Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Swift heavy ion irradiation-induced amorphization of La2Ti2O7

Polycrystalline La2Ti2O7 powders have been irradiated with 2.0 GeV 181Ta ions up to a fluence of 1 × 1013 ions/cm2. Radiation-induced structural modifications were analyzed using synchrotron-based X-ray diffraction (XRD), small angle X-ray scattering (SAXS), Raman spectroscopy and transmission electron microscopy (TEM). An increase in the amorphous fraction as a function of fluence was revealed by XRD and Raman analyses and is evidenced by the reduction in intensity of the sharp Bragg maxima from the crystalline regions. Concurrently, diffraction maxima and vibrational absorption bands broaden with the increasing amorphous fraction. The cross-section for the crystalline-to-amorphous transformation (ion tracks) was determined by quantitative analysis of XRD patterns yielding a track diameter of d = 7.2 ± 0.9 nm. Slightly larger track diameters were obtained directly from TEM images (d = 10.6 ± 0.8 nm) and SAXS analysis (d = 10.6 ± 0.3 nm). High-resolution TEM images revealed that single tracks are entirely amorphous without any outer crystalline, disordered shell as found in pyrochlore oxides of the same stoichiometry. The large ratio of ionic radii of the A- and B-site cations (rA/rB = 1.94) means that disordering over the A- and B-sites is energetically unfavorable.

36 MATERIALS SCIENCE↗

A Mössbauer spectral study of degradation in La 0.58 Sr 0.4 Fe 0.5 Co 0.5 O 3–x after long-term operation in solid oxide electrolysis cells

Here, degradation processes of oxygen electrodes in solid oxide electrolysis cells (SOECs) were studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Mössbauer spectroscopy. La 0.58 Sr 0.4 Fe 0.5 Co 0.5 O 3–x (LSCF) anodes (oxygen electrode) were analyzed after different long-term operations durations of 1774, 6100 and 9000 h. The results were compared with a cell in the initial state. Besides the LSCF anode, the SOECs were composed of a Ce 0.8 Gd 0.2 O 1.9 barrier layer between the anode and electrolyte, yttria-stabilized zirconia (YSZ) as electrolyte and Ni-YSZ as cathode (hydrogen electrode). Mössbauer spectra of the iron-containing anode were acquired in order to determine the alteration of the iron oxidation state and its local environment during operation. Mössbauer spectroscopy yields indirect information about the degradation mechanism, especially in combination with SEM, TEM, and XRD. XRD and TEM revealed the appearance of Co 3 O 4 during the SOEC operation and SEM analyses confirmed the formation of SrZrO 3 at the electrode/electrolyte interface. The spectral analysis confirmed the reduction of iron from Fe(IV) to Fe(III) in LSCF after long-term operation. The fraction of Fe(IV) in the electrode decreased with time and 18, 15, 13 and 11% were obtained for 0, 1774, 6100, and 9000 h of operation, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards bend-contour-free dislocation imaging via diffraction contrast STEM

Dislocation imaging using transmission electron microscopy (TEM) has been an invaluable tool for characterizing crystallographic defects in metals. Compared to conventional TEM imaging, diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) with appropriate setting can provide better defect contrast with almost negligible bend contour artifacts, enabling more effective analysis of dislocation structures. Here, we investigated why STEM can suppresses bend contour, and how dislocation contrast behaves along with different STEM imaging parameters. Using a body-centered cubic HT-9 ferritic/martensitic alloy as an example, a simple procedure and operational theory are described at the beginning to help set up DCI STEM experiments. Comparing with conventional TEM and the STEM strictly complying with the principle of reciprocity, we found that a pair of STEM convergence and collection semi-angles, α S and β S , a few milliradians in size is essential for bend-contour-free defect imaging. It works in concert such that the convergence STEM probe opens up the reciprocal space, and then a comparable collection region evens out the rocking-curve oscillation and alleviates bend contours from the reciprocal space. This fundamental advantage is unique in DCI STEM. Practical guidelines regarding STEM parameters and specimen orientation and thickness are then provided for DCI STEM dislocation imaging. Lastly, we show that coupling DCI STEM with spectrum images of electron energy loss spectroscopy and of energy-dispersive X-ray Spectroscopy offers a comprehensive characterization of crystallographic defects and chemical information of complex microstructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward high-throughput defect density quantification: A comparison of techniques for irradiated samples

Transmission electron microscopy (TEM) is an established tool used for the investigation of defects in materials. Traditionally, diffraction contrast techniques—two-beam bright-field and weak-beam dark-field—have been used to image defects due to contrast sensitivity from weak lattice strains. Use of these methods entail an intricate tilt series of imaging using different diffracting vectors, g, to verify the g•b invisibility criterion relative to the different defect types and habit planes inherent to the material. Recently, the addition of down-zone imaging and STEM imaging has also proven to be effective imaging techniques for defect density analysis. Interest in nanocrystalline (NC) materials, spurred by their conjectured superior properties compared to their coarse-grain counterparts, has been thriving and the investigation of their defect morphologies is essential. Maneuvering within NC samples in the TEM adds another layer of difficulty making the aforementioned techniques not practical for application to specimens with complex microstructures. For this reason, we have devised a protocol for identifying NC grains optimally oriented for quantitative analysis using NanoMegas ASTAR automated crystal orientation mapping (ACOM) in the TEM. In this work, we conduct a series of experiments assessing the effectiveness of conventional two-beam bright-field, weak-beam dark-field, and down-zone STEM imaging. Here, we also evaluate an ACOM-assisted multibeam imaging method and compare defect density results obtained using each technique in an irradiated nanocrystalline Au sample.

36 MATERIALS SCIENCE↗

Experimental evidence of colloids and nanoparticles presence from 25 waste leachates

Highlights: • This work is the first assessment of colloids in waste leachates. • Analytical methods are proposed and discussed. • All the waste have at least one element in colloidal form, and some elements are always colloidal. • Man-made nanoparticles are observed. • It can change the interpretation of leachate elemental concentration. - Abstract: The potential colloids release from a large panel of 25 solid industrial and municipal waste leachates, contaminated soil, contaminated sediments and landfill leachates was studied. Standardized leaching, cascade filtrations and measurement of element concentrations in the microfiltrate (MF) and ultrafiltrate (UF) fraction were used to easily detect colloids potentially released by waste. Precautions against CO{sub 2} capture by alkaline leachates, or bacterial re-growth in leachates from wastes containing organic matter should be taken. Most of the colloidal particles were visible by transmission electron microscopy with energy dispersion spectrometry (TEM–EDS) if their elemental MF concentration is greater than 200 μg l{sup −1}. If the samples are dried during the preparation for microscopy, neoformation of particles can occur from the soluble part of the element. Size distribution analysis measured by photon correlation spectroscopy (PCS) were frequently unvalid, particularly due to polydispersity and/or too low concentrations in the leachates. A low sensitivity device is required, and further improvement is desirable in that field. For some waste leachates, particles had a zeta potential strong enough to remain in suspension. Mn, As, Co, Pb, Sn, Zn had always a colloidal form (MF concentration/UF concentration > 1.5) and total organic carbon (TOC), Fe, P, Ba, Cr, Cu, Ni are partly colloidal for more than half of the samples). Nearly all the micro-pollutants (As, Ba, Co, Cr, Cu, Mo, Ni, Pb, Sb, Sn, V and Zn) were found at least once in colloidal form greater than 100 μg l{sup −1}. In particular, the colloidal forms of Zn were always by far more concentrated than its dissolved form. The TEM–EDS method showed various particles, including manufactured nanoparticles (organic polymer, TiO{sub 2}, particles with Sr, La, Ce, Nd). All the waste had at least one element detected as colloidal. The solid waste leachates contained significant amount of colloids different in elemental composition from natural ones. The majority of the elements were in colloidal form for wastes of packaging (3), a steel slag, a sludge from hydrometallurgy, composts (2), a dredged sediment (#18), an As contaminated soil and two active landfill leachates. These results showed that cascade filtration and ICP elemental analysis seems valid methods in this field, and that electronic microscopy with elemental detection allows to identify particles. Particles can be formed from dissolved elements during TEM sample preparation and cross-checking with MF and UF composition by ICP is useful. The colloidal fraction of leachate of waste seems to be a significant source term, and should be taken into account in studies of emission and transfer of contaminants in the environment. Standardized cross-filtration method could be amended for the presence of colloids in waste leachates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Turbulent impurity transport simulations in Wendelstein 7-X plasmas

A study of turbulent impurity transport by means of quasilinear and nonlinear gyrokinetic simulations is presented for Wendelstein 7-X (W7-X). The calculations have been carried out with the recently developed gyrokinetic code stella. Different impurity species are considered in the presence of various types of background instabilities: ion temperature gradient (ITG), trapped electron mode (TEM) and electron temperature gradient (ETG) modes for the quasilinear part of the work; ITG and TEM for the nonlinear results. While the quasilinear approach allows one to draw qualitative conclusions about the sign or relative importance of the various contributions to the flux, the nonlinear simulations quantitatively determine the size of the turbulent flux and check the extent to which the quasilinear conclusions hold. Although the bulk of the nonlinear simulations are performed at trace impurity concentration, nonlinear simulations are also carried out at realistic effective charge values, in order to know to what degree the conclusions based on the simulations performed for trace impurities can be extrapolated to realistic impurity concentrations. The presented results conclude that the turbulent radial impurity transport in W7-X is mainly dominated by ordinary diffusion, which is close to that measured during the recent W7-X experimental campaigns. Finally, it is also confirmed that thermodiffusion adds a weak inward flux contribution and that, in the absence of impurity temperature and density gradients, ITG- and TEM-driven turbulence push the impurities inwards and outwards, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Dislocation Characterization by Electron Channeling Contrast Imaging and Cross-Correlation Electron Backscattered Diffraction

The characterization and quantification of dislocations is predominately carried out using transmission electron microscopy (TEM). Nevertheless, the sample preparation necessary for TEM foils can be cumbersome and possibly introduce defects. Two other techniques for characterizing and quantifying dislocations are electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD). ECCI is similar to TEM in that specific imaging (channeling or diffraction) conditions need to be established, but is carried out in a scanning electron microscope on bulk samples, resulting in less complex sample preparation. CC-EBSD measures subtle changes in orientation measured from EBSD patterns to calculate elastic strains and the Nye tensor to deduce and map the total geometrically necessary dislocation (GND) content. Furthermore, this work presented here compares the capabilities of ECCI and CC-EBSD to map dislocations generated from nanoindentation.

42 ENGINEERING↗

Ion Beam Induced Artifacts in Lead-Based Chalcogenides

Abstract Metal chalcogenides have attracted great attention because of their broad applications. It has been well acknowledged that microstructure can alter the intrinsic properties and performance of metal chalcogenides. The structure–property–performance relationships can be investigated at atomic scale with scanning transmission and transmission electron microscopy (STEM and TEM). Nevertheless, careful specimen preparation is paramount for accurate analyses and interpretations. In this work, we compare the effects of a variety of well-established TEM specimen preparation methods on the observed microstructure of an ingot stoichiometric lead telluride (PbTe). Most importantly, from aberration corrected STEM and first principles calculations, we discovered that argon (Ar) ion milling can lead to surface irradiation damage in the form of Pb vacancy clusters and self-interstitial atom (SIA) clusters. The SIA clusters appear as orthogonal nanoscale features when characterized along the <001> crystal orientation of the rock salt structured PbTe. This obfuscates the interpretation of the intrinsic microstructure of metal chalcogenides, especially lead chalcogenides. We demonstrate that with sufficiently low energy (300 eV) Ar ion cleaning or appropriate high-temperature annealing, the surface damage layer can be properly cleaned and the orthogonal nanoscale features are significantly reduced. This reveals the materials’ intrinsic structure and can be used as the standard protocol for future TEM specimen preparation of lead-based chalcogenide materials.

Materials Science↗

Atomic Resolution Imaging of Light Elements in a Crystalline Environment using Dynamic Hollow-Cone Illumination Transmission Electron Microscopy

Multiple electron scattering and the nonintuitive nature of image formation with coherent radiation complicate the interpretation of conventional transmission electron microscopy images. Precession of the illuminating beam in transmission electron microscopy (TEM) can lead to more robust and interpretable images with some penalty to image contrast, a technique known as dynamic hollow-cone illumination TEM. Here, we demonstrate direct and robust imaging of light and heavy atoms in a crystalline environment with this technique. This method is similar to the annular bright-field technique in scanning transmission electron microscopy, via the principle of reciprocity. Dynamic hollow-cone illumination TEM is challenging in practice due to sensitivity to the misalignment of the precession axis, microscope objective aperture, and crystal zone axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Machine Learning of In-situ Temperature Reconstruction from Metal-nanoparticle Thermometry on Transmission Electron Microscopy

Utilizing Python programming language and third-party libraries, 2D temperature fields were reconstructed from TEM images demonstratively and a GUI was created. Local temperatures can be fast read on TEM at the nanoscale based on the nanoparticle thermometry. The Artificial Intelligence technique would speed up the in-situ heating TEM research and make real-time in-situ temperature monitoring possible at nanoscale.

42 ENGINEERING↗

Scanning Electrochemical and Photoelectrochemical Microscopy on Finder Grids: Toward Correlative Multitechnique Imaging of Surfaces

Scanning electrochemical microscopy (SECM) is a powerful technique for mapping surface reactivity and investigating heterogeneous processes on the nanoscale. Despite significant advances in high-resolution SECM and photo-SECM imaging, they cannot provide atomic scale structural information about surfaces. By correlating the SECM images with atomic scale structural and bonding information obtained by transmission electron microscopy (TEM) techniques with one-to-one correspondence, one can elucidate the nature of the active sites and understand the origins of heterogeneous surface reactivity. Here, to enable multitechnique imaging of the same nanoscale portion of the electrode surface, we develop a methodology for using a TEM finder grid as a conductive support in SECM and photo-SECM experiments. In this paper, we present the results of our first nanoscale SECM and photo-SECM experiments on carbon TEM grids, including imaging of semiconductor nanorods.

14 SOLAR ENERGY↗

Self-Healing Thermal Annealing: Surface Morphological Restructuring Control of GaN Nanorods

With advances in nanolithography and dry etching, top-down methods of nanostructuring have become a widely used tool for improving the efficiency of optoelectronics. These nano dimensions can offer various benefits to the device performance in terms of light extraction and efficiency, but often at the expense of emission color quality. Broadening of the target emission peak and unwanted yellow luminescence are characteristic defect-related effects due to the ion beam etching damage, particularly for III–N based materials. In this article we focus on GaN based nanorods, showing that through thermal annealing the surface roughness and deformities of the crystal structure can be “self-healed”. Correlative electron microscopy and atomic force microscopy show the change from spherical nanorods to faceted hexagonal structures, revealing the temperature-dependent surface morphology faceting evolution. The faceted nanorods were shown to be strain- and defect-free by cathodoluminescence hyperspectral imaging, micro-Raman, and transmission electron microscopy (TEM). In-situ TEM thermal annealing experiments allowed for real time observation of dislocation movements and surface restructuring observed in ex-situ annealing TEM sampling. This thermal annealing investigation gives new insight into the redistribution path of GaN material and dislocation movement post growth, allowing for improved understanding and in turn advances in optoelectronic device processing of compound semiconductors.

36 MATERIALS SCIENCE↗

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

Role of Ammonium Hydroxide on Glucose Oxidase Immobilized in Metal–Azolate Framework-7 Enzyme Activity

Enzymes are nature’s catalysts, but their instability outside native environments limits practical applications. Metal–organic frameworks (MOFs) offer a promising platform for enzyme immobilization, enhancing stability, and reusability through their tunable porosity and crystallinity. While ZIF-based MOFs have been extensively studied, metal azolate framework-7 (MAF-7) remains largely unexplored for biomimetic mineralization. Its hydrophilic character makes it a promising alternative for enzyme encapsulation; however, the role of essential basic modulators such as ammonium hydroxide (NH 4 OH) on enzyme structure and function has not been investigated. Here, in this study, we examine the NH 4 OH mediated synthesis of glucose oxidase within MAF-7 using powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), cryogenic transmission electron microscopy (cryo-TEM), and enzyme assays. Our results show that NH 4 OH modulates crystal morphology, enzyme activity, and nucleation behavior, with higher concentrations leading to partial enzyme denaturation and reduced catalytic performance. By integrating time-resolved cryo-TEM with activity assays, we uncover how modulator concentration impacts early stage crystallization and enzyme folding, a mechanistic insight not previously demonstrated in MOF systems. These findings highlight modulator chemistry as a critical, underexplored variable in MOF synthesis, advancing rational design strategies for enzyme@MOFs (E@MOF) beyond ZIFs and toward more tunable, biocompatible frameworks like MAF-7.

36 MATERIALS SCIENCE↗

Measurement of the Dewetting, Nucleation, and Deactivation Kinetics of Carbon Nanotube Population Growth by Environmental Transmission Electron Microscopy

Understanding the collective growth of carbon nanotube (CNT) populations is key to tailoring their properties for many applications. During the initial stages of CNT growth by chemical vapor deposition, catalyst nanoparticle formation by thin-film dewetting and the subsequent CNT nucleation processes dictate the CNT diameter distribution, areal density, and alignment. Here, in this study, we use in situ environmental transmission electron microscopy (E-TEM) to observe the catalyst annealing, growth, and deactivation stages for a population of CNTs grown from a thin-film catalyst. Complementary in situ electron diffraction and TEM imaging show that, during the annealing step in hydrogen, reduction of the iron oxide catalyst is concomitant with changes in the thin-film morphology; complete dewetting and the formation of a population of nanoparticles is only achieved upon the introduction of the carbon source, acetylene. The dewetting kinetics, i.e., the appearance of distinct nanoparticles, exhibits a sigmoidal (autocatalytic) curve with 95% of all nanoparticles appearing within 6 s. After nanoparticles form, they either nucleate CNTs or remain inactive, with incubation times measured to be as small as 3.5 s. Via E-TEM we also directly observe the crowding and self-alignment of CNTs after dewetting and nucleation. In addition, in situ electron energy loss spectroscopy reveals that the collective rate of carbon accumulation decays exponentially. We conclude that the kinetics of catalyst formation and CNT nucleation must both be addressed in order to achieve uniform and high CNT density, and their transient behavior may be a primary cause of the well-known nonuniform density of CNT forests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tailoring the Physicochemical Properties of Nb Thin Films via Surface Engineering Methods

The modification of surface oxide layers formed on niobium (Nb) thin films via chemical mechanical planarization (CMP) and accelerated neutral atom beam (ANAB) processing provides a promising route toward tailoring their emergent properties and performance when used as superconducting qubits. Here, in this study, we show that CMP- and ANAB-formed Nb oxides are significantly thinner and smoother than the native oxide, as revealed by transmission electron microscopy (TEM) and atomic force microscopy. Scanning TEM and energy-dispersive X-ray spectroscopy along with X-ray photoelectron spectroscopy identified an oxidation gradient within the native and surface-engineered oxides. The topside layer is dominated by Nb 5+ (Nb 2 O 5 ), with various Nb suboxides present closer to the oxide/metal interface. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling confirmed the presence of an oxygen content gradient and demonstrated the enhanced resistance of the CMP- and ANAB-formed oxides to oxygen surface exchange and subsequent diffusion via 18 O 2 isotopic labeling experiments. ToF-SIMS also identified an interfacial layer containing trapped hydrogen (H)-containing species at the Nb oxide/metal interface. In situ ToF-SIMS and TEM revealed migration of the H/OH interfacial layer coinciding with decomposition of the surface oxide. Furthermore, our density functional theory calculations indicated that both H from moisture present in ambient air and bulk H in Nb films tend to segregate at the interface. These findings underscore the importance of understanding surface oxidation mechanisms, hydrogen incorporation, and their impact on the designed functionalities of Nb-based devices.

36 MATERIALS SCIENCE↗

Investigation of Thermal Stability of P2–Na x CoO 2 Cathode Materials for Sodium Ion Batteries Using Real-Time Electron Microscopy

In this paper, we take advantage of in situ transmission electron microscopy (TEM) to investigate the thermal stability of P2-type Na x CoO 2 cathode materials for sodium ion batteries, which are promising candidates for next-generation lithium ion batteries. A double-tilt TEM heating holder was used to directly characterize the changes in the morphology and the crystallographic and electronic structures of the materials with increase in temperature. The electron diffraction patterns and the electron energy loss spectra demonstrated the presence of cobalt oxides (Co 3 O 4 , CoO) and even metallic cobalt (Co) at higher temperatures as a result of reduction of Co ions and loss of oxygen. The bright-field TEM images revealed that the surface of Na x CoO 2 becomes porous at high temperatures. Higher cutoff voltages result in degrading thermal stability of Na x CoO 2 . Finally, the observations herein provide a valuable insight that thermal stability is one of the important factors to be considered in addition to the electrochemical properties when developing new electrode materials for novel battery systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Structural and Chemical Evolution of an Inverse CeO x /Cu Catalyst under CO 2 Hydrogenation: Tunning Oxide Morphology to Improve Activity and Selectivity

Small nanoparticles of ceria deposited on a powder of CuO display a very high selectivity for the production of methanol via CO 2 hydrogenation. CeO 2 /CuO catalysts with ceria loadings of 5%, 20%, and 50% were investigated. Among these, the system with 5% CeO x showed the best catalytic performance at temperatures between 200 and 350 °C. The evolution of this system under reaction conditions was studied using a combination of environmental transmission electron microscopy (E-TEM), in situ X-ray absorption spectroscopy (XAS), and time-resolved X-ray diffraction (TR-XRD). For 5% CeO x /Cu, the in situ studies pointed to a full conversion of CuO into metallic copper, with a complete transformation of Ce 4+ into Ce 3+ . Images from E-TEM showed drastic changes in the morphology of the catalyst when it was exposed to H 2 , CO 2 , and CO 2 /H 2 mixtures. Under a CO 2 /H 2 feed, there was a redispersion of the ceria particles that was detected by E-TEM and in situ TR-XRD. Finally, these morphological changes were made possible by the inverse oxide/metal configuration and facilitate the binding and selective conversion of CO 2 to methanol.

03 NATURAL GAS↗