Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE PREPARATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Exploring the interfacial structure and crystallinity for direct growth of Mn 3 Sn(0001) on sapphire (0001) by molecular beam epitaxy

The Kagome antiferromagnet Mn 3 Sn has garnered a lot of attention due to the presence of interesting properties such as anomalous Hall effects and Nernst effects. Until now, few papers have been reported to grow using molecular beam epitaxy with a buffer layer or on other substrates. In this paper, we discuss the synthesis of crystalline Mn 3 Sn layers, prepared on Al 2 O 3 (0001) without a buffer layer using molecular beam epitaxy. The growth is monitored in-situ using reflection high energy electron diffraction and measured ex-situ using X-ray diffraction, Rutherford back-scattering, and cross-sectional scanning transmission electron microscopy. The samples were deposited at 524 ± 5 °C, with an Mn: Sn atomic flux ratio of 3.2:1 for 90 minutes. Orientation relationships between the Mn 3 Sn films and the sapphire substrates are determined from in-plane and out-of-plane measurements. Our analysis indicates that the resulting film is predominantly c−plane oriented. Lastly, the samples prepared in this way were found to be discontiguous, showing a 3-dimensional morphology. According to first-principles calculations, the Mn 3 Sn exhibits a displaced Kagome structure in the very first stages of growth, for 2ML and 4ML growth on Al 2 O 3 (0001). This result is corroborated by calculating the surface formation energies and explains the observed RHEED patterns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Spatial top-down proteomics for the functional characterization of human kidney

Background: The Human Proteome Project has credibly detected nearly 93% of the roughly 20,000 proteins which are predicted by the human genome. However, the proteome is enigmatic, where alterations in amino acid sequences from polymorphisms and alternative splicing, errors in translation, and post-translational modifications result in a proteome depth estimated at several million unique proteoforms. Recently mass spectrometry has been demonstrated in several landmark efforts mapping the human proteoform landscape in bulk analyses. Herein, we developed an integrated workflow for characterizing proteoforms from human tissue in a spatially resolved manner by coupling laser capture microdissection, nanoliter-scale sample preparation, and mass spectrometry imaging. Results: Using healthy human kidney sections as the case study, we focused our analyses on the major functional tissue units including glomeruli, tubules, and medullary rays. After laser capture microdissection, these isolated functional tissue units were processed with microPOTS (microdroplet processing in one-pot for trace samples) for sensitive top-down proteomics measurement. This provided a quantitative database of 616 proteoforms that was further leveraged as a library for mass spectrometry imaging with near-cellular spatial resolution over the entire section. Notably, several mitochondrial proteoforms were found to be differentially abundant between glomeruli and convoluted tubules, and further spatial contextualization was provided by mass spectrometry imaging confirming unique differences identified by microPOTS, and further expanding the field-of-view for unique distributions such as enhanced abundance of a truncated form (1-74) of ubiquitin within cortical regions. Conclusions: We developed an integrated workflow to directly identify proteoforms and reveal their spatial distributions. Where of the 20 differentially abundant proteoforms identified as discriminate between tubules and glomeruli by microPOTS, the vast majority of tubular proteoforms were of mitochondrial origin (8 of 10) where discriminate proteoforms in glomeruli were primarily hemoglobin subunits (9 of 10). These trends were also identified within ion images demonstrating spatially resolved characterization of proteoforms that has the potential to reshape discovery-based proteomics because the proteoforms are the ultimate effector of cellular functions. Applications of this technology have the potential to unravel etiology and pathophysiology of disease states, informing on biologically active proteoforms, which remodel the proteomic landscape in chronic and acute disorders.

59 BASIC BIOLOGICAL SCIENCES↗

Establishing In-House Titration Capabilities: Part I. Hydroxyl Group Titration through Acetic Anhydride Acetylation

This lessons learned document provides a detailed analysis of the hydroxy termination titration methods employed for determining hydroxyl group content in various chemical samples. The primary focus is on the evaluation of techniques such as ASTM E222 and their practical applications in laboratory settings. Through examination of method selection, sample preparation, and titration execution, key insights have been identified that enhance the accuracy and reliability of results. Notable findings include the advantages of using pressure bottle methods for improved heating uniformity and reduced solvent loss, as well as the challenges associated with endpoint detection in dark-colored solutions. Recommendations for alternative sampling and titration techniques are proposed to address these challenges. This document serves as a valuable resource for enhancing the effectiveness and efficiency of hydroxy termination titration methods in chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples - FY17 Year End Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s Network of Analytical Laboratories (IAEA NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA and UTEVA resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. The newly designed prepFAST-SR has had several upgrades compared with the original prepFAST-MC2. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples – Final Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc. (ESI), the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA® and UTEVA® resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. Based on the initial experience at ORNL with the prepFAST-MC2, a second-generation model, the prepFAST-SR, was built by ESI. The newly designed prepFAST-SR has several upgrades compared with the original prepFAST-MC2. The upgrades largely addressed issues with the reliability of unpacking the Eichrom columns and with ventilation to ensure adequate removal of acid vapors. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL. Separations of mixed uranium and plutonium samples containing certified reference materials were analyzed by multi-collector inductively coupled plasma mass spectrometry and yielded good results. Current efforts have demonstrated a wider applicability of the prepFAST system. Near-quantitative removal of metal interferences was achieved with the system in both uranium and plutonium separated fractions. Successful system validation was completed with several archived samples. Isotopic results from archived samples and certified reference materials were well within data quality limits for the IAEA NWAL. Additional COTS equipment has been evaluated for its potential to aid the prepFAST-SR system in reducing the time allotments and cleanroom infrastructure requirements for accurate separations. Overall, these efforts help ensure continued efficient and effective operation of the NWAL. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced cost by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunable Few-Layer van der Waals Crystals and Heterostructures as Emerging Energy and Quantum Materials (Final Technical Report)

2D and layered (van der Waals) semiconductors offer extraordinary opportunities for manipulating optically excited charge carriers, many-body excitations, and non-charge based quantum numbers. To date, research has focused on a limited group of materials, mostly transition metal dichalcogenides in the monolayer limit. Other van der Waals semiconductors, and especially few-layer to multilayer crystals and their heterostructures, carry large potential for the discovery of phenomena of interest for future energy and information technologies. But they remain largely unexplored, often due to a lack of access to high-quality materials and approaches for measuring their properties at the relevant scales. The goal of this project was to develop an EPSCoR-State/National Laboratory Partnership that addresses the challenges of preparing high-quality van der Waals semiconductors and of probing their structure, composition, and especially their optoelectronic and photonic properties, near the atomic scale using electron microscopy techniques. A central component of the project was the development of advanced methods for electron microscopy and electron-excited spectroscopy, taking advantage of unique samples as well as leading capabilities and expertise at the partner institutions. Efforts to advance leading-edge techniques was supported by ancillary developments, such as precision sample preparation for electron microscopy/spectroscopy, coordinated chemical imaging, and analytical electron microscopy. Experiments in materials synthesis and technique development were closely linked to theory and computation. The results obtained under this project yielded multifaceted benefits to the involved partners and their institutions, DOE-BES, the wider scientific community, and society at large, particularly in the State of Nebraska through dividends from knowledge and human capital generated under the project.

36 MATERIALS SCIENCE↗

Rapid, Untargeted Chemical Profiling of Single Cells in Their Native Environment

We report a method that enables untargeted, high throughput, and quantitative mass spectrometric analysis of single cells from cell suspension without needing additional sample preparation procedures (e.g., molecular tagging) through the combination of single-cell printer technology and liquid vortex capture–mass spectrometry (SCP-LVC-MS). The operating principle behind the SCP-LVC-MS technology is single cell isolation via small droplet piezoelectric ejection followed by capture of the droplet into an LVC-MS sampling probe. Once exposed to an appropriate solvent, the cell is lysed, extracted, and analyzed by MS. The SCP-LVC-MS approach was validated by measuring the lipid composition of microalgae, Chlamydomonas reinhardtii (ChRe) and Euglena gracilis (EuGr), and HeLa cells in their native growth media. Numerous diacylglyceryltrimethylhomo-Ser (DGTS), phosphatidylcholine (PC), monogalactosyldiacylglycerol (MGDG), and digalactosyldiacylglycerol (DGDG) lipids were observed in single cells. Continuous solvent flow ensures that cells are analyzed rapidly, and no signal carryover between cells is observed. ChRe and EuGr microalgae mixed together in the same solution were differentiated cell-by-cell in real-time based on differences between levels of diacylglyceryltrimethylhomo-Ser (DGTS) and phosphatidylcholine (PC) lipids measured in each cell. Several DGTS lipids present in ChRe were quantified with single-cell resolution by normalizing to a DGTS(32:0) internal standard added to the LVC probe solvent during analysis. Quantitative peak areas were validated by comparing to bulk lipid extracts. Furthermore, peak area distributions comprised of hundreds of cells were compared for ChRe after 5 days of nitrogen-limited and normal growth conditions, which show clear differences and the ability to resolve cellular population differences with single-cell resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment and Non-Destructive Evaluation of the Influence of Residual Solvent on a Two-Part Epoxy-Based Adhesive Using Ultrasonics

Polymers are increasingly being used in higher demanding applications due to their ability to tailor the properties of structures while allowing for a weight and cost reduction. Solvents play an important role in the manufacture of polymeric structures since they allow for a reduction in the polymer’s viscosity or assist with the dispersion of fillers into the polymer matrix. However, the incorrect removal of the solvent affects both the physical and chemical properties of polymeric materials. The presence of residual solvent can also negatively affect the curing kinetics and the final quality of polymers. Destructive testing is mainly performed to characterize the properties of these materials. However, this type of testing involves using lab-type equipment that cannot be taken in-field to perform in situ testing and requires a specific sample preparation. Here, a method is presented to non-destructively evaluate the curing process and final viscoelastic properties of polymeric materials using ultrasonics. In this study, changes in longitudinal sound speed were detected during the curing of an aerospace epoxy adhesive as a result of variations in polymer chemistry. To simulate the presence of residual solvent, samples containing different weight percentages of isopropyl alcohol were manufactured and tested using ultrasonics. Thermogravimetric analysis was used to show changes in the decomposition of the adhesive due to the presence of IPA within the polymer structure. Adding 2, 4, and 6 wt.% of IPA decreased the adhesive’s lap shear strength by 40, 58, and 71%, respectively. Ultrasonics were used to show how the solvent influenced the curing process and the final sound speed of the adhesive. Young’s modulus and Poisson’s ratio were determined using both the longitudinal and shear sound speeds of the adhesive. Using ultrasonics has the potential to non-invasively characterize the quality of polymers in both an in-field and manufacturing settings, ensuring their reliability during use in demanding applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The beamline ID32 at the ESRF for soft X-ray high energy resolution resonant inelastic X-ray scattering and polarisation dependent X-ray absorption spectroscopy

Here, the ID32 Soft X-ray Beamline line is an ESRF upgrade beamline for X-ray absorption (XAS) and Resonant Inelastic X-ray Scattering (RIXS) spectroscopic studies. It was opened to Users in October 2014 and provides polarised soft X-rays in the 400–1600 eV energy range. It has two branches: One branch has been designed for X-ray magnetic dichroism experiments, both linear (XMLD) and circular (XMCD), with high sensitivity, reproducibility, flexibility, user friendliness and the capability for fast energy scanning. The X-ray beam is available in two experimental areas, one with a dedicated superconducting high field magnet and a sample preparation facility, the second area being open for User instruments. The other branch is dedicated to very high energy resolution Resonant Inelastic X-ray Scattering experiments with a combined resolving power up to 30 000 around 930 eV. A scattering arm which is continuously variable under UHV vacuum over 100 degrees and a four-circle sample goniometer allows accurate positioning of the sample to enable 3D mapping of q space. Combined with the possibility of polarisation analysis of the outgoing photons the beamline provides a state-of-the-art soft X-ray RIXS facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Off-Stoichiometry on Electrical Conductivity in Ni-Fe and Mn-Co Spinel Systems

This study seeks to clarify the effects of off-stoichiometry on the electrical conductivity of spinels in the (Ni,Fe) 3 O 4 and (Mn,Co) 3 O 4 systems. Spinels with the compositions Ni x Fe 3–x O 4 (where x = 0.85, 0.875, 0.9, 1.0, 1.05, and 1.15) and Mn x Co 3–x O 4 (where x = 1.0, 1.2, 1.35, 1.5, 1.75, and 2.0) were prepared using conventional solid-state process. Electrical conductivity measurements were taken between 500 °C and 800 °C using the 4-point DC method. The conductivity in Ni-Fe spinels increased with increasing Fe content. Similarly, the conductivity of Mn-Co spinels increased drastically with increasing Co content. The coefficients of thermal expansion (CTEs) of these samples were also evaluated. All the (Ni,Fe) 3 O 4 spinels were found to exhibit excellent CTE matching with prospective stack components. However, thermal expansion characteristics were highly dependent on the composition in the (Mn,Co) 3 O 4 system, and only a narrow range of compositions was well-matched in CTE with prospective stack components. The significant effect of cation off-stoichiometry and sample preparation on the electrical behavior of spinels was discussed as a possible explanation for the large discrepancies in reported conductivity values for both systems.

08 HYDROGEN↗

High modulus high temperature glass fibers

The search for a new high-modulus, high-temperature glass fiber involved the preparation of 500 glass compositions lying in 12 glass fields. These systems consisted primarily of low atomic number oxides and rare-earth oxides. Direct optical measurements of the kinetics of crystallization of the cordierite-rare earth system, for example, showed that the addition of rare-earth oxides decreased the rate of formation of cordierite crystals. Glass samples prepared from these systems proved that the rare-earth oxides made large specific contributions to the Young's modulus of the glasses. The best glasses have moduli greater than 21 million psi, the best glass fibers have moduli greater than 18 million psi, and the best glass fiber-epoxy resin composites have tensile strengths of 298,000 psi, compressive strengths of at least 220,000 psi, flexural strengths of 290,000 psi, and short-beam shear strengths of almost 17,000 psi.

Bacon, J. F.↗

Curating NASA's Past, Present, and Future Astromaterial Sample Collections

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC curation) is responsible for curating all of NASA's extraterrestrial samples. JSC presently curates 9 different astromaterials collections in seven different clean-room suites: (1) Apollo Samples (ISO (International Standards Organization) class 6 + 7); (2) Antarctic Meteorites (ISO 6 + 7); (3) Cosmic Dust Particles (ISO 5); (4) Microparticle Impact Collection (ISO 7; formerly called Space-Exposed Hardware); (5) Genesis Solar Wind Atoms (ISO 4); (6) Stardust Comet Particles (ISO 5); (7) Stardust Interstellar Particles (ISO 5); (8) Hayabusa Asteroid Particles (ISO 5); (9) OSIRIS-REx Spacecraft Coupons and Witness Plates (ISO 7). Additional cleanrooms are currently being planned to house samples from two new collections, Hayabusa 2 (2021) and OSIRIS-REx (2023). In addition to the labs that house the samples, we maintain a wide variety of infra-structure facilities required to support the clean rooms: HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system, and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam sections. We routinely monitor the cleanliness of our clean rooms and infrastructure systems, including measurements of inorganic or organic contamination, weekly airborne particle counts, compositional and isotopic monitoring of liquid N2 deliveries, and daily UPW system monitoring. In addition to the physical maintenance of the samples, we track within our databases the current and ever changing characteristics (weight, location, etc.) of more than 250,000 individually numbered samples across our various collections, as well as more than 100,000 images, and countless "analog" records that record the sample processing records of each individual sample. JSC Curation is co-located with JSC's Astromaterials Research Office, which houses a world-class suite of analytical instrumentation and scientists. We leverage these labs and personnel to better curate the samples. Part of the cu-ration process is planning for the future, and we refer to these planning efforts as "advanced curation". Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of collections as envi-sioned by NASA exploration goals. We are (and have been) planning for future cu-ration, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples.

Zeigler, R. A.↗

Doping Effect of Fe Ions on the Structural, Electrical, and Magnetic Properties of SrTiO{sub 3} Nanoceramic Matrix

In the present investigation, strontium titanate nanoceramic was synthesized by incorporating iron (Fe) ion with general formula SrTi{sub 1−x}Fe{sub x}O{sub 3} (x = 0.0, 0.1, 0.2, and 0.4) using sol-gel autocombustion method. The effect of Fe ions on the structural, morphological, electrical, dielectric, and magnetic properties of the prepared matrix has been investigated by various characterization techniques with the appropriate formulation. The structural properties such as phase space, crystallite size (D), and lattice parameter (a) of prepared matrix are calculated by X-ray diffraction (XRD) technique. The functional groups were analyzed by Fourier transform infrared spectroscopy (FT-IR). The surface morphology of the prepared nanoceramic matrix has been determined by using field emission scanning electron microscopy (FE-SEM) analysis. Calculation of average particle size and diffraction patterns was confirmed by using images from transmission electron microscopy (TEM) and selected area electron diffraction pattern (SAED), respectively. An energy dispersive spectrum analysis (EDS) confirmed the compositional stoichiometry in the investigated matrix. Electrical conductivity increased the prepared sample due to the increasing in the Fe concentration and temperature. The dielectric parameters in the frequency range of 30 Hz to 1 MHz were found higher at lower frequencies. The pure SrTiO{sub 3} matrix shows a paramagnetic nature at room temperature, but for a higher concentration of Fe doping was used to observe the weak ferromagnetic nature. Therefore, due to Fe ion concentration, the properties of the prepared matrix have been completely varied and enhancement in the magnetic properties was observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

DISORDERED SILICATES IN SPACE: A STUDY OF LABORATORY SPECTRA OF 'AMORPHOUS' SILICATES

We present a laboratory study of silicate glasses of astrophysically relevant compositions including olivines, pyroxenes, and melilites. With emphasis on the classic Si-O stretching feature near 10 {mu}m, we compare infrared spectra of our new samples with laboratory spectra on ostensibly similar compositions, and also with synthetic silicate spectral data commonly used in dust modeling. Several different factors affect spectral features including sample chemistry (e.g., polymerization, Mg/Fe ratio, oxidation state, and Al-content) whereas different sample preparation techniques lead to variations in porosity, density, and water content. The convolution of chemical and physical effects makes it difficult to attribute changes in spectral parameters to any given variable. It is important that detailed chemical and structural characterization be provided along with laboratory spectra. In addition to composition and density, we measured the glass transition temperatures for the samples which place upper limits on the formation and/or processing temperatures of these solids in space. Popular synthetically generated optical functions do not have spectral features that match any of our glass samples. However, the {approx}10 {mu}m feature generated by the synthetic data rarely exactly matches the shape and peak position of astronomically observed silicate features. Our comparison with the synthetic spectra allows astronomers to determine likely candidates among our glass samples for matching astronomical observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Micro- to nano-scale areal heterogeneity in pore structure and mineral compositions of a sub-decimeter-sized Eagle Ford Shale

Mineral and organic matter compositions & pore structures of fine-grained shale influence reservoir properties. To improve the understanding of spatial heterogeneity in core-sized samples, methods of microscale X-ray fluorescence (μXRF) mapping, (ultra-) small-angle x-ray scattering [(U)SAXS] and wide-angle X-ray scattering (WAXS) have been used to determine elemental, pore-structure variations at scales up to ~10 cm on two samples prepared at circular and rectangular orientations from a piece of Eagle Ford Shale outcrop in South Texas, USA. In addition, thin section petrography and field emission-scanning electron microscopy observations, X-ray diffraction (XRD), total organic carbon, and pyrolysis were utilized to investigate the potential spatial heterogeneity of pore types, mineral and organic matter compositions for cm-sized samples at both orientations. Overall, the siliceous-carbonate mineral contents in these two samples (8 cm×8 cm×0.08 cm and 5 cm × 8 cm × 0.08 cm, in terms of width×length×thickness) of carbonate-rich Eagle Ford Shale vary between laminations at mm scales. For the circular sample, porosity and specific surface area (SSA) variations range from 0.82 to 3.04% and 1.51 to 14.1 m 2 /g, respectively. For the rectangular sample, values for porosity and SSA vary from 0.93 to 2.50% and 3.95 to 10.8 m 2 /g. By analyzing six selected sub-samples on each of two samples with (U)SAXS and XRD techniques, nm-sized pores are mainly interparticle ones in the higher calcite regions, where the porosity is also relatively lower, while the lower calcite regions consist of both interparticle and intraparticle pore types with higher porosity. Lastly, the μXRF and (U)SAXS mappings are combined to generate porosity distribution maps to provide more insights about sample heterogeneity related to the laminations and fractures at our observational scales.

58 GEOSCIENCES↗