Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

A new detector for mass spectrometry: Direct detection of low energy ions using a multi-pixel photon counter

A new type of ion detector for mass spectrometry and general detection of low energy ions is presented. The detector consists of a scintillator optically coupled to a single-photon avalanche photodiode (SPAD) array. A prototype sensor has been constructed from a LYSO (Lu{sub 1.8}Y{sub 0.2}SiO{sub 5}(Ce)) scintillator crystal coupled to a commercial SPAD array detector. As proof of concept, the detector is used to record the time-of-flight mass spectra of butanone and carbon disulphide, and the dependence of detection sensitivity on the ion kinetic energy is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of Kaonetics Devices at BNL

The goal of these measurements was to evaluate whether there is evidence of emission of X-rays, gamma-rays, and neutrons by devices developed by Kaonetics Technologies, Inc. during their operation. The measurements were carried out with two Kaonetics’s modules, called EMR Gen 1 ("Device 1") and EMR Gen 2 ("Device 2"). Two types of detectors were set up in a remote building to avoid potential interference from other labs. For X- and gamma-rays we used a large-volume, high-sensitivity NaI(Tl) Bicron scintillation detector and a multichannel analyzer (MCA). For neutrons, we employed a ~ ½ liter 3He-filled proportional counter. The measurements were taken under normal background-dominated conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt Neutron Decay Constant from Feynman Variance Fitting

The use of fast-response liquid scintillators for passive measurements with highly enriched uranium (HEU) castings provides information on the timescale of the fission chain multiplication process for HEU. Thus, these detectors produce time responses characteristic of the HEU and not the moderator around 3He counters. Up to five HEU castings were assembled, and the passive time coincidence measurements performed. The prompt neutron decay constants inferred from the Feynman variance data with the arrays of large liquid scintillators are compared with decay constants obtained from previously presented Feynman variance data collected in active interrogation measurements with these same HEU castings. The active measurements used plastic scintillation detectors adjacent to the castings to eliminate time-of-flight effects and showed that the prompt neutron decay constant is clearly not exponential. However, time-of-flight effects in the passive measurements result in exponential behavior and allow the Feynman variance data to be fit with the well-known point kinetics analytical formula. The characterization of the prompt neutron decay constant is investigated by comparing the results of the passive and active measurement data.

36 MATERIALS SCIENCE↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of radiation damage to the CMS Hadronic Endcap Calorimeter and investigation into new physics using multi-boson measurements

This document is the final report for the U.S. D.O.E. Grant No. DE-SC0014088, which covers the period from May 15, 2015 to March 31, 2016. The funded research covered the study of multi-boson final states, culminated in the measurement of the W ± γγ and, for the first time at an hadronic collider, of the Zγγ production cross sections. These processes, among the rarest multi-boson final states measurable by LHC experiments, allow us to investigate the possibility of new physics in a model-independent way, by looking for anomalies in the standard model couplings among electroweak bosons. In particular, these 3-boson final states access quartic gauge couplings; the W ± γγ analysis performed as a part of this proposal sets limits on anomalies in the WWγγ quartic gauge coupling. The award also covered R&D activities to define a radiation-tolerant material to be used in the incoming upgrade of the CMS hadronic endcap calorimeter. In particular, the usage of a liquid-scintillator-based detector was investigated. The research work performed in this direction has been collected in a paper recently submitted for publication in the Journal of Instrumentation (JINST).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antennas and Propagation; Proceedings of the International Conference, 8th, Heriot-Watt Univeristy, Edinburgh, UK, Mar. 30 - Apr. 2, 1993. Vols. 1 & 2

Conference papers from sessions on the following topics are presented: satellite antennas; modal analysis of transmission line structures; fading and scintillation; microcellular; numerical analysis; Olympus; indoor mobile; mechanical aspects of satellite antennas; flat plate and printed antennas; fade counter measures; electromagnetic theory; feeds for satellites; antennas for personal communications; frequency selected surfaces; remote sensing; active patch antennas; antenna measurements; clear air/trans horizon; high frequency system and noise; rain attenuation and rain scatter; and high frequency direction finding.

Source record↗

A Hybrid Gas Detector/Phoswich for Hard X-ray Astronomy

A hybrid detector, which combines an optical avalanche chamber with a phoswich, is currently under development. The optical avalanche chamber - a proportional counter designed to give large quantities of light photons during charge multiplication, mounts on the front of the scintillator and gives response at low energies, while the solid scintillator takes over at energies where the gas becomes transparent (greater than 90 keV). Both sections of the hybrid will be read out by a common set of photomultipliers under the phoswich. The addition of the gas section to the phoswich improves the energy resolution of the instrument by a factor of 2.5 at 25 keV and the spatial resolution by a factor of 10 at the same energy. The net result is an instrument with broad band coverage and high sensitivity which will be used for coded aperture imaging on long duration balloon flights.

Ramsey, B. D.↗

PLATEAUING COSMIC RAY DETECTORS TO ACHIEVE OPTIMUM OPERATING VOLTAGE

Through QuarkNet, students across the country have access to cosmic ray detectors in their high school classrooms. These detectors operate using a scintillator material and a photomultiplier tube (PMT). A data acquisition (DAQ) board counts cosmic ray hits from the counters. Through an online e-Lab, students can analyze and share their data. In order to collect viable data, the PMTs should operate at their plateau voltages. In these plateau ranges, the number of counts per minute remains relatively constant with small changes in PMT voltage. We sought to plateau the counters in the test array and to clarify the plateauing procedure itself. In order to most effectively plateau the counters, the counters should be stacked and programmed to record the number of coincident hits as well as their singles rates. We also changed the threshold value that a signal must exceed in order to record a hit and replateaued the counters. For counter 1, counter 2, and counter 3, we found plateau voltages around 1V. The singles rate plateau was very small, while the coincidence plateau was very long. The plateau voltages corresponded to a singles rate of 700–850 counts per minute. We found very little effect of changing the threshold voltages. Our chosen plateau voltages produced good performance studies on the e-Lab. Keeping in mind the nature of the experiments conducted by the high school students, we recommend a streamlined plateauing process. Because changing the threshold did not drastically affect the plateau voltage or the performance study, students should choose a threshold value, construct plateau graphs, and analyze their data using a performance study. Even if the counters operate slightly off their plateau voltage, they should deliver good performance studies and return reliable results.

Knoff, E N↗

SU-F-J-182: Investigation of Systems for Improved Accuracy in Clinical Y-90 Percent Delivered Calculations

Purpose: Y-90 Selective Internal Radiation Therapy (SIRT) is used to treat liver tumors, and by nature has variability in the percent of the intended dose that is actually delivered. To determine the quality of the administration, pre and post activity measurements are taken, and used to infer percent delivered. Vendor specifications indicate the use of an ion chamber to take these measurements. In our work, we investigated the accuracy of ion chambers, and compared them to other detector systems. Methods: We have built phantoms, phantom holders, and protocols, which allow us to measure our Y90 doses with varying apparatuses: a dose calibrator, a Geiger-counter, an ion chamber, a crystal based thyroid probe, and a gamma camera. We have set up a system that has enabled us to gather data by measuring clinical Y90 doses as they are used in the clinic using all of the instrumental methods. Five initial doses (25 measurements/acquisitions) have been taken at the time of this abstract submission. Results: Our initial results show that measurements acquired using scintillation based detectors (thyroid probe and gamma camera) correlate better with the gold standard (i.e. the dose calibrator). Pearson correlations between the dose calibrator measurements and the GM counter, Ion chamber, thyroid probe, and gamma camera were found to be 0.88, 0.83, 0.98, 0.99, respectively. More acquisitions and analysis are planned to determine the precision of the systems, as well as optimal energy window settings. Conclusion: It is likely that current standard practice can be improved using scintillation crystal based detectors. Such systems are more sensitive, can integrate signal, and can use energy discrimination. Furthermore, phantoms can be built to integrate with probe and gamma camera systems that are robust and provide reproducibility. Future work will include expanded acquisition and analysis.

60 APPLIED LIFE SCIENCES↗

Methodological Issues of Gamma-Ray and Neutrino Searches at the Yakutsk Array

The method used to perform searches for extensive air showers (EAS) generated by neutral particles, such as high-energy gamma rays and astrophysical neutrinos, and the results of such searches are presented. A comprehensive analysis of relevant data, including those on EAS electrons, muons, and Cherenkov light and their time responses in scintillation and Cherenkov detectors, is performed for this purpose. An upper limit on the gamma-ray flux at the energies of 3 × 10{sup 18}, 10{sup 19}, and 3 × 10{sup 19} eV is set. A multivariate analysis of EAS properties of neutrino-induced air showers does not reveal neutrino-induced showers.

79 ASTRONOMY AND ASTROPHYSICS↗

A Measurement of the Scintillation Light Yield in CD4 Using a Photosensitive GEM Detector

The absolute photon yield of scintillation light produced by highly ionizing particles in pure CF{sub 4} has been measured using a photosensitive Gas Electron Multiplier (GEM) detector. The detector consists of two standard GEMs and a CsI coated GEM which acts as a photocathode that is sensitive to the 160 nm scintillation light produced in CF{sub 4}. The light yield was determined in terms of the number of scintillation photons emitted into a 4{pi} solid angle produced per MeV of energy deposited in the gas by a 5.5 MeV alpha particle and found to be 314 {+-} 15 photons per MeV. The quantum yield was determined using a fitting method to determine the number of photoelectrons from the measured pulse height distribution, and by an independent method using the measured gain of the GEM detector. The effect of scintillation light in CF{sub 4} on the performance of Cherenkov detectors, such as the PHENIX Hadron Blind Detector (HBD) at RHIC, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ground calibration and in-flight commissioning of the Gamma-Ray and Neutron Spectrometer (GRNS) for NASA’s Psyche mission

NASA's Psyche spacecraft is currently enroute to the asteroid 16 Psyche, where it will perform an orbital investigation focused on determining the nature of the asteroid. A key part of this investigation is measurements of elemental composition to determine if the asteroid is rich in iron-nickel metal. To that end, the Psyche spacecraft payload includes a Gamma-Ray and Neutron Spectrometer (GRNS). GRNS is composed of two subsystems; a Gamma-Ray Spectrometer (GRS) with a high-purity germanium γ-ray sensor surrounded by a borated plastic scintillator Anti-Coincidence Shield (ACS), and a Neutron Spectrometer (NS) with three 3 He-filled gas proportional counters that are sensitive to different neutron energy regimes. We describe results from the pre-launch calibration campaign, along with early in-flight results from post-launch instrument commissioning. The information detailed here is focused on providing future users of GRNS data with the information needed to properly interpret the observations from the instrument.

Peplowski, Patrick N. [Johns Hopkins Univ., Baltim↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

X-ray observations of AM Herculis from OSO-8

The white dwarf binary system AM Herculis (2A1815+500) was observed in X-rays at both low energies (E less 10 keV) and higher energies. The exact shape of the spectrum, particularly at the higher energies, has yet to be determined. Results from the high energy scintillation spectrometer on OSO-8 are presented. These are combined with results published elsewhere obtained concurrently with the proportional counter on the same satellite, thereby giving for the first time coincident observations of AM Her over the range 2 to 250 keV.

Coe, M. J.↗

Imaging vs. non-imaging in long range neutron detection scenarios.

Standoff neutron detection technology has advanced in recent years, primarily for counterterrorism applications. Sandia National Laboratories has developed the Neutron Scatter Camera -- a fast neutron imaging system using liquid scintillator with potential applications in long range neutron detection. This talk will explore the pros, cons and practical uses of the Neutron Scatter Camera versus more traditional neutron detectors such as He-3 proportional counters. Several applications for neutron detection and imaging will be explored. We will perform predictive calculations of the response of the Neutron Scatter Camera and traditional He-3 detectors. The applications range from counterterrorism to arms control to safeguards. We will discuss future evolution of the scatter camera to enhance long range detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the Low Granularity Pair Spectrometer counters in Hall D at JLab

The pair spectrometer in the photon beam line of Hall D at JLab is designed to monitor the stability of photon flux and the relative tagging efficiency of the photon tagger via a well known electron-positron pair production measurement. The pair spectrometer consists of a thin foil converter, a dipole magnet, and two identical left and right arm detector packages. Each detector package covers the electron or position energy from 3 GeV to 6.25 GeV. It consists of a front detector array for fine position resolution and rear scintillating hodoscopes to provide fast timing to form the pair production trigger. This presentation will focus on the construction and testing of the Low-Granularity Pair Spectrometer counters.

Dzbenski, Nathan↗