Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Ultrafast Photoluminescence from the Core and the Shell in CdSe/CdS Dot‐in‐Rod Heterostructures

Abstract With an ultrafast time‐resolved photoluminescence system utilizing a Kerr gate, the time‐resolved photoluminescence of core and shell constituents within CdSe/CdS dot‐in‐rod heterostructures is studied as a function of heterostructure size. Measurements performed at low excitation fluence generating, on average, less than one exciton per nanorod, reveal photoluminescence from direct recombination of carriers in the CdS heterostructure rod with lifetime generally increasing from 0.4 ps to 1.3 ps as the rod length increases. Decay of the CdS rod photoluminescence is accompanied by an increase in emission from the CdSe core on comparable time scales, also trending towards larger values as the rod length increases. The observed kinetics can be explained without invoking a non‐radiative trapping mechanism. We also present alloying as a mechanism for enhancing electron confinement and reducing fluorescence lifetime at nanosecond time scales.

Diroll, Benjamin T.↗

Heat transfer study on the beamline for an electron–ion collider at BNL

This study aims to calculate thermal loads that arise as a consequence of the beamline connecting the cold (2 K) region to the ambient. Heat loads are evaluated by numerical analysis and the findings are supported by analytical calculations. An active heat intercept is proposed to mitigate heat movement to the cold end. Owing to unfavorable length-to-depth ratio and large temperature differences, it is found that radiation becomes a dominant mode of heat transfer. The presence of bellows on the beamline complicates the thermal study which is heavily dependent on geometry. An analytical framework is set up to simplify the coupled conduction–radiation problem and is shown to decrease simulation times by an order of magnitude. The study finds that the total heat moving by conduction to the cold end is around 13 W and via radiation is 1.8 W. Furthermore, the active cooling circuit under present conditions has the ability to intercept between 8 - 12 W of heat.

43 PARTICLE ACCELERATORS↗

Ultrashort high quality electron beam from laser wakefield accelerator using two-step plasma density profile

In this paper, we first use the rf linac injector mechanism to generate ultrashort high quality electron beam from laser wakefield accelerator (LWFA) with two-step plasma density profile successfully. We incorporate the physics principle in the conventional rf linac injector into the LWFA by using two-step plasma density to decrease the wavelength of the wakefield in plasma. Using this mechanism, we observe a ultrashort high quality electron beam (the rms energy spread is 1.9%, and the rms bunch length is 2 fs) in the simulation. The ultrashort intense terahertz coherent radiation (200 MW, 2 fs) can be generated with the proposed laser wakefield accelerator.

43 PARTICLE ACCELERATORS↗

Sub-Alfvenic velocity limits in magnetohydrodynamic rotating plasmas

Magnetized plasmas in shaped fields rely on large, supersonic rotation to effect centrifugal confinement of plasma along magnetic field lines. The results of experiments on the Maryland Centrifugal Experiment (MCX) [R. F. Ellis et al., Phys. Plasmas 12, 055704 (2005)] to document velocity limits are reported. Previous results have shown a limit at the Alfven speed, consistent with equilibrium limits from ideal magnetohydrodynamic theory. Another speed limit, previously reported as possibly related to a critical ionization phenomenon and depending only on the ion species and the shape of the confining magnetic field, is investigated here for a broad range of the applied parameters. We show that this speed limit manifests at sub-Alfvenic levels and that, as externally applied torques on the plasma are increased, the extra momentum input shows up as enhanced plasma density or lower momentum confinement time, accompanied by an increase in the neutral radiation level. Several key parameters are scanned, including the mirror ratio, the length between insulators, and the species mass. We show that this velocity limit is consistent with the species-dependent critical ionization velocity postulated by Alfven.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosis of femtosecond plasma filament by channeling microwaves along the filament

We introduce a simple, fast, and non-intrusive experimental method to obtain the basic parameters of femtosecond laser-generated plasma filament. The method is based on the channeling of microwaves along both a plasma filament and a well-defined conducting wire. By comparing the detected microwaves that propagate along the plasma filament and a copper wire with known conductivity and spatial dimension, the basic parameters of the plasma filament can be easily obtained. As a result of the possibility of channeling microwave radiation along the plasma filament, we were then able to obtain the plasma density distribution along the filament length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bayesian soft X-ray tomography using non-stationary Gaussian Processes

In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, development, and acceleration trials of radio-frequency quadrupole

A deuteron radio frequency quadrupole (RFQ) accelerator has been designed, fabricated, and tested at BARC, which will be used for neutron generation. The RFQ operates at a frequency of 350 MHz and needs an inter-vane voltage of 44 kV to accelerate the deuteron beam to 400 keV within a length of 1.03 m. The error analysis shows that the offset of two opposite vanes in the same direction by 100 μm leads to a change in resonant frequency by 1.3 MHz and a significant change of fields in the quadrants (∼±40% with respect to average field). From the 3D analysis, we have observed that the unwanted dipole mode frequencies are very near to the quadrupole mode frequency which will make structure sensitive to the perturbations. In order to move the dipole modes away from the quadrupole modes, we have used the dipole stabilizer rods. The 5 wire transmission line theory was used to study the perturbative analysis of the RFQ and based on this a computer program has been written to tune the cavity to get required field distribution. Based on these studies, a 1.03 m long RFQ made of OFE copper has been fabricated and tested. Even though the RFQ was designed for deuteron (D{sup +}) beam, we tested it by accelerating both the proton (H{sup +}) and D{sup +} beams. The RFQ was operated in pulsed mode and accelerated both H{sup +} and D{sup +} beams to designed values of 200 and 400 keV, respectively. The measured parameters are in good agreement with the designed values validating our simulations and fabrication processes. In this paper, simulations, RF measurements, and beam commissioning results are presented.

43 PARTICLE ACCELERATORS↗

Coherence of a spin-polarized electron beam emitted from a semiconductor photocathode in a transmission electron microscope

The brightness and interference fringes of a spin-polarized electron beam extracted from a semiconductor photocathode excited by laser irradiation are directly measured via its use in a transmission electron microscope. The brightness was 3.8 × 10{sup 7 }A cm{sup −2 }sr{sup −1} for a 30-keV beam energy with the polarization of 82%, which corresponds to 3.1 × 10{sup 8 }A cm{sup −2 }sr{sup −1} for a 200-keV beam energy. The resulting electron beam exhibited a long coherence length at the specimen position due to the high parallelism of (1.7 ± 0.3) × 10{sup −5 }rad, which generated interference fringes representative of a first-order correlation using an electron biprism. The beam also had a high degeneracy of electron wavepacket of 4 × 10{sup −6}. Due to the high polarization, the high degeneracy and the long coherence length, the spin-polarized electron beam can enhance the antibunching effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stopping potential and ion beamlet control for micro-resistive patterning through sub-Debye length plasma apertures

Focused multiple ion beamlets from a microwave plasma source is investigated for localized micron-scale modification of substrates in a patterned manner. Plasma electrodes (PE) with an array of through apertures having aperture diameters of the order of plasma Debye length are investigated for generating the beamlets. Extraction through sub-Debye length apertures becomes possible when the PE is kept at floating potential. It is found that the current – voltage characteristics of the extracted beamlets exhibits interesting features such as a space-charge-limited region that has a different behaviour than the conventional Child-Langmuir’s law and an extraction-voltage-limited region that does not undergo saturation but exhibits a Schottky-like behaviour similar to that of a vacuum diode. A switching technique to control the motion of individual beamlets is developed and the stopping potential determined. The beamlets are thereafter used to create localized micro-resistive patterns. The experimental results are compared with simulations and reasonably good agreement is obtained.

36 MATERIALS SCIENCE↗

Near-ultraviolet micro-Raman study of diamond grown on GaN

Ultraviolet (UV) micro-Raman measurements are reported of diamond grown on GaN using chemical vapor deposition. UV excitation permits simultaneous investigation of the diamond (D) and disordered carbon (DC) comprising the polycrystalline layer. From line scans of a cross-section along the diamond growth direction, the DC component of the diamond layer is found to be highest near the GaN-on-diamond interface and diminish with characteristic length scale of ∼3.5 μm. Transmission electron microscopy (TEM) of the diamond near the interface confirms the presence of DC. Combined micro-Raman and TEM are used to develop an optical method for estimating the DC volume fraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray optics testing beamline 1-BM at the advanced photon source

Beamline 1-BM at the APS has been reconfigured in part for testing of synchrotron optics with both monochromatic and white beams. Operational since 2013, it was reconfigured to accommodate users of the APS as well as users from other DOE facilities. Energies between 6 and 28 keV are available. The beamline was reconfigured to remove two large mirrors and to provide a 100 mm wide monochromatic beam at 54 m from the source. In addition a custom white beam shutter was implemented for topography exposures as short as 65 millisec over the full available horizontal width. Primary agendas include both white beam and monochromatic beam topography, Talbot grating interferometry, and tests of focusing optics. K-B mirrors, MLLs, and FZPs have been characterized. Measurements of the spatial coherence lengths on the beamline were obtained with Talbot interferometry. Topography data has been reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterising the large coherence length at diamond’s beamline I13L

I13 is a 250 m long hard x-ray beamline (6 keV to 35 keV) at the Diamond Light Source. The beamline comprises of two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques [1]. An outstanding feature of the coherence branch, due to its length and a new generation of ultra-stable beamline instrumentation [2], is its capability of delivering a very large coherence length well beyond 200 μm, providing opportunities for unique x-ray optical experiments. In this paper we discuss the challenges of measuring a large coherence length and present quantitative measurement based on analyzing diffraction patterns from a boron fiber [3]. We also discuss the limitations of this classical method in respect to detector performance, very short and long coherence lengths. Furthermore we demonstrate how a Ronchi grating setup [4] can be used to quickly establish if the beam is coherent over a large area.

43 PARTICLE ACCELERATORS↗

Decoherence and dephasing errors caused by the dc Stark effect in rapid ion transport

We investigate the error due to the dc Stark effect for quantum information processing for trapped ion quantum computers using the scalable architecture proposed in D. Wineland et al. [J. Res. Natl. Inst. Stand. Technol. 103, 259 (1998)] and D. Kielpinski et al. [Nature (London) 417, 709 (2002)]. As the operational speed increases, dephasing and decoherence due to the dc Stark effect become prominent as a large electric field is applied for rapidly transporting ions. We estimate the relative significance of the decoherence and dephasing effects and find that the latter is dominant. We find that the minimum possible dephasing is quadratic in the length of a trap and an inverse cubic in the operational time scale. From these relations, we obtain the operational speed range at which the shifts, caused by the dc Stark effect, are no longer negligible, no matter on which trajectory the ion is transported. Without phase correction, the shortest time a qubit can be transferred across a 100-micrometer-long trap, without excessive error, is about 10 ns for a {sup 40}Ca{sup +} ion and 50 ps for a {sup 9}Be{sup +} ion. In practice, the accumulated error is difficult to track and to calculate; thus, our paper gives an estimate for the range of the speed limit imposed by the dc Stark effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam dynamics in a storage ring with a free-electron laser

In this paper, we study the dynamics of the electron beam in a diffraction limited storage ring with a high-gain free-electron laser. We present in detail the design, including lattice, dynamic aperture, intrabeam scattering, and coherent synchrotron radiation. The simulation of the electron storage ring combined with the free-electron laser is carried out until the electron beam reaches its equilibrium. We find that the initial exponential radiation power is reduced approximately to linear with respect to the undulator length due to the large increase of the energy spread from the free-electron laser.

43 PARTICLE ACCELERATORS↗

Dose equations for shift-variant CT acquisition modes using variable pitch, tube current, and aperture, and the meaning of their associated CTDI{sub vol}

Purpose: With the increasing clinical use of shift-variant CT protocols involving tube current modulation (TCM), variable pitch or pitch modulation (PM), and variable aperture a(t), the interpretation of the scanner-reported CTDI{sub vol} is called into question. This was addressed for TCM in their previous paper published by Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)] and is extended to PM and concurrent TCM/PM as well as variable aperture in this work. Methods: Rigorous convolution equations are derived to describe the accumulated dose distributions for TCM, PM, and concurrent TCM/PM. A comparison with scanner-reported CTDI{sub vol} formulae clearly identifies the source of their differences with the traditional CTDI{sub vol}. Dose distribution simulations using the convolution are provided for a variety of TCM and PM scenarios including a helical shuttle used for perfusion studies (as well as constant mA)—all having the same scanner-reported CTDI{sub vol}. These new convolution simulations for TCM are validated by comparison with their previous discrete summations. Results: These equations show that PM is equivalent to TCM if the pitch variation p(z) is proportional to 1/i(z), where i(z) is the local tube current. The simulations show that the local dose at z depends only weakly on the local tube current i(z) or local pitch p(z) due to scatter from all other locations along z, and that the “local CTDI{sub vol}(z)” or “CTDI{sub vol} per slice” do not represent a local dose but rather only a relative i(z) or p(z). The CTDI-paradigm does not apply to shift-variant techniques and the scanner-reported CTDI{sub vol} for the same lacks physical significance and relevance. Conclusions: While the traditional CTDI{sub vol} at constant tube current and pitch conveys useful information (the peak dose at the center of the scan length), CTDI{sub vol} for shift-variant techniques (TCM or PM) conveys no useful information about the associated dose distribution it purportedly represents. On the other hand, the total energy absorbed E (“integral dose”) as well as its surrogate DLP remain robust (invariant) with respect to shift-variance, depending only on the total mAs = 〈i〉t{sub 0} accumulated during the total beam-on time t{sub 0} and aperture a, where 〈i〉 is the average current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cluster structure of a low-energy resonance in tetraneutron

We theoretically investigate the possibility for a tetraneutron to exist as a low-energy resonance state. We explore a microscopic model based on the assumption that the tetraneutron can be treated as a compound system, where {sup 3}n + n and {sup 2}n + {sup 2}n coupled cluster configurations coexist. The influence of the Pauli principle on the kinetic energy of the relative motion of the neutron clusters is shown to result in their attraction. The strength of such attraction is high enough to ensure the existence of a low-energy resonance in the tetraneutron, provided that the oscillator length is large enough.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Asymptotic Limits for Transport in Binary Stochastic Mixtures

The Karhunen-Loeve stochastic spectral expansion of a random binary mixture of immiscible fluids in planar geometry is used to explore asymptotic limits of radiation transport in such mixtures. Under appropriate scalings of mixing parameters - correlation length, volume fraction, and material cross sections - and employing multiple- scale expansion of the angular flux, previously established atomic mix and diffusion limits are reproduced. When applied to highly contrasting material properties in the small cor- relation length limit, the methodology yields a nonstandard reflective medium transport equation that merits further investigation. Finally, a hybrid closure is proposed that produces both small and large correlation length limits of the closure condition for the material averaged equations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

I Would Like to Know... [Slides]

Problems of High-Energy Physics (NAL Design Report, January 1968) We would like to have answers to many questions. Among them are the following: Which, if any, of the particles that have so far been discovered, is, in fact, elementary, and is there any validity in the concept of “elementary” particles? What new particles can be made at energies that have not yet been reached? Is there some set of building blocks that is still more fundamental than the neutron and the proton? Is there a law that correctly predicts the existence and nature of all the particles, and if so, what is that law? Will the characteristics of some of the very short-lived particles appear to be different when they are produced at such higher velocities that they no longer spend their entire lives within the strong influence of the particle from which they are produced? Do new symmetries appear or old ones disappear for high momentum-transfer events? What is the connection, if any, of electromagnetism and strong interactions? Do the laws of electromagnetic radiation, which are now known to hold over an enormous range of lengths and frequencies, continue to hold in the wavelength domain characteristic of the subnuclear particles? What is the connection between the weak interaction that is associated with the massless neutrino and the strong one that acts between neutron and proton? Is there some new particle underlying the action of the “weak” forces, just as, in the case of the nuclear force, there are mesons, and, in the case of the electromagnetic force, there are photons? If there is not, why not? In more technical terms: Is local field theory valid? A failure in locality may imply a failure in our concept of space. What are the fields relevant to a correct local field theory? What are the form factors of the particles? What exactly is the explanation of the electromagnetic mass difference? Do “weak” interactions become strong at sufficiently small distances? Is the Pomeranchuk theorem true? Do the total cross sections become constant at high energy? Will new symmetries appear, or old ones disappear, at higher energy?

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗