Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Empirical laws of particle extraction from single-grid source of bipolar ion-electron flow

The present research is devoted to the problem of extraction grid choice for a single-grid source of bipolar ion-electron flow. The paper contains detailed reference information on ion and electron extraction characteristics of 10 different grids with broad range of parameters: aperture width (0.09-0.6 mm), grid transparency (0.19-0.51), thickness (0.036-0.5 mm), and with different aperture geometry. The grids with square, circular, and slit apertures were made with different technologies: laser cutting, welding, weaving, and electrolytic erosion. The general regularities of the ion and electron extraction from the single-grid source are experimentally researched for the cases of dc and RF extraction grid biasing. A conclusion has been made that the maximum extracted ion current at low ion energy (0-200 eV) does not significantly vary for all the grids and does not exceed half of the primary ion current from plasma multiplied by the optical grid transparency. The low-energy limit of efficient ion extraction has been discovered which cannot be overcome by the aperture narrowing. A conclusion is made that the RF extraction mode is superior for all the researched grids since it is characterized by higher extracted ion current at any acceleration voltage for any grid with much more simple and smooth extraction curves behavior in comparison to the dc case as well as absence of arcing, jumps, and hysteresis of the measured curves at any RF voltages. The unique ability of the RF biased single-grid source of simultaneous ion/electron emission has been studied. The measured maximal attainable ion beam current compensation ratio is always sufficiently higher than 1 and typically varies in the range 2-6. The results obtained in the present paper demonstrate prospective of the single-grid source in space thruster applications and in modern technologies, particularly for ion beam processing of wide bandgap semiconductor devices such as GaN and SiC transistors due to inherent precise beam neutralization.

43 PARTICLE ACCELERATORS↗

The 15 cm mercury ion thruster research 1975

Doubly charged ion current measurements in the beam of a SERT II thruster are shown to introduce corrections which bring its calculated thrust into close agreement with that measured during flight testing. A theoretical model of doubly charged ion production and loss in mercury electron bombardment thrusters is discussed and is shown to yield doubly-to-singly charged ion density ratios that agree with experimental measurements obtained on a 15 cm diameter thruster over a range of operating conditions. Single cusp magnetic field thruster operation is discussed and measured ion beam profiles, performance data, doubly charged ion densities, and discharge plasma characteristics are presented for a range of operating conditions and thruster geometries. Variations in the characteristics of this thruster are compared to those observed in the divergent field thruster and the cusped field thruster is shown to yield flatter ion beam profiles at about the same discharge power and propellant utilization operating point. An ion optics test program is described and the measured effects of grid system dimensions on ion beamlet half angle and diameter are examined. The effectiveness of hollow cathode startup using a thermionically emitting filament within the cathode is examined over a range of mercury flow rates and compared to results obtained with a high voltage tickler startup technique. Results of cathode plasma property measurement tests conducted within the cathode are presented.

Wilbur, P. J.↗

Single-Event Effects in Silicon Carbide Power Devices

This report summarizes the NASA Electronic Parts and Packaging Program Silicon Carbide Power Device Subtask efforts in FY15. Benefits of SiC are described and example NASA Programs and Projects desiring this technology are given. The current status of the radiation tolerance of silicon carbide power devices is given and paths forward in the effort to develop heavy-ion single-event effect hardened devices indicated.

heavy-ion single-event effects↗

Space and phase resolved ion energy and angular distributions in single- and dual-frequency capacitively coupled plasmas

The control of ion energy and angular distributions (IEADs) is critically important for anisotropic etching or deposition in microelectronic fabrication processes. With single frequency capacitively coupled plasmas (CCPs), the narrowing in angle and spread in energy of ions as they cross the sheath are definable functions of frequency, sheath width, and mean free path. With increases in wafer size, single frequency CCPs are finding difficulty in meeting the requirement of simultaneously controlling plasma densities, ion fluxes, and ion energies. Dual-frequency CCPs are being investigated to provide this flexible control. The high frequency (HF) is intended to control the plasma density and ion fluxes, while the ion energies are intended to be controlled by the low frequency (LF). However, recent research has shown that the LF can also influence the magnitude of ion fluxes and that IEADs are determined by both frequencies. Hence, separate control of fluxes and IEADs is complex. In this paper, results from a two-dimensional computational investigation of Ar/O{sub 2} plasma properties in an industrial reactor are discussed. The IEADs are tracked as a function of height above the substrate and phase within the rf cycles from the bulk plasma to the presheath and through the sheath with the goal of providing insights to this complexity. Comparison is made to laser-induced fluorescence experiments. The authors found that the ratios of HF/LF voltage and driving frequency are critical parameters in determining the shape of the IEADs, both during the transit of the ion through the sheath and when ions are incident onto the substrate. To the degree that contributions from the HF can modify plasma density, sheath potential, and sheath thickness, this may provide additional control for the IEADs.

36 MATERIALS SCIENCE↗

Microscopic diamond solid-immersion-lenses fabricated around single defect centers by focused ion beam milling

Recent efforts to define microscopic solid-immersion-lenses (SIL) by focused ion beam milling into diamond substrates that are registered to a preselected single photon emitter are summarized. We show how we determine the position of a single emitter with at least 100 nm lateral and 500 nm axial accuracy, and how the milling procedure is optimized. The characteristics of a single emitter, a Nitrogen Vacancy (NV) center in diamond, are measured before and after producing the SIL and compared with each other. A count rate of 1.0 × 10{sup 6} counts/s is achieved with a [111] oriented NV center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid Extraction Surface Analysis (LESA) Electron-Induced Dissociation and Collision-Induced Dissociation Mass Spectrometry of Small Molecule Drug Compounds

Here, we present liquid extraction surface analysis (LESA) coupled with electron-induced dissociation (EID) mass spectrometry in a Fourier-transform ion cyclotron resonance mass spectrometer for the analysis of small organic pharmaceutical compounds directly from dosed tissue. First, the direct infusion electrospray ionisation EID and collision-induced dissociation (CID) behaviour of erlotinib, moxifloxacin, clozapine and olanzapine standards were compared. EID mass spectra were also compared with experimental or reference electron impact ionisation mass spectra. The results show that (with the exception of erlotinib) EID and CID result in complementary fragment ions. Subsequently, we performed LESA EID MS/MS and LESA CID MS/MS on singly charged ions of moxifloxacin and erlotinib extracted from a thin tissue section of rat kidney from a cassette-dosed animal. Both techniques provided structural information, with the majority of peaks observed for the drug standards also observed for the tissue-extracted species. Overall, these results demonstrate the feasibility of LESA EID MS/MS of drug compounds from dosed tissue and extend the number of molecular structures for which EID behaviour has been determined. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING

In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO{sub 2} substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam process has been used to fabricate bismuth nanowire. The fabricated Bi nanowires were electrically characterised using a semiconductor analyser that showed good ohmic contact to the electrodes. In this paper, the fabrication experiments and the characterisation results for Bi nanowires as small as 50 nm in diameter are presented. Several FIB issues involved in Bi device making and ohmic contacts to Bi nanowires will also be discussed.

36 MATERIALS SCIENCE↗

The NSCL electron beam ion trap for the reacceleration of rare isotopes coming to life: First extraction tests with a high-current electron gun

NSCL is currently constructing the ReA3 reaccelerator, which will accelerate rare isotopes obtained from gas stopping of fast-fragment beams to energies of up to 3 MeV/u for uranium and higher for lighter ions. A high-current charge breeder, based on an electron beam ion trap (EBIT), has been chosen as the first step in the acceleration process, as it has the potential to efficiently produce highly charged ions in a single charge state. These ions are fed into a compact linear accelerator consisting of a radio frequency quadrupole structure and superconducting cavities. The NSCL EBIT has been fully designed with most of the parts constructed. The design concept of the EBIT and results from initial commissioning tests of the electron gun and collector with a temporary 0.4 T magnet are presented.

43 PARTICLE ACCELERATORS↗

Ion-beam induced domain structure in piezoelectric PMN-PT single crystal

We report an investigation of the domain structure in Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}-30%PbTiO{sub 3} single crystals after ion milling. We show that ion milling induces microdomains, typically 0.1-1 {mu}m in size. The induced microdomains disappear after temperature annealing or electric poling, leaving behind nanodomains of a few nanometers in size. We attribute the microdomains to surface stress induced by ion milling. The results demonstrate the general importance of separating sample preparation artifacts from the true domain structure in the study of ferroic materials.

36 MATERIALS SCIENCE↗

Progress towards the development of a realistic electron cyclotron resonance ion source extraction model

In this paper, an ongoing effort to provide a simulation and design tool for electron cyclotron resonance ion source extraction and low energy beam transport is described and benchmarked against experimental results. Utilizing the particle-in-cell code WARP, a set of scripts has been developed: A semiempirical method of generating initial conditions, a 2D-3D hybrid method of plasma extraction and a simple beam transport deck. Measured emittances and beam profiles of uranium and helium beams are shown and the influence of the sextupole part of the plasma confinement field is investigated. The results are compared to simulations carried out using the methods described above. The results show that the simulation model (with some additional refinements) represents highly charged, well-confined ions well, but that the model is less applicable for less confined, singly charged ions.

43 PARTICLE ACCELERATORS↗

Simulation-based Study of Single-Event Burnout in 4H-SiC High-Voltage Vertical Superjunction DMOSFET: Physical Failure Mechanism and Robustness vs. Performance Tradeoffs

We explore and elucidate physical failure mechanisms in a 4H-SiC, high voltage, superjunction (SJ) vertical DMOSFET from a single heavy ion strike using three-dimensional electro-thermal transient simulations. The single-event burnout (SEB) failure is thermal runaway from second breakdown, initiated by impact ionization and terminated with mesoplasma formation, at the center of the P-pillar/N+ substrate interface. We also demonstrate that the SEB performance of this SiC SJ DMOSFET is insensitive to the pillar width but sensitive to the strike location with ion strike at the P-pillar causing SEB at a lower blocking voltage than at the N-pillar. Compared to commercially available 1.2 kV blocking-rated non-SJ DMOSFETs, which have been demonstrated to survive SEB up to 525 V, the SJ DMOSFET increases SEB survival threshold voltage (VSEB) by a factor of 2.2, making it close to 1200 V, while the on-resistance is increased by only 11%. Using our recently developed figure of merit (FoM), which considers the trade-off between VSEB and on-state performance, we find that the SiC SJ DMOSFET achieves a FoM that is 14 times better, making it superior to conventional 1.2 kV SiC DMOSFETs for long-term radiation-tolerant operation in space applications.

Silicon Carbide↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Kinetics of color center formation in silica irradiated with swift heavy ions: Thresholding and formation efficiency

We have determined the cross-section {sigma} for color center generation under single Br ion impacts on amorphous SiO{sub 2}. The evolution of the cross-sections, {sigma}(E) and {sigma}(S{sub e}), show an initial flat stage that we associate to atomic collision mechanisms. Above a certain threshold value (S{sub e} > 2 keV/nm), roughly coinciding with that reported for the onset of macroscopic disorder (compaction), {sigma} shows a marked increase due to electronic processes. In this regime, a energetic cost of around 7.5 keV is necessary to create a non bridging oxygen hole center-E Prime (NBOHC/E Prime ) pair, whatever the input energy. The data appear consistent with a non-radiative decay of self-trapped excitons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Mass Ion Detection with Charge Detector Coupled to Rectilinear Ion Trap Mass Spectrometer

Conventional linear ion trap mass analyzers (LIT-MS) provide high ion capacity and show their MS{sup n} ability; however, the detection of high mass ions is still challenging because LIT-MS with secondary electron detectors (SED) cannot detect high mass ions. To detect high mass ions, we coupled a charge detector (CD) to a rectilinear ion trap mass spectrometer (RIT-MS). Immunoglobulin G ions (m/z ~150,000) are measured successfully with controlled ion kinetic energy. In addition, when mass-to-charge (m/z) ratios of singly charged ions exceed 10 kTh, the detection efficiency of CD is found to be greater than that of SED. The CD can be coupled to LIT-MS to extend the detection mass range and provide the potential to perform MS{sup n} of high mass ions inside the ion trap. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled effects of electronic and nuclear energy deposition on damage accumulation in ion-irradiated SiC

Coupling between electronic and nuclear energy dissipation in ion-irradiated, single crystal 4H-SiC has been investigated using Si, Ti, and Ni ions over a range of energies at 300 K, and irradiation damage accumulation is characterized using Rutherford backscattering spectroscopy in channeling geometry. The damage production rate from nuclear energy loss (S n ) is observed to decrease with increasing electronic energy loss (S e ) of the incident ions. A dynamic threshold (S e,th ) in electronic energy loss is determined for each ion species, which defines two regions: i) S e > S e,th , where electronic energy dissipation fully suppresses damage production due to nuclear energy loss along incident ion paths, and ii) S e < S e,th , where simultaneous damage recovery due to Se competes with damage production processes. Here, the electronic energy loss threshold (S e,th ) increases sublinearly with incident ion atomic number. Here, the assessment of S e,th and how it affects damage accumulation is important to advance the understanding of complex processes occurring under ion-solid interactions, as well as in the design of functional materials for opto-electronics and novel structural materials and devices tolerant to harsh thermal and radiation environments.

36 MATERIALS SCIENCE↗

Magnetized plasma sheath with two species of positive ions

The effects of the magnitude and direction of an oblique magnetic field and the effect of the ion densities ratio on a plasma sheath of electrons and two species of positive ions are investigated by using a three-fluid hydrodynamics model. These ions have different masses but the same ionization ratio (Z=1). It is shown that the density distribution and velocity of the lighter and heavier ion species begin to fluctuate under the action of the electrostatic and Lorentz forces when the ratio of electron Debye length to lighter ion species Larmor radius becomes greater than 1 and 3, respectively. Also, it is found that the velocity fluctuations of the lighter ion species are much higher than those of the heavier ion species. Furthermore, the obtained results due to the presence of the second ion (the heavier ion) are compared to the reported results of the magnetized plasma sheath including single positive ion species. In the presence of the second ion, it is shown that the velocity and density distribution of the lighter ion species in the magnetized plasma sheath decreases and increases, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Intensity, Pulsed, D-D Neutron Generator

Single ion-beam RF-plasma neutron generators are presented as a laboratory source of intense neutrons. The continuous and pulsed operations of such a neutron generator using the deuterium-deuterium fusion reaction are reported. The neutron beam can be pulsed by switching the RF plasma and/or a gate electrode. These generators are actively vacuum pumped so that a continuous supply of deuterium gas is present for the production of ions and neutrons. This contributes to the generator's long life. These single-beam generators are capable of producing up to 10{sup 10} n/s. Previously, Adelphi and LBNL have demonstrated these generators' applications in fast neutron radiography, Prompt Gamma Neutron Activation Analysis (PGNAA) and Neutron Activation Analysis (NAA). Together with an inexpensive compact moderator, these high-output neutron generators extend useful applications to home laboratory operations.

43 PARTICLE ACCELERATORS↗

Investigating the performance of an ion luminescence probe as a multichannel fast-ion energy spectrometer using pulse height analysis

We investigate the capability of a fast-ion luminescent probe to operate as a pulse height ion energy analyzer. An existing high sensitivity system has been reconfigured as a single channel ion detector with an amplifier to give a bandwidth comparable to the phosphor response time. A digital pulse processing method has been developed to determine pulse heights from the detector signal so as to obtain time-resolved information on the ion energy distribution of the plasma ions lost to the wall of the TJ-II stellarator. Finally, the potential of this approach for magnetic confined fusion plasmas is evaluated by studying representative TJ-II discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗