have been published. This paper presents a further study on the underlying physical processes during the LHP temperature oscillation, with an emphasis on the third type of temperature oscillation. Specifically, equations governing the thermal and hydraulic behaviors of LHP operation will be used to describe interactions among LHP components, heat source, and heat sink. The following sequence of events and their interrelationship will also be explored: 1) maxima and minima of reservoir and thermal mass temperatures; 2) the range of the vapor front movement inside the condenser; 3) rates of change of the reservoir and thermal mass temperatures; 4) the rate of heat absorption and heat release by the thermal mass and the rate of vapor front movement; and 5) inflection points of the reservoir and thermal mass temperatures.

Fluid Mechanics and Thermodynamics↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Coupled Thermo–Hydro–Mechanical Modeling of Hydro-Shearing Stimulation in an Enhanced Geothermal System in the Raft River Geothermal Field, USA

The Raft River Enhanced Geothermal System (EGS) demonstration project aims to improve the geothermal production by enhancing the reservoir permeability via shear stimulation in well RRG-9. In this paper, we performed a series of 3D thermo– hydro–mechanical (THM) simulations to investigate the influence of hydraulic and thermal effects on the development of this EGS. The model includes synthetic fracture populations based on borehole televiewer images and in-situ stress measurements from well RRG-9. Fracture permeability evolution is determined using an empirical permeability law developed from laboratory experiments. The model was calibrated by comparing the hydraulic response to field observations, including wellhead pressure, injection rate, and well injectivity. Particularly, we analyzed the enhancement of reservoir permeability and the spatial extent of the stimulation zone for the given injection schedule. Our results indicate that the permeability enhancement of fractured geothermal reservoir is caused by the combined effects of injection-induced cooling and fluid pressure increase. The decrease of temperature plays a dominant role in reactivation of natural fractures under the hydro-shearing mechanism, while the higher injection pressure promotes shear failure and enlarges the stimulation zone. Finally, for the specified extensional stress state, the model favors greatest permeability enhancement along the maximum horizontal principal stress, a moderate vertical enhancement, and a smaller gain along the minimum horizontal principal stress.

58 GEOSCIENCES↗

Performance of Flight Compatible Microlith® Catalytic Oxidizer for Exploration Trace Contaminant Control

Precision Combustion, Inc. (PCI) and NASA Marshall Space Flight Center have been developing, characterizing, and optimizing prototype high temperature catalytic oxidizers based on PCI’s patented Microlith® technology and long-term endurance test data to meet the requirements of future spaceflight exploration missions. Based on the demonstrated performance (20,000+ hours) of a subscale prototype, a next-generation prototype was designed to meet exploration contaminant load control demands while upgrading the prototype form and fit to match flight-compatible interfaces. Prototype design considerations intended to minimize power consumption, impacting process thermal and hydraulic performance, are discussed herein. We also report on performance characteristics of the catalytic oxidizer and future efforts for component packaging and light-weighting.

Trace Contaminants↗

A high-performance lung-inspired ceramic 3D-printed heat exchanger for high-temperature energy-efficient systems

The thermal-to-electric conversion efficiency of next-generation supercritical carbon dioxide and concentrated solar power plants is significantly augmented by operating at temperatures exceeding 1000 °C if durable, compact, high-temperature heat exchangers (HXs) are developed. Whereas metal 3D-printed HXs fail to operate under extreme temperature conditions, ceramic 3D-printed HXs are deemed promising candidates for high-temperature, highly oxidizing environments. Ceramic 3D-printed HXs, however, exhibit a high gas permeability issue through hot and cold separating walls due to an excessive non-volatile photopolymer content utilized. Here, in this work, a novel leak-free lung-inspired ceramic 3D-printed HX employing a highly complex heat transfer topology is introduced for high-temperature energy-efficient systems. The high permeability issue of ceramic 3D-printed HXs is fully eliminated through a uniform zinc-based coating. It was determined that the effective thermal conductivity of the sintered ceramic heat exchangers is affected by the coated layer. The high-temperature thermal and hydraulic characteristics of the lung-inspired ceramic 3D-printed HX are comprehensively examined and compared against a millichannel 3D-printed HX module. Experimental results indicated that the lung-inspired 3D-printed ceramic HX significantly outperforms its millichannel counterpart. The lung-inspired HX shows a volume-based power density of 8.2 MW/m3 at a hot-side inlet air temperature of 700°C, a 71 % improvement compared with that of the millichannel HX. More importantly, the higher thermal duty of the lung-inspired 3D-printed HX is realized at a lower normalized pressure drop penalty of 510 Pa/W, 22 % lower than that of the millichannel ceramic HX. This study accelerates the advancement of high-performance ceramic 3D-printed HXs with complex topologies for high-temperature energy-efficient systems and/or corrosive environments.

42 ENGINEERING↗

Simulation of Peach Bottom turbine trip transients TT1, TT2 and TT3 with SIMULATE-3K

The Peach Bottom 2 Turbine Trip transients tests TT1, TT2 and TT3 are simulated with SIMULATE-3K. This work provides the initial basis for evaluation of the capabilities and accuracy of coupled 3D neutronics/thermal hydraulics best estimate calculations for support of safety analysis. Selected results, obtained with SIMULATE-3K, are compared to available measurements and benchmark results. The comparisons are analyzed and the application of SIMULATE-3K for best estimate analysis approach within the safety analysis methodology is discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Well-Controlled Hydro-thermo-chemical Stimulation of a Coso Geothermal Well to Enhance Productivity

The goal of this project was to demonstrate controlled fracturing and permeability increase to enhance resource production and power generation at Coso. It was planned to stimulate at least two intervals in the Well 73-18RD with zonal isolation using advanced high-temperature packer technology. The anticipation was that a hydraulic fracture would form in one zone and in the second zone natural fractures would reopen, shear and extend, thereby increasing fluid communication in the field. In both cases, the intent was to carefully design the stimulation to take advantage of the relative roles of hydraulic pressure, thermal stress and chemical (“hydro-thermo-chemical”) dissolution. The project had planned to use the Welltec Annular Barrier (WAB) system developed as part of another DOE-funded project which was on schedule to be ready for field deployment. If successful, the Coso Operating Company would incorporate this approach into their ongoing well maintenance in other wells increasing the total MWs produced. The project had multiple tasks and the objective of Task 1 was to develop a workover plan, to build a geologic model, to design a stimulation program, and to work with the operating and services companies to develop a detailed budget and obtain the necessary permits and sundry notices. In Phase 2 the workover plan would be implemented, the designed stimulation would be carried out, and subsequently the well would logged and tested to measure the impact of stimulation. Per sponsor request, a Pre-Task 1 activity with a Go/No Go decision point was scheduled in Task 1.

02 PETROLEUM↗

Machine learning-based optimization of air-cooled heat sinks

Machine learning-based models using Artificial Neural Network (ANN) and greedy search algorithm are used to optimize air-cooled parallel plate-finned heat sinks (PPFHSs) subjected to laminar flow over an extensive range of design parameters. Here, the thermal and hydraulic performances of PPFHSs are represented by heat transfer coefficient (h) and pressure drop (ΔP), respectively. Optimization objectives for PPFHS designs can vary from industry to industry depending on their design priorities. The present study proposes a novel and generalized optimization method that defines practical optimization objectives and provides an accurate optimization process to design effective PPFHSs for a wide range of industrial applications with different design requirements. Three optimization objectives are presented in this study: (i) the largest h PΔ, (ii) the largest h within a specified maximum allowed flow rate, and (iii) the lowest weight that maximizes h for operation within the maximum allowed flow rate. While the shortcoming of the first objective is demonstrated, the other two objectives are found to be suitable for designing effective heat sinks (HSs) across different applications. Results suggest a promising trend from the third objective to develop HSs with ~ 37-68% lower weight, 80-85% reduced ΔP, and negligible penalty in h compared with optimized HSs obtained from the second objective. However, since the third objective leads to HSs with thinner fins, structural analysis should be performed to ensure reliable operation of the HSs.

42 ENGINEERING↗

An international study on THM modelling of the full-scale heater experiment at Mont Terri laboratory

We present results from an international model comparison study of the Full-Scale Emplacement (FE) experiment in Opalinus Clay at the Mont Terri Laboratory, Switzerland. Based on a provided parameter set the teams decided which parameters they adopted for their models, whether they considered the excavation and the ventilation phase in addition to the heating phase and if they included technical features like the shotcrete or the EDZ. The teams were able to reproduce the measured parameters temperature, relative humidity and pore pressure. The modelled results for temperature agree very closely between the teams especially in the sensors in Opalinus Clay. All teams were able to reproduce the redistribution of water in the bentonite backfill due to heating. The evolution of the relative humidity showed similar trends with differences in the intensity of the dry out effect. To model the pore pressure evolution is more complex because it comprises the full interaction of the coupled THM processes. The spread between the pore pressure modelled by the teams was larger, with some teams overestimating the pressure increase due to heating and some teams overestimating the extent of drainage. The agreement of modelled results with measurements improves with larger distance to the heater. We conclude that the EDZ and the shotcrete potentially influence the behaviour of the rock causing higher differences closer to the heater. Further research is needed to better implement those influences into the models. Based on the calibrated models, the future evolution of temperature, relative humidity and pore pressure was predicted over the next 10 years following a change of the heat power applied in 2023 and 2024. Again, the predicted temperatures agree very closely between the teams. Most teams do not expect an increase in relative humidity during the next 10 years after the initial dry-out.

58 GEOSCIENCES↗