Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scanning Electron Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Understanding polaronic transport in complex oxides by combining precise synthesis and first-principles many-body theory

In complex oxides, charge carriers often couple strongly with lattice vibrations to form polarons–entangled electron–phonon quasiparticles whose transport properties remain difficult to characterize. Experimental access to intrinsic polaronic transport requires ultraclean samples, while theoretical description demands methods beyond low-order perturbation theory. Here, we show a predictive theory–experiment workflow to study polaron transport in complex oxides. Focusing on a prototypical polaronic oxide, anatase TiO 2 , we combine growth of high-quality oxygen-vacancy-doped films using hybrid molecular beam epitaxy with a first-principles electron–phonon diagrammatic Monte-Carlo (FEP-DMC) framework recently developed for accurate polaron predictions. Our films exhibit record-high electron mobility for anatase TiO 2 , in excellent agreement with FEP-DMC calculations conducted prior to experiment, which predict a room-temperature mobility of 45 ± 15 cm −2 V −1 s −1 and a mobility-temperature scaling of μ ∝ T −1.9 ± 0.077 . Microscopic analysis using scanning transmission electron microscopy and x-ray photoelectron spectroscopy reveals the role of oxygen vacancies in modulating transport at lower temperatures. FEP-DMC further provides quantitative insight into polaron formation energy, phonon cloud distribution, lattice distortion around the polaron, and the polaronic contribution to mobility. Together, these results provide a deeper microscopic understanding of large-polaron transport in a complex oxide and provide the blueprint to characterize other polaronic materials.

anatase TiO2↗

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

1D to 2D Transition in Tellurium Observed by 4D Electron Microscopy

A new microwave-enhanced synthesis method for the production of tellurium nanostructures is reported here—with control over products from the 1D regime (sub-5 nm diameter nanowires), to nanoribbons, to the 2D tellurene regime—along with a new methodology for local statistical quantification of the crystallographic parameters of these materials at the nanometer scale. Using a direct electron detector and image-corrected microscope, large and robust 4D scanning transmission electron microscopy datasets for accurate structural analysis are obtained. These datasets allow the adaptation of quantitative techniques originally developed for X-ray diffraction (XRD) refinement analyses to transmission electron microscopy, enabling the first demonstration of sub-picometer accuracy lattice parameter extraction while also obtaining both the size of the coherent crystallite domains and the nanostrain, which is observed to decrease as nanowires transition to tellurene. This new local analysis is commensurate with global powder XRD results, indicating the robustness of both the new synthesis approach and new structural analysis methodology for future scalable production of 2D tellurene and characterization of nanomaterials.

2D materials↗

Your Clean Graphene is Still Not Clean

Researchers working with thin samples, such as monolayer graphene, are consistently struggling against contamination. Indeed, the problem of hydrocarbon contamination is known from the earliest days of electron microscopy and efforts to reduce this problem are ubiquitous to almost all high-vacuum experiments. Accurate knowledge of the behavior of such contamination is essential for electron beam (e-beam) based atomic fabrication, where it is aspired to select and control matter on an atom-by-atom basis. Here, the vexing question of hydrocarbon contamination on graphene is taken up. Image intensity is used to directly reveal the presence of diffusing hydrocarbons on ostensibly clean graphene. These diffusing hydrocarbons are previously inferred but not directly observed. Surprising dynamic variations of the concentration of these hydrocarbons impels questions about their origin. Here, some possible explanations are presented and some tentative conclusions are drawn. This work updates the conceptual model of “clean graphene” and offers refinements to the description of e-beam induced hydrocarbon deposition.

atomic fabrication↗

Probing potential energy landscapes via electron-beam-induced single atom dynamics

Structure, bonding, and chemical dynamics of reactions at surfaces and interfaces, and therefore most material properties are intrinsically tied to the energetic landscape in which each atom resides. Here, we demonstrate that a moving atom under electron beam excitation can be used to probe the energy landscape along (confined) step edges, providing information about atomic-scale potentials. In conclusion, the techniques for experimentally exploring atomic potentials holds promise for predictive atom-by-atom fabrication using electron beams.

36 MATERIALS SCIENCE↗

Intrinsic Defects in MoS 2 Grown by Pulsed Laser Deposition: From Monolayers to Bilayers

Pulsed laser deposition (PLD) can be considered a powerful method for the growth of two-dimensional (2D) transition-metal dichalcogenides (TMDs) into van der Waals heterostructures. However, despite significant progress, the defects in 2D TMDs grown by PLD remain largely unknown and yet to be explored. In this work, we combine atomic resolution images and first-principles calculations to reveal the atomic structure of defects, grains, and grain boundaries in mono- and bilayer MoS 2 grown by PLD. We find that sulfur vacancies and MoS antisites are the predominant point defects in 2D MoS 2 . We predict that the aforementioned point defects are thermodynamically favorable under a Mo-rich/S-poor environment. The MoS 2 monolayers are polycrystalline and feature nanometer size grains connected by a high density of grain boundaries. In particular, the coalescence of nanometer grains results in the formation of 180° mirror twin boundaries consisting of distinct 4- and 8-membered rings. We show that PLD synthesis of bilayer MoS 2 results in various structural symmetries, including AA' and AB, but also turbostratic with characteristic moiré patterns. Moreover, we report on the experimental demonstration of an electron beam-driven transition between the AB and AA' stacking orientations in bilayer MoS 2 . These results provide a detailed insight into the atomic structure of monolayer MoS 2 and the role of the grain boundaries on the growth of bilayer MoS 2 , which has importance for future applications in optoelectronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of cation stoichiometry on surface morphology and crystallinity of ZnGeN 2 films grown on GaN by metalorganic chemical vapor deposition

ZnGeN 2 films were grown on GaN-on-sapphire templates via metalorganic chemical vapor deposition. Energy dispersive X-ray spectroscopy was used to estimate the Zn/(Zn+Ge) composition ratio in the films. This ratio decreased with increase in growth temperature but increased with increase in total reactor pressure or Zn/Ge precursor flow rate ratio. Systematic mapping of these key growth parameters has allowed us to identify the growth window to achieve ZnGeN 2 with stoichiometric cation composition. Compositional and statistical analyses performed on data acquired from atom probe tomography provided insight into the local compositional homogeneity. The cations Zn and Ge did not demonstrate segregation or clustering at the sub-nanometer level. Based on X-ray diffraction 2θ-ω scan profiles and transmission electron microscope nano-diffraction patterns, the films with near-stoichiometric cation ratios were single crystalline with planar surfaces, whereas zinc-rich or zinc-poor films were polycrystalline with nonplanar surfaces. The growth direction of the single crystalline ZnGeN 2 films on GaN templates was along the c-axis. Room temperature Raman spectra showed features associated with the phonon density of states, indicating the presence of cation disorder in the lattice. A cathodoluminescence peak associated with transitions involving deep level defects was observed around 640 nm. The intensity of this peak increased by almost 2.5 times as the temperature was reduced to 77 K from room temperature. A similar peak was observed in photoluminescence spectra collected at 80 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct matter disassembly via electron beam control: electron-beam-mediated catalytic etching of graphene by nanoparticles

Here, we report electron-beam activated motion of a catalytic nanoparticle along a graphene step edge and associated etching of the edge. The catalytic hydrogenation process was observed to be activated by a combination of elevated temperature and electron beam irradiation. Reduction of beam fluence on the particle was sufficient to stop the process, leading to the ability to switch on and off the etching. Such an approach enables the targeting of individual nanoparticles to induce motion and beam-controlled etching of matter through activated electrocatalytic processes. The applications of electron-beam control as a paradigm for molecular-scale robotics are discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study to determine the aquatic biological effects on the Solid Rocket Booster (SRB)

The surface of the reusable solid rocket boosters (SRB), which are jettisoned from the Shuttle Orbiter to parachute in the sea, are studied for colonization by marine life. Techniques for monitoring the marine microbial fouling of SRB materials are presented. An assessment of the nature and degree of the biofouling expected on the SRB materials in the recovery zone is reported. A determination of the degree and the effects of seasonal variation occurring on microbial fouling in the retrieval zone waters is made. The susceptibility of the SRB parachute recovery system to microbial fouling and biodeterioration is investigated. The development of scanning electron microscopy and epifluorescence microscopic observation techniques for rapid assessment of microbial fouling is discussed.

Colwell, R. R.↗

Ballistic-Electron-Emission Microscope

Ballistic-electron-emission microscope (BEEM) employs scanning tunneling-microscopy (STM) methods for nondestructive, direct electrical investigation of buried interfaces, such as interface between semiconductor and thin metal film. In BEEM, there are at least three electrodes: emitting tip, biasing electrode, and collecting electrode, receiving current crossing interface under investigation. Signal-processing device amplifies electrode signals and converts them into form usable by computer. Produces spatial images of surface by scanning tip; in addition, provides high-resolution images of buried interface under investigation. Spectroscopic information extracted by measuring collecting-electrode current as function of one of interelectrode voltages.

Kaiser, William J.↗

Nonlinear Acoustical Assessment of Precipitate Nucleation

The purpose of the present work is to show that measurements of the acoustic nonlinearity parameter in heat treatable alloys as a function of heat treatment time can provide quantitative information about the kinetics of precipitate nucleation and growth in such alloys. Generally, information on the kinetics of phase transformations is obtained from time-sequenced electron microscopical examination and differential scanning microcalorimetry. The present nonlinear acoustical assessment of precipitation kinetics is based on the development of a multiparameter analytical model of the effects on the nonlinearity parameter of precipitate nucleation and growth in the alloy system. A nonlinear curve fit of the model equation to the experimental data is then used to extract the kinetic parameters related to the nucleation and growth of the targeted precipitate. The analytical model and curve fit is applied to the assessment of S' precipitation in aluminum alloy 2024 during artificial aging from the T4 to the T6 temper.

Cantrell, John H.↗

Single-Molecule Electron Transport in Peptoids

Peptoids are structural analogs of peptides in which side chains are appended to the backbone nitrogen rather than the α-carbon. The sequence-defined modularity of peptoids enables precise control over structure−function relationships, enabling applications in energy storage and biomedical materials. Despite recent progress, the role of sequence and conformation on electron transport in peptoid molecules is not fully understood. Here, we synthesize a library of peptoid oligomers and characterize their molecular electronic properties using the scanning tunneling microscope-break junction (STM-BJ) technique. Our results show well-defined electron transport behavior for peptoid sequences containing aromatic side groups lacking hydrogen bonds (H-bonds) and without chemical substitutions at the N−C α position. This behavior fundamentally differs from electron transport in peptides, where H-bond interactions give rise to higher conductance states. All-atom molecular dynamics (MD) simulations are used to understand the conformational heterogeneity of peptoids, and molecular conformations obtained from MD simulations are used in quantum mechanical calculations based on the nonequilibrium Green’s function−density functional theory (NEGF-DFT) formalism. In all cases, computational results are in reasonable qualitative agreement with experiments. Our work demonstrates that the conductance behavior of peptoids depends on monomer identity, including side-chain aromaticity and substitution at the N−C α position. Overall, this work provides new insights into the structure−function relationships governing electron transport in peptoid-based materials and establishes design rules for peptoid-based molecular junctions.

Charge transport↗

Corrosion Failure in Electronic Devices for Aerospace Application

Corrosion of complex electronic systems is a growing and expensive concern. New materials and technology are constantly being introduced to increase performance of devices. There are many factors that can induce a corrosive environment during the various stages of manufacturing, processing, transport, and storage of these devices. The scope of this paper was to identify potential causes for the corrosion failure of optocoupler batches being used in launch applications. Optical microscope with surface profile measurements, scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDS), and X-ray photoelectron spectroscopy (XPS) were used to identify and analyze the source of these failure. These studies revealed that the loss of adhesion between the electrolytic plated gold and nickel layers is the critical area that traps impurity ions into the chip allowing for blisters to form along the pins of the optocoupler.

Corrosion↗

Surface grain refinement of casting A380 aluminum alloy by ultrasonic-assisted surface mechanical grinding treatment

A novel surface processing technique, ultrasonic-assisted surface mechnical grinding treatment (U-SMGT), was proposed and applied to modify the surface micriostructure of the casting aluminum alloy (A380). Comprehensive post-process chracterization techniques including 3D profilometry, optical microscope, scanning electric microscopy (SEM), and electron backscatter diffraction (EBSD) were carried out to investigate the surface morphology and microstructure of the processed region (PR). It was found that a surface layer of grain refinement with a thickness of about 50 µm was formed. In the as-received base material (BM), large clusters of dendritic eutectic phase with a size of approximately 20 µm were isolated by α-Al matrix. Nano-indentation tests showed that hardness of the eutectic and α-Al in the as-received BM was 2.15 GPa and 1.2 GPa respectively. After U-SMGT, the large dendritic eutectic phase was broken down into much fine particles with an average size of 0.57 µm. These fine particles were uniformly distributed into the α-Al matrix. Nano-indentation measurement exhibited a hardness of 2.27 GPa within the processed region. The overall high hardness in the processed region is a result of the pinning effect of uniformly distributed fine dendrites and grain refinement of Al-matrix.

36 MATERIALS SCIENCE↗

Micromachined Electron-Tunneling Infrared Detectors

Pneumatic/thermal infrared detectors based partly on Golay-cell concept, but smaller and less fragile. Include containers filled with air or other gas trapped behind diaphragms. Infrared radiation heats sensors, causing gas to expand. Resulting deflections of diaphragms measured by displacement sensors based on principle of electron-tunneling transducers of scanning tunneling microscopes. Exceed sensitivity of all other miniature, uncooled infrared sensors presently available. Expected to include low consumption of power, broadband sensitivity, room-temperature operation, and invulnerability to ionizing radiation.

Kenny, Thomas W.↗

Automated Construction of Artificial Lattice Structures with Designer Electronic States

Manipulating matter with a scanning tunneling microscope (STM) enables the creation of atomically defined artificial structures that host designer quantum states. However, the time-consuming nature of the manipulation process, coupled with the sensitivity of the STM tip, constrains the exploration of diverse configurations and limits the size of the designed features. In this study, we present a reinforcement learning (RL)-based framework for creating artificial structures by spatially manipulating carbon monoxide (CO) molecules on a copper substrate by using the STM tip. The automated workflow combines molecule detection and manipulation, employing deep-learning-based object detection to locate CO molecules and linear assignment algorithms to allocate these molecules to designated target sites. We initially perform molecule maneuvering based on randomized parameter sampling for sample bias, tunneling current set point, and manipulation speed. This data set is then structured into an action trajectory used to train an RL agent. The model is subsequently deployed on the STM for real-time fine-tuning of the manipulation parameters during structure construction. Our approach incorporates path-planning protocols coupled with active drift compensation to enable atomically precise fabrication of structures with significantly reduced human input while realizing larger-scale artificial lattices with the desired electronic properties. Furthermore, using our approach, we demonstrate the automated construction of an extended artificial graphene lattice and confirm the existence of a characteristic Dirac point in its electronic structure. Further challenges regarding the RL-based structural assembly scalability are discussed.

Algorithms↗