ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

99 GENERAL AND MISCELLANEOUS↗

Air Leakage Rates in Typical Air Barrier Assemblies

Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bringing Solid-State Magnetocaloric Cooling to the Market: A Commercialization Plan

Air conditioning has become a staple in American life, bringing improved health, productivity, and comfort to 93% of single-family homes as of 2015, compared to only 76% in 1990. This rise in demand has contributed to the 2.51 quads (12.5%) of total annual energy consumption in residential buildings attributable to space cooling (U.S. Energy Information Administration 2017). Accompanying this upward trend in space cooling has been increased refrigerant use, which has historically contributed to ozone depletion, global warming, or both. The Oak Ridge National Laboratory – along with German-based partner Vacuumschmelze GmbH & Co. KG – is working to reduce energy consumption and refrigerant use through the development of a next-generation, solid-state magnetocaloric cooling system. The purpose of this study is to investigate market potential of these systems in the United States, including information on the industry landscape, market share and unit shipment projections, optimal price points, and barriers to market entry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrification Futures Study: Scenarios of Electric Technology Adoption and Power Consumption for the United States

This report is the second in a series of Electrification Futures Study (EFS) publications, a multi-year research project to explore widespread electrification in the future energy system of the United States. The report presents scenarios of electric end-use technology adoption and resulting electricity consumption in the United States. The scenarios are used to characterize changes to end-use sectors under futures with increased electrification and to quantify how those changes might impact the amount and shape of electricity consumption. These scenarios were developed primarily using expert judgment and an energy system accounting framework. Of course, technology adoption will ultimately depend on a set of complex considerations that are not fully assessed using our methodology, but which are discussed extensively throughout the report. These interacting factors include technology and fuel cost trade-offs, infrastructure needs, environmental policies, and consumer preference. Within each of these factors are barriers that might challenge increased electrification - such as higher upfront costs or unfamiliarity with new electric technologies - but also opportunities that could yield greater adoption - such as increased productivity or expanded value streams enabled by electric and/or grid-connected technologies. Understanding and quantifying these factors are needed to both evaluate the implications of a potential increased electrification future and to influence the degree of future electrification. Overall, the report represents an initial step to inform researchers and decision-makers with data and context to plan for a potential future in which electricity powers an expanded share of the U.S. energy economy.This report is the second in a series of Electrification Futures Study (EFS) publications, a multi-year research project to explore widespread electrification in the future energy system of the United States. The report presents scenarios of electric end-use technology adoption in all major sectors - transportation, commercial and residential buildings, and industry - and resulting electricity consumption in the United States. The scenarios are used to characterize changes to end-use sectors under futures with increased electrification and to quantify how those changes might impact the amount and shape of electricity consumption. These scenarios were developed primarily using expert judgment and an energy system accounting framework. Of course, technology adoption will ultimately depend on a set of complex considerations that are not fully assessed using our methodology, but which are discussed extensively throughout the report. These interacting factors include technology and fuel cost trade-offs, infrastructure needs, environmental policies, and consumer preference. Within each of these factors are barriers that might challenge increased electrification - such as higher upfront costs or unfamiliarity with new electric technologies - but also opportunities that could yield greater adoption, such as increased productivity or expanded value streams enabled by electric and grid-connected technologies. Understanding and quantifying these factors are needed to both evaluate the implications of a potential increased electrification future and to influence the degree of future electrification. Overall, the report represents an initial step to inform researchers and decision-makers with data and context to plan for a potential future in which electricity powers an expanded share of the U.S. energy economy.

2050↗

Envelope Air Tightness for Sleeping and Dwelling Units

This technical brief investigates the potential benefits of air leakage testing in residential buildings covered by the commercial energy code and outlines an approach that could be applied based on building type, use, size and climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Cost-Effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

The purpose of this analysis is to examine the cost-effectiveness of the 2010 edition of ANSI/ASHRAE/IES1 Standard 90.1. Standard 90.1 is the model energy standard for commercial and multifamily residential buildings over three floors (ECPA, Public Law 94-385). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2007 to 90.1-2010, as applied in the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of Standard Standing Project Committee (SSPC) 90.1. The process does not include analysis of the cost-effectiveness of the entire package of addenda from one version of the standard to the next. Providing states with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Pathways to Upgrade the US Housing Stock: A Review of the Home Energy Upgrade Literature

The residential buildings sector is responsible for about 20% of total US energy use. In order to achieve climate goals, we need ways to reduce carbon emissions and energy use in this sector. In addition, resiliency, electric grid stability, emergency survivability and other energy and building-related issues are becoming increasingly important challenges. New homes in most of the US meet various energy codes and are reasonably energy efficient. However, the vast majority of energy use is from existing homes that were not required to conform to energy performance requirements. It is becoming imperative to reach as many of these existing homes as possible and find ways to improve their energy-related performance. This must be done in such a way that it meets the needs and desires of homeowners and building occupants, as well as those of the contractors and design professionals engaged in doing the upgrades themselves. Energy retrofits of homes started in the 1970’s in response to the energy crisis, however, these retrofits were very limited in scope and relatively few homes were upgraded. Those homes that have been upgraded generally still have much scope for improvement. A huge effort is needed to get to scale to address the energy use in housing. The target population is effectively every home in the country, whether a large suburban single-family home, or a small downtown apartment. In order to provide a framework for analysis and the basis for plans to get to large-scale retrofits of homes, this literature review summarizes the state-of-the art in the US buildings industry. It identifies where more research, engineering, or technology is needed, as well as relevant industry trends, such as electrification, one-stop shop program design and others. It also examines other key topics, such as availability of financing, minimizing household disruption, and engaging home owners and occupants. This literature review builds on a similar review from several years ago (Less and Walker, 2014). The current review focuses on efforts in the intervening years. This literature review is part of a larger DOE study of deep energy upgrades that includes industry surveys and development of cost-stack analyses. For this review, we gathered data not just from the published literature, but also from practitioners in conjunction with other aspects of the larger DOE study. In some cases, we refer to comments from specific individuals or companies, or refer to specific products by name. This is not intended as an endorsement, but rather to provide clarity on sources of information and examples of relevant technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advancing insulation retrofits from flexible inexpensive lucid materials (AIR FILMs) for single-pane windows

This project focused on Advancing Insulation Retrofits from Flexible Inexpensive Lucid Materials (AIR FILMs) for Single-Pane Windows. The team developed innovative porous materials that can improve the energy efficiency of existing single-pane windows in commercial and residential buildings in two technical product categories: (1) retrofits that can be applied onto existing windowpanes and (2) manufactured windowpanes that can be installed into the existing window sash.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Decarbonization and Clean Energy Pathways for Disadvantaged Communities in California

California has a state-wide goal of carbon neutrality by 2045. Decarbonization for disadvantaged communities (DACs) poses extra challenges due to financial, informational, language, and other barriers. This paper presents the methodology, results, and analysis of energy efficiency measures (EEMs) to save energy, reduce CO 2 emission, and promote clean energy access at the district scale for two DACs in Fresno, California. The methods are broadly applicable to other neighborhoods across the U.S. 22 EEMs were identified and modelled for all residential buildings in the two DACs both individually and as packages. Results show that for energy and CO 2 reduction purposes, the top performing EEM package can decrease energy use and CO 2 emissions by an average of 60%. For electrification, heat pump water heaters are a viable solution, coupled with air source or mini-split heat pumps. Replacing gasoline vehicles with electric vehicles is another important measure in electrification and reducing GHG emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DER as a service-ecoLong and VOLTTRON (Abstract)

The project goal is to commercialize the VOLTTRON-hosted “DER as a Service” (DaaS) application and make it an “out-of-the-box” solution for ecoLong to use as a secure residential energy management system that allows 1.) distributed energy resources (DERs) to participate in wholesale markets and provide services to the grid and 2.) intelligently control the energy in the residential buildings to the desired level while maintaining occupancy comfort. The product will be field deployed onto multiple Solar Liberty sites in New York state to demonstrate wide-scale participation of DERs in wholesale markets to provide services to the grid and validate the effectiveness of the solution. The integrated management of DERs and buildings increases the penetration of solar resources by managing its variability, providing grid services, and solving the evening ramping challenges. Ultimately, the DaaS platform will make buildings and DERs smarter by unlocking grid-interactive efficient buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

National Cost-effectiveness of ANSI/ASHRAE/IES Standard 90.1-2016

The purpose of this analysis is to examine the cost-effectiveness of the 2016 edition of ANSI/ASHRAE/IES Standard 90.1 (ASHRAE 2016). Standard 90.1 is developed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard Standing Project Committee (SSPC) 90.1. It is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2013 to 90.1-2016, as applied in commercial buildings across the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of ASHRAE Standard Standing Project Committee (SSPC) 90.1. The ASHRAE process, however, does not include analysis of the cost-effectiveness of the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting State and local governments. Providing States with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1. To establish the cost-effectiveness of Standard 90.1-2016, three main tasks were addressed: (1) Identification of building elements impacted by the updated standard; (2) Allocation of associated installation, maintenance, and replacement costs; and (3) Cost-effectiveness analysis of required changes In addition to installation, maintenance, and replacement costs, energy cost differences were needed to determine cost-effectiveness. The energy costs for each edition of Standard 90.1 were determined previously under the development of Standard 90.1-2016, as described below. The current analysis builds on the previous PNNL analysis (as outlined in Section 5.2) of the energy use and energy cost saving impacts of Standard 90.1-2016 compared to previous editions. The overall energy savings analysis of Standard 90.1 utilized a suite of 16 prototype EnergyPlus building models in 15 climate locations representing all eight U.S. climate zones. Detailed methodology and overall energy saving results from Standard 90.1-2016 are documented in the DOE technical report titled Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016 (DOE. 2018b).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Supply Chain Cybersecurity Recommendations for Solar Photovoltaics

Solar photovoltaic (PV) cybersecurity is a growing field of research. As deployments of solar PV has increased, cyber risk has also increased. However, utility solar PV installations are not required to comply with North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) unless they meet a minimum generation threshold of 75 Megawatts (MW). Individual residential scale solar PV deployments will not meet that generation threshold and are therefore excluded from NERC CIP requirements. With most solar installations below 75MW, solar PV has been deployed with minimal oversight and highly variable cybersecurity maturity. The resources that make up the digital supply chain can include software, code, data, as well as other digital components. However as clean energy technology advances, cybersecurity threats and vulnerabilities continue to evolve and grow in sophistication. Solar PV faces a unique challenge in which it can be deployed in residential buildings and purchased by a consumer directly. This makes the supply chain of PV a unique challenge, where responsible parties for cybersecurity vary widely depending on the type of solar PV being deployed. Supply chain cybersecurity for solar PV represents a critical area for ensuring safe operations as the U.S. moves towards a clean energy future.

14 SOLAR ENERGY↗

ResStock Communities LEAP Pilot Residential Housing Analysis - Detailed Methodology

This methodology document supports residential building analysis for some communities receiving technical assistance through the Department of Energy Communities LEAP (Local Energy Action Program). Communities LEAP supports community-wide economic and environmental benefits through technical assistance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock™ Data Visualization Tools - How to Use Them: A Demonstration [Slides]

This training from the National Renewable Energy Laboratory introduces Energy Efficiency Conservation Block Grant Program participants to ResStock, a modeling tool that can help states, municipalities, utilities, and manufacturers identify which residential building improvements save the most money and energy.