Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA ELECTRODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Optical and Kinetic Characteristics of an Atmospheric Pressure Pulsed Discharge in Helium with Iron Vapor

The emission spectrum of a near-cathode plasma of a pulsed discharge in atmospheric pressure helium reveals spectral lines of electrode material. Numerical simulation of the kinetics by the Monte Carlo method shows that starting with a fraction of percent, the addition of iron atoms to helium strongly affect the ionization-drift characteristics of electrons in gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma nitriding monitoring reactor: A model reactor for studying plasma nitriding processes using an active screen

A laboratory scale plasma nitriding monitoring reactor (PLANIMOR) has been designed to study the basics of active screen plasma nitriding (ASPN) processes. PLANIMOR consists of a tube reactor vessel, made of borosilicate glass, enabling optical emission spectroscopy (OES) and infrared absorption spectroscopy. The linear setup of the electrode system of the reactor has the advantages to apply the diagnostic approaches on each part of the plasma process, separately. Furthermore, possible changes of the electrical field and of the heat generation, as they could appear in down-scaled cylindrical ASPN reactors, are avoided. PLANIMOR has been used for the nitriding of steel samples, achieving similar results as in an industrial scale ASPN reactor. A compact spectrometer using an external cavity quantum cascade laser combined with an optical multi-pass cell has been applied for the detection of molecular reaction products. This allowed the determination of the concentrations of four stable molecular species (CH{sub 4}, C{sub 2}H{sub 2}, HCN, and NH{sub 3}). With the help of OES, the rotational temperature of the screen plasma could be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of confinement in a toroidal plasma subject to strong radial electric fields

A preliminary report on the identification and optimization of independent variables which affect the ion density and confinement time in a bumpy torus plasma is presented. The independent variables include the polarity, position, and number of the midplane electrode rings, the method of gas injection, and the polarity and strength of a weak vertical magnetic field. Some characteristic data taken under condition when most of the independent variables were optimized are presented. The highest value of the electron number density on the plasma axis is 3.2 x 10 to the 12th power/cc, the highest ion heating efficiency is 47 percent, and the longest particle containment time is 2.0 milliseconds.

Roth, J. R.↗

Spatial profiles of electron and metastable atom densities in positive polarity fast ionization waves sustained in helium

Fast ionization waves (FIWs), often generated with high voltage pulses over nanosecond timescales, are able to produce large volumes of ions and excited states at moderate pressures. The mechanisms of FIW propagation were experimentally and computationally investigated to provide insights into the manner in which these large volumes are excited. The two-dimensional structure of electron and metastable densities produced by short-pulse FIWs sustained in helium were measured using laser-induced fluorescence and laser collision-induced fluorescence diagnostics for times of 100–120 ns after the pulse, as the pressure was varied from 1 to 20 Torr. A trend of center-peaked to volume-filling to wall-peaked electron density profiles was observed as the pressure was increased. Instantaneous FIW velocities, obtained from plasma-induced emission, ranged from 0.1 to 3×10⁹cm s⁻¹, depending on distance from the high voltage electrode and pressure. Predictions from two-dimensional modeling of the propagation of a single FIW correlated well with the experimental trends in electron density profiles and wave velocity. Results from the model show that the maximum ionization rate occurs in the wavefront, and the discharge continues to propagate forward after the removal of high voltage from the powered electrode due to the potential energy stored in the space charge. As the pressure is varied, the radial distribution of the ionization rate is shaped by changes in the electron mean free path, and subsequent localized electric field enhancement at the walls or on the centerline of the discharge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of possible lower hybrid emission from the NASA Lewis bumpy torus plasma

Radio frequency emission has been detected near the power hybrid frequency of a bumpy torus plasma by using a responsive detection system that consists of a spectrum analyzer and a 50 ohm miniature coaxial antenna concentrically located in a re-entrant quartz tube. The frequency shift of a broad emission peak was monitored as a function of background pressure, electrode voltage, and the strength of the dc magnetic field. Simultaneous measurements of the average plasma density were made with a polarization diplexing microwave interferometer. The information derived from the experiment is discussed with particular reference to the following: (1) whether the emissions are dominated by atomic or molecular species of deuterium; (2) the strength of the dc magnetic field in the emitting region; (3) the geometric location of the emitting region of the plasma; (4) comparison of the lower hybrid plasma density with the average plasma density; and (5) relation of ion spoke geometry to lower hybrid emission.

Mallavarpu, R.↗

Advancing local helicity injection for non-solenoidal tokamak startup

Experiments on the A ~ 1 PEGASUS ST are advancing the physics and technology basis of Local Helicity Injection (LHI). LHI injects helicity with relatively intense electron current sources in the plasma edge. It creates high toroidal current, toroidally-averaged tokamak-like plasmas that have been efficiently transitioned to Ohmically driven tokamak plasmas. Tradeoffs between physics and engineering goals are tested with LHI systems on the low-field-side and the high-field-side of PEGASUS, producing plasmas predominantly driven by non-solenoidal induction and DC helicity drive, respectively. An extensive LHI source development campaign comparing active arc sources, passive and gas-effused electrode sources lead to the selection of active arc sources for present and next-step LHI deployments. LHI plasmas with net toroidal current I p =0.225 MA, T e >100 eV, and n e ~ 10 19 m -3 are attained to date. A predictive 0D power-balance model describes experimental I p (t) and partitions the active current drive sources. High-frequency MHD activity is found to be present during LHI current drive, in addition to n=1 modes previously found in NIMROD simulation and experiment. A new system of reduced MHD activity was detected where n=1 activity is suppressed, LHI CD efficiency improves, and long-pulse plasmas are sustained with V IND ~ 0.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Ignition of Pulsed Gas Discharges in Air of Low Pressure in a Coaxial Plasma Gun

The effect of an axial magnetic field on the breakdown voltage of a coaxial system of electrodes has been investigated by earlier workers. For low values of gas pressure times electrode spacing, the breakdown voltage is decreased by the application of the magnetic field. The electron cyclotron radius now assumes the role held by the mean free path in nonmagnetic discharges and the breakdown voltage becomes a function of the magnetic flux density. In this paper the dependence of the formative time lag as a function of the magnetic flux density is established and the feasibility of using a magnetic field for igniting high-voltage, high-current discharges is shown through theory and experiment. With a 36 microfarad capacitor bank charged to 48,000 volts, a peak current of 1.3 x 10( exp 6) amperes in a coaxial type of plasma gun was achieved with a current rise time of only 2 microseconds.

Thom, Karlheinz↗

Fast camera studies at an electron cyclotron resonance table plasma generator

A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the 14 GHz ATOMKI-ECRIS. Plasma diagnostics experiments are planned to be performed at this device before installing the measurement setting at the “big” ECRIS. Recently, the plasma generator has been operated in pulsed RF mode in order to investigate the time evolution of the ECR plasma in two different ways. (1) The visible light radiation emitted by the plasma was investigated by the frames of a fast camera images with 1 ms temporal resolution. Since the visible light photographs are in strong correlation with the two-dimensional spatial distribution of the cold electron components of the plasma it can be important to understand better the transient processes just after the breakdown and just after the glow. (2) The time-resolved ion current on a specially shaped electrode was measured simultaneously in order to compare it with the visible light photographs. The response of the plasma was detected by changing some external setting parameters (gas pressure and microwave power) and was described in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental verification of the capillary plasma triggered long spark gap under the extremely low working coefficient in air

The paper has proposed a new triggering method for long spark gap based on capillary plasma ejection and conducted the experimental verification under the extremely low working coefficient, which represents that the ratio of the spark gap charging voltage to the breakdown voltage is particularly low. The quasi-neutral plasma is ejected from the capillary and develops through the axial direction of the spark gap. The electric field in the spark gap is thus changed and its breakdown is incurred. It is proved by the experiments that the capillary plasma ejection is effective in triggering the long spark gap under the extremely low working coefficient in air. The study also indicates that the breakdown probabilities, the breakdown delay, and the delay dispersion are all mainly determined by the characteristics of the ejected plasma, including the length of the plasma flow, the speed of the plasma ejection, and the ionization degree of the plasma. Moreover, the breakdown delay and the delay dispersion increase with the length of the long spark gap, and the polarity effect exists in the triggering process. Lastly, compared with the working patterns of the triggering device installed in the single electrode, the working pattern of the devices installed in both the two electrodes, though with the same breakdown process, achieves the ignition under longer gap distance. To be specific, at the gap length of 14 cm and the working coefficient of less than 2%, the spark gap is still ignited accurately.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Composition, Work Function, and Electrochemical Characteristics of Gallium-Doped Zinc Oxide

Gallium-doped zinc oxide (GZO) possesses the electric conductivity, thermal stability, and earth abundance to be a promising transparent conductive oxide replacement for indium tin oxide electrodes in a number of molecular electronic devices, including organic solar cells and organic light emitting diodes. The surface chemistry of GZO is complex and dominated by the hydrolysis chemistry of ZnO, which influences the work function via charge transfer and band bending caused by adsorbates. A comprehensive characterization of the surface chemical composition and electrochemical properties of GZO electrodes is presented, using both solution and surface adsorbed redox probe molecules. The GZO surface is characterized using monochromatic X-ray photoelectron spectroscopy and ultraviolet photoelectron spectroscopy after the following pretreatments: (i) hydriodic acid etch, (ii) potassium hydroxide etch, (iii) RF oxygen plasma etching, and (iv) high-vacuum argon-ion sputtering. The O 1s spectra for the GZO electrodes have contributions from the stoichiometric oxide lattice, defects within the lattice, hydroxylated species, and carbonaceous impurities, with relative near-surface compositions varying with pretreatment. Solution etching procedures result in an increase of the work function and ionization potential of the GZO electrode, but yield different near surface Zn:Ga atomic ratios, which significantly influence charge transfer rates for a chemisorbed probe molecule. The near surface chemical composition is shown to be the dominant factor in controlling surface work function and significantly influences the rate of electron transfer to both solution and tethered probe molecules.

14 SOLAR ENERGY↗

Spectroscopic Determination of Trace Contaminants in High-Purity Oxygen

Oxygen used for extravehicular activities (EVAs) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen has been developed. This instrument uses a glow discharge in reduced-pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete, and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants, and may lend itself to a device capable of on-orbit verification of oxygen purity. A glow discharge is a plasma formed in a low-pressure (1 to 10 Torr) gas cell between two electrodes. Depending on the configuration, voltages ranging from 200 V and above are required to sustain the discharge. In the discharge region, the gas is ionized and a certain population is in the excited state. Light is produced by the transitions from the excited states formed in the plasma to the ground state. The spectrum consists of discrete, narrow emission lines for the atomic species, and broader peaks that may appear as a manifold for molecular species such as O2 and N2, the wavelengths and intensities of which are a characteristic of each atom. The oxygen emission is dominated by two peaks at 777 and 844 nm.

Hornung, Steven↗

Determination of a macro- to micro-scale progression leading to a magnetized plasma disruption

We report here the observations of a plasma jet evolving through a macro- to micro-scale progression sequence. This leads to a fast magnetic reconnection that results in the jet breaking off from its originating electrode and forming a force-free state. A sausage-like pinching occurs first and squeezes an initially fat, short magnetized jet so that it becomes thin. The thin jet then becomes kink unstable. The lengthening of the jet by the kinking thins the jet even more since the kink is an incompressible instability. When the jet radius becomes comparable to the ion-skin depth, Hall and electron inertial physics become important and establish the environment for a fast magnetic reconnection. This fast reconnection occurs, disrupting the jet and establishing a force-free state. X-ray bursts and whistler waves, evidence of a magnetic reconnection, are observed when the plasma jet breaks off from the electrode. This experimentally confirmed sequence of successive thinning from pinching followed by kinking is reproduced in a three-dimensional ideal Magnetohydrodynamic (MHD) numerical simulation. The results of the experiment and the numerical simulation, together demonstrate a viable path from macro-scale MHD physics to micro-scale non-MHD physics where fast reconnection occurs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recommended Practice for Use of Emissive Probes in Electric Propulsion Testing

Here, this article provides recommended methods for building, operating, and taking plasma potential measurements from electron-emitting probes in electric propulsion devices, including Hall thrusters, gridded ion engines, and others. The two major techniques, the floating point technique and the inflection point technique, are described in detail as well as calibration and error-reduction methods. The major heating methods are described as well as the various considerations for emissive probe construction. Lastly, special considerations for electric propulsion plasmas are addressed, including high-energy densities, ion flows, magnetic fields, and potential fluctuations. Recommendations for probe design and operation are provided.

33 ADVANCED PROPULSION SYSTEMS↗

Femtosecond laser guiding of a high-voltage discharge and the restoration of dielectric strength in air and nitrogen

The use of a low energy, high peak intensity (>100 TW/cm{sup 2}) femtosecond laser pulse is investigated for guiding and control of a sub-microsecond high voltage discharge. Study of the laser induced plasma channel and measurements of the field required for breakdown in air and nitrogen at atmospheric pressure are presented. Direct imaging of the dynamics of the discharge breakdown shows effective laser guiding. The effectiveness of laser guiding is shown to be critically dependent on the laser focusing geometry, timing, and location relative to the electrodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of possible lower hybrid emission from the NASA Lewis Bumpy Torus plasma

Radio frequency emission detected near the lower hybrid frequency of the NASA Lewis Bumpy Torus plasma is studied, using a simple detection system that consists of a spectrum analyzer and a 50-ohm miniature co-axial antenna concentrically located in a re-entrant quartz tube. The frequency shift of a broad emission peak is monitored as a function of the background pressure, electrode voltage, and the strength of the dc magnetic field. Simultaneous measurements of the average plasma density are made with a polarization diplexing microwave interferometer. Information from the experiment is discussed with particular reference to the role of atomic or molecular species of deuterium in the emissions, the strength of the dc magnetic field in the emitting region, the geometric location of the emitting region of the plasma, the lower hybrid plasma density as compared with the average plasma density, and the relation of the ion spoke geometry to the lower hybrid emission.

Mallavarpu, R.↗

Potentiometric measurement of polymer-membrane electrodes based on lanthanum

Quantitative analysis of rare earth elements which are considered as the standard method that has a high accuracy, and detection limits achieved by the order of ppm is inductively coupled plasma atomic emission spectroscopy (ICPAES). But these tools are expensive and valuable analysis of the high cost of implementation. In this study be made and characterized selective electrode for the determination of rare earth ions is potentiometric. Membrane manufacturing techniques studied is based on immersion (liquid impregnated membrane) in PTFE 0.5 pore size. As ionophores to be used tri butyl phosphate (TBP) and bis(2-etylhexyl) hydrogen phosphate. There is no report previously that TBP used as ionophore in polymeric membrane based lanthanum. Some parameters that affect the performance of membrane electrode such as membrane composition, membrane thickness, and types of membrane materials studied in this research. Manufacturing of Ion Selective Electrodes (ISE) Lanthanum (La) by means of impregnation La membrane in TBP in kerosene solution has been done and showed performance for ISE-La. FTIR spectrum results for PTFE 0.5 pore size which impregnated in TBP and PTFE blank showed difference of spectra in the top 1257 cm{sup −1}, 1031 cm{sup −1} and 794.7 cm{sup −1} for P=O stretching and stretching POC from group −OP =O. The result showed shift wave number for P =O stretching of the cluster (−OP=O) in PTFE-TBP mixture that is at the peak of 1230 cm{sup −1} indicated that no interaction bond between hydroxyl group of molecules with molecular clusters fosforil of TBP or R{sub 3}P = O. The membrane had stable responses in pH range between 1 and 9. Good responses were obtained using 10{sup −3} M La(III) internal solution, which produced relatively high potential. ISE-La showed relatively good performances. The electrode had a response time of 29±4.5 second and could be use for 50 days. The linear range was between 10{sup −5} and 10{sup −1} M.

36 MATERIALS SCIENCE↗

Absolute determination of charge-coupled device quantum detection efficiency using Si K-edge x-ray absorption fine structure

We report a method to determine the quantum detection efficiency and the absorbing layers on a front-illuminated charge-coupled device (CCD). The CCD under study, as part of a crystal spectrometer, measures intense continuum x-ray emission from a picosecond laser-produced plasma and spectrally resolves the Si K-edge x-ray absorption fine structure features due to the electrode gate structure of the device. The CCD response across the Si K-edge shows a large discontinuity as well as a number of oscillations that are identified individually and uniquely from Si, SiO{sub 2}, and Si{sub 3}N{sub 4} layers. From the spectral analysis of the structure and K-edge discontinuity, the active layer thickness and the different absorbing layers thickness can be determined precisely. A precise CCD detection model from 0.2-10 keV can be deduced from this highly sensitive technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Treated Active Carbon for Capacitive Deionization of Saline Water

The plasma treatment on commercial active carbon (AC) was carried out in a capacitively coupled plasma system using Ar + 10% O 2 at pressure of 4.0 Torr. The RF plasma power ranged from 50 W to 100 W and the processing time was 10 min. The carbon film electrode was fabricated by electrophoretic deposition. Micro-Raman spectroscopy revealed the highly increased disorder of sp 2 C lattice for the AC treated at 75 W. An electrosorption capacity of 6.15 mg/g was recorded for the carbon treated at 75 W in a 0.1 mM NaCl solution when 1.5 V was applied for 5 hours, while the capacity of the untreated AC was 1.0 mg/g. The plasma treatment led to 5.09 times increase in the absorption capacity. The jump of electrosorption capacity by plasma treatment was consistent with the Raman spectra and electrochemical double layer capacitance. This work demonstrated that plasma treatment was a potentially efficient approach to activating biochar to serve as electrode material for capacitive deionization (CDI).

36 MATERIALS SCIENCE↗