Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Shape polarization in the tin isotopes near N = 60 from precision g-factor measurements on short-lived 11/2 - isomers

The g factors of 11/2 - isomers in semimagic 109 Sn and 111 Sn (isomeric lifetimes $\tau$ = 2.9(3) ns and $\tau$ = 14.4(7) ns, respectively) were measured by an extension of the Time Differential Perturbed Angular Distribution technique, which uses LaBr3 detectors and the hyperfine fields of a gadolinium host to achieve precise measurements in a new regime of short-lived isomers. The results, g(11/2 - ; 109 Sn) = -0.186(8) and g(11/2 - ; 111 Sn) = -0.214(4), are significantly lower in magnitude than those of the 11/2 - isomers in the heavier isotopes and depart from the value expected for a near pure neutron h 11/2 configuration. Broken-symmetry density functional theory calculations applied to the sequence of 11/2 - states reproduce the magnitude and location of this deviation. The g(11/2 - ) values are affected by shape core polarization; the odd Oh 11/2 neutron couples to J π = 2 + , 4 + , 6 + ... configurations in the weakly-deformed effective core, causing a decrease in the g-factor magnitudes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Small Scattering Angle Measurements of Proton–Proton and Proton–Nucleus Analyzing Powers at the RHIC Hydrogen Jet Polarimeter

At RHIC, the hydrogen jet target polarimeter (HJET) is used to measure proton beam polarization with accuracy $σ^{syst}_{P}$ / $P$ ≲ 0.5% by counting low energy (1–10 MeV) recoil protons in left-right symmetric detectors. The HJET performance also allowed us to precisely measure $pp$ and $pA$ (where $A$ is any ion stored at RHIC) analyzing powers in the CNI region. The results of the measurements are discussed.

43 PARTICLE ACCELERATORS↗

Smallness of matter effects in long-baseline muon neutrino disappearance

Current long-baseline accelerator experiments, NOvA and T2K, are making excellent measurements of neutrino oscillations and the next generation of experiments, DUNE and HK, will make measurements at the O ( 1 % ) level of precision. These measurements are a combination of the appearance channel which is more challenging experimentally but depends on many oscillation parameters, and the disappearance channel which is somewhat easier and allows for precision measurements of the atmospheric mass splitting and the atmospheric mixing angle. It is widely recognized that the matter effect plays a key role in the appearance probability, yet the effect on the disappearance probability is surprisingly small for these experiments. Here we investigate both exactly how small the effect is and show that it just begins to become relevant in the high statistics regime of DUNE. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Precision Penning Trap Measurements of beta-decay Q-values for Neutrino Physics

The 2015 Nobel Prize in physics was awarded to Takaaki Kajita and Arthur B. McDonald “for the discovery of neutrino oscillations, which shows that neutrinos have mass”. This fact has wide reaching implications for the standard model of particle physics, nuclear physics, and cosmology. However, important fundamental questions remain: What is the absolute neutrino mass scale? Is the neutrino a Majorana or a Dirac particle? A number of large-scale experiments are underway or are being developed to attempt to answer these questions. Two classes of experiments are direct neutrino mass determination experiments, and searches for neutrinoless double betadecay. This work aimed to aid these experiments via high-precision Q value determinations for the relevant isotopes using Penning trap mass spectrometry (PTMS).

42 ENGINEERING↗

Development of a rapid-transit system for precision nuclear physics measurements

A Rapid Belt-driven Irradiated Target Transfer System, named RABITTS, was developed for use at the Triangle Universities Nuclear Laboratory. This system allows for cyclic activation with neutron or photon beams, and measurement of reaction products using γ-ray spectroscopy. Both a 1 meter and 10 meter transfer system have been developed with transit times as low as 0.4 and 1.0 seconds, respectively. The systems are deployed at the tandem accelerator laboratory for use with monoenergetic neutron beams, and at the High-Intensity γ-ray Source facility for activation using photon beams. A detailed characterization of the systems’ performance and sensitivity is presented. In order to produce the highest accuracy cross-section data, a model for calculating corrections to cyclic activation with variable beam flux is developed and presented. We have commissioned these systems by measuring 197m Au, where we report a measured half-life of 7.73 ± 0.05 s and a 197 Au(n, n') 197m Au isomer production cross of 628 ± 28 mb at neutron energy E n = 2.0 MeV. In addition, we measured 90m Zr, where we report a measured half-life of 799.7 ± 8.0 ms and a 90 Zr(n, n') 90m Zr isomer production cross of 180 ± 12 mb at E n = 4.6 MeV. Furthermore, these measured half-lives are in excellent agreement with the evaluated values and the cross-section measurements are performed at previously unmeasured incident neutron energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Development of a direct-sampling RF receiver for precision beam charge measurements in the MOLLER experiment

Here, we have developed and tested a direct-sampling RF receiver capable of measuring the amplitude of a 1497 MHz sinusoidal beam signal in 0.5 ms integration windows with a relative uncertainty of better than 10 parts per million. The receiver is intended for measuring signals from beam current monitoring cavities on the beamline of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. The beam signal strength, frequency, and integration window fulfill the thus far unmet requirements of the upcoming MOLLER experiment to measure the beam charge for different helicity states.

47 OTHER INSTRUMENTATION↗

Methods for Precision Studies of Neutrino Interactions

Accelerator neutrino oscillation experiments provide a sensitive way to investigatea number of major open questions in neutrino physics. To achieve precision neutrinooscillation measurements, we need a good understanding of key aspects of the experiments,such as the detection technologies used and neutrino interactions at few-GeV energies.The MicroBooNE experiment has advanced the development of technologies for LArTPCs.An ultra-violet laser system was introduced to MicroBooNE in order to measure theelectric field in situ, which plays a central role in the formation of charge and lightsignals in LArTPCs. This thesis describes the setup and operation of the laser system. Ideveloped a general methodology to measure the electric field and the consequent spatialdistortion in LArTPCs, which supports precision measurements in accelerator neutrinooscillation experiments. In MicroBooNE, the measured electric field distortions are upto 15 ± 3 % with respect to the nominal value, and the measured spatial distortions areup to 15 ± 3 cm. The result of the electric field measurement is applied to the detectorsimulation and the event reconstruction, which leads to a better detector characterizationfor neutrino analyses. A significant concern for measurements of neutrino interactions ismodel dependence, as the currently available models are not sufficient for describing thepicture of neutrino interacting at few-GeV energies. In this thesis, I developed a detailedstrategy for a model-independent cross-section measurement at low energy transfers,where the available model predictions do not agree with the inclusive measurementsfrom multiple experiments. A likelihood fit technique for cross-section extraction isrealized in an accelerator neutrino experiment using a LArTPC for the first time. Thetreatment of systematic uncertainties developed in this thesis is generally applicable foranalyses using similar fitting techniques. This neutrino interaction study at low energytransfers provides a probe to the poorly understood region of neutrino cross sections. Themeasurement scheme developed here aims to guide future model-independent cross-sectionmeasurements, particularly for neutrino experiments using LArTPCs.

Chen, Yifan↗

Precise $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd with the Canadian Penning trap for evaluation of potential ultralow $\textit{Q}$-value $\textit{β}$ decays

Background: An ultralow $\textit{Q}$-value $\textit{β}$ decay can occur from a parent nuclide to an excited nuclear state in the daughter such that $Q_{\text{UL}}$ 1 keV. These decay processes are of interest for nuclear $\textit{β}$-decay theory and as potential candidates in neutrino mass determination experiments. To date, only one ultralow $\textit{Q}$-value $\textit{β}$ decay has been observed—that of 115 In with $Q_β$ = 147(10) eV. A number of other potential candidates exist, but improved mass measurements are necessary to determine if these decay channels are energetically allowed and, in fact, ultralow. Purpose: To perform precise $\textit{β}$-decay $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd and to use them in combination with nuclear energy level data for the daughter isotopes 112,113 Cd and 115 In to determine if the potential ultralow $\textit{Q}$-value $\textit{β}$-decay branches of 112,113 Ag and 115 Cd are energetically allowed and 1 keV. Method: The Canadian Penning Trap at Argonne National Laboratory was used to measure the cyclotron frequency ratios of singly charged 112,113 Ag and 115 Cd ions with respect to their daughters 112,113 Cd and 115 In. From these measurements, the ground-state to ground-state $\textit{β}$-decay $\textit{Q}$ values were obtained. Results: The 112 Ag → 112 Cd, 113 Ag → 113 Cd, and 115 Cd → 115 In $\textit{β}$-decay $\textit{Q}$ values were measured to be $Q_β$( 112 Ag) = 3990.16(22) keV, $Q_β$( 113 Ag) = 2085.7(4.6) keV, and $Q_β$( 115 Cd) = 1451.36(34) keV. These results were compared to energies of excited states in 112 Cd at 3997.75(14) keV, 113 Cd at 2015.6(2.5) and 2080(10) keV, and 115 In at 1448.787(9) keV, resulting in precise $Q_{\text{UL}}$ values for the potential decay channels of –7.59(26) keV, 6(11) keV, and 2.57(34) keV, respectively. Conclusion: The potential ultralow $\textit{Q}$-value decays of 112 Ag and 115 Cd have been ruled out. 113 Ag is still a possible candidate until a more precise measurement of the 2080(10) keV, 1/2+ state of 113 Cd is available. In the course of this work we have found the ground state mass of 113 Ag reported in the 2020 Atomic Mass Evaluation [Wang et al., Chin. Phys. C 45, 030003 (2021)] to be lower than our measurement by 69(17) keV (a 4σ discrepancy).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Kinematic Sunyaev--Zel'dovich Measurements Across Halo Mass and Redshift with DESI DR2 and ACT DR6: Part I. Luminous Red Galaxies

We present the most precise measurements of the kinetic Sunyaev-Zel'dovich (kSZ) effect around luminous red galaxies to date, detecting the signal at $18σ$ significance in both harmonic and configuration space. Our analysis cross-correlates 2.4 million spectroscopic LRGs from the Dark Energy Spectroscopic Instrument (DESI) DR2 sample with Data Release 6 (DR6) of the Atacama Cosmology Telescope (ACT). We develop a novel harmonic-space cross-correlation approach using momentum-weighted kSZ templates, yielding nearly uncorrelated bandpowers within a framework consistent with other large-scale structure analyses. By incorporating the LRG halo occupation distribution (HOD) and its uncertainty, we convert measured galaxy gas profiles into halo gas profiles and provide generalized Navarro-Frenk-White (GNFW) fitting profiles, providing empirical targets for tuning feedback efficiency in hydrodynamical simulations and for baryonic modeling in large-scale structure analyses. We find strong evidence that gas profiles do not trace dark matter, providing direct evidence for gas redistribution beyond gravitational collapse. Comparing to hydrodynamical simulations, our measurements favor feedback efficiencies exceeding those in the Battaglia profile, suggesting more efficient gas ejection in group-scale halos than previously predicted. Splitting by redshift, we detect the kSZ signal at SNR $\approx 5$--$10$ in each of four bins and find amplitude evolution consistent with the expected decline in mean halo mass at fixed comoving number density. Splitting by stellar mass, we study the scaling of kSZ amplitude with galaxy properties. Together with BGS and ELG measurements in Paper II, these results span $0.1 \lesssim z \lesssim 1.6$ across three galaxy populations, demonstrating the potential of spectroscopic kSZ to map circumgalactic gas and constrain baryonic feedback.

Qu, F. J. [KIPAC, Menlo Park; Stanford U., HEPL; S↗

Trigonometric Parallaxes of Two T Dwarfs With Keck and ShaneAO Astrometry

We present trigonometric parallax and proper motion measurements for two T-type brown dwarfs. We derive our measurements from infrared laser guide star adaptive optics observations spanning five years from the ShaneAO/SHARCS and NIRC2/medium-cam instruments on the Shane and Keck telescopes, respectively. To improve our astrometric precision, we measure and apply a distortion correction to our fields for both instruments. We also transform the Keck and ShaneAO astrometric reference frames onto the ICRS using five-parameter parallax and proper motion solutions for background reference stars from Gaia DR2. Fitting for parallax and proper motion, we measure parallaxes of 73.5 ± 9.2 mas and 70.1 ± 6.7 mas for WISEJ19010703+47181688 (WISE1901) and WISEJ21543294+59421370 (WISE2154), respectively. We utilize Monte Carlo methods to estimate the error in our sparse field methods, taking into account overfitting and differential atmospheric refraction. Comparing to previous measurements in the literature, all of our parallax and proper motion values fall within 2σ of the published measurements, and 4 of 6 measurements are within 1σ. These data are among the first parallax measurements of these T dwarfs and serve as precise measurements for calibrating stellar formation models. These two objects are the first results of an ongoing survey of T dwarfs with Keck/NIRC2 and the Shane Adaptive Optics system at Lick Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Report of the Topical Group on Higgs Physics for Snowmass 2021: The Case for Precision Higgs Physics

A future Higgs Factory will provide improved precision on measurements of Higgs couplings beyond those obtained by the LHC, and will enable a broad range of investigations across the fields of fundamental physics, including the mechanism of electroweak symmetry breaking, the origin of the masses and mixing of fundamental particles, the predominance of matter over antimatter, and the nature of dark matter. Future colliders will measure Higgs couplings to a few per cent, giving a window to beyond the Standard Model (BSM) physics in the 1-10 TeV range. In addition, they will make precise measurements of the Higgs width, and characterize the Higgs self-coupling. Here, this report details the work of the EF01 and EF02 working groups for the Snowmass 2021 study.

Dawson, Sally↗

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the 𝑁 = 28 shell closure

Although it is known that the N = 28 spherical shell closure erodes, the strength of the closure with decreasing proton number Z < 20 is an open question in nuclear structure. Here, in this region of interest, high-precision mass measurements of neutron-rich 43-45 Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME(⁴³Cl) = -24114.4(1.7) keV, ME(⁴⁴Cl) = -20450.8(10.6) keV, and ME(⁴⁵Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ∼40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to ab initio calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Erington, H. [Michigan State Univ., East Lansing, ↗

Precise interpretations of traditional fine-tuning measures

We uncover two precise interpretations of traditional electroweak fine-tuning (FT) measures that were historically missed. (i) a statistical interpretation : the traditional FT measure shows the change in plausibility of a model in which a parameter was exchanged for the 𝑍 boson mass relative to an untuned model in light of the 𝑍 boson mass measurement. (ii) an information-theoretic interpretation : the traditional FT measure shows the exponential of the extra information, measured in nats, relative to an untuned model that you must supply about a parameter in order to fit the 𝑍 mass. We derive the mathematical results underlying these interpretations, and explain them using examples from weak scale supersymmetry. These new interpretations allow us to rigorously define FT in particle physics and beyond, shed fresh light on the status of extensions to the Standard Model and, lastly, allow us to precisely reinterpret historical and recent studies using traditional FT measures.

electroweak symmetry breaking↗

First direct 7 Be electron-capture $\mathrm{Q}$-value measurement toward high-precision searches for neutrino physics beyond the Standard Model

Here, we report the first direct measurement of the nuclear electron-capture (EC) decay Q value of 7 Be → 7 Li via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable 7 Be + samples. With a measured value of Q EC = 861.963(23) keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the 7 Be EC decay Q value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using 7 Be-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗