Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: METSAT A1 Signal Processor (P/N 1331670-2, S/N F03)

This report presents a description of tests performed, and the test data, for the A1 METSAT Signal Processor Assembly PN: 1331679-2, S/N F03. This assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive Test and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

Lund, D.↗

Integrated Advanced Microwave Sounding Unit-A(AMSU-A). Engineering Test Report: METSAT A1 Signal Processor, (P/N 1331670-2, S /N F05)

This report presents a description of the tests performed, and the test data, for the AI METSAT Signal Processor Assembly P/N 1331670-2, S/N F05. The assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

Lund, D.↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: METSAT A1 Signal Processor (P/N: 1331670-2, S/N: F04)

This report presents a description of the tests performed, and the test data, for the A1 METSAT Signal Processor Assembly PN: 1331679-2, S/N F04. The assembly was tested in accordance with AE-26754, "METSAT Signal Processor Scan Drive Test and Integration Procedure." The objective is to demonstrate functionality of the signal processor prior to instrument integration.

Lund, D.↗

Summary of Proton Test on the Actel A1280A at Indiana University

A summary of tests performed at the Indiana University Cycl,oltron Facility, on the Actel A1280A circuit device is described. The intent of the study was to investigate the proton response of the hard-wired S-Module flip-flops with a large sample size. This device is sensitive to protons for S-Modules. The device's performance in the test is shown in graphs, and was typical for devices of this class.

Katz, Richard↗

Low Crossover Polymer Electrolyte Membranes for Direct Methanol Fuel Cells

Direct Methanol Fuel Cells (DMFC's) using polymer electrolyte membranes are promising power sources for portable and vehicular applications. State of the art technology using Nafion(R) 117 membranes (Dupont) are limited by high methanol permeability and cost, resulting in reduced fuel cell efficiencies and impractical commercialization. Therefore, much research in the fuel cell field is focused on the preparation and testing of low crossover and cost efficient polymer electrolyte membranes. The University of Southern California in cooperation with the Jet Propulsion Laboratory is focused on development of such materials. Interpenetrating polymer networks are an effective method used to blend polymer systems without forming chemical links. They provide the ability to modify physical and chemical properties of polymers by optimizing blend compositions. We have developed a novel interpenetrating polymer network based on poly (vinyl - difluoride)/cross-linked polystyrenesulfonic acid polymer composites (PVDF PSSA). Sulfonation of polystyrene accounts for protonic conductivity while the non-polar, PVDF backbone provides structural integrity in addition to methanol rejection. Precursor materials were prepared and analyzed to characterize membrane crystallinity, stability and degree of interpenetration. USC JPL PVDF-PSSA membranes were also characterized to determine methanol permeability, protonic conductivity and sulfur distribution. Membranes were fabricated into membrane electrode assemblies (MEA) and tested for single cell performance. Tests include cell performance over a wide range of temperatures (20 C - 90 C) and cathode conditions (ambient Air/O2). Methanol crossover values are measured in situ using an in-line CO2 analyzer.

Prakash, G. K. Surya↗

Spiral Bevel Gear Damage Detection Using Decision Fusion Analysis

A diagnostic tool for detecting damage to spiral bevel gears was developed. Two different monitoring technologies, oil debris analysis and vibration, were integrated using data fusion into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual monitoring technologies. This diagnostic tool was evaluated by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spiral Bevel Gear Fatigue Rigs. Data was collected during experiments performed in this test rig when pitting damage occurred. Results show that combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spiral bevel gears.

Dempsey, Paula J.↗

An Improved Thermal Conductivity Polyurethane Composite for a Space Borne 20KV Power Supply

This effort was designed to find a way to reduce the temperature rise of critical components of a 20KV High Voltage Power Supply (HVPS) by improving the overall thermal conductivity of the encapsulated modules. Three strategies were evaluated by developing complete procedures, preparing samples, and performing tests. The three strategies were: 1. Improve the thermal conductivity of the polyurethane encapsulant through the addition of thermally conductive powder while minimizing impact on other characteristics of the encapsulant. 2. Improve the thermal conductivity of the polyurethane encapsulated assembly by the addition of a slab of thermally conductive, electrically insulating material, which is to act as a heat spreader. 3. Employ a more thermally conductive substrate (Al203) with the existing encapsulation scheme. The materials were chosen based on the following criteria: high dielectric breakdown strength; high thermal conductivity, ease of manufacturing, high compliance, and other standard space qualified materials properties (low out-gassing, etc.). An optimized cure was determined by a statistical design of experiments for both filled and unfilled materials. The materials were characterized for the desired properties and a complete process was developed and tested. The thermal performance was substantially improved and the strategies may be used for space flight.

Pb free↗

The E-3 Test Facility at Stennis Space Center: Research and Development Testing for Cryogenic and Storable Propellant Combustion Systems

This paper will provide the reader a broad overview of the current upgraded capabilities of NASA's John C. Stennis Space Center E-3 Test Facility to perform testing for rocket engine combustion systems and components using liquid and gaseous oxygen, gaseous and liquid methane, gaseous hydrogen, hydrocarbon based fuels, hydrogen peroxide, high pressure water and various inert fluids. Details of propellant system capabilities will be highlighted as well as their application to recent test programs and accomplishments. Data acquisition and control, test monitoring, systems engineering and test processes will be discussed as part of the total capability of E-3 to provide affordable alternatives for subscale to full scale testing for many different requirements in the propulsion community.

Pazos, John T.↗

Space Suit Material Compatibility with Space Vehicle Coolant PMS-1.5R

During a survey of 82P on February 11, 2023, a shiny substance was detected on the Progress vehicle. The suspected material was PMS-1.5R, a low volatility silicone oil coolant used in the vehicle. Crew exposure to the coolant was a concern as the low volatility would increase residence time, the time a material will stay on a surface after exposure to vacuum. A review of space suit materials revealed several materials with compatibility concerns that could impact Extravehicular Activity (EVA) operations and safety. To understand the risk, space suit materials were exposed to a simulant and tested. This testing provided the basis for rationale generated to continue with EVA operations for US EVA 86 on April 2, 2023. This testing also served as the basis to assess impacts to ISS EMU hardware due to potential contamination brought inside ISS on Russian space suits during RS EVA 61 on October 25, 2023, following an ISS Russian Multipurpose Lab Module (MLM) radiator leak of the same fluid on October 9, 2023. This paper will discuss the testing performed and analyze test results impacts to EVA operations. Additional work was conducted to determine coolant evaporation rates in space vacuum and demonstrate that no significant unreacted coolant from the MLM leak would remain on ISS surfaces long enough to contaminate the EMU or affect the ISS ECLSS water separator.

Space Suit Materials↗

Post-Flight Test Results of Seed Laser Module Subjected to Space Exposure

The objective of the Materials International Space Station Experiment (MISSE) is to study the performance of novel materials when subjected to the synergistic effects of the harsh space environment for several months. MISSE missions provide an opportunity for developing space qualifiable materials. Several laser and lidar components were sent by NASA Langley Research Center (LaRC) as a part of the MISSE 7 mission. The MISSE 7 module was transported to the international space station (ISS) via STS 129 mission that was launched on Nov 16, 2009. Later, the MISSE 7 module was brought back to the earth via the STS 134 that landed on June 1, 2011. The MISSE 7 module that was subjected to exposure in space environment for more than one and a half year included fiber laser, solid-state laser gain materials, detectors, and semiconductor laser diode. Performance testing of these components is now progressing. In this paper, the results of performance testing of a laser diode module sent by NASA Langley Research Center on MISSE 7 mission will be discussed. This paper will present the comparison of pre-flight and post-flight performance curves and discuss the effect of space exposure on the laser diode module. Preliminary findings on output power measurements show that the COTS laser diode characteristics did not undergo any significant performance degradation.

Prasad, Narasimha S.↗

Continuation Report: Creep-fatigue Behavior and Damage Accumulation of a Candidate Structural Material for Concentrating Solar Thermal Receiver

At the start of this phase, six alloys were determined to be candidate materials for the concentrating solar power (CSP) thermal receiver: Alloys 617, 625, 740H, 230, 282 and Alloy X. From these, Alloys 740H and 282 were determined to be the most suitable, with both alloys exhibiting similar high temperature strength properties. Alloy 740H was selected due to its ease to work with (simpler heat treatments and welding procedures) and a larger database of existing data. Fatigue testing was started in this phase, with four fatigue tests having been completed, with additional fatigue testing planned, as well as tensile, creep and creep-fatigue tests starting in the next phase. Two fatigue tests performed at 850 °C and were completed in significantly fewer cycles than the two tests performed at 750 °C. Metallography was performed on the fatigued specimens to examine crack path and surrounding microstructure. These preliminary results suggest a significant drop in strength at elevated temperatures above 750 °C, however, more test results will be needed prior to setting design limits. Several potential model high temperature design methods were evaluated that could form the basis of our final recommended creep-fatigue design method for Alloy 740H. To do this we expanded on the receiver finite element model to develop a model representative of a potential Gen 3 design using KCl-MgCl2 salt coolant and operating with a salt inlet temperature of 550°C and salt outlet temperature of 720°C. Using the temperature fields from the model thermohydraulic analysis we determined the design life of the reference receiver assuming it was constructed from 740H seamless tubing and assuming high temperature design properties for 740H from literature data and, where required, naïve extrapolation. As experimental data is generated, these tentative design parameters will be updated to match the actual performance of 740H in elevated temperature service. The results of this design study are a rank ordering of potential design methods for two criteria: ease of use and design margin. The end goal of this project is to develop a creep-fatigue design method with adequate, but not over conservative, design margin that is straightforward to execute. Our receiver model is based on the preliminary design provided to DOE by Solar Reserve. Our analysis indicates a peak metal temperature of around 840° C for this design (comparable to Solar Reserve’s analysis, which shows a peak metal temperature of around 830° C). The Solar Reserve tube thickness is too thin to sustain creep-fatigue loading at this temperature. This means that the current trial design is not well-suited for evaluating different design methodologies, as we predict it will have a very short design life. We suggest that we modify our reference design with input from DOE in order to lower the maximum metal temperature to less than 800° C. We can then repeat these analyses and give a more meaningful comparison of different design methods before making a final selection.

14 SOLAR ENERGY↗

Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137 source placed in the centre of the measurement chamber. Small sources have also been used to determine the spatial variation of the detection efficiency for various positions within the measurement chamber. The data have been used to establish sentencing limits and different 'fingerprints' for specific waste streams including waste streams containing fission products and others based on other radionuclides including Am-241. Some of the test data that are presented have been used to validate the instrument performance. The monitor is currently in routine use at a nuclear facility for the measurement and sentencing of low-density low activity radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control of Ionomer Distribution and Porosity in Roll-to-Roll Coated Fuel Cell Catalyst Layers

As fuel cells transition from the laboratory to industrial production for vehicles and other applications there is a need to understand how manufacturing processes impact the properties and, ultimately, the performance of materials. Roll-to-roll coating enables processing at meters per second speeds with physics that can be quite different from common laboratory coating methods. In this work, we have focused on the coating of catalyst layers for proton exchange membrane fuel cells. Commonly, laboratory samples are prepared using spray coating or hand painting, which effectively coat many thin layers to achieve the desired catalyst layer thickness. This creates catalyst layers with uniform distributions of materials throughout the thickness of the full catalyst layer. In contrast, roll-to-roll methods, like slot die and gravure, coat the catalyst layer as a single wet film. As the film dries, ink constituents are able to segregate, leading to a heterogeneous distribution of materials through the thickness of the layer. It is also known that solvent and drying rate can affect the morphology of the catalyst layer. Thus, there is a need to understand how ink formulation and the drying process influence the distribution of materials and catalyst layer morphology. Here, we have explored the influence of solvent and drying rate on morphology of roll-to-roll coated catalyst layers. We show the development of the Kelvin probe method as a rapid screening technique for qualitative analysis of ionomer distribution. We also utilize nano X-ray computed tomography to visualize electrode structure and to quantify particle-size and pore-size distributions, thickness-dependent ionomer distribution, tortuosity, and effective transport properties. We find that solvent has a strong influence on ionomer distribution, with less of an effect on porosity. Conversely, drying temperature has a strong influence on porosity, but less influence on ionomer distribution. Finally, we utilize in situ fuel cell performance testing and other advanced diagnostics to quantify the impact of catalyst layer properties on fuel cell performance and demonstrate that roll-to-roll coating is capable of coating high performance catalyst layers in multi-meter lengths. have focused on the coating of catalyst layers for proton exchange membrane fuel cells. Commonly, laboratory samples are prepared using spray coating or hand painting, which effectively coat many thin layers to achieve the desired catalyst layer thickness. This creates catalyst layers with uniform distributions of materials throughout the thickness of the full catalyst layer. In contrast, roll-to-roll methods, like slot die and gravure, coat the catalyst layer as a single wet film. As the film dries, ink constituents are able to segregate, leading to a heterogeneous distribution of materials through the thickness of the layer. It is also known that solvent and drying rate can affect the morphology of the catalyst layer. Thus, there is a need to understand how ink formulation and the drying process influence the distribution of materials and catalyst layer morphology. Here, we have explored the influence of solvent and drying rate on morphology of roll-to-roll coated catalyst layers. We show the development of the Kelvin probe method as a rapid screening technique for qualitative analysis of ionomer distribution. We also utilize nano X-ray computed tomography to visualize electrode structure and to quantify particle-size and pore-size distributions, thickness-dependent ionomer distribution, tortuosity, and effective transport properties. We find that solvent has a strong influence on ionomer distribution, with less of an effect on porosity. Conversely, drying temperature has a strong influence on porosity, but less influence on ionomer distribution. Finally, we utilize in situ fuel cell performance testing and other advanced diagnostics to quantify the impact of catalyst layer properties on fuel cell performance and demonstrate that roll-to-roll coating is capable of coating high performance catalyst layers in multi-meter lengths.

30 DIRECT ENERGY CONVERSION↗

Post-Flight Test Results of Acousto-Optic Modulator Devices Subjected to Space Exposure

The objective of the Materials International Space Station Experiment (MISSE) is to study the performance of novel materials when subjected to the synergistic effects of the harsh space environment for several months. MISSE missions provide an opportunity for developing space qualifiable materials. Several laser and lidar components were sent by NASA Langley Research Center (LaRC) as a part of the MISSE 7 mission. The MISSE 7 module was transported to the international space station (ISS) via STS 129 mission that was launched on Nov 16, 2009. Later, the MISSE 7 module was brought back to the earth via the STS 134 that landed on June 1, 2011. The MISSE 7 module that was subjected to exposure in a space environment for more than one and a half years included fiber laser, solid-state laser gain materials, detectors, and semiconductor laser diode. Performance testing of these components is now progressing. In this paper, the results of performance testing of a laser diode module sent by NASA Langley Research Center on MISSE 7 mission will be discussed. This paper will present the comparison of pre-flight and post-flight performance of two different COTS acousto-optic modulator (AOM) devices. Post-flight measurements indicate that these two devices did not undergo any significant performance degradation.

Prasad, Narasimha S.↗

Ride qualities criteria validation/pilot performance study: Flight test results

Pilot performance during a terrain following flight was studied for ride quality criteria validation. Data from manual and automatic terrain following operations conducted during low level penetrations were analyzed to determine the effect of ride qualities on crew performance. The conditions analyzed included varying levels of turbulence, terrain roughness, and mission duration with a ride smoothing system on and off. Limited validation of the B-1 ride quality criteria and some of the first order interactions between ride qualities and pilot/vehicle performance are highlighted. An earlier B-1 flight simulation program correlated well with the flight test results.

Nardi, L. U.↗

Summary of Attached Inflatable Decelerator (AID) Development

Attached inflatable decelerators (AID) were tested in an environmental chamber, a spin tunnel, and a wind tunnel. Deployment tests were conducted in environmental chamber to examine guided and unguided water alcohol vapor inflation. Subsonic performance tests were conducted in the spin tunnel. The full-scale wind tunnel was used for AID gust and supersonic performance tests. The supersonic tests were conducted at Mach number 3.0 with 12 ounces of fluid and Mach number 2.2 with six ounces of fluid.

Source record↗

Point Defect Characterization in CdZnTe

Measurements of the defect levels and performance testing of CdZnTe detectors were performed by means of Current Deep Level Transient Spectroscopy (I-DLTS), Transient Charge Technique (TCT), Current versus Voltage measurements (I-V), and gamma-ray spectroscopy. CdZnTe crystals were acquired from different commercial vendors and characterized for their point defects. I-DLTS studies included measurements of defect parameters such as energy levels in the band gap, carrier capture cross sections, and defect densities. The induced current due to laser-generated carriers was measured using TCT. The data were used to determine the transport properties of the detectors under study. A good correlation was found between the point defects in the detectors and their performance.