Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Phase Correction for GPS Antenna with Nonunique Phase Center

A method of determining the position and attitude of a body equipped with a Global Positioning System (GPS) receiver includes an accounting for the location of the nonunique phase center of a distributed or wraparound GPS antenna. The method applies, more specifically, to the case in which (1) the GPS receiver utilizes measurements of the phases of GPS carrier signals in its position and attitude computations and (2) the body is axisymmetric (e.g., spherical or round cylindrical) and wrapped at its equator with a single- or multiple-element antenna, the radiation pattern of which is also axisymmetric with the same axis of symmetry as that of the body.

Fink, Patrick W.↗

Velocity and drop size measurements in a swirl-stabilized, combusting spray

Velocity and drop size measurements are reported for a swirl-stabilized, combusting spray. For the gas phase, three components of mean and fluctuating velocity are reported. For the droplets, three components of mean and fluctuating velocity, diameter, and number flux are reported. The liquid fuel utilized for all the tests was heptane. The fuel was injected using an air-assist atomizer. The combustor configuration consisted of a center-mounted, air-assist atomizer surrounded by a coflowing air stream. Both the coflow and the atomizing air streams were passed through 45 degree swirlers. The swirl was imparted to both streams in the same direction. The combustion occurred unconfined in stagnant surroundings. The nonintrusive measurements were obtained using a two-component phase/Doppler particle analyzer. The laser-based instrument measured two components of velocity as well as droplet size at a particular point. Gas phase measurements were obtained by seeding the air streams with nominal 1 micron size aluminum-oxide particles and using the measured velocity from that size to represent the gas phase velocity. The atomizing air, coflow air, and ambient surroundings were all seeded with the aluminum-oxide particles to prevent biasing. Measurements are reported at an axial distance of 5 mm from the nozzle. Isothermal single-phase gas velocities are also reported for comparison with the combusting case.

Bulzan, Daniel L.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD*P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

Bit-error-rate testing of fiber optic data links for MMIC-based phased array antennas

The measured bit-error-rate (BER) performance of a fiber optic data link to be used in satellite communications systems is presented and discussed. In the testing, the link was measured for its ability to carry high burst rate, serial-minimum shift keyed (SMSK) digital data similar to those used in actual space communications systems. The fiber optic data link, as part of a dual-segment injection-locked RF fiber optic link system, offers a means to distribute these signals to the many radiating elements of a phased array antenna. Test procedures, experimental arrangements, and test results are presented.

Shalkhauser, K. A.↗

Bit error rate testing of fiber optic data links for MMIC-based phased array antennas

The measured bit-error-rate (BER) performance of a fiber optic data link to be used in satellite communications systems is presented and discussed. In the testing, the link was measured for its ability to carry high burst rate, serial-minimum shift keyed (SMSK) digital data similar to those used in actual space communications systems. The fiber optic data link, as part of a dual-segment injection-locked RF fiber optic link system, offers a means to distribute these signals to the many radiating elements of a phased array antenna. Test procedures, experimental arrangements, and test results are presented.

Shalkhauser, K. A.↗

Behavior of Rapidly Sheared Bubble Suspensions

An experiment to be carried out aboard the International Space Station is described. A suspension consisting of millimeter-sized bubbles in water containing some dissolved salt, which prevents bubbles from coalescing, will be sheared in a Couette cylindrical cell. Rotation of the outer cylinder will produce centrifugal force which will tend to accumulate the bubbles near the inner wall. The shearing will enhance collisions among bubbles creating thereby bubble phase pressure that will resist the tendency of the bubbles to accumulate near the inner wall. The bubble volume fraction and velocity profiles will be measured and compared with the theoretical predictions. Ground-based research on measurement of bubble phase properties and flow in vertical channel are described.

Sangani, A. S.↗

Non-destructive evaluation of composite materials using ultrasound

Investigation of the nondestructive evaluation of advanced composite-laminates is summarized. Indices derived from the measurement of fundamental acoustic parameters are used in order to quantitatively estimate the local material properties of the laminate. The following sections describe ongoing studies of phase insensitive attenuation measurements, and discuss several phenomena which influences the previously reported technique of polar backscatter. A simple and effective programmable gate circuit designed for use in estimating attenuation from backscatter is described.

Miller, J. G.↗

Optimal wavefront control for adaptive segmented mirrors

A ground-based astronomical telescope with a segmented primary mirror will suffer image-degrading wavefront aberrations from at least two sources: (1) atmospheric turbulence and (2) segment misalignment or figure errors of the mirror itself. This paper describes the derivation of a mirror control feedback matrix that assumes the presence of both types of aberration and is optimum in the sense that it minimizes the mean-squared residual wavefront error. Assumptions of the statistical nature of the wavefront measurement errors, atmospheric phase aberrations, and segment misalignment errors are made in the process of derivation. Examples of the degree of correlation are presented for three different types of wavefront measurement data and compared to results of simple corrections.

Downie, John D.↗

Precise Tracking of the Magellan and Pioneer Venus Orbiters by Same-Beam Interferometry. Part 2: Orbit Determination Analysis

A new radio metric positioning technique has demonstrated improved orbit determination accuracy for the Magellan and Pioneer Venus Orbiter orbiters. The new technique, known as Same-Beam Interferometry (SBI), is applicable to the positioning of multiple planetary rovers, landers, and orbiters which may simultaneously be observed in the same beamwidth of Earth-based radio antennas. Measurements of carrier phase are differenced between spacecraft and between receiving stations to determine the plane-of-sky components of the separation vector(s) between the spacecraft. The SBI measurements complement the information contained in line-of-sight Doppler measurements, leading to improved orbit determination accuracy. Orbit determination solutions have been obtained for a number of 48-hour data arcs using combinations of Doppler, differenced-Doppler, and SBI data acquired in the spring of 1991. Orbit determination accuracy is assessed by comparing orbit solutions from adjacent data arcs. The orbit solution differences are shown to agree with expected orbit determination uncertainties. The results from this demonstration show that the orbit determination accuracy for Magellan obtained by using Doppler plus SBI data is better than the accuracy achieved using Doppler plus differenced-Doppler by a factor of four and better than the accuracy achieved using only Doppler by a factor of eighteen. The orbit determination accuracy for Pioneer Venus Orbiter using Doppler plus SBI data is better than the accuracy using only Doppler data by 30 percent.

Folkner, W. M.↗

An experiment for Shuttle aerodynamic force coefficient determination from inflight dynamical and atmospheric measurements

A two-phase experiment is proposed which utilizes the Shuttle Orbiter and its unique series of repeated entries into the earth's atmosphere as an airborne in situ aerodynamic testing laboratory. The objective of the experiment is to determine static aerodynamic force coefficients, first of the orbiter, and later of various entry configurations throughout the high speed flight regime, including the transition from free molecule to continuum fluid flow. The objective will be accomplished through analysis of inflight measurements from both shuttle-borne and shuttle-launched instrumented packages. Results are presented to demonstrate the feasibility of such an experiment.

Compton, H. R.↗

TRMM Version 8 Reprocessing Improvements and Incorporation into the GPM Data Suite

The National Aeronautics and Space Administration (NASA) has always included data reprocessing as a major component of every science mission. A final reprocessing is typically a part of mission closeout (known as phase F).The Tropical Rainfall Measuring Mission (TRMM) is currently in phase F, and NASA is preparing for the last reprocessing of all the TRMM precipitation data as part of the closeout. This reprocessing includes improvements in calibration of both the TRMM Microwave Imager (TMI) and the TRMM Precipitation Radar (PR). An initial step in the version 8 reprocessing is the improvement of geolocation. The PR calibration is being updated by the Japan Aerospace Exploration Agency (JAXA) using data collected as part of the calibration of the Dual-Frequency Precipitation Radar (DPR) on the Global Precipitation Measurement (GPM) Core Observatory. JAXA undertook a major effort to ensure TRMM PR and GPM Ku-band calibration is consistent. A major component of the TRMM version 8 reprocessing is to create consistent retrievals with the GPM version 05 (V05) retrievals. To this end, the TRMM version 8 reprocessing uses retrieval algorithms based on the GPM V05 algorithms. This approach ensures consistent retrievals from December 1997 (the beginning of TRMM) through the current ongoing GPM retrievals. An outcome of this reprocessing is the incorporation of TRMM data products into the GPM data suite. Incorporation also means that GPM file naming conventions and reprocessed TRMM data carry the V05 data product version. This paper describes the TRMM version 8 reprocessing, focusing on the improvements in TMI level 1 products.

Stocker, E. F.↗

The 2nd phase of the LEANDRE program: Water-vapor DIAL measurement

As a follow-on of the backscattered lidar, a differential absorption lidar (LEANDRE 2) is now being developed as part of the LEANDRE program for airborne meteorological studies. The primary measurement objective of LEANDRE 2 is water vapor. Pressure and temperature measurements are aimed at a second stage. The goals are to obtain a horizontal resolution of a few hundred meters for a vertical resolution of less than a hundred meters, with an absolute accuracy of 10 percent for humidity measurement. As compatibility is an important feature between the 2 first phases of LEANDRE, most of the LEANDRE 1 sub-system will be used and adapted for LEANDRE 2. For example, detection electronics, central computer, detectors and telescope will be the same. However, important modifications have to be done on the laser source, and spectral control has to be added. Most of the work is thus devoted to those developments, and the status is presented here.

Quaglia, P.↗

The 27-28 October 1986 FIRE IFO cirrus case study - Comparison of radiative transfer theory with observations by satellite and aircraft

Observations of cirrus and altocumulus clouds during the FIRE are compared to theoretical models of cloud radiative properties. Three tests are performed. First, radiances are used to compare the relationship between nadir reflectance ot 0.83 micron and beam emittance at 11.5 microns with that predicted for model calculations using spherical and nonspherical phase functions. Good agreement is found between observations and theory when water droplets dominate. Poor agreement is found when ice particles dominate, especially using spherical-particle phase functions (SPPFs). Even when compared to a laboratory-measured ice-particle phase function (IPPF), the observations show great side-scattered radiation than the theoretical calculations. Second, the anisotropy of conservatively scattered radiation is examined using simultaneous multiple angle views of the cirrus from Landsat and ER-2 aircraft radiometers. Observed anisotropy gives good agreement with theoretical calculations using the laboratory IPPF and poor agreement with an SPPF. Third, Landsat radiances at 0.83, 1.65, and 2.21 microns are used to infer particle phase and size. For water droplets, good agreement is found with particle-probe measurements in the cloud. For ice particles, the Landsat radiance observations predict an effective radius of 60 microns versus aircraft observations of about 200 microns. It is suggested that this discrepancy may be explained by uncertainty in the imaginary index of ice and by inadequate measurements of small ice particles by microphysical probes.

Wielicki, Bruce A.↗

Flight motor set 360L007 (STS-33R)

Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane↗

The Effects of LOX Post Biasing on SSME Injector Wall Compatibility

An experimental investigation has been carried out to examine the effects of LOX post biasing of a shear coaxial injector on the behavior of the spray near a chamber wall. The experimental work was performed with inert propellant simulants in a high-pressure chamber. Injector flow rates and chamber pressure were designed to match the Space Shuttle Main Engine (SSME) injector gas-to-liquid density and velocity ratio at the point of propellant injection. Measurements of liquid mass flux, gas phase velocity and droplet size were made using mechanical patternation and phase Doppler interferometry techniques. The measurements revealed that the liquid mass flux distribution shifts away from the wall with increasing LOX post bias away from the wall. The shift in the liquid flux distribution was much greater than that caused by the angling of the LOX post alone. Gas velocity near the wall simultaneously increased with increasing LOX post bias away from the wall. The increase in wall side gas velocity was due to the higher fraction of gas injected on the wall side of the injector as a result of the eccentricity at the injector exit. The net result is a decrease in mixture ratio near the wall. Estimates of heat transfer and engine performance relative to the unbiased case are presented.

Strakey, P. A.↗

Implementing a Digital Phasemeter in an FPGA

Firmware for implementing a digital phasemeter within a field-programmable gate array (FPGA) has been devised. In the original application of this firmware, the phase that one seeks to measure is the difference between the phases of two nominally-equal-frequency heterodyne signals generated by two interferometers. In that application, zero-crossing detectors convert the heterodyne signals to trains of rectangular pulses, the two pulse trains are fed to a fringe counter (the major part of the phasemeter) controlled by a clock signal having a frequency greater than the heterodyne frequency, and the fringe counter computes a time-averaged estimate of the difference between the phases of the two pulse trains. The firmware also does the following: Causes the FPGA to compute the frequencies of the input signals; Causes the FPGA to implement an Ethernet (or equivalent) transmitter for readout of phase and frequency values; and Provides data for use in diagnosis of communication failures. The readout rate can be set, by programming, to a value between 250 Hz and 1 kHz. Network addresses can be programmed by the user.

Rao, Shanti R.↗

Fast Plasma Instrument for MMS: Simulation Results

Magnetospheric Multiscale (MMS) mission will study small-scale reconnection structures and their rapid motions from closely spaced platforms using instruments capable of high angular, energy, and time resolution measurements. The Dual Electron Spectrometer (DES) of the Fast Plasma Instrument (FPI) for MMS meets these demanding requirements by acquiring the electron velocity distribution functions (VDFs) for the full sky with high-resolution angular measurements every 30 ms. This will provide unprecedented access to electron scale dynamics within the reconnection diffusion region. The DES consists of eight half-top-hat energy analyzers. Each analyzer has a 6 deg. x 11.25 deg. Full-sky coverage is achieved by electrostatically stepping the FOV of each of the eight sensors through four discrete deflection look directions. Data compression and burst memory management will provide approximately 30 minutes of high time resolution data during each orbit of the four MMS spacecraft. Each spacecraft will intelligently downlink the data sequences that contain the greatest amount of temporal structure. Here we present the results of a simulation of the DES analyzer measurements, data compression and decompression, as well as ground-based analysis using as a seed re-processed Cluster/PEACE electron measurements. The Cluster/PEACE electron measurements have been reprocessed through virtual DES analyzers with their proper geometrical, energy, and timing scale factors and re-mapped via interpolation to the DES angular and energy phase-space sampling measurements. The results of the simulated DES measurements are analyzed and the full moments of the simulated VDFs are compared with those obtained from the Cluster/PEACE spectrometer using a standard quadrature moment, a newly implemented spectral spherical harmonic method, and a singular value decomposition method. Our preliminary moment calculations show a remarkable agreement within the uncertainties of the measurements, with the results obtained by the Cluster/PEACE electron spectrometers. The data analyzed was selected because it represented a potential reconnection event as currently published.

Figueroa-Vinas, Adolfo↗