A BODIPY Based Fluorescent Probe for the Rapid Detection of Hypochlorite

A new boron-dipyrromethene (BODIPY) fluorescent dye aimed at sensitively detecting hypochlorite anion (ClO{sup −}) has been designed, synthesized and characterized. The probe is comprised of a BODIPY fluorophore unit and a ClO{sup −} specific reactive group of amidoxime. The addition of hypochlorite results in a red-shift of absorption and emission spectra of the probe accompanied by a decrease of intensity and spectra changes (A{sub 500} and 1/I{sub 512}) of the probe can achieve a good linearity to the concentration of ClO{sup −}. The fluorescence probe can react to ClO{sup −} rapidly (within 60 s) in a wide pH range (4–10) with high sensitivity (detection limit of 6.81 μM) and selectivity. The reaction mechanism has been proposed and confirmed by MS analysis, ClO{sup −} anion oxidizes amidoxime moiety to hydroxyl group and hydroxyl group is further oxidized to formyl group in the formation of a corresponding aldehyde compound. In addition, the probe has also been successfully applied to detect ClO{sup −} in tap water and river water samples by spiking a known amount of standard ClO{sup −}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Collaborative Research Activities of the Arase and Van Allen Probes

This paper presents the highlights of joint observations of the inner magnetosphere by the Arase spacecraft, the Van Allen Probes spacecraft, and ground-based experiments integrated into spacecraft programs. The concurrent operation of the two missions in 2017–2019 facilitated the separation of the spatial and temporal structures of dynamic phenomena occurring in the inner magnetosphere. Because the orbital inclination angle of Arase is larger than that of Van Allen Probes, Arase collected observations at higher L-shells up to L ~ 10. After March 2017, similar variations in plasma and waves were detected by Van Allen Probes and Arase. We describe plasma wave observations at longitudinally separated locations in space and geomagnetically-conjugate locations in space and on the ground. The results of instrument intercalibrations between the two missions are also presented. Arase continued its normal operation after the scientific operation of Van Allen Probes completed in October 2019. The combined Van Allen Probes (2012-2019) and Arase (2017-present) observations will cover a full solar cycle. This will be the first comprehensive long-term observation of the inner magnetosphere and radiation belts.

97 MATHEMATICS AND COMPUTING↗

Compact cantilever force probe for plasma pressure measurements

A simple, compact cantilever force probe (CFP) has been developed for plasma pressure measurements. It is based on the pull-in phenomenon well known in microelectromechanical-system electrostatic actuators. The probe consists of a thin (25 {mu}m) titanium foil cantilever (38 mm of length and 14 mm of width) and a fixed electrode separated by a 0.75 mm gap. The probe is shielded by brass box and enclosed into boron nitride housing with a 9 mm diameter window for exposing part of cantilever surface to the plasma. When the voltage is applied between the cantilever and the electrode, an attractive electrostatic force is counterbalanced by cantilever restoring spring force. At some threshold (pull-in) voltage the system becomes unstable and the cantilever abruptly pulls toward the fixed electrode until breakdown occurs between them. The threshold voltage is sensitive to an additional externally applied force, while a simple detection of breakdown occurrence can be used to measure that threshold voltage value. The sensitivity to externally applied forces obtained during calibration is 0.28 V/{mu}N (17.8 V/Pa for pressure). However, the resolution of the measurements is {+-}0.014 mN ({+-}0.22 Pa) due to the statistical scattering in measured pull-in voltages. The diagnostic temporal resolution is {approx}10 ms, being determined by the dynamics of pull-in process. The probe has been tested in the tokamak ISTTOK edge plasma, and a plasma force of {approx}0.07 mN (plasma pressure {approx}1.1 Pa) has been obtained near the leading edge of the limiter. This value is in a reasonable agreement with the estimations using local plasma parameters measured by electrical probes. The use of the described CFP is limited by a heat flux of Q{approx}10{sup 6} W/m{sup 2} due to uncontrollable rise of the cantilever temperature ({delta}T{approx}20 deg. C) during CFP response time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral measurements of runaway electrons by a scanning probe in the TEXTOR tokamak

Energy spectral measurements of runaway electrons were performed by a scanning probe with high spatial and temporal resolution in the TEXTOR tokamak. The probe consists of ten YSO (Y{sub 2}SiO{sub 5}:Ce) crystals, which are shielded by tungsten filters. The probe can resolve electrons with different energies between 4 and 30 MeV. An insertion of the probe to the plasma boundary several times during the discharge allowed spectral measurements of runaway electrons at different minor radial positions at the plasma edge as well as the study of runaway production in time. The high temporal resolution of the probe, 0.05 ms, enabled measurements of runaway electrons not only during low density discharges, but also during plasma disruptions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast ion measurement using a hybrid directional probe in the large helical device

A hybrid directional probe was newly installed in the large helical device for fast ion measurement. The collector of the probe mounts a thermocouple to estimate local power flux and can be also utilized as a collector of a conventional Langmuir probe; therefore, the hybrid directional probe can simultaneously measure both local power density flux and current flux at the same collector surface. The concept and design of the hybrid directional probe, the calibration of the power density measurement, and preliminary result of the fast ion measurement are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Langmuir Probe Method to the Atmospheric Pressure Discharge Plasma

The heat balance model in the probe tip applied to atmospheric pressure plasma is constructed. Considering the natural convective heat loss, the limitation of plasma density for probe application to such a plasma is estimated. The rough limit is about n{sub e} = 10{sup 18} m{sup -3}. Four kind of materials (Cu, SUS, W, Al) are used for probe tips, and are tested in DC atmospheric pressure discharge. Heat conductivity is found to be a more important property than melting point in design of probes in high pressure discharge. DC atmospheric pressure discharge plasma parameters are obtained with our test probes. Obtained density is the order of 10{sup 17} m{sup -3} and does not contradict with the above density limitation. Change of space potential in air/Ar plasma is also confirmed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling positive ion current to a planar probe in low-pressure electronegative discharges

A fluid model is utilized to describe the plasma-sheath boundary for a negatively biased planar probe immersed in electronegative plasmas. The model equations are solved on the scale of the electron Debye length and calculate the spatial distributions of electric potential, velocity, and density of positive ions in front of the probe. The position of sheath edge, the positive ion velocity at sheath edge (the Bohm velocity), and the positive ion flux collected by the probe are determined and compared with analytic (or scaling) formulas. Effects of control parameters on the Bohm velocity, the sheath thickness, and on the positive ion flux are investigated. A larger thermal motion of negative ions causes the Bohm velocity to increase, the sheath to increase, and the positive ion flux collected by the probe to increase. An increase in collision causes the Bohm velocity to decrease and the sheath to decrease resulting in a decrease in the positive ion flux. An increase in electronegativity causes both the Bohm velocity and the sheath thickness to decrease, resulting in an increase in the positive ion flux. As the value of the non-neutrality parameter q increases, the Bohm velocity and the sheath thickness are found to decrease, and the positive ion flux collected by the probe increases. The behavior of the positive ion flux entering the sheath is discussed as functions of control parameters. A careful comparison of theoretical positive ion flux with the experimental flux can allow us to obtain the electronegativity, the plasma ionization rate (q), and the collision parameter ({delta})

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multichannel Langmuir probe for turbulence study in Heliotron J

New multichannel Langmuir probe system was developed and installed to Heliotron J. The objective of the new probe is to characterize basic turbulence property and the resulting transport in advanced helical configuration. The probe developed here consists of four sets of triple probe and one pin for floating potential measurement. Initial experiments in neutral beam heating plasma were conducted and fluctuation profile of radial and poloidal electric fields and Reynolds stress were estimated. For precise evaluation of the electric fields and Reynolds stress, a technique to compensate radial change of tilt angle between probe array and magnetic surface was proposed and applied to the initial results obtained in edge region of Heliotron J where the complicated magnetic structure exists.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of radially movable multichannel Reynolds stress probe system for a cylindrical laboratory plasma

A new radially movable multichannel azimuthal probe system has been developed for measuring azimuthal and radial profiles of electrostatic Reynolds stress (RS) per mass density of microscale fluctuations for a cylindrical laboratory plasma. The system is composed of 16 probe units arranged azimuthally. Each probe unit has six electrodes to simultaneously measure azimuthal and radial electric fields for obtaining RS. The advantage of the system is that each probe unit is radially movable to measure azimuthal RS profiles at arbitrary radial locations as well as two-dimensional structures of fluctuations. The first result from temporal observation of fluctuation azimuthal profile presents that a low-frequency fluctuation (1-2 kHz) synchronizes oscillating Reynolds stress. In addition, radial scanning of the probe system simultaneously demonstrates two-dimensional patterns of mode structure and nonlinear forces with frequency f= 1.5 kHz and azimuthal mode number m= 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of electrostatic Langmuir probe to atmospheric arc plasmas producing nanostructures

The temporal evolution of a high pressure He arc producing nanotubes was considered and the Langmuir probe technique was applied for plasma parameter measurements. Two modes of arc were observed: cathodic arc where discharge is supported by erosion of cathode material and anodic arc which is supported by ablation of the anode packed with carbon and metallic catalysts in which carbon nanotubes are synthesized. Voltage-current (V-I) characteristics of single probes were measured and unusually low ratio of saturation current on positively biased probe to that on negatively biased of about 1-4 was observed. This effect was explained by increase of measured current at the negatively biased probe above the level of ion saturation current due to secondary electron emission from the probe surface. Since utilization of standard collisionless approach to determine plasma parameters from the measured V-I characteristic is not correct, the electron saturation current was used to estimate the plasma density.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental study of the ion current to a cylindrical Langmuir probe taking into account a finite ion temperature

This article deals with the experimental verification of a theoretical radial model, developed by the authors, for the sheath that surrounds a cylindrical Langmuir probe immersed in a plasma in which the positive ion temperature, T{sub i}, is not negligibly small compared to the electron temperature, T{sub e}. The theoretical model is a generalization of the classical one developed for cold ions by Allen, Boyd, and Reynolds for the case of spherical probes, and extended by Chen for cylindrical ones. According to our theory, due to the positive ion thermal motion the ion current collected by the probe is increased with respect to the case of cold ions, so its influence must be considered in plasma diagnosis. An experimental device to accurately measure the I-V characteristic of a cylindrical probe in plasma, for which T{sub i}/T{sub e} {ne} 0, has been developed. Very good agreement has been found between the theoretical positive ion I-V probe characteristic and the experimental values by using a Sonin plot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistic current collection by a cylindrical Langmuir probe

The current I to a cylindrical Langmuir probe with a bias {Phi}{sub p} satisfying {beta}{identical_to}e{Phi}{sub p}/m{sub e}c{sup 2}{approx}O(1) is discussed. The probe is considered at rest in an unmagnetized plasma composed of electrons and ions with temperatures kT{sub e}{approx}kT{sub i} Much-Less-Than m{sub e}c{sup 2}. For small enough radius, the probe collects the relativistic orbital-motion-limited (OML) current I{sub OML}, which is shown to be larger than the non-relativistic result; the OML current is proportional to {beta}{sup 1/2} and {beta}{sup 3/2} in the limits {beta} Much-Less-Than 1 and {beta} Much-Greater-Than 1, respectively. Unlike the non-relativistic case, the electron density can exceed the unperturbed density value. An asymptotic theory allowed to compute the maximum radius of the probe to collect OML current, the sheath radius for probe radius well below maximum and how the ratio I/I{sub OML} drops below unity when the maximum radius is exceeded. A numerical algorithm that solves the Vlasov-Poisson system was implemented and density and potential profiles presented. The results and their implications in a possible mission to Jupiter with electrodynamic bare tethers are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revisiting plasma hysteresis with an electronically compensated Langmuir probe

The measurement of electron temperature in plasma by Langmuir probes, using ramped bias voltage, is seriously affected by the capacitive current of capacitance of the cable between the probe tip and data acquisition system. In earlier works a dummy cable was used to balance the capacitive currents. Under these conditions, the measured capacitive current was kept less than a few mA. Such probes are suitable for measurements in plasma where measured ion saturation current is of the order of hundreds of mA. This paper reports that controlled balancing of capacitive current can be minimized to less than 20 {mu}A, allowing plasma measurements to be done with ion saturation current of the order of hundreds of {mu}A. The electron temperature measurement made by using probe compensation technique becomes independent of sweep frequency. A correction of {<=}45% is observed in measured electron temperature values when compared with uncompensated probe. This also enhances accuracy in the measurement of fluctuation in electron temperature as {delta}T{sub pk-pk} changes by {approx}30%. The developed technique with swept rate {<=}100 kHz is found accurate enough to measure both the electron temperature and its fluctuating counterpart. This shows its usefulness in measuring accurately the temperature fluctuations because of electron temperature gradient in large volume plasma device plasma with frequency ordering {<=}50 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Langmuir probe diagnostics of an atmospheric pressure, vortex-stabilized nitrogen plasma jet

Langmuir probe measurements in an atmospheric pressure direct current (dc) plasma jet are reported. Sweeping probes were used. The experiment was carried out using a dc non-transferred arc torch with a rod-type cathode and an anode of 5 mm diameter. The torch was operated at a nominal power level of 15 kW with a nitrogen flow rate of 25 Nl min{sup -1}. A flat ion saturation region was found in the current-voltage curve of the probe. The ion saturation current to a cylindrical probe in a high-pressure non local thermal equilibrium (LTE) plasma was modeled. Thermal effects and ionization/recombination processes inside the probe perturbed region were taken into account. Averaged radial profiles of the electron and heavy particle temperatures as well as the electron density were obtained. An electron temperature around 11 000 K, a heavy particle temperature around 9500 K and an electron density of about 4 Multiplication-Sign 10{sup 22} m{sup -3}, were found at the jet centre at 3.5 mm downstream from the torch exit. Large deviations from kinetic equilibrium were found throughout the plasma jet. The electron and heavy particle temperature profiles showed good agreement with those reported in the literature by using spectroscopic techniques. It was also found that the temperature radial profile based on LTE was very close to that of the electrons. The calculations have shown that this method is particularly useful for studying spraying-type plasma jets characterized by electron temperatures in the range 9000-14 000 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact high-speed reciprocating probe system for measurements in a Hall thruster discharge and plume

A compact high-speed reciprocating probe system has been developed in order to perform measurements of the plasma parameters by means of electrostatic probes in the discharge and the plume of a Hall thruster. The system is based on a piezoelectric linear drive that can achieve a speed of up to 350 mm/s over a travel range of 90 mm. Due to the high velocity of the linear drive the probe can be rapidly moved in and out the measurement region in order to minimize perturbation of the thruster discharge due to sputtering of probe material. To demonstrate the impact of the new system, a heated emissive probe, installed on the high-speed translation stage, was used to measure the plasma potential and the electron temperature in the near-field plume of a low power Hall thruster.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A direct Vlasov code to study the non-stationary current collection by a cylindrical Langmuir probe

The time-dependent current collection by a cylindrical Langmuir probe, whose bias is suddenly changed from zero to a positive or negative finite value, is studied with a novel direct Vlasov code. The numerical algorithm is based on finite-difference formulas to approximate spatial and velocity derivatives and the time integration is carried out with an explicit Runge-Kutta method, or in the case of probe radius small compared with the Debye length, by using the unconditionally stable backward Euler scheme. Both electrons and ions are treated kinetically by the code, which implements initial and boundary conditions that are consistent with the presence of the probe. Within the considered parameter range, the plasma sheath around the probe exhibited an overshoot and it later recovered a steady state. Phase space diagrams of the particle trajectories revealed the presence of a trapped population of particles. The dependence of this population as a function of the probe radius is presented as well as a comparison with the stationary theory. The performance of the code and a comparison with previously used particle-in-cell algorithms are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of current characteristics of segmented Langmuir probe on DEMETER

We model the current characteristics of the DEMETER Segmented Langmuir probe (SLP). The probe is used to measure electron density and temperature in the ionosphere at an altitude of approximately 700 km. It is also used to measure the plasma flow velocity in the satellite frame of reference. The probe is partitioned into seven collectors: six electrically insulated spherical segments and a guard electrode (the rest of the sphere and the small post). Comparisons are made between the predictions of the model and DEMETER measurements for actual ionospheric plasma conditions encountered along the satellite orbit. Segment characteristics are computed numerically with PTetra, a three-dimensional particle in cell simulation code. In PTetra, space is discretized with an unstructured tetrahedral mesh, thus, enabling a good representation of the probe geometry. The model also accounts for several physical effects of importance in the interaction of spacecraft with the space environment. These include satellite charging, photoelectron, and secondary electron emissions. The model is electrostatic, but it accounts for the presence of a uniform background magnetic field. PTetra simulation results show different characteristics for the different probe segments. The current collected by each segment depends on its orientation with respect to the ram direction, the plasma composition, the magnitude, and the orientation of the magnetic field. It is observed that the presence of light H{sup +} ions leads to a significant increase in the ion current branch of the I-V curves of the negatively polarized SLP. The effect of the magnetic field is demonstrated by varying its magnitude and direction with respect to the reference magnetic field. It is found that the magnetic field appreciably affects the electron current branch of the I-V curves of certain segments on the SLP, whereas the ion current branch remains almost unaffected. PTetra simulations are validated by comparing the computed characteristics and their angular anisotropy with the DEMETER measurements, as simulation results are found to be in good agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic dipole discharges. II. Cathode and anode spot discharges and probe diagnostics

The high current regime of a magnetron-type discharge has been investigated. The discharge uses a permanent magnet as a cold cathode which emits secondary electrons while the chamber wall or a grounded electrode serves as the anode. As the discharge voltage is increased, the magnet develops cathode spots, which are short duration arcs that provide copious electrons to increase the discharge current dramatically. Short (1 μs), high current (200 A) and high voltage (750 V) discharge pulses are produced in a relaxation instability between the plasma and a charging capacitor. Spots are also observed on a negatively biased plane Langmuir probe. The probe current pulses are as large as those on the magnet, implying that the high discharge current does not depend on the cathode surface area but on the properties of the spots. The fast current pulses produce large inductive voltages, which can reverse the electrical polarity of the magnet and temporarily operate it as an anode. The discharge current may also oscillate at the frequency determined by the charging capacitor and the discharge circuit inductance. Each half cycle of high-current current pulses exhibits a fast (≃10 ns) current rise when a spot is formed. It induces high frequency (10–100 MHz) transients and ringing oscillations in probes and current circuits. Most probes behave like unmatched antennas for the electromagnetic pulses of spot discharges. Examples are shown to distinguish the source of oscillations and some rf characteristics of Langmuir probes.