Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Erratum to. Energy calibration of gamma spectra in plastic scintillators using Compton kinematics [Nucl. Instr. and Meth. A 594 (2008) 232–243]

In recent work at our laboratory, we were re-examining our data and found an inconsistency between the values listed for 137 Cs in Table 2 (Siciliano et al. 2008) and results plotted for that source in Figures 11 and 12. In the course of fitting the parabolic function (Equation 4) to the Compton maxima, two ranges of channels were used when determining the parameters for 137 Cs. The parabolic fit curve shown in Figure 11 resulted from fitting channels 50 to 70. The parameters for that fit are: are: A = 0.972(12), B = 1.42(24) x 10 -3 , and C NO = 60.2(5). The parameters for 137 Cs listed in Table 2 (and also used to determine the calibration relations in Figure 12—the main result of this paper) came from fitting the 137 Cs data in channels 40 to 80. Although the curves plotted from these two different sets of parameters would be visually distinguishable in Figure 11, when incorporated with the other isotope values shown in Figure 12 to obtain the linear energy-channel fit, the 50-70 channel parameter set plus the correction from the Compton maximum to the Compton edge gives a negligible change in the slope [6.470(41) as opposed to the reported 6.454(15) keV/channel] and a small change in the intercept [41(8) as opposed to 47(3) keV] for the dashed line. The conclusions of the article therefore do not change as a result of this inconsistency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive model of scintillator plastic fogging in portals

We have developed a science-based predictive model for fogging of the scintillator plastics deployed in radiation portal monitors. The only input required is the weather conditions [i.e., daily high and low, for temperature and relative humidity (R.H.)]. The code utilizes this information, together with a thermodynamic model of the water content in equilibrium with the plastic surface, a diffusion model of the water transport into the interior of scintillator plastic panel, and a comparison of the resulting paired “water-content/night-temperature” points as a function of position in the panel against an empirical “fog-line” that establishes a water/temperature criterion for the onset of fogging. In conclusion, we have analyzed the behavior of several representative portal monitor sites, and the output of the model analysis is reasonably consistent with observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nature of Moisture-Induced fogging defects in scintillator plastic

Polyvinyl toluene (PVT) scintillator plastic may degrade in the field due to inward water diffusion at elevated temperatures, which exceeds the saturation limit at lower temperatures, and after long periods of time (e.g., many years), leads to the formation of disk-like defects that attenuate scintillation light, leading to detector degradation. In this work, using fractography and high-magnification optical and electron microscopy to characterize the water-induced defects, a model of the fogging process is hypothesized as follows: excess water present at low temperatures diffuses to spheroids to minimize contact with the hydrophobic polymer. Through the hydrophobic effect, the entropy of water increases by forming nanoclusters which minimizes the contact between the water and the PVT. As the water nanoclusters grow, they break and fold the polymer into densely-packed crystalline regions creating more space for water within the spheroids. The polymer outside the spheroid resists the shrinkage which builds up tension within the spheroid. Once the tensile stress exceeds the yield strength of the plastic, the spheroid is torn in half resulting in a defect. Excess water then drains into the cavities along the disk thereby further increasing its entropy. Slower cooling (over 1 day) leads to larger spheroids and hence, larger “permanent” defects. Freezing causes some defects to further grow due to the expansion of water to ice. These findings imply that the remaining lifetime of scintillator plastic in the field could be predicted using temperature and humidity data thereby mitigating security risks of degraded radiation portal monitors.

36 MATERIALS SCIENCE↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Czochralski Growth and Characterization of a Compositionally Complex Rare Earth Aluminum Garnet Scintillator: (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce

Compositionally complex oxides have garnered increasing interest for their enhanced phase stability and tunable functional properties, yet their development as bulk single crystal scintillators remains limited. Herein, we report the Czochralski growth and characterization of (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), a compositionally complex garnet incorporating four dodecahedrally coordinated principal rare earth elements. The garnet phase was confirmed by powder and single crystal X-ray diffraction, and macroscopic defects are described. X-ray absorption near-edge structure measurements confirm the 3+ oxidation state of all rare earths and support their occupation of the same crystallographic site; white line intensity variations correlate with the anticipated segregation behavior. Elemental segregation is quantified by SEM/EDS and ICP-OES, and a linear trend was established between the segregation coefficient and the difference between each rare earth’s ionic radius (r) and the average ionic radius (AIR) of the dodecahedral site. This trend offers a predictive framework for compositional control in future REAG crystals grown by the Czochralski method. Photoluminescence and radioluminescence measurements reveal both Ce 3+ and Tb 3+ emission. Scintillation pulses exhibit four-component decay with dominant ~230 µs and ~1.2 ms components, and the light yield is estimated to be up to 43,000 ph/MeV under 137Cs γ-ray excitation. GYTLAG also demonstrates a strong radioluminescence efficiency and 50% lower afterglow at 20 ms compared to a LuAG:Ce reference, underscoring its promise for scintillator applications.

Compositionally complex oxide, high entropy oxide,↗

Electrochemical Behavior of Disposable Electrodes Prepared by Ion Beam Based Surface Modification for Biomolecular Recognition

Many important technological advances have been made in the development of technologies to monitor interactions and recognition events of biomolecules in solution and on solid substrates. The development of advanced biosensors could impact significantly the areas of genomics, proteomics, biomedical diagnostics and drug discovery. In the literature, there have recently appeared an impressive number of intensive designs for electrochemical monitoring of biomolecular recognition. Herein, the influence of ion implanted disposable graphite electrodes on biomolecular recognition and their electrochemical behaviour was investigated.

60 APPLIED LIFE SCIENCES↗

N- and P-Type Cluster Source

We describe our newest ClusterIon registered source, and show detailed data for B{sub 18}H{sub x}{sup +}, C{sub 7}H{sub 7}{sup +}, C{sub 16}H{sub x}{sup +}, P{sub 4}{sup +}, and As{sub 4}{sup +} beams. These species are derived from both low-temperature solids and gaseous sources. 2D beam profiles are presented, along with mass spectra, beam current performance, and long-term beam reproducibility. The data were collected using the injection stage of a commercial ion implanter equipped with a 120 degree analyzer magnet. Beam profiles at magnet entrance and exit planes were produced using a specially designed 2D profiler. Beam currents were measured after mass analysis using a Faraday cup over an effective energy range of 200 eV to 10 keV.

43 PARTICLE ACCELERATORS↗

Imaging Fukushima Daiichi reactors with muons

A study of imaging the Fukushima Daiichi reactors with cosmic-ray muons to assess the damage to the reactors is presented. Muon scattering imaging has high sensitivity for detecting uranium fuel and debris even through thick concrete walls and a reactor pressure vessel. Technical demonstrations using a reactor mockup, detector radiation test at Fukushima Daiichi, and simulation studies have been carried out. These studies establish feasibility for the reactor imaging. A few months of measurement will reveal the spatial distribution of the reactor fuel. The muon scattering technique would be the best and probably the only way for Fukushima Daiichi to make this determination in the near future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks

In this work the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks is evaluated. The first one code based on traditional iterative procedures and called Neutron spectrometry and dosimetry from the Universidad Autonoma de Zacatecas (NSDUAZ) use the SPUNIT iterative algorithm and was designed to unfold neutron spectrum and calculate 15 dosimetric quantities and 7 IAEA survey meters. The main feature of this code is the automated selection of the initial guess spectrum trough a compendium of neutron spectrum compiled by the IAEA. The second one code known as Neutron spectrometry and dosimetry with artificial neural networks (NDSann) is a code designed using neural nets technology. The artificial intelligence approach of neural net does not solve mathematical equations. By using the knowledge stored at synaptic weights on a neural net properly trained, the code is capable to unfold neutron spectrum and to simultaneously calculate 15 dosimetric quantities, needing as entrance data, only the rate counts measured with a Bonner spheres system. Similarities of both NSDUAZ and NSDann codes are: they follow the same easy and intuitive user's philosophy and were designed in a graphical interface under the LabVIEW programming environment. Both codes unfold the neutron spectrum expressed in 60 energy bins, calculate 15 dosimetric quantities and generate a full report in HTML format. Differences of these codes are: NSDUAZ code was designed using classical iterative approaches and needs an initial guess spectrum in order to initiate the iterative procedure. In NSDUAZ, a programming routine was designed to calculate 7 IAEA instrument survey meters using the fluence-dose conversion coefficients. NSDann code use artificial neural networks for solving the ill-conditioned equation system of neutron spectrometry problem through synaptic weights of a properly trained neural network. Contrary to iterative procedures, in neural net approach it is possible to reduce the rate counts used to unfold the neutron spectrum. To evaluate these codes a computer tool called Neutron Spectrometry and dosimetry computer tool was designed. The results obtained with this package are showed. The codes here mentioned are freely available upon request to the authors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements

Computer software for calculation of the sensitivity of a CR-39 detector closed in a diffusion chamber to radon is described in this work. The software consists of two programs, both written in the standard Fortran 90 programming language. The physical background and a numerical example are given. Presented software is intended for numerous researches in radon measurement community. Previously published computer programs TRACK-TEST.F90 and TRACK-VISION.F90 [D. Nikezic and K. N. Yu, Comput. Phys. Commun. 174, 160 (2006); D. Nikezic and K. N. Yu, Comput. Phys. Commun. 178, 591 (2008)] are used here as subroutines to calculate the track parameters and to determine whether the track is visible or not, based on the incident angle, impact energy, etching conditions, gray level, and visibility criterion. The results obtained by the software, using five different V functions, were compared with the experimental data found in the literature. Application of two functions in this software reproduced experimental data very well, while other three gave lower sensitivity than experiment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Local measurement of bulk thermal diffusivity using photothermal radiometry

Here, an experimental methodology using photothermal radiometry is developed for the accurate measurement of bulk thermal diffusivity of nuclear fuels and materials irradiated to high doses. Under these conditions, nuclear fuels, such as uranium oxide, and moderator materials, such as graphite, become friable, which requires characterization techniques that can accommodate irregularly shaped fragments. Photothermal radiometry, a good candidate for this application, involves locally heating a sample by using a laser and measuring the temperature field by monitoring blackbody radiation. The interaction volume for this study, less than a millimeter, is carefully chosen to sample a statistically significant number of large-scale structural features, such as pores and gas filled bubbles, and is small enough that the sample fragments can be treated as a thermal half-space. The thermal diffusivity standards considered in this study cover a range of thermal diffusivities representative of both fresh and spent nuclear fuels. We also consider a sample having a porous microstructure representative of large-scale structures found in materials irradiated to high doses. Our measurement methodology circumvents complex thermal wave models that address optical diffraction, nonlinear transfer function associated with blackbody radiation, and finite sample size effects. Consequently, the large measurement uncertainty associated with modeling these effects can be avoided. While the emphasis here is on nuclear fuels and materials, this measurement approach is well suited to measure thermal transport in a variety of technologically important materials associated with advanced synthesis techniques. Examples range from small, exotic single crystals grown using hydrothermal growth techniques to additively manufactured components having complex geometries.

36 MATERIALS SCIENCE↗

Mortality among workers at the Los Alamos National Laboratory, 1943–2017

During World War II (WWII), the Manhattan Engineering District established a secret laboratory in the mountains of northern New Mexico. The mission was to design, construct and test the first atomic weapon, nicknamed ‘The Gadget’ that was detonated at the TRINITY site in Alamogordo, NM. After WWII, nuclear weapons research continued, and the laboratory became the Los Alamos National Laboratory (LANL). The mortality experience of 26,328 workers first employed between 1943 and 1980 at LANL was determined through 2017. Included were 6157 contract workers employed by the ZIA Company. Organ dose estimates for each worker considered all sources of exposure, notably photons, neutrons, tritium, 238Pu and 239Pu. Vital status determination included searches within the National Death Index, Social Security Administration and New Mexico State Mortality Files. Standardized Mortality Ratios (SMR) and Cox regression models were used in the analyses. Most workers (55%) were hired before 1960, 38% had a college degree, 25% were female, 81% white, 13% Hispanic and 60% had died. Vital status was complete, with only 0.1% lost to follow-up. The mean dose to the lung for the 17,053 workers monitored for radiation was 28.6 weighted-mGy (maximum 16.8 weighted-Gy) assuming a Dose Weighting Factor of 20 for alpha particle dose to lung. The Excess Relative Risk (ERR) at 100 weighted-mGy was 0.01 (95%CI -0.02, 0.03; n = 839) for lung cancer. The ERR at 100 mGy was -0.43 (95%CI -1.11, 0.24; n = 160) for leukemia other than chronic lymphocytic leukemia (CLL), -0.06 (95%CI -0.16, 0.04; n = 3043) for ischemic heart disease (IHD), and 0.29 (95%CI 0.02, 0.55; n = 106) for esophageal cancer. Among the 6499 workers with measurable intakes of plutonium, an increase in bone cancer (SMR 2.44; 95%CI 0.98, 5.03; n = 7) was related to dose. The SMR for berylliosis was significantly high, based on 4 deaths. SMRs for Hispanic workers were significantly high for cancers of the stomach and liver, cirrhosis of the liver, nonmalignant kidney disease and diabetes, but the excesses were not related to radiation dose. There was little evidence that radiation increased the risk of lung cancer or leukemia. Esophageal cancer was associated with radiation, and plutonium intakes were linked to an increase of bone cancer. IHD was not associated with radiation dose. More precise evaluations will await the pooled analysis of workers with similar exposures such as at Rocky Flats, Savannah River and Hanford.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Muon trackers for imaging a nuclear reactor

A detector system for assessing damage to the cores of the Fukushima Daiichi nuclear reactors by using cosmic-ray muon tomography was developed. Furthermore, the system consists of a pair of drift-tube tracking detectors of 7.2× 7.2-m 2 area. In each muon tracker there consists 6 x-layer and 6 y-layer drift-tube detectors. Each tracker is capable of measuring muon tracks with 12 mrad angular resolutions, and is capable of operating under 50-μ Sv/h radiation environment by removing gamma induced background with a novel time-coincidence logic. An estimated resolution to observe nuclear fuel debris at Fukushima Daiichi is 0.3 m when the core is imaged from outside the reactor building.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗