Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLICING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Simple holography in general spacetimes

The simple or “outermost” wedge in AdS is the portion of the entanglement wedge that can be reconstructed with sub-exponential effort from CFT data. Here we furnish a definition in arbitrary spacetimes: given an input wedge a analogous to a CFT boundary region, the simple wedge z(a) is the largest wedge accessible by a “zigzag,” a certain sequence of antinormal lightsheets. We show that z(a) is a throat, and that it is contained in every other throat. This implies that z(a) is unique; that it is contained in the generalized entanglement wedge; and that it reduces to the AdS prescription as a special case. The zigzag explicitly constructs a preferred Cauchy slice that renders the simple wedge accessible from a; thus it adds a novel structure even in AdS. So far, no spacelike construction is known to reproduce these results, even in time-symmetric settings. This may have implications for the modeling of holographic encoding by tensor networks.

AdS-CFT Correspondence↗

Supersymmetric D3/D7 for holographic flavors on curved space

We derive a new class of supersymmetric D3/D7 brane configurations, which allow to holographically describe $N=4$ SYM coupled to massive $N=2$ flavor degrees of freedom on spaces of constant curvature. We systematically solve the $κ$-symmetry condition for D7-brane embeddings into AdS 4 -sliced AdS 5 ×S 5 , and find supersymmetric embeddings in a simple closed form. Up to a critical mass, these embeddings come in surprisingly diverse families, and we present a first study of their (holographic) phenomenology. We carry out the holographic renormalization, compute the one-point functions and attempt a field-theoretic interpretation of the different families. To complete the catalog of supersymmetric D3/D7 configurations, we construct analogous embeddings for flavored $N=4$ SYM on S 4 and dS 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hexagon functions and the three-loop remainder function

We present the three-loop remainder function, which describes the scattering of six gluons in the maximally-helicity-violating configuration in planar NN = 4 super-Yang-Mills theory, as a function of the three dual conformal cross ratios. The result can be expressed in terms of multiple Goncharov polylogarithms. We also employ a more restricted class of hexagon functions which have the correct branch cuts and certain other restrictions on their symbols. We classify all the hexagon functions through transcendental weight five, using the coproduct for their Hopf algebra iteratively, which amounts to a set of first-order differential equations. The three-loop remainder function is a particular weight-six hexagon function, whose symbol was determined previously. The differential equations can be integrated numerically for generic values of the cross ratios, or analytically in certain kinematic limits, including the near-collinear and multi-Regge limits. These limits allow us to impose constraints from the operator product expansion and multi-Regge factorization directly at the function level, and thereby to fix uniquely a set of Riemann ζ valued constants that could not be fixed at the level of the symbol. The near-collinear limits agree precisely with recent predictions by Basso, Sever and Vieira based on integrability. The multi-Regge limits agree with the factorization formula of Fadin and Lipatov, and determine three constants entering the impact factor at this order. We plot the three-loop remainder function for various slices of the Euclidean region of positive cross ratios, and compare it to the two-loop one. For large ranges of the cross ratios, the ratio of the three-loop to the two-loop remainder function is relatively constant, and close to -7.

extended supersymmetry↗

Carbon nanospikes have improved sensitivity and antifouling properties for adenosine, hydrogen peroxide, and histamine

Carbon nanospikes (CNSs) are a new nanomaterial that has enhanced surface roughness and surface oxide concentration, increasing the sensitivity for dopamine detection. However, CNS-modified electrodes (CNSMEs) have not been characterized for other neurochemicals, particularly those with higher oxidation potentials. The purpose of this study was to evaluate CNSMEs for the detection of adenosine, hydrogen peroxide (H 2 O 2 ), and histamine. The sensitivity increased with CNSs, and signals at CNSMEs were about 3.3 times higher than CFMEs. Normalizing for surface area differences using background currents, CNSMEs show an increased signal of 4.8 times for adenosine, 1.5 times for H 2 O 2 , and 2 times for histamine. CNSMEs promoted the formation of secondary products for adenosine and histamine, which enables differentiation from other analytes with similar oxidation potentials. Furthermore, CNSs also selectively enhance the sensitivity for adenosine and histamine compared to H 2 O 2 . A scan rate test reveals that adenosine is more adsorption-controlled at CNS electrodes than CFMEs. CNSMEs are antifouling for histamine, with less fouling because the polymers formed after histamine electrooxidation do not adsorb due to an elevated number of edge planes. CNSMEs were useful for detecting each analyte applied in brain slices. Because of the hydrophilic surface compared to CFMEs, CNSMEs also have reduced biofouling when used in tissue. Therefore, CNSMEs are useful for tissue measurements of adenosine, hydrogen peroxide, and histamine with high selectivity and low fouling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

R2 relaxometry based MR imaging for estimation of liver iron content: A comparison between two methods

Purpose: To compare the reproducibility and accuracy of R2-relaxometry MRI for estimation of liver iron concentration (LIC) between in-house analysis and FDA-approved commercially available third party results. Methods: All MR studies were performed on a 1.5T scanner. Multi-echo spin-echo scans with a fixed TR and increasing TE values of 6 ms, 9 ms, 12 ms, 15 ms, and 18 ms (spaced at 3 ms intervals) were used. Post-processing of the images to calculate mean relaxivity, R2, included drawing of regions of interest to include the whole liver on mid-slice. The relationship between liver R2 values and estimated LIC calculated with in-house analysis and values reported by an external company (FerriScan{sup ®}, Resonance Health, Australia) were assessed with correlation coefficients and Bland–Altman difference plots. Continuous variables are presented as mean ± standard deviation. Significance was set at p value < 0.05. Results: 474 studies from 175 patients were included in the study (mean age 10.4 ± 4.2 years (range 1–18 years); 254 studies from girls, 220 studies from boys). LIC ranged from 0.6 to 43 mg/g dry tissue, covering a broad range from normal levels to extremely high iron levels. Linearity between proprietary and in-house methods was excellent across the observed range for R2 (31.5 to 334.8 s{sup −1}); showing a correlation coefficient of r = 0.87, p < 0.001. Bland–Altman R2 difference plot between the two methods shows a mean bias of + 21.5 s{sup −1} (range − 47.0 to + 90.0 s{sup −1} between two standard deviations). LIC reported by FerriScan{sup ®} compared with LIC estimated in-house with R2 as reported by FerriScan{sup ®} agreed strongly, (r = 1.0, p < 0.001). Conclusion: R2 relaxometry MR imaging for liver iron concentration estimation is reproducible between proprietary FDA-approved commercial software and in-house analysis methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

5-Fluorouracil induced liver toxicity in patients with colorectal cancer: role of computed tomography texture analysis as a potential biomarker

Purpose: To assess if CT texture analysis (TA) can serve as a biomarker of liver toxicity in patients with colorectal cancer treated with 5-fluorouracil (5-FU)-based chemotherapy. Methods: In this IRB-approved, HIPAA-compliant retrospective study, patients with colorectal cancer treated with 5-FU-based regimens during 2008–2010 were identified from institutional electronic database. Total 43 patients (23 women; mean age 56 years) with normal baseline liver function tests (LFTs), availability of baseline (pre-chemotherapy) and first follow-up CT (median 1.7 months, interquartile range (IQR) 1.5–2.5) performed during chemotherapy were included. Two single-slice ROI of right and left liver lobe were obtained on baseline and first follow-up CT for TA. Texture features [mean, entropy, kurtosis, skewness, mean of positive pixel, standard deviation (SD)] were extracted using a commercially available software (TexRAD; Feedback Medical Ltd, Cambridge, UK). Changes in texture parameters between baseline and follow-up CT were evaluated with Wilcoxon signed-rank test for patients with and without LFT elevation during chemotherapy. Results: Patients with LFT elevation (n = 34; 79%) showed significantly different mean, entropy, skewness, and SD (p values range 0.007–0.047) between baseline and first follow-up CT. No significant changes in features were observed in patients without LFT elevation (n = 9; 21%). In 19 patients (56%), first follow-up CT was performed before elevation of LFTs was observed. Conclusions: This proof-of-concept study shows that there are early changes in liver texture on first follow-up CT in patients with LFT elevation during 5-FU-based chemotherapy for colorectal cancer. In more than 50% of cases, these changes occur before LFT elevation becomes evident on blood tests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Transjugular Intrahepatic Shunt on Cardiac Function Assessed by Cardiac MRI: Preliminary Results

The purpose of this study was to assess short-term effects of transjugular intrahepatic shunt (TIPS) on cardiac function with cardiac magnetic resonance imaging (MRI) in patients with liver cirrhosis. Eleven patients (six males and five females) with intractable esophageal varices or refractory ascites were imaged with MRI at 1.5 T prior to, within 24 h after, and 4-6 months after TIPS creation (n = 5). Invasive pressures were registered during TIPS creation. MRI consisted of a stack of contiguous slices as well as phase contrast images at all four valve planes and perpendicular to the portal vein. Imaging data were analyzed through time-volume curves and first derivatives. The portoatrial pressure gradient decreased from 19.8 {+-} 2.3 to 6.6 {+-} 2.3, accompanied by a nearly two fold increase in central pressures and pulmonary capillary wedge pressure immediately after TIPS creation. Left and right end diastolic volumes and stroke volumes increased by 11, 13, and 24%, respectively (p < 0.001), but dropped back to baseline at follow-up. End systolic volumes remained unchanged. E/A ratios remained within normal range. During follow-up the left ventricular mass was larger than baseline values in all patients, with an average increase of 7.9 g (p < 0.001). In conclusion, the increased volume load shunted to the heart after TIPS creation transiently exceeded the preload reserve of the right and left ventricle, leading to significantly increased pulmonary wedge pressures and persistent enlargement of the left and right atria. Normalization of cardiac dimensions was observed after months together with mild left ventricular hypertrophy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 Multiplication-Sign 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner's isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at {>=}150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r{sup 2} = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture

PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Feasibility of Isolated Pancreatic Perfusion for Chemotherapy Using Computed Tomography: An Experimental Study in Pig Models

PurposePercutaneous isolated pancreatic perfusion (PIPP) is performed along with interventional radiology techniques to obtain high drug concentration by occluding the arterial inlet and venous outlet of the pancreas. The experimental study aimed to evaluate the contrast distribution in PIPP under different flow rates with or without anterior mesenteric artery (AMA) occlusion.Materials and MethodsThis study was approved by a local animal experiment ethics committee. Nine pigs were divided into Groups 1, 2, and 3, by infusion rates of 12, 24, and 36 mL/min. Groups 4 and 5 (3 pigs each) and Group 6 (2 pigs) underwent PIPP at the same respective infusion rates with and without AMA occlusion. Computed tomography (CT) arteriography was performed during PIPP with nonionic contrast media. The enhanced volume was calculated by adding the enhanced area in each slice using 1.25-mm axial images. The percent enhanced volume to the whole pancreas (%eV) was used to simulate drug distribution; the result was compared among groups.ResultsWithout AMA occlusion, a larger %eV was obtained with high infusion rates (P = 0.039). The median %eV in Groups 1, 2, and 3 were 57.7, 74.2, and 90.5%, respectively. With AMA occlusion, CT demonstrated duodenal enhancement at an infusion rate of 36 mL/min, and the median %eV in Groups 4, 5, and 6 were 92.8, 95.4, and 98.5%, respectively. A significantly larger %eV was obtained after AMA occlusion (P = 0.031).ConclusionA higher infusion rate or AMA occlusion increases the enhanced volume in PIPP in pig models. Level of evidence: No level of evidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Onyx Embolization for Occlusion of the Proximal Internal Iliac Artery During EVAR in Patients with Unsuitable Landing Zones in the Common Iliac Artery

Background: Twenty percent of the patients with AAA have an aneurysm involving the common iliac arteries. Large common iliac diameter can be treated with an iliac branched device or extension of the stent graft to the external iliac artery with occlusion of the ipsilateral internal iliac artery (IIA) to prevent type 2 endoleaks. This study describes and evaluates a embolization technique using Onyx in conjunction with EVAR in aneurysms with poor landing zones in the common iliac arteries. Methods: Patients with Onyx IIA embolization during EVAR, identified from the hospital operating code database, constitute the study population. Onyx embolization was performed by injection at the IIA origin. Peri- and postoperative complications were collected from the medical records. Thin-sliced CT scan was performed 1 month and 1 year after the procedure. Results: Thirty-six patients with complex iliac anatomy and insufficient landing zones (without sealing possibility for standard stent grafts) were identified out of 243 consecutive EVAR treatments during a 13-year period. In seventeen patients (7%), the IIA was embolized with Onyx. Technical success was obtained in all 17 patients, without adverse event or procedural complication. No complication related to the embolization procedure was noted during follow-up. Conclusions: During EVAR treatment of patients with aneurysm involving the common iliac artery, Onyx embolization of IIA is a feasible option without need of selective catheterization of the IIA orifice, potentially preserving important branches of the IIA and simplifying emergency procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE↗

Characterization of Pulmonary Nodules Based on Features of Margin Sharpness and Texture

Lung cancer is the leading cause of cancer-related deaths in the world, and one of its manifestations occurs with the appearance of pulmonary nodules. The classification of pulmonary nodules may be a complex task to specialists due to temporal, subjective, and qualitative aspects. Therefore, it is important to integrate computational tools to the early pulmonary nodule classification process, since they have the potential to characterize objectively and quantitatively the lesions. In this context, the goal of this work is to perform the classification of pulmonary nodules based on image features of texture and margin sharpness. Computed tomography scans were obtained from a publicly available image database. Texture attributes were extracted from a co-occurrence matrix obtained from the nodule volume. Margin sharpness attributes were extracted from perpendicular lines drawn over the borders on all nodule slices. Feature selection was performed by different algorithms. Classification was performed by several machine learning classifiers and assessed by the area under the receiver operating characteristic curve, sensitivity, specificity, and accuracy. Highest classification performance was obtained by a random forest algorithm with all 48 extracted features. However, a decision tree using only two selected features obtained statistically equivalent performance on sensitivity and specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device

Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7” iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗