Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Power line communication system and method of auto-commissioning system nodes

A power line communication system and method permit auto-commissioning of multiple device control modules on a DC power line during the power up of the system. Device control modules associated with the peripheral devices are powered up sequentially and a unique address is assigned to each device controller when it is powered up. The device control modules have a unique circuit configuration that allows the use of inexpensive and mostly passive components. The cost effectiveness of the device controller design becomes particularly significant in applications, such as multi-panel OLED lighting fixtures, with high node counts.

97 MATHEMATICS AND COMPUTING↗

Dynamic concurrent learning method to neutralize cyber attacks and faults for industrial asset monitoring nodes

Input signals may be received from monitoring nodes of the industrial asset, each input signal comprising time series data representing current operation. A neutralization engine may transform the input signals into feature vectors in feature space, each feature vector being associated with one of a plurality of overlapping batches of received input signals. A dynamic decision boundary may be generated based on the set of feature vectors, and an abnormal state of the asset may be detected based on the set of feature vectors and a predetermined static decision boundary. An estimated neutralized value for each abnormal feature value may be calculated based on the dynamic decision boundary and the static decision boundary such that a future set of feature vectors will be moved with respect to the static decision boundary. An inverse transform of each estimated neutralized value may be performed to generate neutralized signals comprising time series data that are output.

97 MATHEMATICS AND COMPUTING↗

Large scale multi-node simulations of $\mathbb{Z}_2$ gauge theory quantum circuits using Google Cloud Platform

Simulating quantum field theories on a quantum computer is one of the most exciting fundamental physics applications of quantum information science. Dynamical time evolution of quantum fields is a challenge that is beyond the capabilities of classical computing, but it can teach us important lessons about the fundamental fabric of space and time. Whether we may answer scientific questions of interest using near-term quantum computing hardware is an open question that requires a detailed simulation study of quantum noise. Here we present a large scale simulation study powered by a multi-node implementation of qsim using the Google Cloud Platform. We additionally employ newly-developed GPU capabilities in qsim and show how Tensor Processing Units -- Application-specific Integrated Circuits (ASICs) specialized for Machine Learning -- may be used to dramatically speed up the simulation of large quantum circuits. We demonstrate the use of high performance cloud computing for simulating $\mathbb{Z}_2$ quantum field theories on system sizes up to 36 qubits. We find this lattice size is not able to simulate our problem and observable combination with sufficient accuracy, implying more challenging observables of interest for this theory are likely beyond the reach of classical computation using exact circuit simulation.

Gustafson, Erik↗

The SEMATECH Berkeley microfield exposure tool: learning a the 22-nm node and beyond

Microfield exposure tools (METs) continue to playa dominant role in the development of extreme ultraviolet (EUV) resists. One of these tools is the SEMATECH Berkeley 0.3-NA MET operating as a SEMATECH resist and mask test center. Here we present an update summarizing the latest resist test and characterization results. The relatively small numerical aperture and limited illumination settings expected from 1st generation EUV production tools make resist resolution a critical issue even at the 32-nm node. In this presentation, sub 22 nm half pitch imaging results of EUV resists are reported. We also present contact hole printing at the 30-nm level. Although resist development has progressed relatively well in the areas of resolution and sensitivity, line-edge-roughness (LER) remains a significant concern. Here we present a summary of recent LER performance results and consider the effect of system-level contributors to the LER observed from the SEMA TECH Berkeley microfield tool.

36 MATERIALS SCIENCE↗

Mask roughness and its implications for LER at the 22- and 16-nm nodes

Line-edge roughness (LER) remains the most significant challenge facing the development of extreme ultraviolet (EUV) resist. The mask, however, has been found to be a significant contributor to image-plane LER. This has long been expected based on modeling and has more recently been demonstrated experimentally. Problems arise from both mask-absorber LER as well as mask multilayer roughness leading to random phase variations in the reflected beam and consequently speckle. Understanding the implications this has on mask requirements for the 22-nm half pitch node and below is crucial. Modeling results indicate a replicated surface roughness (RSR) specification of 50 pm and a ruthenium capping layer roughness specification of 440 pm. Moreover, modeling indicates that it is crucial to achieve the current ITRS specifications for mask absorber LER which is significantly smaller than current capabilities.

36 MATERIALS SCIENCE↗

Resilient Node Cluster Analysis Tool (ReNCAT) v. 2.1

SAND2021-6533 O The Resilient Node Cluster Analysis Tool (ReNCAT) identifies portions of a power distribution network that can be isolated into microgrids in order to supply services to a community during disruptive events. Candidate microgrid configurations are evaluated using a burden metric, a measure of the relative effort community members must expend to acquire services required for their well-being. Results present multiple candidate configurations, each with a different balance of cost and burden. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Melander, Darryl↗

Whole-Pelvis Radiotherapy in Combination With Interstitial Brachytherapy: Does Coverage of the Pelvic Lymph Nodes Improve Treatment Outcome in High-Risk Prostate Cancer?

Purpose: To compare biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) rates among high-risk prostate cancer patients treated with brachytherapy and supplemental external beam radiation (EBRT) using either a mini-pelvis (MP) or a whole-pelvis (WP) field. Methods and Materials: From May 1995 to October 2005, 186 high-risk prostate cancer patients were treated with brachytherapy and EBRT with or without androgen-deprivation therapy (ADT). High-risk prostate cancer was defined as a Gleason score of >=8 and/or a prostate-specific antigen (PSA) concentration of >=20 ng/ml. Results: With a median follow-up of 6.7 years, the 10-year bPFS, CSS, and OS rates for the WP vs. the MP arms were 91.7% vs. 84.4% (p = 0.126), 95.5% vs. 92.6% (p = 0.515), and 79.5% vs. 67.1% (p = 0.721), respectively. Among those patients who received ADT, the 10-year bPFS, CSS, and OS rates for the WP vs. the MP arms were 93.6% vs. 90.1% (p = 0.413), 94.2% vs. 96.0% (p = 0.927), and 73.7% vs. 70.2% (p = 0.030), respectively. Among those patients who did not receive ADT, the 10-year bPFS, CSS, and OS rates for the WP vs. the MP arms were 82.4% vs. 75.0% (p = 0.639), 100% vs. 88% (p = 0.198), and 87.5% vs. 58.8% (p = 0.030), respectively. Based on multivariate analysis, none of the evaluated parameters predicted for CSS, while bPFS was best predicted by ADT and percent positive biopsy results. OS was best predicted by age and percent positive biopsy results. Conclusions: For high-risk prostate cancer patients receiving brachytherapy, there is a nonsignificant trend toward improved bPFS, CSS, and OS rates when brachytherapy is given with WPRT. This trend is most apparent among ADT-naive patients, for whom a significant improvement in OS was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elective Lymph Node Irradiation With Intensity-Modulated Radiotherapy: Is Conventional Dose Fractionation Necessary?

Purpose: Intensity-modulated radiation therapy (IMRT) is the standard of care for head-and-neck cancer (HNC). We treated patients with HNC by delivering either a moderate hypofractionation (MHF) schedule (66 Gy at 2.2 Gy per fraction to the gross tumor [primary and nodal]) with standard dose fractionation (54-60 Gy at 1.8-2.0 Gy per fraction) to the elective neck lymphatics or a conventional dose and fractionation (CDF) schedule (70 Gy at 2.0 Gy per fraction) to the gross tumor (primary and nodal) with reduced dose to the elective neck lymphatics. We analyzed these two cohorts for treatment outcomes. Methods and Materials: Between November 2001 and February 2009, 89 patients with primary carcinomas of the oral cavity, larynx, oropharynx, hypopharynx, and nasopharynx received definitive IMRT with or without concurrent chemotherapy. Twenty patients were treated using the MHF schedule, while 69 patients were treated with the CDF schedule. Patient characteristics and dosimetry plans were reviewed. Patterns of failure including local recurrence (LR), regional recurrence (RR), distant metastasis (DM), disease-free survival (DFS), overall survival (OS), and toxicities, including rate of feeding tube placement and percentage of weight loss, were reviewed and analyzed. Results: Median follow-up was 31.2 months. Thirty-five percent of patients in the MHF cohort and 77% of patients in the CDF cohort received chemotherapy. No RR was observed in either cohort. OS, DFS, LR, and DM rates for the entire group at 2 years were 89.3%, 81.4%, 7.1%, and 9.4%, respectively. Subgroup analysis showed no significant differences in OS (p = 0.595), DFS (p = 0.863), LR (p = 0.833), or DM (p = 0.917) between these two cohorts. Similarly, no significant differences were observed in rates of feeding tube placement and percentages of weight loss. Conclusions: Similar treatment outcomes were observed for MHF and CDF cohorts. A dose of 50 Gy at 1.43 Gy per fraction may be sufficient to electively treat low-risk neck lymphatics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 1-2 Study of Stereotactic Ablative Radiotherapy Including Regional Lymph Node Irradiation in Patients With High-Risk Prostate Cancer (SATURN): Early Toxicity and Quality of Life

Five-fraction stereotactic ablative radiation therapy appears to be gaining popularity in treatment of prostate cancer, but it has not been extensively tested in the context of pelvic radiation. The objective of this prospective prostate and pelvic SABR study is to report the acute toxicity, late toxicity, and quality of life (QoL) after study completion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Mediastinal and Hilar Lymph Node Metastases

Stereotactic body radiation therapy (SBRT) to metastatic mediastinal and hilar lymphadenopathy (MHL) is challenging owing to the proximity of centrally located organs-at-risk. As limited data exist on the safety and efficacy of SBRT for MHL, a retrospective review of clinical outcomes was conducted from a large academic center.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal Mammary Lymph Node Irradiation Contributes to Heart Dose in Breast Cancer

We assessed the impact of internal mammary chain radiotherapy (IMC RT) to the radiation dose received by the heart in terms of heart dose-volume histogram (DVH). Thirty-six consecutive breast cancer patients presenting with indications for IMC RT were enrolled in a prospective study. The IMC was treated by a standard conformal RT technique (50 Gy). For each patient, a cardiac DVH was generated by taking into account the sole contribution of IMC RT. Cardiac HDV were compared according to breast cancer laterality and the type of previous surgical procedure, simple mastectomy or breast conservative therapy (BCT). The contribution of IMC RT to the heart dose was significantly greater for patients with left-sided versus right-sided tumors (13.8% and 12.8% for left-sided tumors versus 3.9% and 4.2% for right-sided tumors in the BCT group and the mastectomy group, respectively; p < 0.0001). There was no statistically significant difference in IMC contribution depending on the initial surgical procedure. IMC RT contributes to cardiac dose for both left-sided and right-sided breast cancers, although the relative contribution is greater in patients with left-sided tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integration of Thermoelectric Generator and Wireless Sensor Node Simulators

This report focuses on integrating TEG and WSN simulators with DC-DC converter as an interface. Here DC stands for direct current. DC-DC converter is essential to balance a wide range of analog, digital, and radio loads acting on the energy source. Also, the voltage level generated by TEGs under varying temperature conditions could be low, irregular, and insufficient to operate WSN, therefore DC-DC is required to boost up the voltage to a desired level. Most of the main problems of DC-DC converters used in TEG system are related to impedance matching between the internal resistance of TEG and the input resistance of DC-DC converter. This report would address the issue associated with dynamic impedance matching under varying temperature conditions in the effort to integrate TEG and WSN. In this effort, dynamic impedance matching algorithms like perturb and observe (P&O) and extremum seeking control (ESC) algorithms will de implemented and compared to achieve maximum peak power tracking (MPPT). In addition, the report will summarize the experimental study performed at BSU on profiling behavior of WSN prototype.

24 POWER TRANSMISSION AND DISTRIBUTION↗