Modular HPC I/O characterization with Darshan

Contemporary high-performance computing (HPC) applications encompass a broad range of distinct I/O strategies and are often executed on a number of different compute platforms in their lifetime. These large-scale HPC platforms employ increasingly complex I/O subsystems to provide a suitable level of I/O performance to applications. Tuning I/O workloads for such a system is nontrivial, and the results generally are not portable to other HPC systems. I/O profiling tools can help to address this challenge, but most existing tools only instrument specific components within the I/O subsystem that provide a limited perspective on I/O performance. The increasing diversity of scientific applications and computing platforms calls for greater flexibililty and scope in I/O characterization.

Snyder, Shane↗

Evaluating the Computational Requirements of using SVM software to train Data-Intensive Problems

Support vector machine (SVM) technology is a growing class of computational algorithms for solving classification problems using supervised learning. There are many freely available SVM codes with implementations of varying granularity in the core optimization task. The performance of SVM implementations is related to four key elements; (1) the size and dimension of the data set on which they are operating, (2) the granularity of their core SVM optimization implementation, (3) the kernel transformation applied to the data, and the (4) underlying hardware on which the implementation is running. To assess the performance of different SVM implementations, several freely available codes representing the spectrum of optimization granularity were built on a variety of hardware—two linux clusters, and a shared memory machine. Binary classifiers were trained on datasets of varying size containing anywhere from a few hundred to over 50,000 vectors. Performance of the methods was measured in terms of wall-clock time for training, statistical quality of the resulting classifier, hardware performance (memory footprint, memory bandwidth, floating point unit usage, I/O bandwidth, and instruction stalls), robustness and portability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis

The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector), ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights on the extraordinary tolerance to alcohols of Fe-N-C cathode catalysts in highly performing direct alcohol fuel cells

Direct alcohol fuel cells (DAFCs) represent the best alternative to batteries for portable and auxiliary power units application due to the high energy density of short chain alcohols. Currently, the utilization of the best platinum group metal (PGM) cathode catalysts is limited, not only by a high cost and scarce resources, but also by the inefficient oxygen reduction reaction (ORR) when permeated alcohols adsorb on the catalytic active sites. In this work, a highly active Fe-N-C catalyst derived from the pyrolysis of nicarbazin (a nitrogen charge transfer organic salt) and an iron precursor has been investigated to get insights on the extraordinary tolerance to the presence of alcohols (methanol and ethanol) of such a PGM-free catalyst. Density functional theory (DFT) calculations demonstrate for the first time that Fe-N 4 and Fe-N 2 C 2 active sites preferentially adsorb oxygen with much higher energy than methanol, ethanol and products of partial ethanol oxidation (0.73–1.16 eV stronger adsorption), while nitrogen-carbon related sites (pyridinic and graphitic nitrogen) are much less selective towards ORR. Half-cell electrochemical characterization showed that the Fe-N-C catalyst overcomes Pt ORR activity in acidic medium with methanol or ethanol concentrations as low as 0.01 M. The feasibility of DAFCs operation based on high methanol (up to 17 M) and ethanol (up to 5 M) concentration thanks to the utilization of Fe-N-C cathode catalyst is demonstrated. Lastly, a new strategy is proposed for DAFCs where using Pt only at the anode and Fe-N-C at the cathode allows extending the device energy density compared to PGM-based catalysts at both electrodes.

30 DIRECT ENERGY CONVERSION↗

Estimating gas concentration using a microcantilever-based electronic

This paper investigates the determination of the concentration of a chemical vapor as a function of several nonspecific microcantilever array sensors. The nerve agent dimethyl methyl phosphonate (DMMP) in parts-per-billion concentrations in binary and ternary mixtures is able to be resolved when present in a mixture containing parts-per-million concentrations of water and ethanol. The goal is to not only detect the presence of DMMP, but additionally to map the nonspecific output of the sensor array onto a concentration scale. We investigate both linear and nonlinear approaches the linear approach uses a separate least-squares model for each component, and a nonlinear approach which estimates the component concentrations in parallel. Application of both models to experimental data indicate that both models are able to produce bounded estimates of concentration, but that the outlier performance favors the linear model. The linear model is better suited to portable handheld analyzer, where processing and memory resources are constrained.

electronic nose↗

The relationships between residual stress relaxation and texture development in AZ31 Mg alloys via the vibratory stress relief technique

A systematic study of residual stress relaxation and the texture evolution of cold-rolled AZ31 Mg alloys using the vibratory stress relief technique with a simple cantilever beam vibration system was performed using a high-resolution X-ray diffractometer and a portable X-ray residual stress analyzer. The effects of vibrational stress excitation on the surface residual stress distribution and on the texture of pole figures (0002) occurring during the vibratory stress relief were examined. Compared with the effects corresponding to the same alloy under non-vibration condition, it can be observed that the uniform surface residual stress distribution and relaxation of the compressive residual stress in the stress concentration zone were observed rather than all of the residual stresses being eliminated. Furthermore, with an increase in the vibrational aging time, the compressive residual stress, texture density, and (0002) preferred orientation increased first and then decreased. It should be underlined that the vibratory stress relief process for the vibrational aging time of more than 10 min is able to weaken the strong basal textures of AZ31 Mg alloys, which is valuable for enhancement of their formability and is responsible for an almost perfect 3D-Debye–Scherrer ring. - Highlights: • 3D-Debye ring about VSR technique is not discussed in the existing literature. • A newly developed VSR method is suitable for small or thin workpieces. • The cosα method accurately and effectively determines the residual stresses. • The VSR technique is valuable for enhancement of their formability. • The texture and preferred orientation change with the vibrational aging time.

36 MATERIALS SCIENCE↗

Rapid response sensor for analyzing Special Nuclear Material

Rapid in-situ analytical techniques are attractive for characterizing Special Nuclear Material (SNM). Present techniques are time consuming, and require sample dissolution. Proof-of-principal studies are performed to demonstrate the utility of employing low energy neutrons from a portable pulsed neutron generator for non-destructive isotopic analysis of nuclear material. In particular, time-sequenced data acquisition, operating synchronously with the pulsing of a neutron generator, partitions the characteristic elemental prompt gamma-rays according to the type of the reaction; inelastic neutron scattering reactions during the ON state and thermal neutron capture reactions during the OFF state of the generator. Thus, the key challenge is isolating these signature gamma- rays from the prompt fission and β-delayed gamma-rays that are also produced during the neutron interrogation. A commercial digital multi-channel analyzer has been specially customized to enable time-resolved gamma-ray spectral data to be acquired in multiple user-defined time bins within each of the ON/OFF gate periods of the neutron generator. Preliminary results on new signatures from depleted uranium as well as modeling and benchmarking of the concept are presented, however this approach should should be applicable for virtually all forms of SNM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional bicontinuous ultrafast-charge and -discharge bulk battery electrodes

Rapid charge and discharge rates have become an important feature of electrical energy storage devices, but cause dramatic reductions in the energy that can be stored or delivered by most rechargeable batteries (their energy capacity). Supercapacitors do not suffer from this problem, but are restricted to much lower stored energy per mass (energy density) than batteries. A storage technology that combines the rate performance of supercapacitors with the energy density of batteries would significantly advance portable and distributed power technology. Furthermore, we demonstrate very large battery charge and discharge rates with minimal capacity loss by using cathodes made from a self-assembled three-dimensional bicontinuous nanoarchitecture consisting of an electrolytically active material sandwiched between rapid ion and electron transport pathways. Rates of up to 400C and 1,000C for lithium-ion and nickel-metal hydride chemistries, respectively, are achieved (where a 1C rate represents a one-hour complete charge or discharge), enabling fabrication of a lithium-ion battery that can be 90% charged in 2 minutes.

25 ENERGY STORAGE↗

High-performance zero-bias ultraviolet photodetector based on p-GaN/n-ZnO heterojunction

Lattice-match p-GaN and n-ZnO bilayers were heteroepitaxially grown on the c-sapphire substrate by metal organic chemical vapor deposition and molecular beam epitaxy technique, respectively. X-ray diffraction and photoluminescence investigations revealed the high crystal quality of the bilayer films. Subsequently, a p-GaN/n-ZnO heterojunction photodetector was fabricated. The p-n junction exhibited a clear rectifying I-V characteristic with a turn-on voltage of 3.7 V. At zero-bias voltage, the peak responsivity was 0.68 mA/W at 358 nm, which is one of the best performances reported for p-GaN/n-ZnO heterojunction detectors due to the excellent crystal quality of the bilayer films. These show that the high-performance p-GaN/n-ZnO heterojunction diode is potential for applications of portable UV detectors without driving power.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MaPPeRTrac

Massively Parallel, Portable, and Reproducible Tractography (MaPPeRTrac) is a brain tractography workflow for high performance computing. It incorporates novel technologies to simplify and accelerate neuroimaging research.

MADDURI, RAVIK↗

Massively Parallel and Portable Genomic Sequence Analysis

Massively Parallel and Portable Genomic Sequence Analysis (mappgene) is a sequencing analysis workflow for high performance computing. It incorporates novel technologies to simplify and accelerate genetics research.

Moon, Josephy↗

VerifyIO: Verifying Adherence to Parallel I/O Consistency Semantics

VerifyIO is a tool designed for verifying I/O consistency semantics in High-Performance Computing (HPC) applications. It addresses the challenges of ensuring correctness and portability across different I/O consistency models, such as POSIX, Commit, Session, and MPI-IO. By analyzing execution traces, detecting conflicts, and verifying synchronization adherence, VerifyIO provides actionable insights for both application developers and I/O library designers.

Wang, Chen [Lawrence Livermore National Laboratory↗

Improving Self-Driving Labs: Quantifying System-Level Experiment Repeatability and Broadening Instrument-Level Compatibility

Modular Autonomous Research System (MARS) is a self-driving laboratory (SDL) which performs wet-lab science with peptide-lanthanide combinations in an automated and, ultimately, an autonomous manner to aid in soil analysis for domestic lithium mining. Autonomous experimentation involves automated experimentation, experiment planning, and active learning. MARS consists of a 6-axis robotic arm (UR5e) on a linear rail, pipette robots (Opentrons 2), and microplate readers. These components transport, operate on, and collect data with chemical solutions in standard labware. For effective autonomy, MARS must perform system-level labware operations repeatably, plan experiments autonomously, and be portable between research-domains. Repeatability is evaluated by labware placement precision, such that future operations can properly locate labware, as well as the elapsed time, so that low variance mean estimates of experiment duration can inform high-level researcher decision making. Autonomous experiment planning is the next step to decouple experimentation from human management; however, there is a conflict between the ideal system-level experiment goals and the constraints imposed by instruments’ limitations. Sub-domain portability is a long-term goal to extend MARS’ research beyond the chemistry of peptide-lanthanide binding to other sub-domains without having to invest significant overhead to system retrofitting. To address these goals, we manually trained the robotic arm labware placement and modelled statistical failurerate and uncertainty Additionally, we benchmarked the duration and variance of each experiment sub-operation as a heuristic for research decision making. Next, we use a parameterized geometric program (PGP) approach to design experiments that optimize system-level objectives and satisfy instrument-level constraints. Lastly, we proposed a Python framework to maximize MARS’ extensibility to other scientific sub-domains through a JSON-based experiment specification.

36 MATERIALS SCIENCE↗

HPC Global File System Performance Analysis Using A Scientific-Application Derived Benchmark

With the exponential growth of high-fidelity sensor and simulated data, the scientific community is increasingly reliant on ultrascale HPC resources to handle its data analysis requirements. However, to use such extreme computing power effectively, the I/O components must be designed in a balanced fashion, as any architectural bottleneck will quickly render the platform intolerably inefficient. To understand I/O performance of data-intensive applications in realistic computational settings, we develop a lightweight, portable benchmark called MADbench2, which is derived directly from a large-scale Cosmic Microwave Background (CMB) data analysis package. Our study represents one of the most comprehensive I/O analyses of modern parallel file systems, examining a broad range of system architectures and configurations, including Lustre on the Cray XT3, XT4, and Intel Itanium2 clusters; GPFS on IBM Power5 and AMD Opteron platforms; a BlueGene/P installation using GPFS and PVFS2 file systems; and CXFS on the SGI Altix\-3700. We present extensive synchronous I/O performance data comparing a number of key parameters including concurrency, POSIX- versus MPI-IO, and unique-versus shared-file accesses, using both the default environment as well as highly-tuned I/O parameters. Finally, we explore the potential of asynchronous I/O and show that only the two of the nine evaluated systems benefited from MPI-2's asynchronous MPI-IO. On those systems, experimental results indicate that the computational intensity required to hide I/O effectively is already close to the practical limit of BLAS3 calculations. Overall, our study quantifies vast differences in performance and functionality of parallel file systems across state-of-the-art platforms -- showing I/O rates that vary up to 75x on the examined architectures -- while providing system designers and computational scientists a lightweight tool for conducting further analysis.

97 MATHEMATICS AND COMPUTING↗

Portable C++ Code that can Look and Feel Like Fortran Code with Yet Another Kernel Launcher (YAKL)

This paper introduces the Yet Another Kernel Launcher (YAKL) C++ portability library, which strives to enable user-level code with the look and feel of Fortran code. The intended audience includes both C++ developers and Fortran developers unfamiliar with C++. The C++ portability approach is briefly explained, YAKL’s main features are described, and code examples are given that demonstrate YAKL’s usage. YAKL fills a niche capability important particularly to scientific applications seeking to port Fortran code quickly to a portable C++ library. YAKL places heavy emphasis on simplicity, readability, and productivity with performance mainly emphasizing Graphics Processing Units (GPUs). Central to YAKL’s ability to allow Fortran-like user-level code are three features: (1) a multi-dimensional Array class that allows Fortran behavior; (2) a limited library of Fortran intrinsic functions; and (3) an efficient pool allocator that transparently enables cheap frequent allocations and deallocations of YAKL Arrays. While YAKL allows Fortran-style code, it also allows Arrays that exhibit C-like behavior as well, including row-major index ordering and lower bounds of “0”. YAKL currently supports CPUs, CPU threading, and Nvidia, AMD, and Intel GPUs.

97 MATHEMATICS AND COMPUTING↗

A Simple and Portable Multi-Channel Pyrometer allowing temperature measurements down to 800 K on the microsecond scale

The measurement of transient temperatures less than 1000 K for samples in laser-heated diamond anvil cells remains a challenge. Here we present a design and performance characteristics for a multi-channel pyrometer that works in the NIR from 1200 to 2000 nm. It has a relatively small footprint, is portable, only requires low voltage power supplies and can report temperatures down to 800 K on the millisecond scale or faster. A single data point without averaging can be acquired in 14 microseconds (sampling rate of 70'000 times/s). In conjunction with a diamond anvil cell, the system still works down to about 830 K. The pyrometer has been interfaced several times with the laser heating system at the High Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source in Chicago with good results.

Montgomery, Jeffrey M.↗

Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-673: Recent Developments and Comprehensive Validations of a GPU-Based Proton Monte Carlo Simulation Package, GPMC

Purpose: A GPU-based Monte Carlo (MC) simulation package gPMC has been previously developed and high computational efficiency was achieved. This abstract reports our recent improvements on this package in terms of accuracy, functionality, and code portability. Methods: In the latest version of gPMC, nuclear interaction cross section database was updated to include data from TOPAS/Geant4. Inelastic interaction model, particularly the proton scattering angle distribution, was updated to improve overall simulation accuracy. Calculation of dose averaged LET (LETd) was implemented. gPMC was ported onto an OpenCL environment to enable portability across different computing devices (GPUs from different vendors and CPUs). We also performed comprehensive tests of the code accuracy. Dose from electro-magnetic (EM) interaction channel, primary and secondary proton doses and fluences were scored and compared with those computed by TOPAS. Results: In a homogeneous water phantom with 100 and 200 MeV beams, mean dose differences in EM channel computed by gPMC and by TOPAS were 0.28% and 0.65% of the corresponding maximum dose, respectively. With the Geant4 nuclear interaction cross section data, mean difference of primary proton dose was 0.84% for the 200 MeV case and 0.78% for the 100 MeV case. After updating inelastic interaction model, maximum difference of secondary proton fluence and dose were 0.08% and 0.5% for the 200 MeV beam, and 0.04% and 0.2% for the 100 MeV beam. In a test case with a 150MeV proton beam, the mean difference between LETd computed by gPMC and TOPAS was 0.96% within the proton range. With the OpenCL implementation, gPMC is executable on AMD and Nvidia GPUs, as well as on Intel CPU in single or multiple threads. Results on different platforms agreed within statistical uncertainty. Conclusion: Several improvements have been implemented in the latest version of gPMC, which enhanced its accuracy, functionality, and code portability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗