At least 829 records · Page 46

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing IMAC-XL

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Development of 2.05 µm Fiber Lasers for CO2 DIAL Lidar Measuring Martian CO2 and Pressure

The Decadal Survey by the National Academy of Sciences in the United States and NASA’s Science Mission Directorate (SMD) Science Plan both require global CO 2 observations for the Martian atmospheric pressure, dynamics and chemistry. However, there are significant observational gaps in polar regions and during nighttime for global air pressure and CO 2 on Mars. Therefore, recently we proposed a new concept of Martian differential absorption lidar (DIAL) operating in the 2.05 µm CO 2 absorption band for global, including poles, atmospheric CO 2 and pressure observations day and night [1]. Based on the concept, we are awarded to develop 2.05 µm fiber lasers by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Program. The laser is designed to be an all-fiber master oscillator and power amplifier (MOPA) system with laser output of ~3 mJ at a repetition frequency of 2 kHz. The primary master oscillator (PMO) is locked to the center (2.0504280 µm) of the selected CO 2 absorption line. The frequency of a second MO (SMO) is locked to that of PMO. This SMO frequency is adjustable and switched between the online (2.05044156 µm) and offline (2.05050812 µm) wavelengths. The online wavelength is optimally selected so that the CO 2 absorption optical depth (AOD) is ~1.1 at 3 km and the measurement in the low Martian atmosphere has largest signal-to-noise ratio. The online wavelength can also be adjusted to a line slope location where AOD is larger to observe atmospheric pressure at higher altitudes. We will present more detail about this project and instrument development at the conference.

Zhaoyan Liu↗

Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults With Amputations

The first single function myoelectric prosthetic hand was introduced in the 1960's. This hand was controlled by the electric fields generated by muscle contractions in the residual limb of the amputee user. Electrodes and amplifiers, embedded in the prosthetic socket, measured these electric fields across the skin, which increase in amplitude as the individual contracts their muscle. When the myoelectric signal reached a certain threshold amplitude, the control unit activated a motor which opened or closed a hand-like prosthetic terminal device with a pincher grip. Late in the 1990's, little has changed. Most current myoelectric prostheses still operate in this same, single-function way. To better understand the limitations of the current single-function myoelectric hand and the needs of those who use them, The Institute for Rehabilitation and Research (TIRR), sponsored by the National Institutes of Health (NUH), surveyed approximately 2,500 individuals with upper limb loss [1]. When asked to identify specific features of their current myoelectric prostheses that needed improvement, the survey respondents overwhelmingly identified the lack of wrist and finger movement, as well as poor control capability. However, simply building a mechanism with individual finger and wrist motion is not enough. In the 1960's and 1970's, engineers built a number of more dexterous prosthetic hands. Unfortunately, these were rejected during clinical trials due to a difficult and distracting control interface. The goal of this project, "Applying Space Technology to Enhance Control of an Artificial Arm for Children and Adults with Amputations," was to lay the foundation for a multi-function, intuitive myoelectric control system which requires no conscious thought to move the hand. We built an extensive myoelectric signal database for six motions from ten amputee volunteers, We also tested a control system based on new artificial intelligence techniques on the data from two of these subjects. This data is available to anyone doing myoelectric control research. Its availability is an important contribution to the prosthetics research community, as many researchers do not have access to amputee subjects. Since we collected myoelectric data from subjects' sound arms as well as their residual arms, this database will also prove useful to virtual reality and robotics researchers who want to explore myoelectric-based interfaces between any user and a machine. Currently, one small company (Intelligenta, Inc.) and one university (University of New Brunswick, Canada) are using this myoelectric database under other funding to develop multifunction control systems for prostheses. A prosthetics manufacturer (Liberty Technology, Inc.) is making plans to incorporate the results of their work into an artificial hand capable of several different movements to provide functionality only dreamed of by current myoelectric users. Methods Six adults and four children, all with unilateral, below-elbow amputations served as subjects. Five of the adults (3 male, 2 female, average age 34 years) had amputations due to traumatic injury, while one adult (female, age 32 years) and the four children (3 male, 1 female, average age 13 years) had congenital (i.e. from birth) limb deficiencies.

Atkins, Diane J.↗

Integrated imaging sensor systems with CMOS active pixel sensor technology

This paper discusses common approaches to CMOS APS technology, as well as specific results on the five-wire programmable digital camera-on-a-chip developed at JPL. The paper also reports recent research in the design, operation, and performance of APS imagers for several imager applications.

double sampling↗

Large CMOS imager using hadamard transform based multiplexing

We have developed a concept design for a large (~10k x 10k) CMOS imaging array whose elements are grouped in small subarrays with N pixels in each. The subarrays are code-division multiplexed using the Hadamard Transform (HT) based encoding. The Hadamard code improves the signal-to-noise (SNR) ratio to the reference of the read-out amplifier by a factor of N^1/2. This way of grouping pixels reduces the number of hybridization bumps by N. A single chip layout has been designed and the architecture of the imager has been developed to accommodate the HT base multiplexing into the existing CMOS technology. The imager architecture allows for a trade-off between the speed and the sensitivity. The envisioned imager would operate at a speed >100 fps with the pixel noise < 20 e-. The power dissipation would be ~100 pW/pixe1. The combination of the large format, high speed, high sensitivity and low power dissipation can be very attractive for space reconnaissance applications.

CMOS imager↗

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

Preamplifier Noise in VLF Receivers

Noise specifications for junction field-effect transistors are presented in different ways depending on the particular semiconductor manufacturer. Arithmetic involved in converting these specifications to equivalent RMS noise in microvolts developed at the preamplifier input terminal is reviewed. These methods were useful for estimating the noise performance of high input impedance preamplifiers used with E-field antennas operating in the range of 1 KHz to 10 MHz. Both the JFET MPF-102 transistor and the COS/MOS CA3600 transistor array provided amplification for VLF receivers where the internally generated noise was well below the atmospheric noise level. The CA3600 transistor array provided better performance because of the more symmetrical complementary MOS transistor transfer characteristics than a single N-type biased JFET transistor. The CMOS amplifier resulted in self-compensating gain characteristics over a very wide temperature range from -55 to +125 C.

Burhans, R. W.↗

Prototype data terminal-multiplexer/demultiplexer

The design and operation of a quad redundant data terminal and a multiplexer/demultiplexer (MDU) is described. The most unique feature is the design of the quad redundant data terminal. This is one of the few designs where the unit is fail/op, fail/op, fail/safe. Laboratory tests confirm that the unit will operate satisfactorily with the failure of three out of four channels. Although the design utilizes state-of-the-art technology, the waveform error checks, the voting techniques, and the parity bit checks are believed to be used in unique configurations. Correct word selection routines are also novel. The MDU design, while not redundant, utilizes, the latest state-of-the-art advantages of light coupler and interested amplifiers. Much of the technology employed was an evolution of prior NASA contracts related to the Addressable Time Division Data System. A good example of the earlier technology development was the development of a low level analog multiplexer, a high level analog multiplexer, and a digital multiplexer. A list of all drawings is included for reference and all schematic, block and timing diagrams are incorporated.

Leck, D. E.↗

Evaluation of the JPL X-band 32 element active array

Tests performed on an X-band 32-element active array are described. Antenna pattern characteristics of the array were tested in its standard operating mode as well as several degraded performance modes, including failures of 1, 2, 3, 4, 8, 16, and 31 elements. Additionally, the array was characterized with the addition of a metallic shroud, and also characterized versus rf drive level and at a single off-axis electronic beamsteered position. Characterization was performed on several of the 3/4-watt, three-stage, X-band solid-state power amplifier modules. The characterization included swept amplitude response, amplitude and phase versus temperature from -20 to +60 C, and intermodulation distortion of selected modules. The array is described and conclusions and recommendations based upon the experience and results achieved are included.

Boreham, J. F.↗

An overview of DREV's activities on pulsed CO2 laser transmitters: Frequency stability and lifetime aspects

After introducing the desired features in a transmitter for laser radar applications, the output characteristics of several configurations of frequency-stable TEA-CO2 lasers are reviewed. Based on work carried out at the Defence Research Establishment Valcartier (DREV), output pulses are examined from short cavity lasers, CW-TEA hybrid lasers, and amplifiers for low power pulses. It is concluded that the technique of injecting a low-power laser beam into a TEA laser resonator with Gaussian reflectivity mirrors should be investigated because it appears well adapted to producing high energy, single mode, low chirp pulses. Finally, a brief report on tests carried out on catalysts composed of stannic oxide and noble metals demonstrates the potential of these catalysts, operating at close to room temperature, to provide complete closed-cycle laser operation.

Cruickshank, James↗

Modular Low-Heater-Power Cathode/Electron Gun Assembly for Microwave and Millimeter Wave Traveling Wave Tubes

A low-cost, low-mass, electrically efficient, modular cathode/electron gun assembly has been developed by FDE Inc. of Beaverton, Oregon, under a Small Business Innovation Research (SBIR) contract with the NASA Glenn Research Center at Lewis Field. This new assembly offers significant improvements in the design and manufacture of microwave and millimeter wave traveling-wave tubes (TWT's) used for radar and communications. It incorporates a novel, low-heater-power, reduced size and mass, high-performance barium dispenser type thermionic cathode and provides for easy integration of the cathode into a large variety of conventional TWT circuits. Among the applications are TWT's for Earth-orbiting communication satellites and for deep space communications, where future missions will require smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. A particularly important TWT application is in the microwave power module (a hybrid microwave/millimeter wave amplifier consisting of a low-noise solid-state driver, a small TWT, and an electronic power conditioner integrated into a single compact package), where electrical efficiency and thermal loading are critical factors and lower cost is needed for successful commercialization. The design and fabrication are based on practices used in producing cathode ray tubes (CRT's), which is one of the most competitive and efficient manufacturing operations in the world today. The approach used in the design and manufacture of thermionic cathodes and electron guns for CRT's has been optimized for fully automated production, standardization of parts, and minimization of costs. It is applicable to the production of similar components for microwave tubes, with the additional benefits of low mass and significantly lower cathode heater power (less than half that of dispenser cathodes presently used in TWT s). Modular cathode/electron gun assembly. The modular cathode/electron gun assembly consists of four subassemblies the cathode, the focus electrode, the header (including the electrical feedthroughs), and the gun envelope (including the anode) a diagram of which is shown. The modular construction offers a number of significant advantages, including flexibility of design, interchangeability of parts, and a drop-in final assembly procedure for quick and accurate alignment. The gun can accommodate cathodes ranging in size from 0.050 to 0.250-in. in diameter and is applicable to TWT's over a broad range of sizes and operating parameters, requiring the substitution of only a few parts: that is, the cathode, focus electrode, and anode. The die-pressed cathode pellets can be made with either flat or concave (Pierce gun design) emitting surfaces. The gun can be either gridded (pulse operation) or ungridded (continuous operation). Important factors contributing to low cost are the greater use of CRT materials and parts, the standardization of processes (welding and mechanical capture), and tooling amenable to automated production. Examples are the use of simple shapes, drawn or stamped metal parts, and parts joined by welding or mechanical capture. Feasibility was successfully demonstrated in the retrofit and testing of a commercial Kaband (22-GHz) TWT. The modular cathode/electron gun assembly was computer modeled to replicate the performance of the original electron gun and fabricated largely from existing CRT parts. Significant test results included demonstration of low heater power (1.5-W, 1010 C brightness temperature for a 0.085-in.-diameter cathode), mechanical ruggedness (100g shock and vibration tests in accordance with military specifications (MIL specs)), and a very fast warmup. The results of these tests indicate that the low-cost CRT manufacturing approach can be used without sacrificing performance and reliability.

Wintucky, Edwin G.↗

NASA Tech Briefs, May 2005

Topics covered include: Fastener Starter; Multifunctional Deployment Hinges Rigidified by Ultraviolet; Temperature-Controlled Clamping and Releasing Mechanism; Long-Range Emergency Preemption of Traffic Lights; High-Efficiency Microwave Power Amplifier; Improvements of ModalMax High-Fidelity Piezoelectric Audio Device; Alumina or Semiconductor Ribbon Waveguides at 30 to 1,000 GHz; HEMT Frequency Doubler with Output at 300 GHz; Single-Chip FPGA Azimuth Pre-Filter for SAR; Autonomous Navigation by a Mobile Robot; Software Would Largely Automate Design of Kalman Filter; Predicting Flows of Rarefied Gases; Centralized Planning for Multiple Exploratory Robots; Electronic Router; Piezo-Operated Shutter Mechanism Moves 1.5 cm; Two SMA-Actuated Miniature Mechanisms; Vortobots; Ultrasonic/Sonic Jackhammer; Removing Pathogens Using Nano-Ceramic-Fiber Filters; Satellite-Derived Management Zones; Digital Equivalent Data System for XRF Labeling of Objects; Identifying Objects via Encased X-Ray-Fluorescent Materials - the Bar Code Inside; Vacuum Attachment for XRF Scanner; Simultaneous Conoscopic Holography and Raman Spectroscopy; Adding GaAs Monolayers to InAs Quantum-Dot Lasers on (001) InP; Vibrating Optical Fibers to Make Laser Speckle Disappear; Adaptive Filtering Using Recurrent Neural Networks; and Applying Standard Interfaces to a Process-Control Language.

Source record↗

2-Micron Diode-Pumped Pulsed Laser Transmitter for SPARCLE: A Coherent Wind Lidar Shuttle Mission

To enable a tropospheric vector wind velocity profiling from space with a pulsed Doppler lidar, a diode-pumped, room temperature Ho:Tm:YLF coherent pulsed transmitter has been developed at NASA Langley Research Center. This pulsed laser transmitter will be a part of coherent wind lidar shuttle mission SPARCLE. The acronym stands for SPAce Readiness Coherent Lidar Experiment and is primarily a technology demonstration mission and is expected to fly in 2001 as NASA's New Millennium Program (NMP) second Earth Orbiter (EO-2) mission. The laser transmitter for SPARCLE is a Ho:Tm:YLF power oscillator operating at eye-safe wavelength of 2.05 microns. The Q-switched output energy is 125 mJ at six Hz, and it has a near-transform limited beam with a pulse width of 170 ns. The high power and high beam quality of this laser makes it well suited as a coherent wind lidar transmitter on a space platform. When the output of this power oscillator is amplified by using four diode-pumped Ho:Tm:YLF amplifiers, an output energy of 600 mJ at 10 Hz is achieved. This is the highest energy ever produced at 10 Hz, and is at least an order of magnitude greater than previously achieved for a 2-micron diode-pumped laser at room temperature.

Singh, Upendra N.↗

A More Accurate and Efficient Technique Developed for Using Computational Methods to Obtain Helical Traveling-Wave Tube Interaction Impedance

The phenomenal growth of commercial communications has created a great demand for traveling-wave tube (TWT) amplifiers. Although the helix slow-wave circuit remains the mainstay of the TWT industry because of its exceptionally wide bandwidth, until recently it has been impossible to accurately analyze a helical TWT using its exact dimensions because of the complexity of its geometrical structure. For the first time, an accurate three-dimensional helical model was developed that allows accurate prediction of TWT cold-test characteristics including operating frequency, interaction impedance, and attenuation. This computational model, which was developed at the NASA Lewis Research Center, allows TWT designers to obtain a more accurate value of interaction impedance than is possible using experimental methods. Obtaining helical slow-wave circuit interaction impedance is an important part of the design process for a TWT because it is related to the gain and efficiency of the tube. This impedance cannot be measured directly; thus, conventional methods involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit and obtaining the difference in resonant frequency between the perturbed and unperturbed circuits. A mathematical relationship has been derived between this frequency difference and the interaction impedance (ref. 1). However, because of the complex configuration of the helical circuit, deriving this relationship involves several approximations. In addition, this experimental procedure is time-consuming and expensive, but until recently it was widely accepted as the most accurate means of determining interaction impedance. The advent of an accurate three-dimensional helical circuit model (ref. 2) made it possible for Lewis researchers to fully investigate standard approximations made in deriving the relationship between measured perturbation data and interaction impedance. The most prominent approximations made in the analysis were addressed and fully investigated for their accuracy by using the three-dimensional electromagnetic simulation code MAFIA (Solution of Maxwell's Equations by the Finite Integration Algorithm) (refs. 3 and 4). We found that several approximations introduced significant error (ref. 5).

Kory, Carol L.↗

Direct solar-pumped iodine laser amplifier

This semiannual progress report covers the period from March 1, 1987 to September 30, 1987 under NASA grant NAG1-441 entitled 'Direct solar-pumped iodine laser amplifier'. During this period Nd:YAG and Nd:Cr:GSGG crystals have been tested for the solar-simulator pumped cw laser, and loss mechanisms of the laser output power in a flashlamp-pumped iodine laser also have been identified theoretically. It was observed that the threshold pump-beam intensities for both Nd:YAG and Nd:Cr:GSGG crystals were about 1000 solar constants, and the cw laser operation of the Nd:Cr:GSGG crystal was more difficult than that of the Nd:YAG crystal under the solar-simulator pumping. The possibility of the Nd:Cr:GSGG laser operation with a fast continuously chopped pumping was also observed. In addition, good agreement between the theoretical calculations and the experimental data on the loss mechanisms of a flashlamp-pumped iodine laser at various fill pressures and various lasants was achieved.

Han, Kwang S.↗

External electro-optic probing of millimeter-wave integrated circuits

An external, noncontact electro-optic measurement system, designed to operate at the wafer level with conventional wafer probing equipment and without any special circuit preparation, has been developed. Measurements have demonstrated the system's ability to probe continuous and pulsed signals on microwave integrated circuits on arbitrary substrates with excellent spatial resolution. Experimental measurements on a variety of digital and analog circuits, including a GaAs selectively-doped heterostructure transistor prescaler, an NMOS silicon multiplexer, and a GaAs power amplifier MMIC are reported.

Whitaker, J. F.↗

External electro-optic probing of millimeter-wave integrated circuits

An external, noncontact electro-optic measurement system, designed to operate at the wafer level with conventional wafer probing equipment and without any special circuit preparation, has been developed. Measurements have demonstrated the system's ability to probe continuous and pulsed signals on microwave integrated circuits on arbitrary substrates with excellent spatial resolution. Experimental measurements on a variety of digital and analog circuits, including a GaAs selectively-doped heterostructure transistor prescaler, an NMOS silicon multiplexer, and a GaAs power amplifier MMIC are reported.

Whitaker, J. F.↗

THz Hot-Electron Photon Counter

We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

radiation detectors↗