Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the Migdal effect in semiconductors for dark matter detection

The Migdal effect has received much attention from the dark matter direct detection community, in particular due to its power in setting leading limits on sub-GeV particle dark matter. However, it is crucial to obtain experimental confirmation of the Migdal effect through nuclear scattering using Standard Model probes. In this work, we extend existing calculations of the Migdal effect to the case of neutron-nucleus scattering, with a particular focus on neutron scattering angle distributions in silicon. We identify kinematic regimes wherein the assumptions present in current calculations of the Migdal effect hold for neutron scattering and demonstrate that these include viable neutron calibration schemes. We then apply this framework to propose an experimental strategy to measure the Migdal effect in cryogenic silicon detectors using an upgrade to the NEXUS facility at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen Diffusivity Measurements of YH 1.87 Moderator Material with Incoherent Quasielastic Neutron Scattering

Yttrium hydride is an optimal choice of moderator material for thermal neutron spectrum reactors requiring small core volumes. The Transformation Challenge Reactor (TCR) program at Oak Ridge National Laboratory (ORNL) aims to develop an additively manufactured microreactor core by leveraging recent advances in materials, manufacturing, data analytics, and high-fidelity modeling and simulation. Yttrium hydride was selected as the moderator material for TCR due to its high moderating power, which enables the spatially efficient reactor design and thermal stability that is superior when compared with zirconium hydride. Hydrogen desorption from yttrium hydride is expected at elevated temperatures, posing safety and performance concerns. As a lifetime component in advanced reactors, appropriate strategies to mitigate hydrogen release from yttrium hydride over long-term reactor operation are required. Understanding hydrogen mobility in yttrium hydride provides the scientific basis for developing a hydrogen barrier for hydride moderator and predicting the hydrogen redistribution within the material during various operational conditions. This study investigated the hydrogen motion in YH 1.87 as a function of temperature ranging from 200 to 1,173 K using incoherent quasielastic neutron scattering (IQNS) at the Spallation Neutron Source (SNS). The results are presented and discussed in terms of hydrogen self-diffusion coefficients, activation energy for translational hydrogen motion, and hydrogen jump distances. Based on the IQNS data, YH 1.87 is found to be stable at high temperatures with no translational H motion below 1,023 K within the IQNS detection limits. In the temperature range of 1,073–1,173 K, hydrogen diffusivity in YH 1.87 is $D = 4.57 X 10^{⁻3} [m^2/s] exp (⁻\frac{1.73[eV]}{RT}$). The hydrogen concentration’s dependence on hydrogen diffusivity is also discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Critical thermonuclear reactions in classical novae and type I X-ray bursts

The goal of this project was to experimentally constrain the nuclear reaction rates whose uncertainties have the largest impact on models of classical novae and Type-I X-ray bursts. These astrophysical events occur when a white dwarf or neutron star, respectively, accretes hydrogen and helium from a companion star until a thermonuclear runaway ensues. The primary reactions of interest to this project for novae and X-ray bursts are 30 P(ρ,γ) 31 S and 15 O(α,γ) 19 Ne. The project methodology was to develop a new radiation detection system in two phases to measure the low-energy beta-delayed particle emissions of 31 Cl and 20 Mg at the National Superconducting Cyclotron Laboratory (NSCL) in order to constrain these two reaction rates. In particular, a gas-filled charged-particle detector was to be designed, constructed and operated, in concert with the SeGA array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Out-of-Plane Sulfur Distortions in the Bi4O4S3 Superconductor

The local atomic structure of the non-magnetic layered superconductor Bi4O4S3 was investigated using neutron diffraction and pair density function (PDF) analysis. Although on average, the crystal structure is well ordered, evidence for local, out–of–plane sulfur distortions is provided, which may act as a conduit for charge transfer from the SO4 blocks into the superconducting BiS2 planes. In contrast with LaO1−xFxBiS2, no sulfur distortions were detected in the planes, which indicates that charge density wave fluctuations are not supported in Bi4O4S3.

Philip, Sharon S. (ORCID:000000031055718X)↗

Black hole–neutron star mergers: The first mass gap and kilonovae

Observations of X-ray binaries indicate a dearth of compact objects in the mass range from ~2 –5 M ⊙ . The existence of this (first mass) gap has been used to discriminate between proposed engines behind core-collapse supernovae. From LIGO/Virgo observations of binary compact remnant masses, several candidate first mass gap objects, either neutron stars (NSs) or black holes (BHs), were identified during the O3 science run. Motivated by these new observations, we study the formation of BH-NS mergers in the framework of isolated classical binary evolution, using population synthesis methods to evolve large populations of binary stars (Population I and II) across cosmic time. We present results on the NS to BH mass ratios (q = M NS /M BH ) in merging systems, showing that although systems with a mass ratio as low as q = 0.02 can exist, typically BH-NS systems form with moderate mass ratios q = 0.1 –0.2. If we adopt a delayed supernova engine, we conclude that ~30% of BH-NS mergers may host at least one compact object in the first mass gap (FMG). Even allowing for uncertainties in the processes behind compact object formation, we expect the fraction of BH-NS systems ejecting mass during the merger to be small (from ~0.6 –9%). In our reference model, we assume: (i) the formation of compact objects within the FMG, (ii) natal NS/BH kicks decreased by fallback, (iii) low BH spins due to Tayler-Spruit angular momentum transport in massive stars. We find that ≲1% of BH-NS mergers will have any mass ejection and about the same percentage will produce kilonova bright enough to have a chance of being detected with a large (Subaru-class) 8 m telescope. Interestingly, all these mergers will have both a BH and an NS in the FMG.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic nanodomains dictate macroscopic properties in lead halide perovskites

Lead halide perovskites have emerged as promising materials for solar energy conversion and X-ray detection owing to their remarkable optoelectronic properties. However, the microscopic origins of their superior performance remain unclear. Here we show that low-symmetry dynamic nanodomains present in the high-symmetry average cubic phases, whose characteristics are dictated by the A-site cation, govern the macroscopic behaviour. We combine X-ray diffuse scattering, inelastic neutron spectroscopy, hyperspectral photoluminescence microscopy and machine-learning-assisted molecular dynamics simulations to directly correlate local nanoscale dynamics with macroscopic optoelectronic response. Our approach reveals that methylammonium-based perovskites form densely packed, anisotropic dynamic nanodomains with out-of-phase octahedral tilting, whereas formamidinium-based systems develop sparse, isotropic, spherical nanodomains with in-phase tilting, even when crystallography reveals cubic symmetry on average. We demonstrate that these sparsely distributed isotropic nanodomains present in formamidinium-based systems reduce electronic dynamic disorder, resulting in a beneficial optoelectronic response, thereby enhancing the performance of formamidinium-based lead halide perovskite devices. By elucidating the influence of the A-site cation on local dynamic nanodomains, and consequently, on the macroscopic properties, we propose leveraging this relationship to engineer the optoelectronic response of these materials, propelling further advancements in perovskite-based photovoltaics, optoelectronics and X-ray imaging.

Materials Science↗

MeV Gamma Rays from Fission: A Distinct Signature of Actinide Production in Neutron Star Mergers

Neutron star mergers (NSMs) are the first verified sites of rapid neutron capture (r-process) nucleosynthesis, and could emit gamma rays from the radioactive isotopes synthesized in the neutron-rich ejecta. These MeV gamma rays may provide a unique and direct probe of the NSM environment as well as insight into the nature of the r process, just as observed gammas from the 56 Ni radioactive decay chain provide a window into supernova nucleosynthesis. In this work, we include the photons from fission processes for the first time in estimates of the MeV gamma-ray signal expected from an NSM event. We consider NSM ejecta compositions with a range of neutron richness and find a dramatic difference in the predicted signal depending on whether or not fissioning nuclei are produced. The difference is most striking at photon energies above ~3.5 MeV and at a relatively late time, several days after the merger event, when the ejecta is optically thin. We estimate that a Galactic NSM could be detectable by a next generation gamma-ray detector such as AMEGO in the MeV range, up to ~104 days after the merger, if fissioning nuclei are robustly produced in the event.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlative STEM-APT characterization of radiation-induced segregation and precipitation of in-service BWR 304 stainless steel

In this study, radiation induced segregation and precipitation phenomena in an in-service boiling water reactor 304 stainless steel component were investigated using directly correlated 3D-atom probe tomography and scanning transmission electron microscopy. Significant quantitative differences in measured segregation at grain boundaries were found between the atom probe and energy dispersive spectroscopy measurements of the exact same locations. In particular, a much stronger Si segregation (~10 atomic% via atom probe versus ~4 atomic% via electron microscopy) and different Cr profile shapes were detected that are critical to models of radiation induced segregation and stress corrosion cracking behavior. These quantitative differences highlight the need for comparative microscopy and critical evaluation of limitations in each analytical method. Elemental segregation to dislocations and conjoined-clusters were also highlighted by atom probe; confirming and expanding upon what has been observed in test reactor neutron and accelerator-based ion irradiations.

36 MATERIALS SCIENCE↗

Complete β-decay patterns of 142 Cs, 142 Ba, and 142 La determined using total absorption spectroscopy

Background: The β decays of fission products produced in nuclear fuel are important for nuclear energy applications and fundamental science of reactor antineutrinos. In particular, nuclear reactor safety is related to the decay modes of radioactive neutron-rich nuclei, primarily via the emission of γ rays, neutrons, and electrons. Additionally nuclear reactors are the most powerful man-made source of antineutrinos emitted during the β decay of fission products. These antineutrinos are used to inspect fundamental properties of leptons as well as informing reactor operation. However, the majority of data on complex decays of fission products collected in the evaluated nuclear data repositories like Evaluated Nuclear Structure Data File (ENSDF) and Evaluated Nuclear Data Files (ENDF) are based on low-efficiency and often incomplete measurements resulting in questionable reference reactor antineutrino flux predictions, see the analysis by [Nichols, J. Nucl. Sci. Technol. 52, 17 (2015)]. Various assessments like the one done under the auspices of the [Yoshida et al., Assessment of Fission Product Decay Data for Decay Heat Calculations: A report by the Working Party on International Evaluation Co-operation of the Nuclear Energy Agency Nuclear Science Committee (Nuclear Energy Agency, Organization for Economic Co-operation and Development, Paris, France, 2007), Vol. 25], as well as by [Sonzogni, Johnson, and McCutchan, Phys. Rev. C 91, 011301(R) (2015)] and [Dwyer and Langford, Phys. Rev. Lett. 114, 012502 (2015)], list the A = 142 isobars with high cumulative fission yield among the important nuclei where data for reactor decay heat and/or antineutrino production should be verified and/or improved. Purpose: Here, our goal is to improve the quality of β -decay measurements and evaluate the impact of modified decay schemes on reactor decay heat and antineutrino energy spectra, for fission products along the A = 142 isobaric chain. This work is an in depth follow-up on [Rasco et al., Phys. Rev. Lett. 117, 092501 (2016)]. which presented briefly the impact of the corrected decay scheme of 142 Cs . Here, we extend the data to full isobaric decay chain including the daughter nuclei, 142 Ba and 142 La, and present more details on the 142 Cs results. Method: The decays of neutron-rich isobars of mass A = 142 produced by means of proton-induced fission of 238 U were measured using the Modular Total Absorption Spectrometer (MTAS) array on-line at the mass separator and Tandem accelerator at Oak Ridge National Laboratory. Results: The β -decay schemes for 142 Cs and 142 La were modified with respect to the nuclear data repositories. A small β-delayed neutron branching ratio for 142 Cs emitter was remeasured as $0.10^{+5}_{–3}% %. Improved precision on the measured half-lives is reported. Small corrections to the low-energy decay of 142 Ba are made. The β-decay patterns for 142 La and 142 Cs are presented. The decay heat release and cross section for the detection of reactor antineutrinos are deduced and compared to earlier results. Conclusions: The β-feeding pattern for 142 Cs having decay energy value $Q_β$ of over 7 MeV was substantially modified with respect to the current ENSDF entry. Smaller changes were encountered for 142 La, but since this A = 142 isobar also has a large cumulative yield in fission, the changes influence both decay heat and the antineutrino spectra. The previously known β intensities for 142 Ba decay ($Q_β$ value of 2.2 MeV) were verified and slightly modified. Overall, increased decay heat values and lower flux of antineutrinos interacting with matter are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GW190425: Observation of a Compact Binary Coalescence with Total Mass ~ 3.4 M ⊙

On 2019 April 25, the LIGO Livingston detector observed a compact binary coalescence with signal-to-noise ratio 12.9. The Virgo detector was also taking data that did not contribute to detection due to a low signal-to-noise ratio, but were used for subsequent parameter estimation. The 90% credible intervals for the component masses range from 1.12 to 2.52 M ⊙ (1.46-1.87 M ⊙ if we restrict the dimensionless component spin magnitudes to be smaller than 0.05). These mass parameters are consistent with the individual binary components being neutron stars. However, both the source-frame chirp mass 1.44 +0.02 -0.02 M ⊙ and the total mass 3.4 +0.3 -0.1 M ⊙ of this system are significantly larger than those of any other known binary neutron star (BNS) system. The possibility that one or both binary components of the system are black holes cannot be ruled out from gravitational-wave data. We discuss possible origins of the system based on its inconsistency with the known Galactic BNS population. Under the assumption that the signal was produced by a BNS coalescence, the local rate of neutron star mergers is updated to 250-2810 Gpc -3 yr -1 .

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental determination of precision, resolution, accuracy and trueness of time-of-flight neutron diffraction strain measurements

We discuss a simple statistical analysis which yields the precision, resolution, accuracy and trueness of diffraction-based lattice strain measurements. The procedure consists of measuring the thermal expansion induced in each component of an ideal, non-reacting, two-component, crystalline powder sample in situ. One component, with a high coefficient of thermal expansion (CTE), serves as an internal thermometer. The quantities of interest are obtained by determining the smallest, statistically significant, thermal lattice strain which can be detected through diffraction analysis in the second, low CTE, component in response to controlled temperature changes. This procedure also provides a robust check of the alignment of the diffraction system and is able to reveal the presence of systematic errors. The application of this technique to a time-of-flight engineering diffractometer/strain scanner is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining elastic anisotropy of textured polycrystals using resonant ultrasound spectroscopy

Abstract Polycrystalline materials can have complex anisotropic properties depending on their crystallographic texture and crystal structure. In this study, we use resonant ultrasound spectroscopy (RUS) to nondestructively quantify the elastic anisotropy in extruded aluminum alloy 1100-O, an inherently low-anisotropy material. Further, we show that RUS can be used to indirectly provide a description of the material’s texture, which in the present case is found to be transversely isotropic. By determining the entire elastic tensor, we can identify the level and orientation of the anisotropy originated during extrusion. The relative anisotropy of the compressive (c 11 /c 33 ) and shear (c 44 /c 66 ) elastic constants is 1.5% ± 0.5% and 5.7% ± 0.5%, respectively, where the elastic constants (five independent elastic constants for transversely isotropic) are those associated with the extrusion axis that defines the symmetry of the texture. These results indicate that the texture is expected to have transversely isotropic symmetry. This finding is confirmed by two additional approaches. First, we confirm elastic constants and the degree of elastic anisotropy by direct sound velocity measurements using ultrasonic pulse echo. Second, neutron diffraction (ND) data confirm the symmetry of the bulk texture consistent with extrusion-induced anisotropy, and polycrystal elasticity simulations using the elastic self-consistent model with input from ND textures and aluminum single-crystal elastic constants render similar levels of polycrystal elastic anisotropy to those measured by RUS. We demonstrate the ability of RUS to detect texture-induced anisotropy in inherently low-anisotropy materials. Therefore, as many other common materials have intrinsically higher elastic anisotropy, this technique should be applicable for similar levels of texture, providing an efficient general diagnostic and characterization tool.

36 MATERIALS SCIENCE↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗