Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Station”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Analysis of Fast Charging Station Network for Electrified Ride-Hailing Services

Today's electric vehicle (EV) owners charge their vehicles mostly at home and seldom use public direct current fast charger (DCFCs), reducing the need for a large deployment of DCFCs for private EV owners. However, due to the emerging interest among transportation network companies to operate EVs in their fleet, there is great potential for DCFCs to be highly utilized and become economically feasible in the future. This paper describes a heuristic algorithm to emulate operation of EVs within a hypothetical transportation network company fleet using a large global positioning system data set from Columbus, Ohio. DCFC requirements supporting operation of EVs are estimated using the Electric Vehicle Infrastructure Projection tool. Operation and installation costs were estimated using real-world data to assess the economic feasibility of the recommended fast charging stations. Results suggest that the hypothetical transportation network company fleet increases daily vehicle miles traveled per EV with less overall down time, resulting in increased demand for DCFC. Sites with overhead service lines are recommended for hosting DCFC stations to minimize the need for trenching underground service lines. A negative relationship was found between cost per unit of energy and fast charging utilization, underscoring the importance of prioritizing utilization over installation costs when siting DCFC stations. Although this preliminary analysis of the impacts of new mobility paradigms on alternative fueling infrastructure requirements has produced several key results, the complexity of the problem warrants further investigation.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal Balance of a Manned Space Station

In order for any analysis to yield reasonable results when applied to a realistic configuration, it must account for convective, conductive, and radiative heat transfer through and within the vehicle, and, unless the vehicle surface is wholly convex, for the complex interchange of radiation between external surfaces. The following is a comprehensive view of the entire heat balance problem, including internal and external radiation, conduction, and internal convection heat transfer. In addition, a specific method of temperature control, particularly suited to manned space stations is suggested. The method makes use of the "atmosphere" within the space station as a major factor in the process of heat distribution. The vehicle air is circulated between the living quarters and an area containing the bulk of the heat generating equipment. By regulating the flow rate, temperature changes in the living quarters are minimized at the expense of increased fluctuation of the equipment are temperature. This technique has been applied to a manned orbital space station (MOSS) configuration, suggested by NASA's Langley Research Center. The feasibility of this approach has been demonstrated in terms of required and available flow rates, and the range of allowable equipment temperatures.

Environmental control↗

Shielding requirements for manned orbiting space stations

A detailed parametric investigation of radiation shielding requirements was performed for first generation manned orbiting space stations. Two specific space station designs were studied; the results of the shielding analysis are based on the actual geometry of the vehicles, onboard equipment, and supplies. Results are presented for circular orbits ranging from 100 to 600 nautical miles and from 29° to 90° inclination. The effects of the geometry of the space stations, the use of personal shielding, and the use of particular shielding materials are discussed.

MANNED ORBITAL SPACE STATION /MOSS/↗

International Space Station Lithium-Ion Battery Start-Up

International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.

Lithium-Ion↗

Reflections on 20 Years of Research on the International Space Station

November 2, 2000 began an era of continuous human presence on the International Space Station (ISS). That first crewed expedition to the ISS had few scientific instruments and facilities to work with, yet managed to conduct 52research investigations. Today, crew oversee upwards of 300 investigations during their time aboard. Indeed, over the past 20 years the ISS has evolved into a robust laboratory with dozens of research facilities, capabilities for the autonomous monitoring and conduct of research, and a growing array of scientific tools available and observational instruments active. As a result, the station has hosted more than 3,000 research investigations generating more than 2,400 scientific publications across every major discipline of science. The ISS Program Science Forum is composed of senior science representatives across the station’s international partnership. It provides multilateral science leadership to the ISS Program. Indeed, ISS research has evolved to become a truly international activity encompassing the participation of more than 4,000 investigators from over 100 countries whose research has been completed or is ongoing. This paper provides an overview of the research and technology development conducted to date and reflects upon the accomplishments, impacts and future direction of ISS research from the perspective of the member organizations of the Program Science Forum. Research areas which have been a focus of ISS research to date and key implications both for future space exploration and scientific advancement are presented. Major Earth benefits derived from ISS research are discussed. Finally, the paper provides insight into areas of emphasis for future research including the maturation of technological capabilities needed for deep space exploration, including lunar exploration programs such as Artemis and future missions to Mars

International Space Station↗

Mitigating the Impact of Momentum Unloads on Station-Keeping Around Libration Point Orbits

Station-keeping maneuvers are required to maintain a spacecraft close to a Libration point orbit, where the size of these maneuvers depends on different perturbations and any unmodeled forces. In many missions, despite being small, frequent momentum unloads can have a large impact on the size of station-keeping maneuvers. In this paper we will show that applying momentum unloads in the Linear Approximation of the Non-Escape (LANE) direction can significantly reduce their impact on the station-keeping delta-v budget.

Libration Point Orbits↗

Advancements in Remote Ground Control Station Operator Pilot in Command Training Program for Beyond Visual Line of Sight Flight Operations

The training program for a Remote Ground Control Station Operator Pilot in Command (R-GCSO PIC) at NASA Langley Research Center marks a pivotal evolution in preparing operators for Beyond Visual Line of Sight (BVLOS) operations. This program, developed within the Advanced Air Mobility (AAM) project High Density Vertiplex (HDV) subproject, was crafted to bridge the gap between traditional Ground Control Station Operators (GCSO) and R-GCSO PICs, focusing on uncrewed aircraft systems (UAS). It encompassed extensive theoretical and practical training, including hands-on experience with advanced simulators and live flight operations, while ensuring a deep understanding of BVLOS complexities. The training leveraged NASA technologies like the MPATH (Measuring Performance for Autonomy Teaming with Humans) ground control station software and incorporated human factors principles to enhance operational readiness. This paper details the program's development, execution, and the critical insights gained, emphasizing the necessity of continuous adaptation in training methodologies to meet the evolving demands of UAS operations in the National Airspace System.

Ground control station operator↗

H2USA: Siting Refueling Stations in the Northeast

To achieve cost-effective deployment of both fuel cell electric vehicles (FCEVs) and hydrogen stations, the number of vehicles and public stations must grow together in areas of highest demand. This fact sheet introduces two advanced modeling tools and presents preliminary analysis of the hydrogen refueling station locations needed to support early consumer demand for FCEVs in the Northeast United States. United States.

33 ADVANCED PROPULSION SYSTEMS↗

Embedding Equity into Electric Vehicle Charging Station Design

Once a site location is selected for the installation of an electric vehicle (EV) charging station, the next step is to plan and design the specific station. Local and state governments can require and/ or incentivize accessible and safe design elements, so the station is constructed in an equitable manner.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Techno-Economic Assessments of Second-Life Batteries for Electric Vehicle Charging Stations

When electric vehicle (EV) batteries degrade below a certain capacity, they may no longer be suitable for automotive use but can be repurposed as second-life batteries (SLBs) for other applications, such as EV charging stations. When integrated with photovoltaic (PV) systems, SLB can store surplus solar energy, reducing reliance on the grid and lowering operational costs. This paper presents a novel techno-economic assessment framework for deploying SLBs in combination with PV in grid-connected EV charging stations. The proposed framework integrates the value proposition, charging station operation, optimal dispatch strategies, battery degradation modeling, input data requirements, and detailed procedures for generating key economic performance metrics. Insightful analyses are performed to assess the performance of SLBs in comparison to new batteries across various cost scenarios. The results indicate that SLBs become financially attractive when their cost is 40% or lower than new batteries.

energy storage↗

AmeriFlux US-DUF Denver Urban Field Station

This is the AmeriFlux version of the carbon flux data for the site US-DUF Denver Urban Field Station. Site Description - This site was established on a 25m freestanding former radio tower at the Forest Service's Rocky Mountain Research Station headquarters in Fort Collins, CO. The tower is situated next to a parking lot and several one and two story buildings. To the north and west is the campus of Colorado State University, and to the north and east is low density residential development. To the south and east are a busy intersection and rapid transit bus line, and to the south is green space surrounding the City of Fort Collins' Spring Creek Trail.

Frank, John [US Forest Service, Rocky Mountain Res↗

Precipitation and Air Pollution at Mountain and Plain Stations in Northern China: Insights Gained from Observations and Modeling

We analyzed 40 year data sets of daily average visibility (a proxy for surface aerosol concentration) and hourly precipitation at seven weather stations, including three stations located on the Taihang Mountains, during the summertime in northern China. There was no significant trend in summertime total precipitation at almost all stations. However, light rain decreased, whereas heavy rain increased as visibility decreased over the period studied. The decrease in light rain was seen in both orographic-forced shallow clouds and mesoscale stratiform clouds. The consistent trends in observed changes in visibility, precipitation, and orographic factor appear to be a testimony to the effects of aerosols. The potential impact of large-scale environmental factors, such as precipitable water, convective available potential energy, and vertical wind shear, on precipitation was investigated. No direct links were found. To validate our observational hypothesis about aerosol effects, Weather Research and Forecasting model simulations with spectral-bin microphysics at the cloud-resolving scale were conducted. Model results confirmed the role of aerosol indirect effects in reducing the light rain amount and frequency in the mountainous area for both orographic-forced shallow clouds and mesoscale stratiform clouds and in eliciting a different response in the neighboring plains. The opposite response of light rain to the increase in pollution when there is no terrain included in the model suggests that orography is likely a significant factor contributing to the opposite trends in light rain seen in mountainous and plain areas.

air pollution↗

Influence of lure choice and survey duration on scent stations for carnivore surveys

Abstract Noninvasive, camera‐based, scent station surveys have become a common approach to estimate population parameters for mammalian carnivores. Many carnivores are particularly sensitive to olfactory cues; and, as such, the quality and quantity of odor attractant used during surveys can significantly affect the accuracy and precision of the survey. Additionally, survey length is also an important consideration because many mammalian predators are highly mobile and elusive in nature. Using scent station surveys in autumn 2013 and 2014 on the Savannah River Site, Aiken, South Carolina, USA, we tested the effects of 5 lures: fatty acid, fish oil, synthetic fermented egg, beaver castor, and skunk essence on visitation rates, visitation probability, and latency to visitation of multiple predator species. We also estimated occupancy probability for 2 carnivore species using different survey lengths to determine the effect of survey period on the precision of occupancy estimates. We found that skunk essence had greater visitation probability and visits than other lures evaluated. Species‐specific bait‐preference models revealed that raccoons ( Procyon lotor ) were more likely to visit skunk essence, and coyotes ( Canis latrans ) were less likely to visit fish oil as compared with fatty acid. Latency to visitation ranged from 104.7 to 112.1 hours and did not vary among scents. Longer survey durations resulted in more precise estimates of occupancy and detection probability. Our results suggest a wide range of scents commonly used for carnivore capture may perform as well as, or better than, fatty acid for noninvasive carnivore surveys. Further, study designs should carefully consider the duration of scent‐station surveys depending on the level of precision desired in estimates of occupancy and detection probability. © 2019 The Wildlife Society.

Webster, Sarah C.↗

Methane Exhaust Measurements at Gathering Compressor Stations in the United States

Unburned methane entrained in exhaust from natural gas-fired compressor engines (“combustion slip”) can account for a substantial portion of station-level methane emissions. A novel in-stack, tracer gas method was coupled with Fourier transform infrared (FTIR) species measurements to quantify combustion slip from natural gas compressor engines at 67 gathering and boosting stations owned or managed by nine “study partner” operators in 11 U.S. states. The mean methane emission rate from 63 four-stroke, lean-burn (4SLB) compressor engines was 5.62 kg/h (95% CI = 5.15–6.17 kg/h) and ranged from 0.3 to 12.6 kg/h. The mean methane emission rate from 39 fourstroke, rich-burn (4SRB) compressor engines was 0.40 kg/h (95% CI = 0.37– 0.42 kg/h) and ranged from 0.01 to 4.5 kg/h. Study results for 4SLB engines were lower than both the U.S. EPA compilation of air pollutant emission factors (AP-42) and Inventory of U.S. Greenhouse Gas Emissions and Sinks (GHGI) by 8 and 9%, respectively. Study results for 4SRB engines were 43% of the AP-42 emission factor and 8% of the GHGI emission factor, the latter of which does not distinguish between engine types. Total annual combustion slip from the U.S. natural gas gathering and boosting sector was modeled using measured emission rates and compressor unit counts from the U.S. EPA Greenhouse Gas Reporting Program. Modeled results [328 Gg/y (95% CI = 235–436 Gg/y) of unburned methane] would account for 24% (95% CI = 17–31%) of the 1391 Gg of methane emissions for “Gathering and Boosting Stations”, or 6% of the net emissions for “Natural Gas Systems” (5598 Gg) as reported in the 2020 U.S. EPA GHGI. In conclusion, gathering and boosting combustion slip emissions reported in the 2020 GHGI (374 Gg) fall within the uncertainty of this model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of ash cenospheres in fly ash from Australian power stations

Ash cenospheres in fly ashes from five Australian power stations have been characterized. The experimental data show that ash cenosphere yield varies across the power stations. Ash partitioning occurred in the process of ash cenosphere formation during combustion. Contradictory to conclusions from the literature, iron does not seem to be essential to ash cenosphere formation in the cases examined in the present work. Further investigation was also undertaken on a series of size-fractioned ash cenosphere samples from Tarong power station. It is found that about 70 wt% of ash cenospheres in the bulk sample have sizes between 45 and 150 {mu}m. There are two different ash cenosphere structures, that is, single-ring structure and network structure. The percentage of ash cenospheres of a network structure increases with increasing ash cenosphere size. Small ash cenospheres (in the size fractions {lt}150 {mu}m) have a high SiO{sub 2}/Al{sub 2}O{sub 3} ratio, and the majority of the ash cenospheres are spherical and of a single-ring structure. Large ash cenosphere particles (in the size fractions of 150-250 {mu}m and {gt}250 {mu}m) have a low SiO{sub 2}/Al{sub 2}O{sub 3} ratio, and a high proportion of the ash cenospheres are nonspherical and of a network structure. A novel quantitative technique has been developed to measure the diameter and wall thickness of ash cenospheres on a particle-to-particle basis. A monolayer of size-fractioned ash cenospheres was dispersed on a pellet, which was then polished carefully before being examined using a scanning electron microscope and image analysis. The ash cenosphere wall thickness broadly increases with increasing ash cenosphere size. The ratios between wall thickness and diameter of ash cenospheres are limited between an upper bound of about 10.5% and a lower bound of about 2.5%, irrespective of the ash cenosphere size. 52 refs., 9 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗