Recent performance of the SNS H - ion source with a record long run

The Spallation Neutron Source (SNS) accelerator system includes a 65 keV H - injector, a 2.5 MeV radio frequency quadrupole (RFQ), a 1 GeV linac chain (DTL-CCL-SCL) and an accumulator ring. The H - injector consists of an RF-driven, Cs-enhanced, multi-cusp H - ion source and a compact, two-lens electrostatic low energy beam transport (LEBT). In 2018, a new RFQ was installed in place of the original RFQ along with upgraded ion source support infrastructure. This paper presents the operational performance and some highlights of beam studies with the SNS ion source since the new RFQ was put into operation. SNS routinely operates at 1.4 MW average beam power for three run cycles per year. During the most recently finished run, FY20B, we operated a single source for the entire run spanning ~4 months with a >99.5% availability. A single dose of cesiation was conducted during the ion source startup which yielded ≥54 mA current for the entire run with just few minor adjustments of parameters.

Han, Baoxi↗

Constrained model calibration of grain structure dependent spall dynamics in shock-loaded tantalum

Here, we perform a gas gun experiment by shock loading tantalum samples of varying grain structures to assess the suitability of a numerical model for simulating spall behavior. The observed differences in spall strength, as well spallation and re-compression history, are not captured in uncalibrated hydrodynamic simulations. An optimization is performed on the Johnson spall model to determine the best parameters that fit the observed trends. Linear stability analysis is employed to motivate bounds on those parameters. Herein, optimized simulations agree well with the experimental results, reproducing pullback depth and recompression timescales across the different samples tested. Further, the observed pullback time of the single crystal sample was found to imply, via the stability analysis, a percolation threshold in good agreement with the theoretical value for a body centered cubic lattice. Therefore, the combined linear stability and percolation analysis shows promise and may be applied to other materials with diverse microstructures. Collectively, the findings demonstrate that the model is suitable for reproducing spall-induced free surface behavior across various microstructures, but also points to caution in using model coefficients for uncalibrated microstructures.

58 GEOSCIENCES↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Magnetic pair distribution function data using polarized neutrons and ad hoc corrections

Here, we report the first example of magnetic pair distribution function (mPDF) data obtained through the use of neutron polarization analysis. Using the antiferromagnetic semiconductor MnTe as a test case, we present high-quality mPDF data collected on the HYSPEC instrument at the Spallation Neutron Source using longitudinal polarization analysis to isolate the magnetic scattering cross section. Clean mPDF patterns are obtained for MnTe in both the magnetically ordered state and the correlated paramagnet state, where only short-range magnetic order is present. We also demonstrate significant improvement in the quality of high-resolution mPDF data through the application of ad hoc corrections that require only minimal human input, minimizing potential sources of error in the data processing procedure. We briefly discuss the current limitations and future outlook of mPDF analysis using polarized neutrons. Overall, this work provides a useful benchmark for mPDF analysis using polarized neutrons and provides an encouraging picture of the potential for routine collection of high-quality mPDF data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implementation of a laser–neutron pump–probe capability for inelastic neutron scattering

Knowledge about nonequilibrium dynamics in spin systems is of great importance to both fundamental science and technological applications. Inelastic neutron scattering (INS) is an indispensable tool to study spin excitations in complex magnetic materials. However, conventional INS spectrometers currently only perform steady-state measurements and probe averaged properties over many collision events between spin excitations in thermodynamic equilibrium, while the exact picture of re-equilibration of these excitations remains unknown. In this paper, we report on the design and implementation of a time-resolved laser–neutron pump–probe capability at hybrid spectrometer (beamline 14-B) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. This capability allows us to excite out-of-equilibrium magnons with a nanosecond pulsed laser source and probe the resulting dynamics using INS. Here, we discussed technical aspects to implement such a capability in a neutron beamline, including choices of suitable neutron instrumentation and material systems, laser excitation scheme, experimental configurations, and relevant firmware and software development to allow for time-synchronized pump–probe measurements. We demonstrated that the laser-induced nonequilibrium structure factor is able to be resolved by INS in a quantum magnet. In conclusion, the method developed in this work will provide SNS with advanced capabilities for performing out-of-equilibrium measurements, opening up an entirely new research direction to study out-of-equilibrium phenomena using neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A convergence metric for counting statistics in time-resolved small angle neutron scattering

Here, this work introduces a model-independent, dimensionless metric for predicting optimal measurement duration in time-resolved small-angle neutron scattering using early-time data. Built on a Gaussian process regression framework, the method reconstructs scattering profiles with quantified uncertainty, even from sparse or noisy measurements. Demonstrated on the EQ-SANS instrument at the Spallation Neutron Source, the approach generalizes to general SANS instruments with a two-dimensional detector. A key result is the discovery of a dimensionless convergence metric revealing a universal power-law scaling in profile evolution across soft matter systems. When time is normalized by a system-specific characteristic time t*, the variation in inferred profiles collapses onto a single curve with an exponent between −2 and −1. This trend emerges within the first ten time steps, enabling early prediction of measurement sufficiency. The method supports real-time experimental optimization and is especially valuable for maximizing efficiency in low-flux environments such as compact accelerator-based neutron sources.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

An algebraic convolution formulation for multiple-scattering correction in small-angle neutron scattering

Multiple scattering in small-angle neutron scattering (SANS) redistributes spectral weight and distorts structural interpretation, particularly for thick or strongly scattering samples. We develop a finite-dimensional spectral desmearing framework that corrects multiple scattering without resorting to integral transforms or model-dependent extrapolation. The primary intensity is expanded in an orthonormal basis adapted to the isotropic transverse-momentum measure, under which convolution reduces to a recursive tensor contraction, allowing the Poisson-weighted multiple-scattering series to be evaluated directly in a finite-dimensional basis representation. This formulation yields a stable forward–inverse mapping between apparent and primary spectra. Numerical tests demonstrate convergence under repeated convolution and accurate recovery of the single-scattering intensity. Application to SANS measurements collected at multiple neutron facilities, including the Spallation Neutron Source, the High Flux Isotope Reactor, and the Institut Laue-Langevin, shows the quantitative reconstruction of the underlying primary spectrum across a wide range of transmission conditions, including strongly attenuating samples. Here, the method provides a stable, model-agnostic framework for multiple-scattering correction in SANS and enables consistent structural interpretation across instruments and scattering regimes.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Constrained variational optimization of counting-time allocation in sequential scattering measurements: Application to Bonse–Hart USANS

Sequential scattering measurements are often performed under a fixed experimental-time budget, even though the expected count rate varies strongly across the measured coordinate. When the dwell time at each measurement position can be controlled independently, this variation creates a general resource-allocation problem: how should the available time be distributed to minimize the uncertainty of the reconstructed profile? We formulate this problem as a constrained variational optimization for measurements governed by Poisson counting statistics. When each measurement is treated independently, minimizing the averaged squared relative uncertainty yields an inverse-square-root intensity allocation. The formulation is then generalized to include correlations between neighboring measurements and an instrumental resolution operator, leading to an allocation criterion that equalizes the marginal reduction in posterior uncertainty per unit measurement time. Bonse–Hart ultra-small-angle neutron scattering (USANS), in which reciprocal space is sampled sequentially through analyzer-angle stepping, provides an experimentally grounded application. Computational benchmarking shows that the optimized allocation outperforms uniform-time and constant-relative-error strategies, while application to an experimentally measured graphite USANS profile from the Spallation Neutron Source, using Poisson resampling under alternative schedules, demonstrates how counting time should be redistributed toward weak-intensity regions under an identical total duration. The resulting framework applies to sequential scattering and related scanning measurements whenever local dwell times are adjustable and directly determine the measurement uncertainties, and when the relevant correlation and instrumental-response models are available.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Methodology for Generating Covariance Data of Thermal Neutron Scattering Cross Sections

This paper details and implements a framework for evaluating thermal neutron scattering cross sections that provide S(α,β) data and covariance data for hydrogen in light water. This methodology involves perturbing model parameters of molecular dynamics potentials and fitting the simulation results to experimental data. The framework is general and can be applied to any material or simulation method. The fit is made using the Unified Monte Carlo method to experimentally measure double-differential scattering cross sections of light water at the Spallation Neutron Source at Oak Ridge National Laboratory. Mean values and covariance data were generated for model parameters, phonon density of states, double-differential cross sections, and total scattering cross sections. These posterior parameter values were very similar to their prior values with a maximum relative error of 0.54%. This falls within in the Unified Monte Carlo–calculated uncertainties on the order of 2.7%. Additionally, posterior double-differential cross sections agree favorably with ENDF/B-VIII.0 cross sections. The new thermal scattering law was tested by comparing it against benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook, which showed a slight improvement over the ENDF/B-VIII.0 library. Additionally, the covariance matrix of the phonon density of states was validated to confirm that the spread of k eff from the density of states used to generate the covariance matrix was similar to the spread of k eff from the density of states of the sampled covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗

Wide-angle diamond cell for neutron scattering

Here, a new diamond cell with extreme apertures is described. It is tailored for a large variety of neutron scattering techniques such as inelastic neutron scattering and single-crystal diffraction both at the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Simple springs enable forces of over 10 metric tons to be clamped in for low-temperature measurements. At present, low-cost polycrystalline diamond (Versimax ® ) pressure anvils are used. We predict a routine pressure regime up to 20 GPa with sample volumes of ~0.5 mm3. Future use of large CVD single-crystal diamond anvils will significantly expand this pressure range. We show examples for measurements at the SNAP, VISION and CORELLI beamlines of the SNS.

42 ENGINEERING↗

Modified Bridgman anvils for high pressure synthesis and neutron scattering

A simple modified Bridgman design for large volume pressure anvils usable in the Paris-Edinburgh (PE) press has been demonstrated at Oak Ridge National Laboratory Spallation Neutron Source. The design shows advantages over the toroidal anvils typically used in the PE press, mainly rapid compression/decompression rates, complete absence of blow-outs upon drastic phase transitions, simplified cooling, high reliability, and relative low loads (~40 tons) corresponding to relatively high pressures (~20 GPa). It also shows advantages over existing large-volume diamond cells as sample volumes of ~2-3 mm 3 can be easily and rapidly synthesized. The anvils thus allow sample sizes sufficient for in situ neutron diffraction as well as rapid synthesis of adequate amounts of new materials for ex situ analysis via total neutron scattering and neutron spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic ordering in rare earth metal dysprosium revealed by neutron diffraction studies in a large-volume diamond anvil cell

A high-pressure low-temperature neutron diffraction study has been carried out on rare earth metal Dysprosium (Dy) to 10.8 GPa and 8 K in a large-volume diamond anvil cell using a spallation neutron source. Dy crystallizes in an ambient pressure hexagonal close packed phase and forms an incommensurate helical antiferromagnetic phase, marked by the appearance of superlattice magnetic peaks below 176 K with a turn-angle between the hexagonal layers that increases both with increasing temperature and pressure. The ferromagnetic transition below 87 K is marked by an increase in intensity of nuclear peaks with disappearance of magnetic superlattice reflections. Dy transforms to an alpha-Samarium ( α-Sm ) phase at 7 GPa and only ferromagnetic ordering is observed for this high pressure phase. Here, the ferromagnetic transition is observed at 59 K in the α-Sm phase at 10.8 GPa in close agreement with the magnetic ordering temperature obtained from electrical transport measurements. In the entire pressure-temperature range of this study, Dy shows a negative thermal expansion coefficient of as much as -2.5 % in the magnetically ordered phases between 200 K and 8 K.

36 MATERIALS SCIENCE↗

On single-crystal neutron-diffraction in DACs: quantitative structure refinement of light elements on SNAP and TOPAZ

Quantitative single crystal neutron-diffraction in diamond anvil cells has so far been limited by the neutron flux available at the various neutron sources. As a result, highly precise measurements of the exact position of light elements have not been possible preventing, for example, structural studies of hydrogen and hydrogen bonds under pressure. Here we report experiments carried out on SNAP at the Spallation Neutron Source (ORNL, TN, USA) to explore the possibility and current limits of such studies. Furthermore, we benchmarked the obtained data quality with reference experiments carried out on TOPAZ, a dedicated single-crystal instrument.We show that measuring single-crystal diffraction intensities on SNAP is possible to such a precision that we are able to resolve the hydrogen bonds in potassium dideuterium phosphate (DKDP) as well as in ice VI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel compact end-loaded piston cylinder cell for high pressure neutron scattering up to 5 GPa

Here, a miniature sized end-loaded piston cylinder cell with radial side windows for neutron scattering experiments is described. The principle of the bicone-shaped cylinders used was first presented by McWhan in 1974. The present cell is of compact portable design yet significantly enlarges the scattering angles. Its small size allows neutron scattering experiments at low temperatures. The bicone-shaped cylinders are made from various ceramics or a highly neutron-transmissive Ni-free Cr–Mo–V steel. Successful neutron scattering experiments up to 5 GPa have been demonstrated on the CORELLI single-crystal diffractometer and the VISION vibrational spectrometer of the Spallation Neutron Source at the Oak Ridge National Laboratory.

Neutrons↗

High-temperature behavior of oxide dispersion strengthening CoNiCrAlY

To fabricate oxide dispersion strengthened bond coatings, commercial Co–30wt-%Ni–20Cr–8Al–0•4Y powder was milled with 2% additions of Al2O3, Y2O3 or Y2O3 + HfO2. Low-pressure plasma sprayed, free-standing specimens were oxidised in air + 10%H2O at 1100 °C both isothermally (100 h) and in 500, 1-h cycles. Dry air cyclic testing conducted at both ORNL and FZJ showed remarkably similar results. In general, the water vapour addition caused more scale spallation. Two LPPS specimens without oxide additions were tested for comparison. The specimens with 2%Al2O3 addition exhibited the best behaviour as the powder already contained 0•4%Y. Additions of 2%Y2O3 and especially 1%Y2O3 + 1%HfO2 resulted in over-doping as evidenced by high mass gains and the formation of Y- and Hf-rich pegs. Scanning transmission electron microscopy of the isothermal specimens showed no Hf and/or Y segregation to the alumina scale grain boundaries in the over-doped specimens.

Unocic, Kinga A.↗

A review of the thermal expansion of magnetite

Thermal expansion data from various sources were placed on an equivalent basis and fitted true (α T ) and mean (α M ) coefficients of thermal expansion were generated. Recent models of oxide spallation in boiler tubes cite and use Central Electricity Generating Board (CEGB) data for αM, but details of how the CEGB data was generated were not known. Here, the CEGB data were found to be derived from an earlier source but given (unconventionally) in terms of small temperature step α M increments.

36 MATERIALS SCIENCE↗