Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Wireless Frequency‐Multiplexed Acoustic Array‐Based Acoustofluidics

Abstract Acoustofluidics has shown great potential in enabling on‐chip technologies for driving liquid flows and manipulating particles and cells for engineering, chemical, and biomedical applications. To introduce on‐demand liquid sample processing and micro/nano‐object manipulation functions to wearable and embeddable electronics, wireless acoustofluidic chips are highly desired. This paper presents wireless acoustofluidic chips to generate acoustic waves carrying sufficient energy and achieve key acoustofluidic functions, including arranging particles and cells, generating fluid streaming, and enriching in‐droplet particles. To enable these functions, the wireless acoustofluidic chips leverage mechanisms, including inductive coupling‐based wireless power transfer (WPT), frequency multiplexing‐based control of multiple acoustic waves, and the resultant acoustic radiation and drag forces. For validation, the wirelessly generated acoustic waves are measured using laser vibrometry when different materials (e.g., bone, tissue, and hand) are inserted between the WPT transmitter and receiver. Moreover, the wireless acoustofluidic chips successfully arrange nanoparticles into different patterns, align cells into parallel pearl chains, generate streaming, and enrich in‐droplet microparticles. This research is anticipated to facilitate the development of embeddable wireless on‐chip flow generators, wearable sensors with liquid sample processing functions, and implantable devices with flow generation and acoustic stimulation abilities for engineering, veterinary, and biomedical applications.

Li, Jiali↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Federated Learning for Efficient Condition Monitoring and Anomaly Detection in Industrial Cyber-Physical Systems

Detecting and localizing anomalies in cyber-physical systems (CPS) has become increasingly challenging as systems grow in complexity, particularly due to varying sensor reliability and node failures in distributed environments. While federated learning (FL) offers a foundation for distributed model training, existing approaches lack mechanisms to handle these CPS-specific challenges. This paper presents an enhanced FL framework that introduces three key innovations: adaptive model aggregation based on sensor reliability, dynamic node selection for resource optimization, and Weibull-based checkpointing for fault tolerance. Our framework enables reliable condition monitoring while addressing the computational and reliability challenges of industrial CPS deployments. Experiments on NASA Bearing and Hydraulic System Datasets demonstrate superior performance over state-of-the-art FL methods, achieving 99.5% AUC-ROC in anomaly detection and maintaining accuracy under node failures. Statistical validation using Mann-Whitney (U) test confirms significant improvements (p < 0.05) in both detection accuracy and computational efficiency across diverse operational scenarios.1

Marfo, William [University of Texas at El Paso,Dep↗

Wave Tank Testing Report for Controls Validation of a Heaving Point Absorber

The core objectives of this project is to improve the power capture of three different wave energy conversion (WEC) devices by more than 50% using an advanced control system and validate the attained improvements using wave tank and full scale testing. In parallel, we will bring along the development of a wave prediction system that is required to enable effective control and test it at full scale. The purposes of this report are to: 1. Plan and document the 1/25th scale device testing at the wave-tank facility; 2. Document the test article, setup and methodology, sensor and instrumentation, mooring, electronics, wiring, and data flow and quality assurance; 3. Communicate the testing results between the associated members; 4. Facilitate reviews that will help to ensure all aspects (risk, safety, testing procedures, etc.); 5. Provide a systematic guide to setting up, executing and decommissioning the experiment.

16 TIDAL AND WAVE POWER↗

Remote Monitoring of the Structural Health of Hydrokinetic Composite Turbine Blades (Final Report)

A health monitoring approach is investigated for hydrokinetic turbine blade applications. In-service monitoring is critical due to the difficult environment for blade inspection and the cost of inspection downtime. Composite blade designs have advantages that include long life in marine environments and great control over mechanical properties. Experimental strain characteristics are determined for static loads and free-vibration loads. These experiments are designed to simulate the dynamic characteristics of hydrokinetic turbine blades. Carbon/epoxy symmetric composite laminates are manufactured using an autoclave process. Four-layer composite beams, eight-layer composite beams, and two-dimensional eight-layer composite blades are instrumented for strain. Experimental results for strain measurements from electrical resistance gages are validated with theoretical characteristics obtained from in-house finite-element analysis for all sample cases. These preliminary tests on the composite samples show good correlation between experimental and finite-element strain results. A health monitoring system is proposed in which damage to a composite structure, e.g. delamination and fiber breakage, causes changes in the strain signature behavior. The system is based on embedded strain sensors and embedded motes in which strain information is demodulated for wireless transmission. In-service monitoring is critical due to the difficult environment for blade inspection and the cost of inspection downtime. Composite blade designs provide a medium for embedding sensors into the blades for in-situ health monitoring. The major challenge with in-situ health monitoring is transmission of sensor signals from the remote rotating reference frame of the blade to the system monitoring station. In the presented work, a novel system for relaying in-situ blade health measurements in hydrokinetic systems is described and demonstrated. An ultrasonic communication system is used to transmit sensor data underwater from the rotating frame of the blade to a fixed relay station. Data are then broadcast via radio waves to a remote monitoring station. Results indicate that the assembled system can transmit simulated sensor data with an accuracy of ±5% at a maximum sampling rate of 500 samples/sec. A power investigation of the transmitter within the blade shows that continuous max-sampling operation is only possible for short durations (~days), and is limited due to the capacity of the battery power source. However, intermittent sampling, with long periods between samples, allows for the system to last for very long durations (~years). Finally, because the data transmission system can operate at a high sampling rate for short durations or at a lower sampling rate/higher duty cycle for long durations, it is well-suited for short-term prototype and environmental testing, as well as long-term commercially-deployed hydrokinetic machines.

13 HYDRO ENERGY↗

Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays

This is the final technical report for the Virginia Tech Center for Photonics Technology (VT-CPT) research project entitled “Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays”. In the the four-year effort, VT-CPT collaborated with the Departments of Mathmatics at VT and Sentek Instrument, LLC (Sentek) to develop a fiber-optic sensing system capable of real-time simultaneous distributed measurement of multiple subsurface, drilling, and production parameters. The ultra-sensitive fiber optic distributed acoustic sensing technology, picoDAS, developed by Sentek was integrated with a novel multi-material optical sensing fiber fabricated by CPT-VT to obtain distributed acoustic and magnetic field measurements with ultrahigh sensitivity and high spatial resolution. The sensing technology successfully developed and demonstrated under this research program is truly unique has application beyond subsurface imaging to include carbon storage and electrical grid monitoring, as well as healthcare and nuclear fusion. The project, sponsored by the Advanced Technology Program, began in 2019 and had the original goal of developing the next generation of harsh environment sensing systems. Exhaustive theoretical modeling was performed to optimize the multi-material optical fiber design. VT developed the processing techniques employed to successfully fabricate single mode fibers with metal cladding wires. Sensing fibers with nickel and Metglas cladding wires were fully characterized, inscribed with sensors, and fully integrated with the picoDAS system. Laboratory scale testing was performed to demonstrate performance upon exposure to lateral and transverse magnetic fields. Preliminary field trials were performed for prototype magnetic and acoustic sensing systems upon near surface deployment at VT. The distributed acoustic and magnetic field sensing system was advanced from a (Technology Readiness Level) TRL=2 to a TRL=5 via laboratory scale system validation in relevant environments. The truly one-of-its kind distributed magnetic and acoustic sensing system is expected to find immediate applications that require subsurface monitoring, to include carbon storage site monitoring, and has the potential to be a distributive technology in healthcare and electric grid markets. The technologies developed by Virginia Tech’s Center for Photonics Technology will support the mission of the National Energy Technology Laboratory (NETL) to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future by ensuring affordable, abundant, and reliable energy that drives a robust economy and national security. Technical accomplishments during the program are summarized briefly here and described in detail in the remainder of the report.

02 PETROLEUM↗

Reactor Power Level Estimation by Fusing Multi-Modal Sensor Measurements

Estimates of the power level of a nuclear reactor based on measurements from an independent monitoring sensor system can help in the compliance verification of its declared operations. We present a three-level fusion method to estimate the power level of a nuclear reactor using features derived from infrared, electromagnetic, and acoustic sensor measurements collected in proximity to the reactor. Based on a simplified analytical model of the secondary coolant system of the reactor, we identify partial regression functions of the power level in terms of the temperature difference between inlet and outlet of coolant pipes, and the activity levels of four fans and four pumps, which are estimated as features from the sensor measurements. The power level estimator employs a combination of aggregate and complementary fusion steps at three levels to incorporate the multi-modal features in a structure that reflects the secondary cooling system and its partial regression functions. Using the measurements from a test campaign at an operational reactor, we show that this estimator achieves 3.47% or lower root mean square error under 5-fold cross validation. More generally, these results illustrate a progressive reduction in estimation error as additional modalities are appropriately incorporated, and that the fuser outperforms single modality features and their sub-combinations.

Rao, Nageswara↗

A First Demonstration of the SQUAT Detector Architecture: Direct Measurement of Resonator-Free Charge-Sensitive Transmons

The Superconducting Quasiparticle-Amplifying Transmon (SQUAT) is a new sensor architecture for THz (meV) detection based on a weakly charge-sensitive transmon directly coupled to a transmission line. In such devices, energy depositions break Cooper pairs in the qubit capacitor islands, generating quasiparticles. Quasiparticles that tunnel across the Josephson junction change the transmon qubit parity, generating a measurable signal. In this paper, we present the design of first-generation SQUATs and demonstrate an architecture validation. We summarize initial characterization measurements made with prototype devices, comment on background sources that influence the observed parity-switching rate, and present experimental results showing simultaneous detection of charge and quasiparticle signals using aluminum-based SQUATs.

Magoon, H. [SLAC; KIPAC, Menlo Park; Stanford U., ↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

Validation of an inverse model of zone air heat balance

Our work introduces the validation method and results of an inverse model of zone air heat balance. The inverse model, implemented in EnergyPlus and published in a previous article [1], calculates highly uncertain model parameters such as internal thermal mass and infiltration airflow by inversely solving the zone air heat balance equation using the easy-to-measure zone air temperature data. The paper provides technical details of validation from the experiments using LBNL's Facility for Low Energy eXperiment in Buildings (FLEXLAB) that measures zone air temperature under the controlled experiment of two levels of internal mass and four levels of infiltration airflow. The simulation results of the zone infiltration airflow and internal thermal mass from the inverse model agree well with the measured data from the FLEXLAB experiments. The validated inverse model in EnergyPlus can be utilized to enhance the energy modeling of existing buildings that enables energy performance assessments for energy efficiency improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Implications of stop-and-go traffic on training learning-based car-following control

Learning-based car-following control (LCC) of connected and autonomous vehicles (CAVs) is gaining significant attention with the advancement of computing power and data accessibility. While the flexibility and large model capacity of model-free architecture enable LCC to potentially outperform the model-based car-following (CF) model in improving traffic efficiency and mitigating congestion, the generalizability of LCC for traffic conditions different from the training environment/dataset is not well-understood. Herein, this study seeks to explore the impact of stop-and-go traffic in the training dataset on the generalizability of LCC. It uses the characteristics of lead vehicle trajectories to describe stop-and-go traffic, and links the theory of identifiability (i.e., obtaining a unique parameter estimation result using sensor measurements) to the generalizability of behavior cloning (BC) and policy-based deep reinforcement learning (DRL). Correspondingly, the study shows theoretically that: (i) stop-and-go traffic can enable the property of identifiability and enhance the control performance of BC-based LCC in different traffic conditions; (ii) stop-and-go traffic is not necessary for DRL-based LCC to generalize to different traffic conditions; (iii) DRL-based LCC trained with only constant-speed lead vehicle trajectories (not sufficient to ensure identifiability) can be generalized to different traffic conditions; and (iv) stop-and-go traffic increases variance in the training dataset, which improves the convergence of parameter estimation while negatively impacting the convergence of DRL to the optimal control policy. Numerical experiments validate the above findings, illustrating that BC-based LCC entails comprehensive training datasets for generalizing to different traffic conditions, while DRL-based LCC can achieve generalization with simple free-flow traffic training environments. This further suggests DRL as a more promising and cost-effective LCC approach to reduce operational costs, mitigate traffic congestion, and enhance safety and mobility, which can accelerate the deployment and acceptance of CAVs.

33 ADVANCED PROPULSION SYSTEMS↗

Introducing “ The Integrator ”: A novel technique to monitor environmental flow systems

Abstract We introduce “ The Integrator ,” a novel technique to quantify transport and reaction metrics commonly used to characterize flow systems. This development consists of two products: (1) The Integrator sampling device and (2) its supporting mathematical framework, which is compatible with semi‐continuous sensor data. The use of The Integrator device simplifies the logistics of sample collection and greatly reduces the number of samples needed, making it ideal to characterize systems that are: (1) difficult to access, (2) large and thus intractable or highly heterogeneous, and (3) highly instrumented otherwise but where a more holistic, mechanistic understanding may be gained by monitoring one or more currently untracked elements. We tested and validated The Integrator technique using experimental data collected from a heart rate monitor (high‐quality, high‐frequency data in response to known excitation events) and solute tracer experiments conducted in two contrasting (fourth and seventh order) rivers. In the Supporting Information , we provide details concerning the design of The Integrator device used in our field case studies and provide insight into potential improvements. Despite our case studies focus on the analysis of conservative and reactive transport of solutes in rivers, the principles behind The Integrator technique can be used to monitor water quality in hyporheic zones, aquifers, wetlands, swamps, karsts, oceans, wastewater treatment plants, pipe networks, and air quality. Furthermore, special arrangements of Integrator devices can be used to gather data at spatial and temporal resolutions that are currently unattainable due to high transportation and/or personnel costs.

54 ENVIRONMENTAL SCIENCES↗

Insights from application of a hierarchical spatio-temporal model to an intensive urban black carbon monitoring dataset

Existing regulatory pollutant monitoring networks rely on a small number of centrally located measurement sites that are purposefully sited away from major emission sources. While informative of general air quality trends regionally, these networks often do not fully capture the local variability of air pollution exposure within a community. Recent technological advancements have reduced the cost of sensors, allowing air quality monitoring campaigns with high spatial resolution. The 100×100 black carbon (BC) monitoring network deployed 100 low-cost BC sensors across the 15 km 2 West Oakland, CA community for 100 days in the summer of 2017, producing a nearly continuous site-specific time series of BC concentrations which we aggregated to one-hour averages. Leveraging this dataset, we employed a hierarchical spatio-temporal model to accurately predict local spatio-temporal concentration patterns throughout West Oakland, at locations without monitors (average cross-validated hourly temporal R 2 =0.60). Using our model, we identified spatially varying temporal pollution patterns associated with small-scale geographic features and proximity to local sources. In a sub-sampling analysis, here we demonstrated that fine scale predictions of nearly comparable accuracy can be obtained with our modeling approach by using ~30% of the 100×100 BC network supplemented by a shorter-term high-density campaign.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS)

The use of small unmanned aircraft systems (sUAS) with miniature sensor systems for atmospheric research is an important capability to develop. The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) project, lead by Dr. Gijs de Boer of the Cooperative Institute for Research in Environmental Sciences (CIRES- a partnership of NOAA and CU-Boulder), is a significant milestone in realizing this new potential. This project has clearly demonstrated that the concept of sUAS utilization is valid, and miniature instrumentation can be used to further our understanding of the atmospheric boundary layer in the arctic.

54 ENVIRONMENTAL SCIENCES↗

An Algorithm to Retrieve Total Precipitable Water Vapor in the Atmosphere from FengYun 3D Medium Resolution Spectral Imager 2 (FY-3D MERSI-2) Data

The atmosphere has substantial effects on optical remote sensing imagery of the Earth&rsquo;s surface from space. These effects come through the functioning of atmospheric particles on the radiometric transfer from the Earth&rsquo;s surface through the atmosphere to the sensor in space. Precipitable water vapor (PWV), CO 2 , ozone, and aerosol in the atmosphere are very important among the particles through their functioning. This study presented an algorithm to retrieve total PWV from the Chinese second-generation polar-orbiting meteorological satellite FengYun 3D Medium Resolution Spectral Imager 2 (FY-3D MERSI-2) data, which have three near-infrared (NIR) water vapor absorbing channels, i.e., channel 16, 17, and 18. The algorithm was improved from the radiance ratio technique initially developed for Moderate-Resolution Imaging Spectroradiometer (MODIS) data. MODTRAN 5 was used to simulate the process of radiant transfer from the ground surfaces to the sensor at various atmospheric conditions for estimation of the coefficients of ratio technique, which was achieved through statistical regression analysis between the simulated radiance and transmittance values for FY-3D MERSI-2 NIR channels. The algorithm was then constructed as a linear combination of the three-water vapor absorbing channels of FY-3D MERSI-2. Measurements from two ground-based reference datasets were used to validate the algorithm: the sun photometer measurements of Aerosol Robotic Network (AERONET) and the microwave radiometer measurements of Energy&rsquo;s Atmospheric Radiation Measurement Program (ARMP). The validation results showed that the algorithm performs very well when compared with the ground-based reference datasets. The estimated PWV values come with root mean square error (RMSE) of 0.28 g/cm 2 for the ARMP and 0.26 g/cm 2 for the AERONET datasets, with bias of 0.072 g/cm 2 and 0.096 g/cm 2 for the two reference datasets, respectively. The accuracy of the proposed algorithm revealed a better consistency with ground-based reference datasets. Thus, the proposed algorithm could be used as an alternative to retrieve PWV from FY-3D MERSI-2 data for various remote sensing applications such as agricultural monitoring, climate change, hydrologic cycle, and so on at various regional and global scales.

54 ENVIRONMENTAL SCIENCES↗

THE MASS OF HD 38529c FROM HUBBLE SPACE TELESCOPE ASTROMETRY AND HIGH-PRECISION RADIAL VELOCITIES

Hubble Space Telescope Fine Guidance Sensor astrometric observations of the G4 IV star HD 38529 are combined with the results of the analysis of extensive ground-based radial velocity (RV) data to determine the mass of the outermost of two previously known companions. Our new RVs obtained with the Hobby-Eberly Telescope and velocities from the Carnegie-California group now span over 11 yr. With these data we obtain improved RV orbital elements for both the inner companion, HD 38529b, and the outer companion, HD 38529c. We identify a rotational period of HD 38529 (P {sub rot} = 31.65 {+-} 0fd17) with Fine Guidance Sensor photometry. The inferred star spot fraction is consistent with the remaining scatter in velocities being caused by spot-related stellar activity. We then model the combined astrometric and RV measurements to obtain the parallax, proper motion, perturbation period, perturbation inclination, and perturbation size due to HD 38529c. For HD 38529c we find P = 2136.1 {+-} 0.3 d, perturbation semimajor axis {alpha} = 1.05 {+-} 0.06 mas, and inclination i = 48.{sup 0}3 {+-} 3.{sup 0}7. Assuming a primary mass M {sub *} = 1.48 M {sub sun}, we obtain a companion mass M{sub c} = 17.6{sup +1.5} {sub -1.2} M {sub Jup}, 3{sigma} above a 13 M {sub Jup} deuterium burning, brown dwarf lower limit. Dynamical simulations incorporating this accurate mass for HD 38529c indicate that a near-Saturn mass planet could exist between the two known companions. We find weak evidence of an additional low amplitude signal that can be modeled as a planetary-mass ({approx}0.17 M {sub Jup}) companion at P {approx}194 days. Including this component in our modeling lowers the error of the mass determined for HD 38529c. Additional observations (RVs and/or Gaia astrometry) are required to validate an interpretation of HD 38529d as a planetary-mass companion. If confirmed, the resulting HD 38529 planetary system may be an example of a 'Packed Planetary System'.

79 ASTRONOMY AND ASTROPHYSICS↗