Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear level density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AGC-4 Specimen Post-Irradiation Examination Data Interim Report

This interim report documents preliminary results of the post-irradiation examination material property testing from the fourth advanced graphite creep (AGC), AGC 4, capsule specimens. This is the fourth of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades to moderate dose levels (=7 dpa). The AGC 4 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 800°C and to a peak dose of 8 dpa. Half of the AGC-4 specimens were subjected to compressive stresses to induce irradiation creep. Post-irradiation testing and measurement results are reported with the exception of thermal testing, which is still in progress, and irradiation mechanical strength testing. Additionally, some specimens initially deemed too hot to be examined in the ART Graphite laboratory may still be measured. The data reported includes specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and dimensional data necessary to derive density, elastic constants (Young?s modulus, shear modulus, and Poisson?s ratio) from ultrasonic time of flight velocity measurements, Young?s modulus from the fundamental frequency of vibration, and electrical resistivity. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to the irradiation environment and applied load on the specimens, will be discussed later in AGC 4 post-irradiation examination analysis reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Selective polarization of nuclear spins in a wire-like quantum Hall system

Nuclear spins are polarized selectively in a mesoscopic wire-like quantum Hall system by using the fractional quantum Hall system at Landau level filling factor nu = 2/3. The nuclear spin polarized region is limited by setting the filling factor in the wire to 2/3, while leaving the filling factor in the bulk away from 2/3. The longitudinal relaxation rate of selectively polarized nuclear spins probes electron spin properties in the wire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The relationship between anatomic noise and volumetric breast density for digital mammography

Purpose: The appearance of parenchymal/stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, {beta}. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences the texture and appearance of the patterns formed in a mammogram. Here, a large study is performed to investigate the variations in {beta} in a clinical population and to indicate the relationship between {beta} and breast density. Methods: From a set of 2686 cranio-caudal normal screening mammograms, the parameter {beta} was extracted from log-log fits to the Wiener spectrum over the range 0.15-1 mm{sup -1}. The Wiener spectrum was calculated from regions of interest in the compression paddle contact region of the breast. An in-house computer program, Cumulus V, was used to extract the volumetric breast density and identify the compression paddle contact regions of the breast. The Wiener spectra were calculated with and without modulation transfer function (MTF) correction to determine the impact of VBD on the intrinsic anatomic noise. Results: The mean volumetric breast density was 25.5% ({+-}12.6%) over all images. The mean {beta} following a MTF correction which decreased the {beta} slightly ( Almost-Equal-To -0.08) was found to be 2.87. Varying the maximum of the spatial frequency range of the fits from 0.7 to 1.0, 1.25 or 1.5 mm{sup -1} showing small decreases in the result, although the effect of the quantum noise power component on reducing {beta} was clearly observed at 1.5 mm{sup -1}. Conclusions: The texture parameter, {beta}, was found to increase with VBD at low volumetric breast densities with an apparent leveling off at higher densities. The relationship between {beta} and VBD measured here can be used to create probabilistic models for computer simulations of detectability. As breast density is a known risk predictor for breast cancer, the correlation between {beta} and VBD suggests that {beta} may provide predictive information and this will be investigated in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using inertial fusion implosions to measure the T + He 3 fusion cross section at nucleosynthesis-relevant energies

Light nuclei were created during big-bang nucleosynthesis (BBN). Standard BBN theory, using rates inferred from accelerator-beam data, cannot explain high levels of 6 Li in low-metallicity stars. Using high energy-density plasmas we measure the T( 3 He,γ) 6 Li reaction rate, a candidate for anomalously high 6 Li production; we find that the rate is too low to explain the observations, and different than values used in common BBN models. In conclusion, this is the first data directly relevant to BBN, and also the first use of laboratory plasmas, at comparable conditions to astrophysical systems, to address a problem in nuclear astrophysics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular clouds in starburst galaxy nuclei

New CO observations of a complete sample of starburst galaxies are presented in order to determine the range of molecular gas masses and star-formation efficiencies that characterize these systems. The properties of the galaxies in the sample are given, and the H-alpha and R-band CCD images for six of the galaxies are shown. The novel feature of this study is that the galaxies in this study are infrared selected as opposed to optically selected. They exhibit levels of nuclear star formation activity which are comparable to the starburst galaxies M82 and NGC 253. A subset of galaxies with unusually narrow CO line widths, high star-formation efficiencies, and compact 10-micron distributions is revealed. It is proposed that, if gas distributions in these galaxies are also compact, as the narrow linewidths suggest, the high yields of massive stars per unit mass of molecular gas may be attributed to a star-formation mechanism which becomes more efficient as the gas density increases.

Young, Judith S.↗

The Far-Infrared Spectrum of Arp 220

ISO/LWS grating observations of the ultraluminous infrared galaxy Arp 220 shows absorption in molecular lines of OH, H(sub 2)O, CH, NH, and NH(sub 3), as well as in the [O I] 63 micron line and emission in the [C II] 158 micron line. We have modeled the continuum and the emission/absorption of all observed features by means of a non-local radiative transfer code. The continuum from 25 to 1300 microns is modeled as a warm (106 K) nuclear region that is optically thick in the far-infrared, attenuated by an extended region (size 2") that is heated mainly through absorption of nuclear infrared radiation. The molecular absorption in the nuclear region is characterized by high excitation due to the high infrared radiation density. The OH column densities are high toward the nucleus (2 - 6 x 10(exp 17) cm(exp -2)) and the extended region (approximately 2 x 10(exp 17) cm(exp -2)). The H(sub 2)O column density is also high toward the nucleus (2 - 10 x 10(exp 17) cm(exp -2)) and lower in the extended region. The column densities in a halo that accounts for the absorption by the lowest lying levels are similar to what are found in the diffuse clouds toward the star forming regions in the Sgr B2 molecular cloud complex near the Galactic Center. Most notable are the high column densities found for NH and NH(sub 3) toward the nucleus, with values of approximately 1.5 x 10(exp 16) cm(exp -2) and approximately 3 x 10(exp 16) cm(exp -2), respectively, whereas the NH(sub 2) column density is lower than approximately 2 x 10(exp 15) cm(exp -2). A combination of PDRs in the extended region and hot cores with enhanced H(sub 2)O photodissociation and a possible shock contribution in the nuclei may explain the relative column densities of OH and H(sub 2)O, whereas the nitrogen chemistry may be strongly affected by cosmic ray ionization. The [C II] 158 micron line is well reproduced by our models and its deficit relative to the CII/FIR ratio in normal and starburst galaxies is suggested to be mainly a consequence of the dominant non-PDR component of far-infrared radiation, although our models alone cannot rule out extinction effects in the nuclei.

Gonzalez-Alfonso, Eduardo↗

Synchronization of Thomson scattering measurements on MAST using an FPGA based ''Smart'' trigger unit

The MAST Thomson scattering diagnostic has recently been upgraded to make electron density and temperature measurements at 130 points across the 1.5 m diameter of the plasma. The new system is able to take 240 measurements per second using eight Nd:YAG lasers, each running at 30 Hz. The exact firing time of these lasers is adjusted with 100 ns precision using a field programmable gate array based trigger unit. Trigger pulses are produced to fire the lamps of all lasers and the Q switches with the appropriate delay depending on the warm-up status. The lasers may be fired in rapid bursts so as to achieve a high temporal resolution over eight points separated down to the microsecond level. This trigger unit receives optical trigger events and signals from external sources, allowing the trigger sequences to be resynchronized to the start of the plasma pulse and further events during the shot such as the entry of a fuelling pellet or randomly occurring plasma events. This resynchronization of the laser firing sequence allows accurate and reproducible measurements of fast plasma phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-fast charge exchange spectroscopy for turbulent ion temperature fluctuation measurements on the DIII-D tokamak (invited)

A novel two-channel, high throughput, high efficiency spectrometer system has been developed to measure impurity ion temperature and toroidal velocity fluctuations associated with long-wavelength turbulence and other plasma instabilities. The spectrometer observes the emission of the n= 8-7 hydrogenic transition of C{sup +5} ions ({lambda}{sub air}= 529.06 nm) resulting from charge exchange reactions between deuterium heating beams and intrinsic carbon. Novel features include a large, prism-coupled high-dispersion, volume-phase-holographic transmission grating and high-quantum efficiency, high-gain, low-noise avalanche photodiode detectors that sample emission at 1 MHz. This new diagnostic offers an order-of-magnitude increase in sensitivity compared to earlier ion thermal turbulence measurements. Increased sensitivity is crucial for obtaining enough photon statistics from plasmas with much less impurity content. The irreducible noise floor set by photon statistics sets the ultimate sensitivity to plasma fluctuations. Based on the measured photon flux levels for the entire spectral line, photon noise levels for T(tilde sign){sub i}/T{sub i} and V(tilde sign){sub i}/V{sub i} of {approx}1% are expected, while statistical averaging over long data records enables reduction in the detectable plasma fluctuation levels to values less than that. Broadband ion temperature fluctuations are observed to near 200 kHz in an L-mode discharge. Cross-correlation with the local beam emission spectroscopy measurements demonstrates a strong coupling of the density and temperature fields, and enables the cross-phase measurements between density and ion temperature fluctuations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian inference of the incompressibility, skewness and kurtosis of nuclear matter from empirical pressures in relativistic heavy-ion collisions

Within the Bayesian statistical framework we infer the incompressibility K 0 , skewness J 0 and kurtosis Z 0 parameters of symmetric nuclear matter (SNM) at its saturation density ρ 0 using the constraining bands on the pressure in cold SNM in the density range of 1.3ρ 0 to 4.5ρ 0 from transport model analyses of kaon production and nuclear collective flow in relativistic heavy-ion collisions. As the default option assuming the K 0 , J 0 and Z 0 have Gaussian prior probability distribution functions (PDFs) with the means and variances of 235±30, -200±200 and -146±1728 MeV, their posterior most probable values are narrowed down to 192$^{+12}_{-16}$ MeV, -180$^{+100}_{-110}$ MeV and ${\mathrm{200}}_{-250}^{+250}$ at 68% confidence level, respectively. The results are largely independent of the prior PDFs of J 0 and Z 0 used. However, if one adopts the strong belief that the incompressibility K 0 has a uniform prior PDF within its absolute boundary of 220–260 MeV as one can find easily in the literature, the posterior most probable values of K 0 , J 0 and Z 0 shift to ${K}_{0}=22{0}_{-0}^{+6}$ MeV, ${J}_{0}=-39{0}_{-70}^{+60}$ MeV and ${Z}_{0}=60{0}_{-200}^{+200}$ MeV, respectively. While the posterior PDFs of the SNM EOS parameters depend somewhat on the prior PDF of K 0 used, the results from using different prior PDFs are qualitatively consistent. The uncertainties of all three parameters are significantly reduced especially for the J 0 and Z 0 parameters compared to their current values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Semimicroscopic description of isoscalar giant multipole resonances in medium-mass closed-shell nuclei

Main properties of isoscalar giant multipole resonances (up to L=3), including L=0,and 2 overtones, in medium-mass closed-shell nuclei are described within the semimicroscopic particle-hole dispersive optical model. Further, main properties are characterized by the energy-averaged strength distribution, projected (one-body) transition density, and probabilities of direct one-nucleon decay. Calculation results obtained for characteristics of the mentioned resonances in the 48 Ca, 90 Zr, and 132 Sn nuclei are compared with available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic Study of the Triple-{alpha} Reaction

We present a microscopic dynamical study of the reactions involving three {sup 4}He clusters. We show that the much discussed triple-{alpha} linear chain configuration of {sup 12}C is formed with a certain lifetime and subsequently makes a transition to a triangular configuration of {sup 12}C and then to a configuration near the ground state. Time-dependent Hartree-Fock theory coupled with a density constraint is used to study the properties of these configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-Informed Deep Learning-Based Proof-of-Concept Study of a Novel Elastohydrodynamic Seal for Supercritical CO 2 Turbomachinery

Supercritical carbon dioxide (sCO 2 ) power cycles show promising potential of higher plant efficiencies and power densities for a wide range of power generation applications such as fossil fuel power plants, nuclear power production, solar power, and geothermal power generation. sCO 2 leakage through the turbomachinery has been one of the main concerns in such applications. To offer a potential solution, we propose an elastohydrodynamic (EHD) seal that can work at elevated pressures and temperatures with low leakage and minimal wear. The EHD seal has a very simple, sleeve-like structure, wrapping on the rotor with minimal initial clearance at micron levels. Here, in this work, a proof-of-concept study for the proposed EHD seal was presented by using the simplified Reynolds equation and Lame’s formula for the fluid flow in the clearance and for seal deformation, respectively. The set of nonlinear equations was solved by using both the conventional Prediction–Correction (PC) method and modern Physics-Informed Neural Network (PINN). It was shown that the physics-informed deep learning method provided good computational efficiency in resolving the steep pressure gradient in the clearance with good accuracy. The results showed that the leakage rates increased quadratically with working pressures and reached a steady-state at high-pressure values of 15~20 MPa, where Q = 300 g/s at 20 MPa for an initial seal clearance of 255 μm. This indicates that the EHD seal could be tailored to become a potential solution to minimize the sCO 2 discharge in power plants.

30 DIRECT ENERGY CONVERSION↗

Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources

Purpose: Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is corrected to standard atmospheric conditions using the usual temperature and pressure correction factor. Nevertheless, when assessing low energy sources, the ionization chambers may not fulfill that condition and a residual density dependence still remains after correction. In this work, the authors examined the behavior of the PTW 34051 SourceCheck ionization chamber when measuring the air kerma strength of {sup 125}I seeds.Methods: Four different SourceCheck chambers were analyzed. With each one of them, two series of measurements of the air kerma strength for {sup 125}I selectSeed{sup TM} brachytherapy sources were performed inside a pressure chamber and varying the pressure in a range from 747 to 1040 hPa (560 to 780 mm Hg). The temperature and relative humidity were kept basically constant. An analogous experiment was performed by taking measurements at different altitudes above sea level.Results: Contrary to other well-known ionization chambers, like the HDR1000 PLUS, in which the temperature-pressure correction factor overcorrects the measurements, in the SourceCheck ionization chamber they are undercorrected. At a typical atmospheric situation of 933 hPa (700 mm Hg) and 20 °C, this undercorrection turns out to be 1.5%. Corrected measurements show a residual linear dependence on the density and, as a consequence, an additional density dependent correction must be applied. The slope of this residual linear density dependence is different for each SourceCheck chamber investigated. The results obtained by taking measurements at different altitudes are compatible with those obtained with the pressure chamber.Conclusions: Variations of the altitude and changes in the weather conditions may produce significant density corrections, and that effect should be taken into account. This effect is chamber-dependent, indicating that a specific calibration is necessary for each particular chamber. To our knowledge, this correction has not been considered so far for SourceCheck ionization chambers, but its magnitude cannot be neglected in clinical practice. The atmospheric pressure and temperature at which the chamber was calibrated need to be taken into account, and they should be reported in the calibration certificate. In addition, each institution should analyze the particular response of its SourceCheck ionization chamber and compute the adequate correction factors. In the absence of a suitable pressure chamber, a possibility for this assessment is to take measurements at different altitudes, spanning a wide enough air density range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brayton Power Conversion System Study to Advance Technology Readiness for Nuclear Electric Propulsion

Recently, there has been significant interest within the aerospace community to develop space based nuclear power conversion technologies especially for exploring the outer planets of our solar system where the solar energy density is very low. To investigate these technologies NASA awarded several contracts under Project Prometheus, the Nuclear Systems Program. The studies described in this paper were performed under one of those contracts, which was to investigate the use of a nuclear power conversion system based on the closed Brayton cycle (CBC).The investigation performed included BPCS (Brayton Power Conversion System) trade studies to minimize system weight and radiator area and advance the state of the art of BPCS technology. The primary requirements for studies were a power level of 100 kWe (to the PPU), a low overall power system mass and a lifetime of 15 years (10 years full power). For the radiation environment, the system was to be capable of operation in the generic space environment and withstand the extreme environments surrounding Jupiter. The studies defined a BPCS design traceable to NEP (Nuclear Electric Propulsion) requirements and suitable for future missions with a sound technology plan for technology readiness level (TRL) advancement identified. The studies assumed a turbine inlet temperature approx. 100 C above the current the state of the art capabilities with materials issues and related development tasks identified. Analyses and evaluations of six different HRS (heat rejection system) designs and three primary power management and distribution (PMAD) configurations will be discussed in the paper.

Patrick E. Frye↗

Increasing the power density when using inert matrix fuels to reduce production of transuranics

Reducing the production of transuranics is a goal of most advanced nuclear fuel cycles. One way to do this is to recycle the transuranics into the same reactors that are currently producing them using an inert matrix fuel. In previous work we have modeled such a reactor where 72%, of the core is comprised of standard enriched uranium fuel pins, with the remaining 28% fuel made from Yttria stabilized zirconium, in which transuranics are loaded. A key feature of this core is that all of the transuranics produced by the uranium fuel assemblies are later burned in inert matrix fuel assemblies. It has been shown that this system can achieve reductions in transuranic waste of more than 86%. The disadvantage of such a system is that the core power rating must be significantly lower than a standard pressurized water reactor. One reason for the lower power is that high burnup of the uranium fuel precludes a critical level of reactivity at the end of the campaign. Increasing the uranium enrichment and changing the pin pitch are two ways to increase burnup while maintaining criticality. In this paper we use MCNPX and a linear reactivity model to quantify the effect of these two parameters on the end of campaign reactivity. Importantly, we show that in the region of our proposed reactor, enrichment increases core reactivity by 0.02 per percent uranium 235 and pin pitch increases reactivity by 0.02 per mm. Reactivity is lost at a rate of 0.005 per MWd/kgIHM uranium burnup. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Note: Homogeneity of Gafchromic EBT2 film

Purpose: The self-developing Gafchromic EBT film is a radiochromic film, widely used for relative photon dosimetry. Recently, the manufacturer has replaced the well-investigated EBT film by the new Gafchromic EBT2 film. It has the same sensitive component and, in addition, it contains a yellow marker dye in order to protect the film against ambient light exposure and to serve as a base for corrections of small differences in film response. Furthermore, the configuration of the film layers as well as the binder material have been changed in comparison to the EBT film. When investigating the properties of EBT2 film, all characteristics were found to be similar to those of EBT film, except for the film response homogeneity. Thus, in this article special focus was put on examining the homogeneity of EBT2 film. Methods: A scan protocol established for EBT film and published previously was used. The uniformity of the film coloration was investigated for unirradiated and irradiated EBT2 film sheets. The dose response of EBT2 film was measured and the influence of film inhomogeneities on dose determination was evaluated. Results: Inhomogeneities in pixel values of up to {+-}3.7% within one film were detected. The relative inhomogeneities were found to be approximately independent of the dose. Nonuniformities of the film response lead to uncertainties in dose determination of {+-}8.7% at 1 Gy. When using net optical densities for dose calibration, uncertainties in dose determination amount to more than {+-}6%. Conclusions: EBT2 films from the lot investigated in this study show response inhomogeneities, which lead to uncertainties in dose determination exceeding the commonly accepted tolerance levels. It is important to test further EBT2 lots regarding homogeneity before using the film in clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient calculation of nuclear spin-rotation constants from auxiliary density functional theory

The computation of the spin-rotation tensor within the framework of auxiliary density functional theory (ADFT) in combination with the gauge including atomic orbital (GIAO) scheme, to treat the gauge origin problem, is presented. For the spin-rotation tensor, the calculation of the magnetic shielding tensor represents the most demanding computational task. Employing the ADFT-GIAO methodology, the central processing unit time for the magnetic shielding tensor calculation can be dramatically reduced. In this work, the quality of spin-rotation constants obtained with the ADFT-GIAO methodology is compared with available experimental data as well as with other theoretical results at the Hartree-Fock and coupled-cluster level of theory. It is found that the agreement between the ADFT-GIAO results and the experiment is good and very similar to the ones obtained by the coupled-cluster single-doubles-perturbative triples-GIAO methodology. With the improved computational performance achieved, the computation of the spin-rotation tensors of large systems or along Born-Oppenheimer molecular dynamics trajectories becomes feasible in reasonable times. Three models of carbon fullerenes containing hundreds of atoms and thousands of basis functions are used for benchmarking the performance. Furthermore, a theoretical study of temperature effects on the structure and spin-rotation tensor of the H{sup 12}C–{sup 12}CH–DF complex is presented. Here, the temperature dependency of the spin-rotation tensor of the fluorine nucleus can be used to identify experimentally the so far unknown bent isomer of this complex. To the best of our knowledge this is the first time that temperature effects on the spin-rotation tensor are investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗