A Verification Framework for Runtime Assurance of Autonomous UAS

Runtime Assurance (RTA) is a design-time architecture for safety-critical systems where an internal monitor acts upon detecting a violation of a property. The simplex architecture is an instance of RTA, where the action taken is to hand control of the overall system to a trusted controller when an untrusted one violates a safety property. Simplex RTA is emerging as a method for allowing AI/ML and other unverified software to be integrated into safety-critical applications like aircraft. To this end, the American Society for Testing and Materials (ASTM) and NASA have each published guidelines on the use of RTA in such systems. In the simplex RTA framework, a system has an advanced controller (AC) and a reversionary controller (RC). The system is allowed to operate with the AC until a runtime monitor detects that some property has been violated and then the RC takes over. Assuming that the sample rate of the monitor will detect improper functioning with enough time for the RC to correct the impending problem, and that the RC is trusted, the system will operate as intended. This use of the simplex RTA framework can allow for the integration of untrusted, but possibly more performant, controllers in a safe way. This paper presents a formalization of a simplex RTA framework in the Prototype Verification System (PVS) theorem prover using an embedding of differential dynamic logic (DDL) called Plaidypvs. A novel feature of this framework is that it can be instantiated at different levels of abstraction. This feature allows for the formal verification of a system with an untrusted black box component, such as an AI/ML controller. This paper does not address the many difficulties in deploying RTA in an industrial-level system. Instead, the focus is on the formal verification of the simplex RTA framework in the language of hybrid programs. Hybrid programs are programs that include both discrete and continuous dynamics and can be used to model complex cyber-physical systems. Plaidypvs is a tool that enables formalization of hybrid programs in the PVS theorem prover. Plaidypvs enables the verification of the general simplex RTA framework and then, by specializing some components of the hybrid program, verifying instances of the framework while treating the untrusted component as a black box. A selection of Unmanned Aircraft Systems (UAS) operations are shown as instances of the general RTA framework in PVS. This offers the benefit of design time verification of relevant safety properties to the system, and it also gives requirements on the sample rate of sensors that determine the time interval in which the ‘switch’ property of the RTA framework is checked.

PVS↗

Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife Perfexion{sup TM}

Purpose: The purpose of this study was to evaluate the dosimetric characteristics of each sector of the Leksell Gamma Knife Perfexion (LGK PFX) and to develop tests that can be done for the routine quality assurance checks of the sectors of the LGK PFX. Methods: The following tests were performed to evaluate the dosimetric characteristics of the sectors: (1) Flash-radiation dose for the 16 mm collimator, (2) transit-radiation dose for the 8 and 4 mm collimators, (3) sector leakage within the radiation cavity and, (4) sector output uniformity. In these tests, the Elekta ABS phantom was used. A micropoint ion-chamber Exradin A16 was placed at the center of the phantom for all measurements. Results: With the version 8.0 of the control software of the MCU in the LGK PFX, the average flash-radiation dose per sector for the 16 mm collimator was measured to be 0.423 {+-} 0.003 cGy, and the average transit-radiation dose per sector for the 8 and 4 mm collimators was measured to be 0.169 {+-} 0.0009 and 0.147 {+-} 0.020 cGy, respectively. The calibration dose rate on the day of measurements was 280.8 cGy/min. Here, the authors have introduced a new concept of ''equivalent-time-duration'' (ETD) to represent the time duration, during which the flash-radiation or the transit-radiation dose is delivered. The ETD is a quotient of the measured dose of the flash-radiation or the transit-radiation and the respective calibrated dose rate for the 16, 8, or 4 mm collimator. The ETD constancy is an indicator of the constancy of the sector movements. The average value of ETD per sector was measured to be 724 {+-} 6, 313 {+-} 2, and 311 {+-} 45 ms for the 16, 8, and 4 mm collimators, respectively. During monthly spot checks, the authors have been measuring the total ETD for the flash-radiation when all eight sectors are open with the 16 mm collimator. The average value of the total ETD of the last 40 consecutive months was measured to be 642 {+-} 10 ms. This number is a useful quality parameter for the LGK PFX, which can be used to establish the base-line performance of the collimators of the LGK PFX. The reader is alerted that with the newly introduced version 9.0 of the control software of the MCU in the LGK PFX, the flash-radiation and the transit-radiation doses have become practically zero due to the fact that the treatment time is now corrected to compensate for these radiation doses. The sector output uniformity for the 16, 8, and 4 mm collimators was determined to be 98.9%, 97.3%, and 96.6%, respectively. The total leakage radiation with in the radiation cavity from all sectors was measured to be 0.17% of the dose output for the 16 mm collimator. Conclusions: Our measurements show that the dosimetric characteristics of all sectors of the LGK PFX are satisfactory. The authors recommend that the sector performance of the LGK PFX be determined initially at the time of installation of the LGK PFX and thereafter, at least annually. Similarly, our recommendation is that the total flash-radiation dose for the 16 mm collimator and the corresponding ETD value be measured on a monthly basis. Should any change in the sector movement occur, it will be revealed by the sector performance and the measurement of ETD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-TeP3-11: Radiobiological-Cum-Dosimetric Quality Assurance of Complex Radiotherapy Plans

Purpose: Dosimetric gamma-analysis used for QA of complex radiotherapy plans tests the dosimetric equivalence of a delivered plan with the treatment planning system (TPS) optimized plan. It does not examine whether a dosimetric difference results in any radiobiological difference. This study introduces a method to test the radiobiological and dosimetric equivalence between a delivered and the TPS optimized plan. Methods: Six head and neck and seven lung cancer VMAT or IMRT plans optimized for patient treatment were calculated and delivered to an ArcCheck phantom. ArcCheck measured dose distributions were compared with the TPS calculated dose distributions using a 2-D gamma-analysis. Dose volume histograms (DVHs) for various patient structures were obtained by using measured data in 3DVH software and compared against the TPS calculated DVHs using 3-D gamma analysis. DVH data were used in the Poisson model to calculate tumor control probability (TCP) for the treatment targets and in the sigmoid dose response model to calculate normal tissue complication probability (NTCP) for the normal structures. Results: Two-D and three-D gamma passing rates among six H&N patient plans differed by 0 to 2.7% and among seven lung plans by 0.1 to 4.5%. Average ± SD TCPs based on measurement and TPS were 0.665±0.018 and 0.674±0.044 for H&N, and 0.791±0.027 and 0.733±0.031 for lung plans, respectively. Differences in NTCPs were usually negligible. The differences in dosimetric results, TCPs and NTCPs were insignificant. Conclusion: The 2-D and 3-D gamma-analysis based agreement between measured and planned dose distributions may indicate their dosimetric equivalence. Small and insignificant differences in TCPs and NTCPs based on measured and planned dose distributions indicate the radiobiological equivalence between the measured and optimized plans. However, patient plans showing larger differences between 2-D and 3-D gamma-analysis can help us make a more definite conclusion through our ongoing research with a larger number of patients.

60 APPLIED LIFE SCIENCES↗

IC Workflow Project (Final Report)

The Workflow Project is a joint research task between the CASL Advanced Modeling Applications (AMA) and the Virtual Reactor Integration (VRI) focus areas, and the Industry Council. The purpose of the project is to solicit the expertise of the IC member organizations to inform CASL staff and provide feedback for the development of CASL products. The goal is for CASL staff to understand existing workflows at end-user organizations in order to achieve compatibility of CASL products with current needs and future plans. CASL is committed to developing and delivering advanced capabilities and solutions that will allow the nuclear power industry to solve complex problems and improve the operating performance and efficiency of light water reactors. Through the R&D being performed by CASL, advanced computational methods and software is being developed and embodied in the Virtual Environment for Reactor Applications (VERA). The information collected through this project will provide additional considerations that must be included in the development of VERA to ensure that it meets the needs of the nuclear industry. As will be discussed below, key additional areas that must be considered is the usability of the system in an engineering environment including the user input, quality assurance, output of results, computational runtime, and integration into existing engineering analysis processes. This document contains a summary of information gathered through a series of interviews and meetings with IC organizations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid Analysis, Self-Calibrating Array for Air Monitoring

Human space missions have critical needs for monitoring and control for life support systems. These systems have monitoring needs that include feedback for closed loop processes and quality control for environmental factors. Sensors and monitoring technologies assure that the air environment and water supply for the astronaut crew habitat fall within acceptable limits, and that the life support system is functioning properly and efficiently. The longer the flight duration and the more distant the destination, the more critical it becomes to have carefully monitored and automated control systems for life support. Past experiments with the JPL ENose have demonstrated a lifetime of the sensor array, with the software, of around 18 months. The lifetime of the calibration, for some analytes, was as long as 24 months. We are working on a sensor array and new algorithms that will include sensor response time in the analysis. The preliminary array analysis for two analytes shows that the analysis time, of an event, can be dropped from 45 minutes to less than10 minutes and array training time can be cut substantially. We will describe the lifetime testing of an array and show lifetime data on individual sensors. This progress will lead to more rapid identification of analytes, and faster training time of the array.

Self Calibrating↗

TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

07 ISOTOPE AND RADIATION SOURCES↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-02: A Novel, Highly Efficient and Automated Quality Assurance Tool for Modern Linear Accelerators

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. Varian’s Machine Performance Check (MPC) uses IsoCal phantom to test geometric and dosimetric aspects of the TrueBeam systems in <5min. In this study we independently tested the accuracy and robustness of the MPC tools. Methods: MPC is automated for simultaneous image-acquisition, using kV-and-MV onboard-imagers (EPIDs), while delivering kV-and-MV beams in a set routine of varying gantry, collimator and couch angles. MPC software-tools analyze the images to test: i) beam-output and uniformity, ii) positional accuracy of isocenter, EPIDs, collimating jaws (CJs), MLC leaves and couch and iii) rotational accuracy of gantry, collimator and couch. 6MV-beam dose-output and uniformity were tested using ionization-chamber (IC) and ICarray. Winston-Lutz-Tests (WLT) were performed to measure isocenter-offsets caused by gantry, collimator and couch rotations. Positional accuracy of EPIDs was evaluated using radio-opaque markers of the IsoCal phantom. Furthermore, to test the robustness of the MPC tools we purposefully miscalibrated a non-clinical TrueBeam by introducing errors in beam-output, energy, symmetry, gantry angle, couch translations, CJs and MLC leaves positions. Results: 6MV-output and uniformity were within ±0.6% for most measurements with a maximum deviation of ±1.0%. Average isocenter-offset caused by gantry and collimator rotations was 0.316±0.011mm agreeing with IsoLock (0.274mm) and WLT (0.41mm). Average rotation-induced couch-shift from MPC was 0.378±0.032mm agreeing with WLT (0.35mm). MV-and-kV imager-offsets measured by MPC were within ±0.15mm. MPC predicted all machine miscalibrations within acceptable clinical tolerance. MPC detected the output miscalibrations within ±0.61% while the MLC and couch positions were within ±0.06mm and ±0.14mm, respectively. Gantry angle miscalibrations were detected within ±0.1°. Conclusions: MPC is a useful tool for QA of TrueBeam systems and its automation makes it highly efficient for testing both geometric and dosimetric aspects of the machine. This is very important for hypo-fractionated SBRT treatments. Received support from Varian Medical Systems, Palo Alto, CA 94304-1038.

07 ISOTOPE AND RADIATION SOURCES↗

A Real-Time Position-Locating Algorithm for CCD-Based Sunspot Tracking

NASA Marshall Space Flight Center's (MSFC) EXperimental Vector Magnetograph (EXVM) polarimeter measures the sun's vector magnetic field. These measurements are taken to improve understanding of the sun's magnetic field in the hopes to better predict solar flares. Part of the procedure for the EXVM requires image motion stabilization over a period of a few minutes. A high speed tracker can be used to reduce image motion produced by wind loading on the EXVM, fluctuations in the atmosphere and other vibrations. The tracker consists of two elements, an image motion detector and a control system. The image motion detector determines the image movement from one frame to the next and sends an error signal to the control system. For the ground based application to reduce image motion due to atmospheric fluctuations requires an error determination at the rate of at least 100 hz. It would be desirable to have an error determination rate of 1 kHz to assure that higher rate image motion is reduced and to increase the control system stability. Two algorithms are presented that are typically used for tracking. These algorithms are examined for their applicability for tracking sunspots, specifically their accuracy if only one column and one row of CCD pixels are used. To examine the accuracy of this method two techniques are used. One involves moving a sunspot image a known distance with computer software, then applying the particular algorithm to see how accurately it determines this movement. The second technique involves using a rate table to control the object motion, then applying the algorithms to see how accurately each determines the actual motion. Results from these two techniques are presented.

Taylor, Jaime R.↗

Overarching Properties as Means of Compliance: An Industrial Case Study

The Overarching Properties (OPs) have been created by an inter-national working group and are being evaluated by the National Aeronautics and Space Administration (NASA), the Federal Aviation Administration (FAA), industry, and other certifying agencies in an effort to streamline certification processes. Their intent is to facilitate the use of alternative approaches and to al-low flexibility to combine the system, software, and complex hardware certification. The hope is that the FAA may eventually establish an Advisory Circular that offers the OPs as a Means of Compliance (MoC) for software approval (and eventually systems and hardware) by showing the product possesses the three OPs: Intent (specification of the intended behavior), Correctness (implementation of the intended behavior) and Innocuity (safety of unintended behavior). In the certification community, there is still a concern about the practicability of using such high level properties in certification. This paper aims to address that concern by showing possession of the OPs in an industrial case study using assurance arguments. The two main contributions of this paper are: a certification process based on OPs as Means of Compliance, and a certification argument for an on-board physical model of an UAV, as industrial example. We pro-pose a hybrid approach for the certification process that combines OPs with existing certification standards. Thus, OPs can be used for parts of a system that uses technologies that are not supported by current standards or for which existing standards require additional effort without commensurate additional safety assurance.

certification↗

Recent Improvement Of The Institutional Radioactive Waste Management System In Slovenia

The task of managing institutional radioactive waste was assigned to the Slovenian National Agency for Radwaste Management by the Governmental Decree of May 1999. This task ranges from the collection of waste at users' premises to the storage in the Central Storage Facility in (CSF) and afterwards to the planned Low and Intermediate Level Waste (LILW) repository. By this Decree ARAO also became the operator of the CSF. The CSF has been in operation since 1986. Recent improvements of the institutional radioactive waste management system in Slovenia are presented in this paper. ARAO has been working on the reestablishment of institutional radioactive waste management since 1999. The Agency has managed to prepare the most important documents and carry out the basic activities required by the legislation to assure a safe and environmentally acceptable management of the institutional radioactive waste. With the aim to achieve a better organized operational system, ARAO took the advantage of the European Union Transition Facility (EU TF) financing support and applied for the project named 'Improvement of the management of institutional radioactive waste in Slovenia via the design and implementation of an Information Business System'. Through a public invitation for tenders one of the Slovenian largest software company gained the contract. Two international radwaste experts from Belgium were part of their project team. The optimization of the operational system has been carried out in 2007. The project was executed in ten months and it was divided into two phases. The first phase of the project was related with the detection of weaknesses and implementation of the necessary improvements in the current ARAO operational system. With the evaluation of the existing system, possible improvements were identified. In the second phase of the project the software system Information Business System (IBS) was developed and implemented by the group of IT experts. As a software development life-cycle methodology the Waterfall methodology was used. The reason for choosing this methodology lied in its simple approach: analyze the problem, design the solution, implement the code, test the code, integrate and deploy. ARAO's institutional radioactive waste management process was improved in the way that it is more efficient, better organized, allowing traceability and availability of all documents and operational procedures within the field of institutional radioactive waste. The tailored made IBS system links all activities of the institutional radioactive waste management process: collection, transportation, takeover, acceptance, storing, treatment, radiation protection, etc. into one management system. All existing and newly designed evidences, operational procedures and other documents can be searched and viewed via secured Internet access from different locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Formal Assurance Certifiable Tooling Formal Assurance Certifiable Tooling Strategy Final Report

This is the Final Report of a research project to investigate issues and provide guidance for the qualification of formal methods tools under the DO-330 qualification process. It consisted of three major subtasks spread over two years: 1) an assessment of theoretical soundness issues that may affect qualification for three categories of formal methods tools, 2) a case study simulating the DO-330 qualification of two actual tool sets, and 3) an investigation of risk mitigation strategies that might be applied to chains of such formal methods tools in order to increase confidence in their certification of airborne software.

Bush, Eric↗

The SDSS data archive server

The Sloan Digital Sky Survey (SDSS) Data Archive Server (DAS) provides public access to data files produced by the SDSS data reduction pipeline. This article discusses challenges in public distribution of data of this volume and complexity, and how the project addressed them. The Sloan Digital Sky Survey (SDSS)1 is an astronomical survey of covering roughly one quarter of the night sky. It contains images of this area, a catalog of almost 300 million objects detected in those images, and spectra of more than a million of these objects. The catalog of objects includes a variety of data on each object. These data include not only basic information but also fit parameters for a variety of models, classifications by sophisticated object classification algorithms, statistical parameters, and more. If the survey contains the spectrum of an object, the catalog includes a variety of other parameters derived from its spectrum. Data processing and catalog generation, described more completely in the SDSS Early Data Release2 paper, consists of several stages: collection of imaging data, processing of imaging data, selection of spectroscopic targets from catalogs generated from the imaging data, collection of spectroscopic data, processing of spectroscopic data, and loading of processed data into a database. Each of these stages is itself a complex process. For example, the software that processes the imaging data determines and removes some instrumental signatures in the raw images to create 'corrected frames', models the point spread function, models and removes the sky background, detects objects, measures object positions, measures the radial profile and other morphological parameters for each object, measures the brightness of each object using a variety of methods, classifies the objects, calibrates the brightness measurements against survey standards, and produces a variety of quality assurance plots and diagnostic tables. The complexity of the spectroscopic data reduction pipeline is similar. Each pipeline deposits the results in a collection of files on disk. The Catalog Archive Server (CAS) provides an interface to a database of objects detected through the SDSS along with their properties and observational metadata. This serves the needs of most users, but some users require access to files produced by the pipelines. Some data, including the corrected frames (the pixel data itself corrected for instrumental signatures), the models for the point spread function, and an assortment of quality assurance plots, are not included in the database at all. Sometimes it is simply more convenient for a user to read data from existing files than to retrieve it using database queries. This is often the case, for example, when a user wants to download data a significant fraction of objects in the database. Users might need to perform analysis that requires more computing power than the CAS database servers can reasonably provide, and so need to download the data so that it can be analyzed with local resources. Users can derive observational parameters not measured by the standard SDSS pipeline from the corrected frames, metadata, and other data products, or simply use the output of tools with which they're familiar. The challenge in distributing these data is lies not in the distribution method itself, but in providing tools and support that allow users to find the data they need and interpret it properly. After introducing the data itself, this article describes how the DAS uses ubiquitous and well understood technologies to manage and distribute the data. It then discusses how it addresses the more difficult problem of helping the public find and use the data it contains, despite its complexity of its content and organization.

99 GENERAL AND MISCELLANEOUS↗

Licklider Transmission Protocol Implementation

This software is an implementation of the Licklider Transmission Protocol (LTP), a communications protocol intended to support the Bundle Protocol in Delay-Tolerant Network (DTN) operations. LTP is designed to provide retransmission-based reliability over links characterized by extremely long message round-trip times and/or frequent interruptions in connectivity. Communication in interplanetary space is the most prominent example of this sort of environment, and LTP is principally aimed at supporting long-haul reliable transmission over deep-space RF links. Like any reliable transport service employing ARQ (Automatic Repeat re-Quests), LTP is stateful. In order to assure the reception of a block of data it has sent, LTP must retain for possible retransmission all portions of that block which might not have been received yet. In order to do so, it must keep track of which portions of the block are known to have been received so far, and which are not, together with any additional information needed for purposes of retransmitting part, or all, of the block. Long round-trip times mean substantial delay between the transmission of a block of data and the reception of an acknowledgement from the block s destination, signaling arrival of the block. If LTP postponed transmission of additional blocks of data until it received acknowledgement of the arrival of all prior blocks, valuable opportunities to use what little deep space transmission bandwidth is available would be forever lost. For this reason, LTP is based in part on a notion of massive state retention. Any number of requested transmission conversations (sessions) may be concurrently in flight at various displacements along the link between two LTP engines, and the LTP engines must necessarily retain transmission status and retransmission resources for all of them. Moreover, if any of the data of a given block are lost en route, it will be necessary to retain the state of that transmission during an additional round trip while the lost data are retransmitted; even multiple retransmission cycles may be necessary. LTP's possible multiplicity of sessions per association makes it necessary for each segment of application data to include an additional demultiplexing token: a session ID that uniquely identifies the session in which the segment was issued and, implicitly, the block of data being conveyed by this session. This software comprises a prototype implementation developed by Johns Hopkins University APL in cooperation with JPL, together with adaptations that improve the robustness, correctness, and operability of that implementation.

Burleigh, Scott C.↗

Genesis Solar Wind – Capture, Return, Curate and Analyze: Looking Backward and Creating a Timeline

Introduction: In 1997 NASA’S Discovery Program selected the Genesis mission proposal to return solar wind samples to Earth for laboratory analyses. Principal Investigator Donald S. Burnett and the science team defined the purity of collector materials and ability to analyze solar wind composition to the precision required for planetary science. As a small mission, focused on a well-defined science goal, yet needing careful attention to engineering details, the communication among scientists and engineers, nurtured by Don Burnett, was exceptional. Genesis Mission and Curation Legacy: Genesis, as the first U. S. spacecraft to return astromaterial samples since Apollo, not only integrated the mission planning and flight teams, but also the science and sample curation teams during the mission development period. Since Genesis is a sample return mission, the Science Team was essential in certifying the collectors (sample containers for solar atoms). From inception, Genesis established mission funding for returned sample curation. JSC was lead in contamination control during mission preparation, including establishment of an ISO 4 cleanroom facility and use of ultrapure water (UPW) for cleaning flight hardware (and, as it turned out, for cleaning collectors after the mishap). Reliable, fast communication among scientists, engineers and curators at the hands-on level established deep respect among team members and efficient decision-making. JSC’s 50-years of astromaterial sample curation provided experienced sample processors onsite during recovery in Utah (a deep bench for emergency response). Post-recovery curation included iterative collaboration with science sample users to clean or verify cleanliness of samples. The science legacy from Genesis is addressed by Burnett and Jurewicz, this volume. In The Beginning: After Apollo sample return, Burnett and Marcia Neugebauer at JPL began discussing a solar wind sample return, with Neugebauer arguing that separate collection of solar wind regimes was essential science. By 1992 a solar wind sample return mission was presented at a workshop, and by 1994 a mission was proposed named Suess-Urey. The mission was re-proposed under a new name GENESIS and selected in 1997. Susan Niebur captured the Genesis mission history and stories, from high level management documents and from many interviews with participants [2]. Her account lets readers glimpse personality of participants in quotations from interviews. Need and Scope for Detailed Technical Timeline: A timeline constructed from lower level task documents has been initiated to document the resources and skills actually used, as well as task sequence or concurrency. Timelines for high level mission events are captured in two documents [1] [2] and for detailed re-entry events in [3]. A detailed technical timeline for Genesis mission and curation activities will provide data points for lower level tasks, such as ISO 4 curation facility construction time, preparation for nominal sample field recovery, mishap recovery, and UPW expansion. Changes in technology context 1990-2024: Semiconductor technologies were easily accessible in the U.S.A. (1990-1999), and the Genesis team used those resources for cleanroom design and UPW system expansion. Image documentation was changing from film to digital during cleanroom construction and payload cleaning (1997-2001). Engineering design was done using computer aided design proprietary software, making more difficult the archiving of payload configuration and materials. Email of documents, tracked delivery service and virtual meeting capability greatly improved communication efficiency. Information sources – Pre-launch mission preparation: Examples of mission science, engineering and contamination control are collector purity testing, payload design/fabrication and ISO 4 cleanroom construction. Information on timing of these activities comes from facility readiness reviews, management reviews, shipping documents, procurement documents, test reports, travel documents, laboratory logs, Quality Assurance documents, dates on images, participant notebooks and emails. Information sources – Sample return re-entry and field recovery activities: Information comes from event timelines produced by Mid-Air Recovery team, Lockheed team lead notes and from chase video, JPL Quality Assurance. Information also comes from images and logbooks from UTTR cleanroom operations and from curatorial documents. Information sources – Resulting science and sample cleaning processes: Agendas from the annual gatherings of the science team initially trace testing for collector purity/cleanliness, and after sample recovery, include collector cleaning and cleanliness assessment. Post-recovery documents include curatorial orders and procedures, sample allocation documents and LPSC abstracts. Timeline Objectives: A simple spreadsheet timeline with headers DATE, EVENT, PEOPLE, COMMENT, INFORMATION SOURCE has been initiated and currently has over 90 entries. While this is not definitive historical research, it is a quick look at the evolution of Genesis curation with pointers to documents or people with information. Engineers for future missions may find useful points of comparison for development of facilities. References:[1] Genesis Mission Reference Document, (2011) JPL D-62382.[2] Niebur S. M., edited by Brown D. W. (2023) NASA’s Discovery Program: The First 20 Years of Competitive Planetary Exploration, NASA-SP-2023-4238.[3] Genesis Mishap Investigation Board Report, Vol. 1 (July 2005).

solar wind↗

Applied Operations Research: Operator's Assistant

NASA operates high value critical equipment (HVCE) that requires trouble shooting, periodic maintenance and continued monitoring by Operations staff. The complexity HVCE and information required to maintain and trouble shoot HVCE to assure continued mission success as paper is voluminous. Training on new HVCE is commensurate with the need for equipment maintenance. LaRC Research Directorate has undertaken a proactive research to support Operations staff by initiation of the development and prototyping an electronic computer based portable maintenance aid (Operator's Assistant). This research established a goal with multiple objectives and a working prototype was developed. The research identified affordable solutions; constraints; demonstrated use of commercial off the shelf software; use of the US Coast Guard maintenance solution; NASA Procedure Representation Language; and the identification of computer system strategies; where these demonstrations and capabilities support the Operator, and maintenance. The results revealed validation against measures of effectiveness and overall proved a substantial training and capability sustainment tool. The research indicated that the OA could be deployed operationally at the LaRC Compressor Station with an expectation of satisfactorily results and to obtain additional lessons learned prior to deployment at other LaRC Research Directorate Facilities. The research revealed projected cost and time savings.

Cole, Stuart K.↗

Results of a Multi-Institutional Benchmark Test for Cranial CT/MR Image Registration

Purpose: Variability in computed tomography/magnetic resonance imaging (CT/MR) cranial image registration was assessed using a benchmark case developed by the Quality Assurance Review Center to credential institutions for participation in Children's Oncology Group Protocol ACNS0221 for treatment of pediatric low-grade glioma. Methods and Materials: Two DICOM image sets, an MR and a CT of the same patient, were provided to each institution. A small target in the posterior occipital lobe was readily visible on two slices of the MR scan and not visible on the CT scan. Each institution registered the two scans using whatever software system and method it ordinarily uses for such a case. The target volume was then contoured on the two MR slices, and the coordinates of the center of the corresponding target in the CT coordinate system were reported. The average of all submissions was used to determine the true center of the target. Results: Results are reported from 51 submissions representing 45 institutions and 11 software systems. The average error in the position of the center of the target was 1.8 mm (1 standard deviation = 2.2 mm). The least variation in position was in the lateral direction. Manual registration gave significantly better results than did automatic registration (p = 0.02). Conclusion: When MR and CT scans of the head are registered with currently available software, there is inherent uncertainty of approximately 2 mm (1 standard deviation), which should be considered when defining planning target volumes and PRVs for organs at risk on registered image sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extending Aquatic Spectral Information with the First Radiometric IR-B Field Observations

Planetary radiometric observations enable remote sensing of biogeochemical parameters to describe spatiotemporal variability in aquatic ecosystems. For approximately the last half century, the science of aquatic radiometry has established a knowledge base using primarily, but not exclusively, visible wavelengths. Scientific subdisciplines supporting aquatic radiometry have evolved hardware, software, and procedures to maximize competency for exploiting visible wavelength information. This perspective culminates with the science requirement that visible spectral resolution must be continually increased to extract more information. Other sources of information, meanwhile, remain underexploited, particularly information from nonvisible wavelengths. Herein, absolute radiometry is used to evaluate spectral limits for deriving and exploiting aquatic data products, specifically the normalized water-leaving radiance, Γ(λ)⁠, and its derivative products. Radiometric observations presented herein are quality assured for individual wavebands, and spectral verification is conducted by analyzing celestial radiometric results, comparing agreement of above- and in-water observations at applicable wavelengths, and evaluating consistency with bio-optical models and optical theory. The results presented include the first absolute radiometric field observations of Γ(λ) within the IR-B spectral domain (i.e. spanning 1400–3000 nm), which indicate that IR-B signals confer greater and more variable flux than formerly ascribed. Black-pixel processing, a routine correction in satellite and in situ aquatic radiometry wherein a spectrum is offset corrected relative to a nonvisible waveband (often IR-B or a shorter legacy waveband) set to a null value, is shown to degrade aquatic spectra and derived biogeochemical parameters.

aquatic optics↗