Modal vector estimation for closely spaced frequency modes

Techniques for obtaining improved modal vector estimates for systems with closely spaced frequency modes are discussed. In describing the dynamical behavior of a complex structure modal parameters are often analyzed: undamped natural frequency, mode shape, modal mass, modal stiffness and modal damping. From both an analytical standpoint and an experimental standpoint, identification of modal parameters is more difficult if the system has repeated frequencies or even closely spaced frequencies. The more complex the structure, the more likely it is to have closely spaced frequencies. This makes it difficult to determine valid mode shapes using single shaker test methods. By employing band selectable analysis (zoom) techniques and by employing Kennedy-Pancu circle fitting or some multiple degree of freedom (MDOF) curve fit procedure, the usefulness of the single shaker approach can be extended.

Craig, R. R., Jr.↗

MMIC devices for active phased array antennas

The study of printed circuit discontinuities is necessary in order to design, for example, transitions between rectangular waveguides and printed circuits. New developments with respect to the analytical approaches to this problem are discussed. A summary of the progress in the experimental approach is presented. The accurate solution for the modes in various millimeter-wave waveguides is essential in the analysis of many integrated circuit components, such as filters and impedance transformers. Problems associated with the numerical computation of these modes in two frequently used waveguide forms, namely, the finline and microstrip, are presented. The spectral domain method of formulation, with a moment method solution, is considered. This approach can be readily extended to analyze an arbitrary configuration of dielectric and metallized regions in a shielded enclosure. Galerkin's method is used, where the testing and basic functions are the same. It is shown that the mode functions, or eigenfunctions, are more sensitive to errors than the phase constants, or eigenvalues. The approximate mode functions do not satisfy the orthogonality relationship well, resulting in difficulties when these modal solutions are used to form an approximate Green's function or are used in a mode matching analysis.

Mittra, R.↗

A Computational Analysis of Boundary Layer Instability over the BOLT Configuration

The complex boundary layer flow over the BOLT flight configuration is known to exhibit multiple and potentially interacting instability mechanisms. This paper represents a continuation of our numerical investigation of the flow instabilities over the main test surface of the BOLT configuration by using state-of-the-art tools in multidimensional instability analysis. Specifically, the paper extends our previous computations by considering the separate effects of a nonzero angle-of-attack and a nonzero yaw on the modal instability characteristics of the boundary layer streaks adjacent to the minor-axis symmetry plane. At a selected condition from the ascent part of the anticipated flight trajectory, either type of departure from the design condition is shown to have a considerable impact on the structure of the laminar basic state and, hence, also on the amplification characteristics of the instability waves. A broader set of computations, including N-factor predictions for the relevant instabilities, will be presented in the final paper.

Boundary layer transition↗

Active Control of Fan Noise: Feasibility Study: Active Fan Noise Cancellation in the NASA Lewis Active Noise Control Fan Facility - Volume 3

This report describes the Active Noise Cancellation (ANC) System designed by General Electric and tested in the NASA Lewis Research Center's (LERC) 48 inch Active Noise Control Fan (ANCF). The goal of this study is to assess the feasibility of using wall mounted secondary acoustic sources and sensors within the duct of a high bypass turbofan aircraft engine for global active noise cancellation of fan tones. The GE ANC system is based on a modal control approach. A known acoustic mode propagating in the fan duct is canceled using an array of flush-mounted compact sound sources. The canceling modal signal is generated by a modal controller. Inputs to the controller are signals from a shaft encoder and from a microphone array which senses the residual acoustic mode in the duct. The key results are that the (6,0) was completely eliminated at the 920 Hz design frequency and substantially reduced elsewhere. The total tone power was reduced 6.8 dB (out of a possible 9.8 dB). Farfield reductions of 15 dB (SPL) were obtained. The (4,0) and (4,1) modes were reduced simultaneously yielding a 15 dB PWL decrease. The results indicate that global attenuation of PWL at the target frequency was obtained in the aft quadrant using an ANC actuator and sensor system totally contained within the duct. The quality of the results depended on precise mode generation. High spillover into spurious modes generated by the ANC actuator array caused less than optimum levels of PWL reduction. The variation in spillover is believed to be due to calibration procedure, but must be confirmed in subsequent tests.

Pla, Frederic G.↗

Constraining Particle Variation in Lunar Regolith for Simulant Design

Simulants are used by the lunar engineering community to develop and test technologies for In Situ Resource Utilization (ISRU), excavation and drilling, and for mitigation of hazards to machinery and human health. Working with the United States Geological Survey (USGS), other NASA centers, private industry and academia, Marshall Space Flight Center (MSFC) is leading NASA s lunar regolith simulant program. There are two main efforts: simulant production and simulant evaluation. This work requires a highly detailed understanding of regolith particle type, size, and shape distribution, and of bulk density. The project has developed Figure of Merit (FoM) algorithms to quantitatively compare these characteristics between two materials. The FoM can be used to compare two lunar regolith samples, regolith to simulant, or two parcels of simulant. In work presented here, we use the FoM algorithm to examine the variance of particle type in Apollo 16 highlands regolith core and surface samples. For this analysis we have used internally consistent particle type data for the 90-150 m fraction of Apollo core 64001/64002 from station 4, core 60009/60010 from station 10, and surface samples from various Apollo 16 stations. We calculate mean modal compositions for each core and for the group of surface samples and quantitatively compare samples of each group to its mean as a measurement of within-group variance; we also calculate an FoM for every sample against the mean composition of 64001/64002. This gives variation with depth at two locations and between Apollo 16 stations. Of the tested groups, core 60009/60010 has the highest internal variance with an average FoM score of 0.76 and core 64001/64002 has the lowest with an average FoM of 0.92. The surface samples have a low but intermediate internal variance with an average FoM of 0.79. FoM s calculated against the 64001/64002 mean reference composition range from 0.79-0.97 for 64001/64002, from 0.41-0.91 for 60009/60010, and from 0.54-0.93 for the surface samples. Six samples fall below 0.70, and they are also the least mature (i.e., have the lowest I(sub s)/FeO). Because agglutinates are the dominant particle type and the agglutinate population increases with sample maturity (I(sub s)/FeO), the maturity of the sample relative to the reference is a prime determinant of the particle type FoM score within these highland samples.

Schrader, Christian M.↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight on Astronaut Health and Performance

INTRODUCTION Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis missions to the Moon and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive capabilities on one platform without including a treadmill. The European Enhanced Exploration Exercise Device [E4D] is one such apparatus. It is critical to validate the efficacy of using exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the effectiveness of using nominal ISS exercise devices for an entire mission compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS Crewmembers are assigned to one of three groups: 1) Controls (n ≥ 40), who partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), cycling on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS), and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who exercise on the CEVIS and ARED only (n = 8); and 3) Active Group 2, who perform aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both Active groups are not permitted to perform treadmill exercise for the entirety of their flight. Health and performance markers, including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and after spaceflight. RESULTS Fifteen subjects (4 Active [CEVIS + ARED], 11 Control) have been recruited. Data collection is ongoing. CONCLUSIONS This study will assess the efficacy of using exploration exercise modalities, including removing the treadmill exercise capability or exclusively using the E4D, compared to the nominal ISS exercise regimen across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions. Supported by the NASA Human Research Program and NASA Exploration Capabilities

A N Varanoske↗

Aerodynamic damping measurements in a transonic compressor

A method has been developed and demonstrated for the direct measurement of aerodynamic damping in a transonic compressor. The method is based on the inverse solution of the structural dynamic equations of motion of the blade-disk system. The equations are solved inversely to determine the forces acting on the system. If the structural dynamic equations are transformed to multiblade or modal coordinates, the damping can be measured for blade-disk modes, and related to a reduced frequency and interblade phase angle. This method of damping determination was demonstrated using a specially instrumented version of the MIT Transonic Compressor run in the MIT Blowdown Compressor Test Facility. No regions of aeroelastic instability were found. In runs at the operating point, the rotor was aerodynamically excited by a controlled two-per-revolution fixed up-stream disturbance. The disturbance was sharply terminated midway through the test. Analysis of the data in terms of multiblade modes led to a direct measurement of aerodynamic damping for three interblade phase angles.

Crawley, E. F.↗

Periodic control of the individual-blade-control helicopter rotor

Results of an investigation into methods of controller design for an individual helicopter rotor blade in the high forward-flight speed regime are described. This operating condition poses a unique control problem in that the perturbation equations of motion are linear with coefficients that vary periodically with time. The design of a control law was based on extensions to modern multivariate synthesis techniques and incorporated a novel approach to the reconstruction of the missing system state variables. The controller was tested on both an electronic analog computer simulation of the out-of-plane flapping dynamics, and on a four foot diameter single-bladed model helicopter rotor in the M.I.T. 5x7 subsonic wind tunnel at high levels of advance ratio. It is shown that modal control using the IBC concept is possible over a large range of advance ratios with only a modest amount of computational power required.

Mckillip, R. M., Jr.↗

Evaluation of sensor placement algorithms for on-orbit identification of space platforms

Anticipating the construction of the international space station, on-orbit modal identification of space platforms through optimally placed accelerometers is an area of recent activity. Unwanted vibrations in the platform could affect the results of experiments which are planned. Therefore, it is important that sensors (accelerometers) be strategically placed to identify the amount and extent of these unwanted vibrations, and to validate the mathematical models used to predict the loads and dynamic response. Due to cost, installation, and data management issues, only a limited number of sensors will be available for placement. This work evaluates and compares four representative sensor placement algorithms for modal identification. Most of the sensor placement work to date has employed only numerical simulations for comparison. This work uses experimental data from a fully-instrumented truss structure which was one of a series of structures designed for research in dynamic scale model ground testing of large space structures at NASA Langley Research Center. Results from this comparison show that for this cantilevered structure, the algorithm based on Guyan reduction is rated slightly better than that based on Effective Independence.

Glassburn, Robin S.↗

LINFLUX-AE: A Turbomachinery Aeroelastic Code Based on a 3-D Linearized Euler Solver

This report describes the development and validation of LINFLUX-AE, a turbomachinery aeroelastic code based on the linearized unsteady 3-D Euler solver, LINFLUX. A helical fan with flat plate geometry is selected as the test case for numerical validation. The steady solution required by LINFLUX is obtained from the nonlinear Euler/Navier Stokes solver TURBO-AE. The report briefly describes the salient features of LINFLUX and the details of the aeroelastic extension. The aeroelastic formulation is based on a modal approach. An eigenvalue formulation is used for flutter analysis. The unsteady aerodynamic forces required for flutter are obtained by running LINFLUX for each mode, interblade phase angle and frequency of interest. The unsteady aerodynamic forces for forced response analysis are obtained from LINFLUX for the prescribed excitation, interblade phase angle, and frequency. The forced response amplitude is calculated from the modal summation of the generalized displacements. The unsteady pressures, work done per cycle, eigenvalues and forced response amplitudes obtained from LINFLUX are compared with those obtained from LINSUB, TURBO-AE, ASTROP2, and ANSYS.

Reddy, T. S. R.↗

Analytical and experimental studies of an optimum multisegment phased liner noise suppression concept

Results are presented from detailed analytical studies made to define methods for obtaining improved multisegment lining performance by taking advantage of relative placement of each lining segment. Properly phased liner segments reflect and spatially redistribute the incident acoustic energy and thus provide additional attenuation. A mathematical model was developed for rectangular ducts with uniform mean flow. Segmented acoustic fields were represented by duct eigenfunction expansions, and mode-matching was used to ensure continuity of the total field. Parametric studies were performed to identify attenuation mechanisms and define preliminary liner configurations. An optimization procedure was used to determine optimum liner impedance values for a given total lining length, Mach number, and incident modal distribution. Optimal segmented liners are presented and it is shown that, provided the sound source is well-defined and flow environment is known, conventional infinite duct optimum attenuation rates can be improved. To confirm these results, an experimental program was conducted in a laboratory test facility. The measured data are presented in the form of analytical-experimental correlations. Excellent agreement between theory and experiment verifies and substantiates the analytical prediction techniques. The results indicate that phased liners may be of immediate benefit in the development of improved aircraft exhaust duct noise suppressors.

Sawdy, D. T.↗

Blade loss transient dynamics analysis, volume 2. Task 2: Theoretical and analytical development. Task 3: Experimental verification

The component element method was used to develop a transient dynamic analysis computer program which is essentially based on modal synthesis combined with a central, finite difference, numerical integration scheme. The methodology leads to a modular or building-block technique that is amenable to computer programming. To verify the analytical method, turbine engine transient response analysis (TETRA), was applied to two blade-out test vehicles that had been previously instrumented and tested. Comparison of the time dependent test data with those predicted by TETRA led to recommendations for refinement or extension of the analytical method to improve its accuracy and overcome its shortcomings. The development of working equations, their discretization, numerical solution scheme, the modular concept of engine modelling, the program logical structure and some illustrated results are discussed. The blade-loss test vehicles (rig full engine), the type of measured data, and the engine structural model are described.

Gallardo, V. C.↗

In-plane inertial coupling in tuned and severely mistuned bladed disks

A model has been developed and verified for blade-disk-shaft coupling in rotors due to the in-plane rigid body modes of the disk. An analytic model has been developed which couples the in-plane rigid body modes of the disk on an elastic shaft with the blade bending modes. Bench resonance test were carried out on the M.I.T. Compressor Rotor, typical of research rotors with flexible blades and a thick rigid disk. When the rotor was carefully tuned, the structural coupling of the blades by the disks was confined to zero and one nodal diameter modes, whose modal frequencies were greater than the blade cantilever frequency. In the case of the tuned rotor, and in two cases where severe mistuning was intentionally introduced, agreement between the predicted and observed natural frequencies is excellent. The analytic model was then extended to include the effects of constant angular rotation of the disk.

Crawley, E. F.↗

Simulated rotor test apparatus dynamic characteristics in the 80- by 120-foot wind tunnel

A shake test was conducted in the 80 by 120 foot Wind Tunnel at NASA Ames Research Center, using a load frame and dummy weights to simulate the weight of the NASA Rotor Test Apparatus. The simulated hub was excited with broadband random excitation, and accelerometer responses were measured at various locations. The transfer functions (acceleration per unit excitation force as a function of frequency) for each of the accelerometer responses were computed, and the data were analyzed using modal analysis to estimate the model parameters.

Hoque, M. S.↗

The middeck 0-gravity dynamics experiment

The Middeck 0-Gravity Dynamics Experiment (MODE), flown onboard the Shuttle STS-48 Mission, consists of three major elements: the Experiment Support Module, a dynamics test bed providing computer experiment control, analog signal conditioning, power conditioning, an operator interface consisting of a keypad and display, experiment electrical and thermal control, and archival data storage: the Fluid Test Article assembly, used to investigate the dynamics of fluid-structure interaction in 0-gravity; and the Structural Test Article for investigating the open-loop dynamics of structures in 0-gravity. Deployable, erectable, and rotary modules were assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. Change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, and ambient gravity. An experimental study of the lateral slosh behavior of contained fluids is also presented. A comparison of the measured earth and space results identifies and highlights the effects of gravity on the linear and nonlinear slosh behavior of these fluids.

Crawley, Edward F.↗

Simulation and testing of digital control on a flexible beam

Large space structures are expected to have control problems due to low stiffness and damping, and control laws for these structures must deal with shape and configuration control as well as attitude and orbit maintenance. In general, these control tasks must be accomplished without adversely interacting with the lightly damped and low frequency vibration modes of the structure. Modal control schemes have been proposed to deal with these problems. A discrete time parameter adaptive control scheme which uses modal control has been proposed by Montgomery and Johnson (1978). In the present investigation the method considered by Montgomery and Johnson is applied to a homogeneous free-free beam in both numerical simulation and laboratory experimentation. Mathematical modeling of the beam is treated in a manner expedient for digital simulation and control implementation.

Williams, J. P.↗

Turbulence excited frequency domain damping measurement and truncation effects

Existing frequency domain modal frequency and damping analysis methods are discussed. The effects of truncation in the Laplace and Fourier transform data analysis methods are described. Methods for eliminating truncation errors from measured damping are presented. Implications of truncation effects in fast Fourier transform analysis are discussed. Limited comparison with test data is presented.

Soovere, J.↗

Performance characteristics of high-conductivity channel electron multipliers

The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

Timothy, J. G.↗