Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Effective gamma-ray doses due to natural radiation from soils of southeastern Brazil

We have used gamma-ray spectrometry to study the distribution of natural radiation from soils of southeastern Brazil: Billings reservoir, Sao Bernardo do Campo Parks, Diadema Parks, Interlagos region, Sao Paulo, and soil from Sao Paulo and Rio de Janeiro beaches. In most of the regions studied we have found that the dose due the external exposure to gamma-rays, proceeding from natural terrestrial elements, are between the values 0.3 and 0.6 mSv/year, established by the United Nations Scientific Committee on the Effects of Atomic Radiation.

54 ENVIRONMENTAL SCIENCES↗

Direct 1{sup +}{yields}N{sup +} conversion of stable alkali ions using an electron cyclotron resonance ion source

The production of radioactive ions using the Isotope Separation On-Line method gives rise, in most cases, to singly charged ions. In order to perform experiments with postaccelerated radioactive ion beams, these ions have to be multicharged. We describe here a new compact design for a charge breeder that will be coupled to the production target of SPIRAL1 at GANIL. We present recent results obtained offline with stable alkali ions (Na, K, Rb, and Cs) on the SIRa test bench. Particularly, 1{sup +} to N{sup +} conversion efficiencies and conversion times are presented. Several points have been identified for the improvements of the present performances.

43 PARTICLE ACCELERATORS↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions, Calendar Year 2010

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada National Security Site (NNSS, formerly the Nevada Test Site) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR, 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as those from the damaged Fukushima nuclear power plant in Japan. Because this report is intended to discuss radioactive air emissions during calendar year 2010, data on radionuclides in air from the 2011 Fukushima nuclear power plant releases are not presented but will be included in the report for calendar year 2011. The NNSS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations (U.S. Environmental Protection Agency [EPA] and DOE, 1995). This method was approved by the EPA for use on the NNSS in 2001(EPA, 2001a) and has been the sole method used since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR, 2010a). For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide's concentration by its CL and then adding the fractions together) is less than 1.0. In 2010, the potential dose from radiological emissions to air, resulting from both current and past NNSS activities, at onsite compliance monitoring stations was well below the 10 mrem/yr dose limit. Air sampling data collected at all air monitoring stations had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides about 20 kilometers from potential release points on the NNSS, dose to the public would be only a small fraction of that measured on the NNSS. The potential dose to the public from NLVF emissions was also very low at 0.000032 mrem/yr, more than 300,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions Calendar Year 2017

Report submitted to regulators (State of Nevada and EPA Region IV). Required to document compliance with 40 CFR 61 Subpart H. The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since nuclear testing ended in 1992, radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/y) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as Japan’s Fukushima nuclear power plant, which was damaged in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS (U.S. Environmental Protection Agency [EPA] and DOE 1995). This method was approved by the EPA in 2001 (EPA 2001a) and has been the method used to demonstrate compliance with the 40 CFR 61.92 dose standard since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations because no member of the public resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Level (CL) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR 2010a). For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2017, the potential dose from radiological emissions to air from both current and past NNSS activities was well below the 10 mrem/y dose limit. This is demonstrated by air sampling data collected at the critical receptor air monitoring stations which had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from 0.2% to a maximum of 5.7% of the allowed NESHAP limit. Clean Air Package 1988 (CAP88) was used to model dose to the offsite public from all 2017 NNSS radionuclide emissions. The model showed the maximally exposed individual to be on the adjacent U.S. Air Force Nevada Test and Training Range; this individual received a dose of 0.07 mrem/y. The potential dose to the public from NLVF emissions was also very low at 0.0000098 mrem/y, over six orders of magnitude lower than the 10 mrem/y limit.

07 ISOTOPE AND RADIATION SOURCES↗

Design and performance testing of a novel far field Gamma system to assay radioactive waste in 400 and 200 litre drums - 15339

A Far Field Gamma ray Measurement system has been developed for measuring and assaying both 400 and 200 litre waste drums with a wide range of activity at nuclear power stations. These include radioactive waste drums with surface dose-rates of less than 2 mSv/h (200 mrem/h) and, at the higher range of activity, 400 litre drums with surface dose-rates of up to 50 mSv/h (5 rem/h). The assay system incorporates an electro-mechanically cooled high purity Germanium profile detector and advanced digital spectroscopic analysis electronics. A novel optimised conical-trapezoidal collimator has been incorporated to reduce the effect of the radioactive background in addition to the conventional detector lead shield with tin and copper graded lining to reduce the effect of lead X-rays. Two features have been incorporated to reduce detector dead time and maintain detector resolution when measuring high activity drums. The first is the inclusion of two automated tungsten filters of different thickness as an integral part of the detector collimator. The filters are used in conjunction with an automated rail system on which the detector platform is mounted. The detector can be positioned at different distances from the drum surface in order to reduce detector dead time. The deployment of the filters and the adjustment of the drum - detector position are automatically controlled based on a user defined dose-rate limit table. The data is provided by two Geiger-Muller dose-rate detectors, which are used to measure the drum surface dose-rate. This data is subsequently used to adjust the detector position and in cases of higher dose-rate deploy one or other of the tungsten filters. The drum rotation platform incorporates a load cell to determine drum weight and hence the drum density. This information is used to calculate an attenuation correction based on the assumption of uniform drum density and uniform distribution of activity within the drum. Where the waste drums have a more complicated and known regular internal structure, such as a small radioactive region surrounded by an annulus of shielding material, the analysis algorithms incorporated into the far field geometry and attenuation correction spectroscopic data analysis code are able to make a more accurate determination of drum activity than would be possible assuming a completely uniform drum. The detector energy and efficiency calibration is achieved using a point source with multiple gamma ray energy peaks. The response of the high purity Germanium detector is also modelled using the Monte Carlo Neutron Photon code and the model is benchmarked using the measured point source calibration data. The performance of the instrument has been determined for a range of uniform density matrix drums containing a set of Eu-152 line or rod sources located in re-entrant tubes positioned on an equal volume basis. When rotated, the test drums with volume distributed line sources simulate waste drums of different density each with a uniformly distributed radioactive source. The measurements have been validated using Monte Carlo simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composite Analysis Solid Waste Release Data Reduction of Activity Flux from Waste Sites to the Vadose Zone for Baseline Assessment

This environmental calculation file (ECF) describes the data reduction methodology for the solid waste release datasets generated by the Composite Analysis Solid Waste Release (CASWR) model (CP-62766, Model Package Report: Composite Analysis Solid Waste Release Model [CASWR Model]) and documents the resulting reduced datasets for the updated Composite Analysis (CA) baseline assessment. This ECF is in support of the updated Hanford Site CA. The purpose of the updated Hanford Site CA is to provide an estimate of the cumulative radiological impacts from active and planned low-level radioactive waste disposals and other potentially interacting radioactive waste disposal sources that will remain following Hanford Site closure. The vadose zone modeling activities associated with the CA includes solid waste forms as contaminant sources. To support the modeling of solid waste transport from the vadose zone to the groundwater at the Hanford Site, the CASWR model was designed to generate deterministic radionuclide release rates for the Hanford Site Central Plateau solid waste disposal sites. The complete CASWR model-generated dataset for the CA Baseline Assessment consists of 2,378,831 sets of time and release rates (1,073,869 sets for the 200 East Area and 1,304,962 sets for the 200 West Area), representing a course of the simulation from year 1953 to year 12,069, 16 radiological contaminants of potential concern (COPCs), and 237 solid waste sources as documented in ECFHANFORD- 19-0112, Solid Waste Release Calculations for the Composite Analysis Baseline Assessment. For several of the STOMP vadose zone models, the number of release rate data pairs required for release at all waste sites would exceed the limitations imposed by the STOMP modelling software package used to simulate contaminant transport through the vadose zone. As a result, a data reduction of the CASWR dataset is required prior to its use as a source input for the CA vadose zone modeling activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LUXSim: A component-centric approach to low-background simulations

Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. Here, we describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Series Evaluation of Portal Monitor Data

Radiation portal monitors screen cargo and personal vehicle traffic at international border crossings to detect and interdict illicit sources which may be present in the commerce stream. One difficulty faced by RPM systems is the prospect of false alarms, or undesired alarms due to background fluctuation, or Naturally-Occurring Radioactive Material (NORM) sources in the commerce stream. In general, NORM alarms represent a significant fraction of the nuisance alarms at international border crossings, particularly with Polyvinyl-Toluene (PVT) RPM detectors, which have only very weak spectral differentiation capability. With PVT detectors, the majority of detected photon events fall within the Compton continuum of the material, allowing for very little spectral information to be preserved [1]. Previous work has shown that these detectors can be used for limited spectroscopy, utilizing around 8 spectral bins to further differentiate some NORM and other nuisance sources [2]. NaI based systems achieve much more detailed spectral resolution from each measurement of a source, but still combine all measurements over a vehicle's occupancy in order to arrive at a spectrum to be analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation Leakage and the Precision of Characterizing Nuclear Material Using Calorimetric Assay - 19233

For measuring a waste drum containing multi-nuclide radioactive material calorimetric assay is often combined with gamma ray and neutron measurements. To reduce the methodological uncertainties of the inventory determination in a multi-nuclide matrix, the escaping radiation must be quantized as much as the encapsulated gamma-rays and α-, β-, n- particles depositing radiological heat inside the drum. To differentiate the possible variety of heat sources in a radioactive waste drum, Monte Carlo simulations are utilized resembling the waste drum and the calorimeter in both, their geometries as well as the material compositions. MCNP6-based numerical imaging of the Large Volume Calorimeter (LVC) designed by KEP Nuclear(France) allows simulating various scenarios for different particles types, energies and source locations to accompany and support the interpretation of calorimetric KEP-LVC measurements anticipated within the CHANCE project. For the analyses, the particle flux and energy deposition in each layer of the calorimeter are displayed. The results yield that a significant part of the emitted radiation leaves the system and does not contribute to the heat deposited inside the drum. As an example, the particle flux study of a 200 L mock-up drum placed inside the KEP-LVC calorimeter is discussed. A tally 4 with mesh option for both gamma and neutrons up to 5 MeV simulates the mean flux in each cell and for various source location and source distribution patterns. The expected energy deposition is cumulated for each layer, and over the whole energy range it reveals that actually a small but well known fraction of particles escapes the LVC calorimeter. This makes it a very suitable apparatus for the anticipated experiments on large and heterogeneous waste drums. The results suggest that the most interesting cases would be polyethylene, bitumen and concrete matrices [3, 5]. However, it must be kept in mind that the high-energy part of the gamma and neutron radiation flux can reach the reference chamber of the calorimeter and deposit some energy there, which may compromise the calibration and cause double-bias. The simulations showed that, depending on source location and power, neutron and high-energy gamma radiation leakage can influence the heat measurements differently. In general, part of the simulation results suggest that for waste drums with a high emission rate the accuracy of calorimetric assay can be decreased due to radiation escape. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rational Ligand Design for U(VI) and Pu(IV)

Nuclear power is an attractive alternative to hydrocarbon-based energy production at a time when moving away from carbon-producing processes is widely accepted as a significant developmental need. Hence, the radioactive actinide power sources for this industry are necessarily becoming more widespread, which is accompanied by the increased risk of exposure to both biological and environmental systems. This, in turn, requires the development of technology designed to remove such radioactive threats efficiently and selectively from contaminated material, whether that be contained nuclear waste streams or the human body. Raymond and coworkers (University of California, Berkeley) have for decades investigated the interaction of biologically-inspired, hard Lewis-base ligands with high-valent, early-actinide cations. It has been established that such ligands bind strongly to the hard Lewis-acidic early actinides, and many poly-bidentate ligands have been developed and shown to be effective chelators of actinide contaminants in vivo. Work reported herein explores the effect of ligand geometry on the linear U(IV) dioxo dication (uranyl, UO 2 2+ ). The goal is to utilize rational ligand design to develop ligands that exhibit shape selectivity towards linear dioxo cations and provides thermodynamically favorable binding interactions. The uranyl complexes with a series of tetradentate 3-hydroxy-pyridin-2-one (3,2-HOPO) ligands were studied in both the crystalline state as well as in solution. Despite significant geometric differences, the uranyl affinities of these ligands vary only slightly but are better than DTPA, the only FDA-approved chelation therapy for actinide contamination. The terepthalamide (TAM) moiety was combined into tris-beidentate ligands with 1,2- and 3,2-HOPO moieties were combined into hexadentate ligands whose structural preferences and solution thermodynamics were measured with the uranyl cation. In addition to achieving coordinative saturation, these ligands exhibited increased uranyl affinity compared to bis-Me-3,2-HOPO ligands. This result is due in part to their increased denticity, but is primarily the result of the presence of the TAM moiety. In an effort to explore the relatively unexplored coordination chemistry of Pu(IV) with bidentate moieties, a series of Pu(IV) complexes were also crystallized using bidentate hydroxypyridinone and hydroxypyrone ligands. The geometries of these complexes are compared to that of the analogous Ce(IV) complexes. While in some cases these showed the expected structural similarities, some ligand systems led to significant coordination changes. A series of crystal structure analyses with Ce(IV) indicated that these differences are most likely the result of crystallization condition differences and solvent inclusion effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disentangling the sources of ionizing radiation in superconducting qubits

Abstract Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of radioactivity present in a typical laboratory environment (from muons, neutrons, and $$\gamma $$ γ -rays emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly and operation of state-of-the-art superconducting qubits. We present a GEANT-4 based simulation to predict the rate of impacts and the amount of energy released in a qubit chip from each of the mentioned sources. We finally propose mitigation strategies for the operation of next-generation qubits in a radio-pure environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MODEL IMPLEMENTATION TO EVALUATE THE COLLECTIVE FUTURE RADIONUCLIDE RELEASES FROM MULTIPLE FACILITIES AT THE SAVANNAH RIVER SITE

A comprehensive Composite Analysis (CA) has been performed considering 152 sources of residual radioactive material at the Savannah River Site (SRS). As part of the CA a model was developed to perform deterministic base case calculations using the commercial GoldSim software. The model treated transport and decay of radionuclides as they are released at the source location and transported through the source region, vadose zone and aquifer to stream outcrops and from there to the Savannah River. A dose to the public was calculated assuming recreational use of stream water and residential use of river water. The specific results from the GoldSim modeling evaluation conducted as part of the CA indicate that the collective maximum dose resulting from the release of radionuclides from all 152 anticipated SRS End State sources of residual radionuclides demonstrate that maximum exposures expected to occur to any offsite MOP will not approach the 300 uSv/yr (30 mrem/yr) dose constraint, and in fact are currently estimated to be only 10% of this. For each of the POA's evaluated, the highest cumulative dose is realized at the Lower Three Runs POA and is calculated to be 29.7 uSv/yr (2.97 mrem/yr). The major dose contributing radionuclide for all of the POA's, with the exception of Upper Three Runs, was {sup 137}Cs in the contaminated streambed sediments. In Upper Three Runs {sup 237}Np from the H-Area Canyon Building was the major dose contributing radionuclide. The major exposure pathway for the SRS streams (where the Recreational Scenario was evaluated) was by the ingestion of fish. In the Savannah River, where the Residential Scenario was evaluated, ingestion of vegetation was the dominant exposure pathway. The uncertainty evaluation lends added assurance to the conclusion that the 30 mrem/yr dose constraint will not be exceeded, in that even at the 95th Percentile, this performance measure is not expected to be exceeded. It must also be added that these conclusions should be regarded as 'preliminary' since the DOE review process of the SRS CA has not yet been completed.

54 ENVIRONMENTAL SCIENCES↗

Containment at the Source during Waste Volume Reduction of Large Radioactive Components Using Oxylance High-Temperature Cutting Equipment - 13595

As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Forensics for Irradiated Materials using Kernel Regression Models

The ultimate purpose of nuclear forensics is to locate the origin of nuclear and other radioactive materials out of regulatory control used in nuclear security events such as classical forensics. For this purpose, some specific characteristics of interdicted materials (referred to as 'signatures') should be defined to compare the known sample database. In some cases, involved with irradiated material, the signatures could be specific amount of fission product inventory depending on reactor operational histories such as reactor type, initial enrichment, burn up rate of nuclear fuel and cooling period after irradiation in the reactor. In order to make inference model for irradiated material for nuclear forensics, we suggested 3 ways as follows; (i) analyzing ORIGEN produced nuclear substances for the fission product inventory, (ii) classifying the range of reactor type, (iii) predicting the operational history from the fission product inventory. In terms of nuclear substance analysis, the construction of spent fuel database has been internationally carried out since ITWG (Nuclear Smuggling International Technical Working Group) was established in 1995. However, enough sample data cannot be obtained in Korea to determine reactor type and operational histories because analyzing nuclear substances have been limited due to the international regulation. Thus, this study does not mention how to obtain mass or ratios of nuclides for the spent fuel. We just have generated simulation sample data as a fission product inventory using ORIGEN to construct spent fuel database. When unidentified radioactive materials are discovered, it is assumed that mass or ratios of the nuclides are analyzed by certain methods which are available in Korea as well as other countries. Then, a reactor type is determined, and finally, regression model can locate the origin or source of the radioactive materials by inferring operational histories using the fission product inventory. There are some studies on the classification of reactor type using statistical methods. As a part of predicting the operational history, this paper focuses on the development of spent fuel inference algorithm for nuclear forensics to estimate reactor operational histories that reflect characteristics of a reactor from the fission product inventory. The spent fuel inference algorithm for nuclear forensics has been developed on the basis of Kernel Regression (KR) which can conditionally generate the estimated output data by giving weight depending on geometric distance between sample data and input data. Also the KR which comprises Auto-Associative KR and Inferential KR have some benefits that can estimate only using data without assumption for specific physical model and re-learning process. Auto-associative KR (AAKR) was used to sort out outliers of input data and Inferential KR (IKR) was carried out to predict the operational histories for spent fuel. All of regression algorithms were performed in R programming tool. From the validation of both AAKR and IKR, it is expected that kernel regression has enough accuracy to be applied to nuclear forensics for spent fuel. Once the nuclear substance is measured to fill the fission product inventory with a certain reactor type, this kernel regression algorithm would predict the operational histories of spent fuel with high accuracy. Finally, this information is expected to be useful to find the origin of irradiated materials. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vacuum arc with a distributed cathode spot as a plasma source for plasma separation of spent nuclear fuel and radioactive waste

Results from experimental studies of a vacuum arc with a distributed cathode spot on the heated cathode are presented. Such an arc can be used as a plasma source for plasma separation of spent nuclear fuel and radioactive waste. The experiments were performed with a gadolinium cathode, the properties of which are similar to those of an uranium arc cathode. The heat flux from the plasma to the cathode (and its volt equivalent) at discharge voltages of 4-15 V and discharge currents of 44-81 A, the radial distribution of the emission intensity of gadolinium atoms and singly charged ions in the arc channel at a voltage of 4.3 V, and the plasma electron temperature behind the anode were measured. The average charge of plasma ions at arc voltages of 3.5-8 V and a discharge current of 52 A and the average rate of gadolinium evaporation in the discharge were also determined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Range, resolution and power of THz systems for remote detection of concealed radioactive materials

This paper analyzes parameters required for realizing remote detection of a concealed source of ionizing radiation by observing the occurrence of breakdown in air by a focused wave beam. Production of free electrons and the free electron density in the absence/presence of additional sources of ionization are analyzed. The maximum electron density in the discharge and the time required for this density to return after the discharge back to its stationary level, are estimated. The optimal excess of the power density and the corresponding power level as the function of frequency are determined. It is shown that the optimal frequency of such systems ranges from 0.3 up to 0.8 THz. The paper also determines the range of such systems as the function of the source frequency and power and contains a brief analysis of available sources of microwave, millimeter-wave and THz radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗