Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Aerosol Engineering Facility 2021-22 summary sheet [Slides]

The Aerosol Engineering Facility solves problems that involve radioactive particulates, including HEPA air filters, storage containers, exhaust stacks, and continuous air monitors. Other work includes silica dust sampling, bioaerosols, and insecticide sprays. Aerosol technology science describes the behavior of microscopic and nano-sized particles, in both molecular and continuum gas flow regimes.

36 MATERIALS SCIENCE↗

Illustration of Neutronic Decoupling in Fresh Fuel Storage Environments [Slides]

Operations beyond static storage of fuel assemblies occur in SFPs (moving around the pool, inspection, etc.). These assemblies are assumed suitably distanced at 30 cm. When assemblies are separated by enough water, the neutrons from one cannot cause fission in another, which results in neutronic decoupling. This assumption was investigated for PWR and BWR assemblies as part of ORNL-TM/2021/2330.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2021

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2021. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2021 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Methane Monitoring Platform Extension, Volume I: Final Technical Report

The IMMPE project, DE-FE0032284, was to enhance methane monitoring technologies and their applications across various natural gas asset classes. The scope included deploying advanced methane detection and monitoring technologies to identify and mitigate fugitive methane emissions, measuring emission rates, and assessing impacts. The findings included the successful mitigation of identified emissions and quantification of emission rates. A key outcome was the development of a comprehensive template and summary of recommendations for methane emissions monitoring, which is replicable for both upstream and downstream applications. Furthermore, the project emphasized the importance of education by providing training opportunities for technicians and regulators, thereby fostering awareness and promoting the adoption of cost-effective methane emissions monitoring and management techniques.

02 PETROLEUM↗

Hidden Processes During Seasonal Isolation of a High-Altitude Watershed

Biogeochemical processes capable of altering global carbon systems occur frequently in Earth’s Critical Zone–the area spanning from vegetation canopy to saturated bedrock–yet many of these phenomena are difficult to detect. Observation of these processes is limited by the seasonal inaccessibility of remote ecosystems, such as those in mountainous, snow- and ice-dominated areas. This isolation leads to a distinct gap in biogeochemical knowledge that ultimately affects the accuracy and confidence with which these ecosystems can be computationally modeled for the purpose of projecting change under different climate scenarios. To examine a high-altitude, headwater ecosystem’s role in methanogenesis, sulfate reduction, and groundwater-surface water exchange, water samples were continuously collected from the river and hyporheic zones (HZ) during winter isolation in the East River (ER), CO watershed. Measurements of continuously collected ER surface water revealed up to 50 μM levels of dissolved methane in July through September, while samples from 12 cm deep in the hyporheic zone at the same location showed a spring to early summer peak in methane with a strong biogenic signature (<65 μM, δ13C-CH4, -60.76‰) before declining. Continuously collected δ 18 O-H 2 O and δ 2 H-H 2 O isotopes from the water column exhibited similar patterns to discrete measurements, while samples 12 cm deep in the hyporheic zone experienced distinct fluctuations in δ 18 O-H 2 O, alluding to significant groundwater interactions. Continuously collected microbial communities in the river in the late fall and early winter revealed diverse populations that reflect the taxonomic composition of ecologically similar river systems, including taxa indicative of methane cycling in this system. These measurements captured several biogeochemical components of the high-altitude watershed in response to seasonality, strengthening our understanding of these systems during the winter months.

54 ENVIRONMENTAL SCIENCES↗

Fog particle concentrations

ngVIPS metadata and caveats: Column 1: Time, seconds after midnight UTC of beginning of time period. (60 sec values) Column 2: Relative concentration. Notes: Concentration values are observed values and assume ~4.0 m/s wind speed. (#/cm^3) Caveats: Observed particles with a very few exceptions were on the order of a few pixels (less than 10 microns). The size differential was insufficient to determine a particle size distribution. As the temperatures were relatively warm (and it can be 10C warmer inside the instrument) it is anticipated that some solid ice particles could have melted and some smaller liquid drops could have evaporated. A cyclic nature to the high resolution data was observed and determined to be caused by a focus issue. Each 60 second period included ~25 images. Particles are collected on a glass disk, but the disk isn't perfectly centered causing small particles to be slightly out of focus during part of the rotation. For that reason, we chose to report the average of the five highest values in a time period rather the average of all values. Higher resolution can be made available upon request, but a conversation with the PI would be important to fully understand the planned usage and if the higher resolution data were to be useful for the task. Please contact instrument PI, Carl Schmitt (naturalsystemsresearch@gmail.com) with any questions about these data.

54 ENVIRONMENTAL SCIENCES↗

ExINP-ENA Ice-Nucleating Particle Concentrations - CRAFT

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) observatory on Graciosa Island, Azores (39.0916&deg; N, 28.0257&deg; W). Our INP data were generated using a combination of online instruments, the Portable Ice Nucleation Experiment chamber (PINE), and an offline assay instrument, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT), for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores).

47-mm Nuclepore filter sampler, West Texas Cryogen↗

Making and Inspecting Large Wire Grids

Old techniques refined and combined to make new polarizers. Equipment and procedures developed for fabrication and inspection of large, precisely-spaced, flat grids of wire. Technology includes refinements and combinations of established techniques for winding grids of electron tubes and ruling optical gratings and incorporates recent developments in electronic control and laser/electronic-based metrology. Wire wrapped on frame half translated under automatic control to achieve desired space between turns. Frame halves put together, and excess wire cut away, leaving finished grid mounted in frame. Useful as polarizers and beam splitters for electromagnetic radiation in overlapping ranges of long infrared and microwaves.

Magner, Thomas J.↗

Optical alignments of the Cosmic Background Explorer (COBE) observatory

The angular alignments and stabilities of multiple components in a single coordinate system were determined using various alignment tooling techniques. These techniques use autocollimation measurements with a first order theodolite and transformation of coordinates to determine the relative alignment between various components with respect to a common set of COBE spacecraft coordinate axes. Optical-mechanical alignment techniques were also used to integrate the flight COBE observatory attitude control system module that consists of gyros, reaction wheels, and a momentum wheel. Particular attention is given to the techniques for alignments and stabilities of the earth scanners, sun sensors, far IR absolute spectrophotometer, Diffuse Infrared Background Experiment, and differential microwave radiometer antenna horn boresights.

Sampler, Henry P.↗

Photogrammetrically Measured Distortions of Composite Structure Microwave Reflectors at Approximately 90 K

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a fall 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (better than 0.3 deg.) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back composite Gregorian telescopes supported on a composite truss structure to focus the microwave signals into 10 differential microwave receivers. Proper position and shape of the telescope reflectors at the operating temperature of approximately 90 K is a critical element to ensuring mission success. We describe the methods and analysis used to validate the in-flight position and shape predictions for the reflectors based on photogrammetric (PG) metrology data taken under vacuum with the reflectors at approximately 90 K. Contour maps showing reflector distortion analytical extrapolations were generated. The resulting reflector distortion data are shown to be crucial to the analytical assessment of the MAP instrument's microwave system in-flight performance.

Mule, Peter↗

Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a fall 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (approximately 0.2 degree) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformation predictions to be measured were on the order of +/- 0.030 inches (+/- 0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. The most troublesome limitation was the inability to send personnel into the chamber to perform the measurements during the test due to vacuum and the temperature extremes. The photogrammetry (PG) system was chosen to perform the measurements since it is a non- contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The measurements met the desired requirements, for the metal structures enabling the desired distortions to be measured resolving deformations an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

Hill, Michael D.↗

Photogrammetrically Measured Distortions of Composite Structure Microwave Reflectors at -90K

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a late 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (better than 0.3 deg. at 90 GHz.) map of the Cosmic Microwave Background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back composite Gregorian telescopes supported on a composite truss structure to focus the microwave signals into 10 differential microwave receivers. Proper position and shape of the telescope reflectors at the operating temperature of -90 K is a critical element to ensure mission success. We describe the methods and analysis used to validate the in-flight position and shape predictions for the reflectors based on photogrammetric metrology data taken under vacuum with the reflectors at -90 K. Contour maps showing reflector distortion were generated. The resulting reflector distortion data are shown to be crucial to the analytical assessment of the MAP instrument's microwave system in-flight performance.

Mule, Peter↗

Alignment Measurements of the Microwave Anisotropy Probe (MAP) Instrument in a Thermal/Vacuum Chamber Using Photogrammetry

The Microwave Anisotropy Probe (MAP) Observatory, scheduled for a late 2000 launch, is designed to measure temperature fluctuations (anisotropy) and produce a high sensitivity and high spatial resolution (< 0.3 deg at 90 GHz.) map of the cosmic microwave background (CMB) radiation over the entire sky between 22 and 90 GHz. MAP utilizes back-to-back Gregorian telescopes to focus the microwave signals into 10 differential microwave receivers, via 20 feed horns. Proper alignment of the telescope reflectors and the feed horns at the operating temperature of 90 K is a critical element to ensure mission success. We describe the hardware and methods used to validate the displacement/deformation predictions of the reflectors and the microwave feed horns during thermal/vacuum testing of the reflectors and the microwave instrument. The smallest deformations to be resolved by the measurement system were on the order of +/- 0.030 inches (0.762 mm). Performance of these alignment measurements inside a thermal/vacuum chamber with conventional alignment equipment posed several limitations. A photogrammetry (PG) system was chosen to perform the measurements since it is a non-contact measurement system, the measurements can be made relatively quickly and accurately, and the photogrammetric camera can be operated remotely. The hardware and methods developed to perform the MAP alignment measurements using PG proved to be highly successful. The PG measurements met the desired requirements, enabling the desired deformations to be measured and even resolved to an order of magnitude smaller than the imposed requirements. Viable data were provided to the MAP Project for a full analysis of the on-orbit performance of the Instrument's microwave system.

Hill, Michael D.↗

An Overview of Integration and Test of the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element (OTE) and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The SIs and Guider are mounted to a composite metering structure with outer dimensions of 2.1x2.2x1.9m. The SI and Guider units are integrated to the ISIM structure and optically tested at NASA/Goddard Space Flight Center as an instrument suite using a high-fidelity, cryogenic JWST telescope simulator that features a 1.5m diameter powered mirror. The SIs are integrated and aligned to the structure under ambient, clean room conditions. SI performance, including focus, pupil shear and wavefront error, is evaluated at the operating temperature. We present an overview of the ISIM integration within the context of Observatory-level construction. We describe the integration and verification plan for the ISIM element, including an overview of our incremental verification approach, ambient mechanical integration and test plans and optical alignment and cryogenic test plans. We describe key ground support equipment and facilities.

Drury, Michael↗

The James Webb Space Telescope

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISIM optical metering structure is a roughly 2.2x1.7x2.2mY, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISM structure must meet its requirements at the approx.40K cryogenic operating temperature. The SIs are aligned to the structure s coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified.

Nowak, Maria↗