Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE VESSEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Glenn Extreme Environments Rig (GEER) Facility Users Guide

The Glenn Extreme Environment Rig (GEER) is a large capacity pressure vessel capable of simulating high pressure and temperature conditions with a specified, custom mixture of gas. The chamber is certified for operation in physical and chemical conditions representative of the surface conditions of Venus. It can accommodate large scientific or engineering test articles while maintaining the specified conditions indefinitely. The user-configurable gas supply is capable of handling a mixture of up to nine independent streams for injection directly into the vessel. GEER is supported in part by NASA’s Planetary Science Division under the Science Mission Directorate and is available for use by the commercial, academic, and research communities. GEER was operationally commissioned in November of 2014. At that time, it successfully maintained the temperature, pressure, and chemistry of the Venus surface atmosphere. In the spring of 2015, GEER began operations for engineering and scientific research. Since then, over 20 tests have been successfully conducted in the chamber with a variety of atmospheric test conditions.

Blake W. Beckley↗

A Proposal for the Maximum KIC for Use in ASME Code Flaw and Fracture Toughness Evaluations

Nonmandatory Appendices A [1] and G [2] of Section XI of the ASME Code use the KIc curve (indexed to the material reference transition temperature, RTNDT) in reactor pressure vessel (RPV) flaw evaluations, and for the purpose of establishing RPV pressure-temperature (P-T) limits. Neither of these appendices places an upper-limit on the KIc value that may be used in these assessments. Over the years, it has often been suggested by some of the members of the ASME Section XI Code committees that are responsible for maintaining Appendices A and G that there is a practical upper limit of 200 ksi in (220 MPa m) [4]. This upper limit is not well recognized by all users of the ASME Code, is not explicitly documented within the Code itself, and the one source known to the authors where it is defended [4] relies on data that is either in error, or is less than 220 MPa m. However, as part of the NRC/industry pressurized thermal shock (PTS) re-evaluation effort, empirical models were developed that propose common temperature dependencies for all ferritic steels operating on the upper shelf. These models relate the fracture toughness properties in the transition regime to those on the upper shelf and, combined with data for a wide variety of RPV steels and welds on which they are based, suggest that the practical upper limit of 220 MPa m exceeds the upper shelf fracture toughness of most RPV steels by a considerable amount, especially for irradiated steels. In this paper, available models and data are used to propose upper bound limits of applicability on the KIc curve for use in ASME Code, Section XI, Nonmandatory Appendices A and G evaluations that are consistent with available data for RPV steels.

36 MATERIALS SCIENCE↗

Using SA508/533 for the HTGR Vessel Material

This paper examines the influence of High Temperature Gas-cooled Reactor (HTGR) module power rating and normal operating temperatures on the use of SA508/533 material for the HTGR vessel system with emphasis on the calculated times at elevated temperatures approaching or exceeding ASME Code Service Limits (Levels B&C) to which the reactor pressure vessel could be exposed during postulated pressurized and depressurized conduction cooldown events over its design lifetime.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EDS V25 Containment Vessel Explosive Qualification Test Report

The V25 containment vessel was procured by the Project Manager, Non-Stockpile Chemical Materiel (PMNSCM) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the first EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel based on the Code Case is nine (9) pounds TNT-equivalent for up to 637 detonations. This limit is an increase from the 4.8 pounds TNT-equivalency rating for previous vessels. This report describes the explosive qualification tests that were performed in the vessel as part of the process for qualifying the vessel for explosive use. The tests consisted of a 11.25 pound TNT equivalent bare charge detonation followed by a 9 pound TNT equivalent detonation.

36 MATERIALS SCIENCE↗

Coupled modeling of a directly heated tubular solar receiver for supercritical carbon dioxide Brayton cycle: Structural and creep-fatigue evaluation

A supercritical carbon dioxide (sCO 2 ) Brayton cycle is an emerging high energy-density cycle undergoing extensive research due to the appealing thermo-physical properties of sCO 2 and single phase operation. Development of a solar receiver capable of delivering sCO 2 at 20 MPa and 700 °C is required for implementation of the high efficiency (~50%) solar powered sCO 2 Brayton cycle. In this work, extensive candidate materials are review along with tube size optimization using the ASME Boiler and Pressure Vessel Code. Moreover, temperature and pressure distribution obtained from the thermal-fluid modeling (presented in a complementary publication) are used to evaluate the thermal and mechanical stresses along with detailed creep-fatigue analysis of the tubes. For resulting body stresses were used to approximate the lifetime performance of the receiver tubes. A cyclic loading analysis is performed by coupling the Strain-Life approach and the Larson-Miller creep model. The structural integrity of the receiver was examined and it was found that the stresses can be withstood by specific tubes, determined by a parametric geometric analysis. The creep-fatigue analysis display the damage accumulation due to cycling and the permanent deformation on the tubes showed that the tubes can operate for the full lifetime of the receiver.

54 ENVIRONMENTAL SCIENCES↗

Design Overview of a High-Pressure Helium Flow Visualization Apparatus for Blanket Cooling Studies

Cooling of the fusion blanket first wall remains a significant challenge given the adverse conditions of heat and particle flux encountered near the plasma. Helium emerges as an attractive cooling candidate because of its chemical and neutronic inertness and separability from hydrogenic species (e.g. tritium). Because of the low thermal mass of helium, optimization of these coolant channels is warranted to provide high heat transfer performance at low pumping costs. Increasingly, computational fluid dynamics (CFD) simulations are employed to model and optimize these flow channels, and accompanying experimental data are needed to validate the predictions of these models. To provide the aforementioned experimental data, a high-pressure helium flow visualization upgrade has been designed for the Helium Flow Loop Experiment facility. This apparatus was built to American Society of Mechanical Engineers boiler and pressure vessel standards to withstand operating pressure of 4 MPa and mated to high-pressure glass windows. Seedless flow visualization is performed via high-speed background oriented schlieren (BOS), with image correlation used for time-resolved two-dimensional velocimetry at frequencies in excess of 60 kHz. Rectangular flow channel test articles are additively manufactured via laser powder bed fusion and installed into this visualization apparatus, with one-sided heating supplied by resistive heaters. In conclusion, the chosen test geometries were informed by prior CFD simulations, and the helium flow structures observed via BOS (detachment, recirculation, etc.) will be used for the validation of these accompanying models, in support of the design and optimization of blanket cooling channel configurations.

Helium flow↗

Modeling Simulation and Optimization of a Pressure Relief Feature in a Hermetically Sealed Volume Exposed to Abnormal Thermal Environments

This project investigates the behavior of a venting feature on a hermetically sealed volume under abnormal thermal environments. A pressure profile is used to simulate internal pressure build up due to thermal decomposition of foam caused by temperatures approaching 800K. For the purposes of his scoping study a small can composed of 304L stainless steel is used to emulate the problem at hand and simplify the model. The venting feature can be described as an elliptical thinned area with X-like scoring marks on the circumferential surface of the can where the highest stresses are located without the feature. The feature variables include elliptical size, depth, and quantity to optimize the venting feature geometry to vent at a desired pressure range. Cubit, SIERRA: Solid Mechanics, and Ensight modeling programs are used to simulate and analyze several iterations of this feature to determine the most optimal geometry. The model indicates through the simulations that the feature does in fact vent in a predictable manner and can be used in a variety of pressure vessel applications where uncontrolled over pressurizations are undesirable. Future work includes model validation tests, looking at different geometries, and using a more accurate failure criterion.

42 ENGINEERING↗

Development of Stable Solid Oxide Electrolysis Cells for Low-Cost Hydrogen Production

The project objective was to demonstrate a solid oxide cell-based steam electrolysis stack that exhibits robustness, reliability, endurance, hydrogen purity, and produces hydrogen at elevated pressure of 2 to 3 bar. Innovative materials and processing methods were evaluated to improve degradation characteristics. Performance improvement focused on nearly all layers involved in the cell and stack assembly. Primary attention was paid to zirconia-ceria interface resistance control via sintering optimization and decrease in degradation from the oxygen electrode by evaluating low strontium (Sr) or Sr-free composition for both the oxygen electrode and current collection layer. Stack robustness was addressed by validating redox tolerance of fuel electrode, confirming capability of cells to survive repeated thermal cycles, studying the effect of pressure on performance and degradation, evaluating the effect of contamination on fuel and oxygen electrode performance and degradation, and identifying mitigation strategies to improve performance. The characterization included evaluation of electrochemical performance and stability followed by microstructural analysis. At the cell level, performance and stability improvements were achieved by incorporating a Sr-free oxygen electrode and a denser oxygen electrode barrier layer. At the stack level, pressurized operation reduces demand on first stage compression, the redox tolerant fuel electrode mitigates risk from service interruptions, and improvements to interconnect coating alleviate chromium (Cr) contamination effects. The denser barrier layer was achieved by adding a sintering aid to the samaria-doped ceria (SDC) composition that reduced sintering temperature by 150 °C. The resulting density was on par with the baseline SDC barrier layer density and the lower sintering temperature resulted in less resistive phase formation during sintering. Button cell tests did not demonstrate a change in performance when exposed to silicon (Si) or manganese (Mn) impurities to the fuel electrode and Cr impurity to the oxygen electrode. More detailed study however is warranted. The project addressed SOEC performance and stability at the cell and stack levels through a systematic approach to known sources of degradation that were combined and tested in three stack tests using an electrolyte supported cell design to allow for evaluation of a variety of fuel and oxygen electrode compositions. STK-82 and STK-83 had identical compositions. STK-100 incorporated the best materials and processing variables developed under this and concurrent projects, and was tested at elevated pressure in steam electrolysis. • STK-82 recovered performance after redox and thermal cycling, demonstrating the robustness of the stack and seals. It exhibited stable performance in testing for 500 hours in SOEC mode, followed by 300 hours of cycling between SOEC and SOFC tests. Degradation during SOEC operation was 1.8 %/ 1,000 hours. • STK-83 generated hydrogen at >80% steam conversion, and oxygen above 98.5 % purity during pressurized operation. Both hydrogen and oxygen were generated at 3 barg pressure without the use of a pressure vessel. In addition to balanced pressure, electrolysis operation at 1 bar differential pressure across anode and cathode was also demonstrated to substantial the robustness of the cell and seal. • STK-100 measured at initial ambient pressure conditions showed an area specific resistance of 1.1 ohm-cm 2 , and STK-83 had 1.3 ohm-cm 2 .

08 HYDROGEN↗

Comparative thermal analysis of alternate Cryogenic Fluid Management Experiment (CFME) configurations

The Cryogenic Fluid Management Experiment (CFME) was analyzed to assess the feasibility and advisability of deleting the vapor cooled shield (VCS) from the baseline CFME insulation and pressure control system. Two alternate concepts of CFME insulation and pressure control, neither of which incorporated the VCS, were investigated. The first concept employed a thermodynamic vent system (TVS) to throttle the flow through an internal wall mounted heat exchanger (HX) within the pressure vessel to decrease boiloff and pressure rise rate, while the second concept utilized a TVS without an internal heat exchanger. Only the first concept was viable. Its performance was assessed for a seven day mission and found to be satisfactory. It was also concluded that VCS development costs would be greater than for an internal HX installation. Based upon the above comparisons, the HX was recommended as a replacement for the VCS.

Merino, F.↗

Quick actuating closure and handling system

A quick activating closure and handling system, which utilizes conical sections for locking, was developed to allow quick access to the combustor internal components of the 8 ft High Temperature Tunnel. These critical components include the existing methane spraybar, a transpiration cooled nozzle and the new liquid oxygen (LOX) injection system housed within the combustor. A substantial cost savings will be realized once the mechanism is installed since it will substantially reduce the access time and increase the time available for conducting wind tunnel tests. A need exists for more frequent inspections when the wind tunnel operates at the more severe conditions generated by using LOX in the combustor. A loads analysis and a structural (finite element) analysis were conducted to verify that the new closure system is compatible with the existing pressure shell. In addition, strain gages were placed on the pressure vessel to verify how the pressure shell reacts to transient pressure loads. A scale model of the new closure system was built to verify the operation of the conical sections in the locking mechanisms.

Allred, Johnny W.↗

Fast Quenching For Hydrogen-Embrittlement Tests

Apparatus exposes hot metal specimens in hydrogen atmospheres to sudden cooling. Heater surrounds pressure vessel initially. On command, heater slides downward on track, exposing vessel. Spray bar falls over vessel and directs high-pressure jets of cold water at it. Developed to evaluate susceptibilities of specimens to embrittlement by hydrogen. Cools specimens by 1,050 degrees F (580 degrees C) in 160 seconds.

Petri, Mark J.↗

Interplanetary Trajectory Design for NASA's Common Probe Study

The Galileo Probe, Pioneer-Venus probes, and SPRITE concept all share a number of common characteristics. They all follow a similar entry and descent sequence, using an aeroshell to protect against entry environments, and parachutes to aid in extrusion and descent speed control of the descent vehicle containing the science instruments. The descent vehicles all contained similar instruments (e.g. mass spectrometers and atmosphere structure sensors), and data was either relayed back to a carrier spacecraft (Galileo Probe, SPRITE) or transmitted direct to Earth (Pioneer-Venus). Based on these similar characteristics, NASA initiated a study to investigate a “common probe' that might be designed to perform similar science in a variety of planetary environments. This concept would leverage a common aeroshell design, and descent vehicle designs that could be made as similar as possible (the primary exception being that Venus will require a pressure vessel due to the extreme pressures and temperatures seen in the lower portion of the descent). To support the Common Probe study, GSFC and JPL performed a series of interplanetary trajectory analyses to help develop the mission designs for Venus, Jupiter, Saturn, Uranus, and Neptune. Primary considerations in the trajectory modeling included: a maximum of 12-year time of flight (for outer planet destinations), generation of both steep and shallow entry trajectories to each destination (where steep and shallow resulted in approximately 150 g and 50 g peak deceleration during entry at each location), and consideration of the data relay. Gravity assists and trajectories with low delta-V requirements (typically much less than 500 m/s) were also incorporated into the design process to enable launch on existing vehicles such as the Atlas V.

Hughes, Kyle M.↗

Hydrogen storage container

An apparatus and system is described for storing high-pressure fluids such as hydrogen. An inner tank and pre-stressed concrete pressure vessel share the structural and/or pressure load on the inner tank. The system and apparatus provide a high performance and low cost container while mitigating hydrogen embrittlement of the metal tank. System is useful for distributing hydrogen to a power grid or to a vehicle refueling station.

08 HYDROGEN↗

High-Pressure, Normal-Gravity Droplet Combustion Experimental Hardware

The High-Pressure, Trans-Critical (HPTC) 1-g Liquid Droplet Combustion Experiments will assess the autoignition and combustion of liquid fuel droplets at elevated temperatures and pressures. These experiments are being conducted at the NASA Glenn Research Center in a manner similar to experiments performed in Glenn’s Zero Gravity Research Facility (ZGF) using the B drop vehicle. The modification to the test capabilities of the ZGF experiments in the new experimental configuration will allow researchers to continue performing normal-gravity liquid droplet combustion experiments without requiring the use of the ZGF test equipment. These normal-gravity experiments will be conducted at lower pressures than in the ZGF because the pressure vessel for this setup is limited to a maximum working pressure of 7.74 atm (99.1 psig) at 366.5 K (200 °F). This experimental configuration will enable development of a similar capability for conducting high-pressure combustion and supercritical oxidation research on the International Space Station. Experiments will be conducted with the capability of altering the ambient pressure, temperature, and gas concentrations, as well as the fuel type for each test. For these experiments, the test vessel operates at pressures up to 7.5 atm (95.5 psig), temperatures up to 1,073 K (1,472 °F) inside the insulated oven, and oxygen concentrations up to 30 percent.

Droplet Combustion↗

TRACE and TRAC-BF1 benchmark against Leibstadt plant data during the event inadvertent opening of relief valves

In framework of introducing TRACE code to transient analyses system codes for Leibstadt Power Plant (KKL), a conversion process of existing TRAC-BF1 model to TRACE has been started within KKL. In the first step, TRACE thermal-hydraulic model for KKL has been developed based on existing TRAC-BF1 model. In order to assess the code models a simulation of plant transient event is required. In this matter simulations of inadvertent opening of 8 relief valves event have been performed. The event occurs at KKL during normal operation, and it started when 8 relief valves open resulting in depressurization of the Reactor Pressure Vessel (RPV). The reactor was shutdown safely by SCRAM at low level. The high pressure core spray (HPCS) and the reactor core isolation cooling (RCIC) have been started manually in order to compensate the level drop. The remaining water in the feedwater (FW) lines flashes due to saturation conditions originated from RPV depressurization and refills the reactor downcomer. The plant boundary conditions have been used in the simulations and the FW flow rate has been adjusted for better prediction. The simulations reproduce the plant data with good agreement. It can be concluded that the TRAC-BF1 existing model has been used successfully to develop the TRACE model and the results of the calculations have shown good agreement with plant recorded data. Beside the modeling assessment, the TRACE and TRAC-BF1 capabilities to reproduce plant physical behavior during the transient have shown satisfactory results. The first step of developing KKL model for TRACE has been successfully achieved and this model is further developed in order to simulate more complex plant behavior such as Turbine Trip. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Unique safety features and licensing requirements of the NuScale small modular reactor

Small modular reactors (SMR) offer a novel approach to the construction and operation of nuclear power plants. The NuScale VOYGR™ plant uses a simplified SMR design that is based on proven light-water reactor technology with substantial improvements in nuclear safety. It consists of a 250 MWt reactor core housed with other primary system components in an integral reactor pressure vessel surrounded by a steel containment vessel, all of which is immersed in a large pool of water that also serves as the ultimate heat sink. At the core of the NuScale safety case are three primary safety systems: the decay heat removal system, the emergency core cooling system, and the containment. The ability of the NuScale Power Module (NPM) passive safety systems to remove core decay heat for an unlimited duration is demonstrated through analysis of a beyond-design-basis extended loss of AC power with no replenishment of water to the ultimate heat sink or operator actions. The NuScale methodology to evaluate an indefinite loss of AC power uses the proprietary NRELAP5 systems analysis computer code. Analysis results show that the reactor coolant system liquid level above the core is maintained and that containment pressure remains below the vessel design pressure. Once full passive air cooling is established, containment pressure and temperature will decrease over time with decreasing core decay heat. NuScale received standard design approval in September 2020 and design certification in January 2023 for its 50 MWe NPM configured as a 12 module plant. NuScale is currently seeking standard design approval to increase its core power to 250 MWt, nominally 77 MWe per module, in a 6-module plant (VOYGR™-6) configuration. The high-level safety of NuScale’s SMR technology is foundational to a new standard of nuclear power plant resilience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Techno-economic analysis of conventional and advanced high-pressure tube trailer configurations for compressed hydrogen gas transportation and refueling

Transporting compressed gaseous hydrogen in tube trailers to hydrogen refueling stations (HRSs) is an attractive economic option in early fuel cell electric vehicle (FCEV) markets. This study examines conventional (Type I, steel) and advanced (Type IV, composite) high-pressure tube trailer configurations to identify those that offer maximum payload and lowest cost per unit of deliverable payload under United States Department of Transportation (DOT) size and weight constraints. The study also evaluates the impacts of various tube trailer configurations and payloads on the transportation and refueling cost of hydrogen under various transportation distance and HRS capacity scenarios. Composite tube trailers can transport large hydrogen payloads, up to 1100 kg at 7300 psi (500 bar) working pressure, while steel tube trailer configurations are limited by DOT weight regulations and may transport a maximum hydrogen payload of approximately 270 kg. Using steel pressure vessels to transport hydrogen at high pressure is counterproductive because of the rapid increase in vessel weight with wall thickness. The most economic composite tube trailer configuration includes 30-inch-diameter vessels packed in a 3 x 3 array. A linear relationship between the deliverable payload and the capital cost of a composite tube trailer has been developed for configurations with the lowest cost-per-unit payload. The capital cost is approximately $1100 per kg of deliverable hydrogen payload. Considering the entire delivery pathway (including refueling), tube trailer configurations with smaller vessels packed in greater numbers enable higher payload delivery and lower delivery cost in terms of $/kg H-2, when delivering hydrogen over longer distances to large stations. Selection of the appropriate tube trailer configuration and corresponding hydrogen payload can reduce hydrogen delivery cost by up to 16%. (C) 2018 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

composite tubes↗

Reversible high-pressure carbon nanotube vessel

Applying a full pressure loop, i.e., loading and unloading, on a nanocrystal with in situ observation remains a challenge to experimentalists up until now. Using a multiwalled carbon nanotube, we realize the pressure loop acting on a Fe{sub 3}C nanocrystal (with peak value 20 GPa) by electron-beam irradiation with in situ observations inside transmission electron microscopy at 500 deg. C/ambient temperature. Using density-functional theory calculations, we attribute the unloading process to the formation of one dangling-bond single vacancies under the electron-beam irradiation at room temperature. A theoretical model is presented to understand the process and the results agree well with the experimental measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗