First principles calculation of finite temperature magnetism in Fe and Fe 3 C
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Density functional calculations have proven to be a useful tool in the study of ground state properties of many materials. The investigation of finite temperature magnetism, on the other hand, has to rely usually on the usage of empirical models that allow the large number of evaluations of the systems Hamiltonian that are required to obtain the phase space sampling needed to obtain the free energy, specific heat, magnetization, susceptibility, and other quantities as function of temperature. We have demonstrated a solution to this problem that harnesses the computational power of today s large massively parallel computers by combining a classical Wang Landau Monte-Carlo calculation [F. Wang and D. P. Landau, Phys. Rev. Lett. 86, 2050 (2001)] with our first principles multiple scattering electronic structure code [Y. Wang et al., Phys. Rev. Lett. 75, 2867 (1995)] that allows the energy calculation of constrained magnetic states [M. Eisenbach et al., Proceedings of the Conference on High Performance Computing, Networking, Storage and Analysis (ACM, New York, 2009)]. We present our calculations of finite temperature properties of Fe and Fe3C using this approach and we find the Curie temperatures to be 980 and 425K, respectively.
Nuclear power is an economical means of providing carbon-free energy, but requires effective ways to deal with the radioactive waste products. As part of the overall process for recycling used nuclear fuel (UNF), it is necessary to develop technologies to separate the off-gases formed during the fission of uranium and plutonium in nuclear power reactors. The off-gas contains {sup 129}I (radioisotope), NO, NO{sub 2}, CO{sub 2} containing {sup 14}C (radioisotope), {sup 3}H{sub 2}O (radioactive tritium oxide), {sup 85}Kr (radioisotope), and {sup 136}Xe. Separating and capturing each gas is essential to reduce the volume of radioactive waste for storage. Currently there exist economical technologies to separate {sup 129}I and {sup 14}CO{sub 2}. However, Kr and Xe separation is challenging because they are chemically inert and physically very similar. The Kr/Xe mixture is approximately 10/90 by volume and hence the separation of Kr would reduce the volume of radioactive {sup 85}Kr waste by a factor of 10. One way of separating them is by cryogenic distillation wherein they are condensed out as pure streams at very low temperature (Kr boiling point: -153 deg. C, Xe: -108 deg. C). Cryogenic distillation has intensive power requirements and a large system volume, resulting in high capital, operating, and disposal costs. Membrane-based separation using radiation-stable materials such as nanoporous zeolites is an attractive alternative, if membranes with sufficient Kr flux and selectivity can be fabricated. An ideal membrane process would permeate a stream of pure Kr for storage and also produce a retentate of pure Xe which has commercial value (> $8/g at 99+% purity from Airgas{sup R}). Zeolites are nanoporous crystalline aluminosilicate materials with pores that are capable of separating molecules by shape and size. SAPO-34 is a silicoaluminophosphate zeolite with pore size of 0.38 nm. The SAPO-34 is a molecular sieve composed of 3D networks with CHA frame structure containing uniform micropores. Since this pore size is intermediate between the kinetic diameters of krypton (0.36 nm) and xenon (0.396 nm), it was hypothesized that SAPO-34 membranes can separate krypton and xenon by diffusivity differences. Previously we fabricated SAPO-34 membranes and showed that they are capable of separating Kr from Xe. Here we describe a more detailed study of the fundamental adsorption and transport properties of SAPO34. In particular, the permeabilities of Kr and Xe in SAPO-34 are dependent on both their adsorption and diffusion characteristics in the nanoporous zeolite. Typically, nanoporous materials show stronger adsorption of Xe than Kr (due to stronger van der Waals forces) but faster diffusion of Kr (due to smaller kinetic diameter). Therefore the overall membrane selectivity towards Kr will be determined by competition between these two effects. A main objective of this study is to quantify and understand adsorption, diffusion, and permeation in detail and thereby obtain: (1) fundamental parameters useful for design calculations of a Kr/Xe separation membrane process, and (2) an experimental and modeling framework that can provide guidance on the expected limits of performance of SAPO-34 and other zeolite materials. (authors)
The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.
This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.
Mesophase pitch (MP)/exfoliated graphite nanoplatelets (GNPs) nanocomposite has been prepared by an efficient method with an initiation of graphite intercalation compounds (GIC). X-ray diffraction, optical microscopy, high-resolution transmission electron microscopy and scanning electron microscopy analysis techniques are used to characterize the samples. It is observed that GIC has exfoliated completely into GNPs during the formation of MP/GNPs nanocomposite and the GNPs are distributed uniformly in MP matrix, which represent a conductive path for a movement of electrons throughout the composites. Electrochemical tests demonstrate that the carbonized MP/GNPs nanocomposite displays higher capacity and better cycle performance in comparison with the pure carbonized MP. It is concluded that such a large improvement of electrochemical performance within the nanocomposite may in general be related to the enhanced electronic conductivity, which is achieved by good dispersion of GNPs within MP matrix and formation of a 3D network of GNPs. - Graphical abstract: Uniform mesophase pitch/exfoliated graphite nanoplatelets nanocomposite has been efficiently fabricated with an initiation of graphite intercalation compounds. The as-prepared composite electrode exhibited high electrochemical performance for Li-ion batteries.
An accurate understanding of the competitive adsorption of CH 4 -CO 2 binary mixtures in nano-confined systems is critical for engineering CO 2 storage in shale gas reservoirs. Due to difficulties in making reliable experimental observations in nano-scale, atomistic simulations (ASs), such as the Grand Canonical Monte Carlo (GCMC) method, provide a viable approach to studying the adsorption behavior of confined fluids. ASs are, however, limited in the size of the compositional domain due to the high computational cost. This work proposes a framework that combines AS and the lattice Boltzmann (LB) method to bridge the physics of confined fluids across scales. The Peng–Robinson equation of state (PR-EoS) produces fugacity coefficients, which serve as input for conducting multi-component GCMC simulations. These GCMC simulations explore the competitive adsorption behavior of CH 4 -CO 2 in nano-slits at various composition, pressure, and channel-width conditions. Both components generate adsorption layers with high densities near the walls with CO 2 preferentially adsorbing compared to CH 4 on the organic walls of carbon sheets. At the mesoscale, a pseudopotential model represents the intermolecular forces in multi-component, multiple-relaxation-time LB simulations. The LB simulations are in good agreement with the GCMC results, allowing us to obtain values for tunable LB parameters. We then extend the use of LB to simulate adsorption behavior in complex networks with nano-sized channels. The phase behavior and fluid properties in the complex geometries of nano-channels differ from nano-slits and bulk systems. Furthermore, the bridging of physics from GCMC (microscale) to LB (mesoscale) via the macroscale PR-EoS connects the adsorption behavior of binary systems across scales.
The fundamental understanding of the liquid electrolyte (LE) solvation structure and electrode–electrolyte interface behavior will bring more in-depth thinking and revolutionary changes to the entire electrochemical energy storage field. Regardless of the variety of techniques available, the methods employed to investigate electrolyte solvation structures over a long-range are severely limited. Small-angle X-ray scattering (SAXS) is an ideal complement to Raman spectroscopy, Fourier transform infrared spectroscopy, or nuclear magnetic resonance, which offers a unique perspective from a larger scale on clusters or networks in electrolytes. Understanding the solvation structures from a few angstroms to hundreds of nanometers will undoubtedly lay a good foundation for studying the macroscopic transport properties, such as viscosity and ionic conductivity, of the LEs. Here, in this Perspective, we discuss the use of SAXS to investigate the solvation structures in different electrolyte systems, a prospect for the SAXS broader application in the electrolyte study, and some challenges that need to be solved in the SAXS application.
Aquifer thermal energy storage (ATES) is a concept that can help to address heating and cooling needs through the use of the subsurface as a seasonal thermal energy storage (STES) system. Over 2800 ATES systems have been deployed with storage temperatures typically below 25 °C and only a few with higher temperatures (>40 °C), which would increase the energy density and utility of the stored thermal fluids. Until now, only a few high-temperature aquifer thermal energy storage (HT-ATES) projects have been initiated and are still in operation. These HT-ATES projects have encountered a range of technical and non-technical challenges. This study reviews ten such projects: four in Germany and six in the Netherlands. The non-technical issues include public acceptance, a lack of regulatory framework for these systems, managing overlapping uses of the subsurface, managing changes with the providers and off-takers of thermal energy, and obtaining financing to implement these projects. Common technical issues include geological factors such as incomplete characterization of the subsurface and reservoir heterogeneity; geochemical issues such as mineral scaling, corrosion, and biofouling; lower than expected thermal recovery; and issues with system design and reliability. This review highlights benefits and challenges faced by HT-ATES projects with the goal to use the lessons learned to improve the siting, design, development, and operation of such systems. Recommendations include improved initial subsurface site characterization, use of coupled process models to optimize system design and predict system performance, cascaded uses of stored thermal energy to better utilize the stored heat, monitoring networks to provide feedback on system performance, and expanded system scale to allow for continued operation even when maintenance of some system components is required. Techno-economic modeling and risk analysis could be used to optimize such HT-ATES project design and identify key factors that will affect sustained economic viability. In addition, design flexibility is important for these systems to allow for changing conditions regarding the supply and demand of thermal energy. Adopting these findings should improve the performance and reduce the risks for future HT-ATES projects worldwide.
This paper presents an algorithm to optimally aggregate spatially distributed flexible resources at strategic microgrid/smart-grid locations. The aggregation reduces a distribution network having thousands of nodes to an equivalent network with a few aggregated nodes, thereby enabling distribution system operators (DSOs) to make faster operational decisions. Moreover, the aggregation enables flexibility from small distributed flexible resources to be traded to different power and energy markets. A hierarchical control architecture comprising a combination of centralized and decentralized control approaches is proposed to practically deploy the aggregated flexibility. The proposed method serves as a great operational tool for DSOs to decide the exact amount of required flexibilities from different network section(s) for solving grid constraint violations. The effectiveness of the proposed method is demonstrated through simulation of three operational scenarios in a real low voltage distribution system having high penetrations of electric vehicles and heat pumps. Finally, the simulation results demonstrated that the aggregation helps DSOs not only in taking faster operational decisions, but also in effectively utilizing the available flexibility.
NREL's TEMPEST model combines electrical and thermal modeling for residential-scale battery systems. The model and default parameters are based off of two common commercial residential batteries. Key inputs to the model include house load, temperature of the battery location, and the solar profile. The key output of the TEMPEST model is the battery profile and internal battery temperature. If internal battery temperature exceeds limits, a derating will occur and this will be reflected in the battery profile. In addition to thermal modeling, the TEMPEST model uses realistic operating principals that are common in today's residential batteries. Mainly, the TEMPEST model incorporates "modes" of operation that constrain battery setpoint based on house load, solar output, and state of charge. The TEMPEST model can be used to analyze the effect of battery temperature, deratings, and mode setpoints on utility network loading and customer bills.
As a large number of distributed devices are connected to the modern smart grid, the traditional centralized connectivity models fail to provide economic value. These models have relied on sending data to the cloud for processing and receiving commands to exert control actions, resulting in an ‘on-demand system’ with high bandwidth, low latency and an overload of data on the cloud. For realizing a decentralized system, there is a strong need to embed intelligence at the ‘edge of the network’. These intelligent devices, capable of sensing, local data processing and exerting control actions, report only actionable information to the cloud, acting as an edge control node. The system can then function autonomously, without constant cloud inputs, tolerating longer delays in communication, making the overall system ultra-low cost. The Global Asset Monitoring, Management and Analytics (GAMMA) Platform is a novel ultralow- cost, secure platform that operates through a Bluetooth based delay tolerant network. It relies on so-called ‘data mules’ to bridge the last mile connectivity gap in an inherently secure way. Due to this model, the platform requires no in-country certifications, does not rely on a dedicated backhaul technology and is immune to technology migration. This architecture also addresses some gaps identified in traditional IoT-based solutions in remote areas and sparse connectivity. A functional unit of the edge computing node has been built, taking into account various constraints like costs, customizations, data storage, cybersecurity and power management. Here, the platform has been built, deployed and has demonstrated distributed smart grid applications like power quality sensing, automated metering infrastructure and utility asset monitoring.
With the expansion of renewable energy resources in the electric power systems, having flexibility in the setup will allow to maintain the system's reliability and prevailing operations. Such flexibility can be extracted from utility operated and/or consumer owned devices, such as, storage devices, electric vehicles, etc. For the demand side, generally consumer preferences, incentives, etc. enact on the availability of the flexibility; besides, both the spatial and temporal dimension dictates the degree of the flexibility. Consequently, the optimal dispatch of the grid resources might appear intractable as the considerable amount of flexibility are obliquely stemming from the ungovernable consumer devices. Thus characterizing the consequences of diverged feasible flexibility in the system is crucial for operations. In this paper, a procedure is developed to quantify the degree of flexibility of power systems in terms of resource dispatch reconfiguration. Specifically, we develop optimization problems to attain equivalent resource configurations for the power systems to evaluate the spatial volatility of the network and asses the flexibility of the system. The developed process is then validated using numerical simulations for IEEE-30 bus test system.
The use of a low-power solar network and standalone power plants is the most promising for the needs of the housing and utilities sector, small industrial enterprises, social and public health facilities, recreation areas, remote objects, and agricultural industries; this will make it possible to reduce the load on the energy system at peak moments, as well as to decrease losses when transporting electric energy in its elements. It is assumed that the minimum value of the unit cost of generated electric energy is used as the criterion for configuring and selecting the parameters of solar power equipment, which will make it possible to set up an economically feasible additional power supply to the consumer, since it excludes the use of storage devices and rearrangement of the power supply system.
One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.
High-energy density anodes are crucial for next-generation lithium-ion batteries (LIBs) particularly for electric vehicle (EV) applications. Sluggish lithium-diffusion kinetics coupled with conventional anode fabrication processes containing polymeric binders hinder fast-charging capabilities and high-energy density of graphite. Herein, we introduce a binder-free graphite anode fabrication strategy using the electrospinning technique that contains ~2.41% carbon nanotubes (CNTs). Our strategy relies on the formation of an interconnecting conductive CNT network coupled with an ultrathin N-doped carbon coating on graphite particles from sacrificial binders. This combination enhances both structural integrity and electrical conductivity and, in turn, improves fast-charging capabilities and high energy density of LIBs. The binder-free graphite anode achieves ~335.0 mAh g–1 capacity at C/3 rate over 400 cycles with capacity retention of >95% and average Coulombic efficiencies >99.95%. These promising results suggest that the binder-free anode fabrication with a multifunctional design approach could elevate the energy-density limits of the graphite anodes, solving high-energy density requirements of EVs, and potentially provides a path forward for the development of economically feasible energy storage systems for various applications.
The Paluxy formation is being considered as a prospective CO 2 reservoir at the Kemper County CO 2 Storage Complex. Herein, the pore and pore-throat size distributions and connectivity of the Paluxy formation is evaluated through analysis of 3D X-ray Computed Tomography images. In spite of resolution limitations that constrain the pore-throat sizes detectable by imaging, the permeability contributing pore-throats are successfully characterized through 3D imaging analysis. Image-obtained pore and pore-throat size distributions and pore connectivity are then utilized to construct pore network models and simulate permeability. After CO 2 is injected, it will dissolve into formation brine and create conditions favorable for dissolution of primary minerals and precipitation of secondary minerals. These reactions will alter the porosity and permeability of the system to varying degrees depending on the spatial location of reactions. In this research, the possible porosity-permeability evolution is simulated using pore network models considering mineral reactions occurring uniformly and non-uniformly throughout the network. For a given change in porosity, there is a large range of possible permeability outcomes. Depending on the extent and spatial location of mineral reactions, permeability may decrease by more than one order of magnitude as minerals precipitate. During dissolution, simulated permeability increases as much as 500%.
The modern power grid is seeing more and more electricity come from renewable sources like wind farms, which use sophisticated power electronics instead of traditional spinning generators. To keep everything running smoothly and meet industry standards such as IEEE 2800, these systems need smart control strategies. In our work, we built a flexible computer model of a full-scale wind farm converter that can handle grid disturbances without shutting down. When a fault or storm hits, the model’s built-in logic automatically adjusts the currents it sends to the grid and protects its internal energy storage, ensuring the wind farm stays connected and doesn’t damage its own equipment. Once the disturbance clears, the model restores normal operation seamlessly, so there’s no long interruption in power delivery. At the same time, it carefully regulates the voltage where the wind farm ties into the larger grid, helping to maintain safe voltage levels across the network. Our simulations show that this control setup not only meets all the requirements of IEEE Standard 2800 but also allows the wind farm to recover quickly and predictably, keeping the lights on no matter what happens on the grid.