Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems

A technique was created to measure the pupil alignment of instruments in situ by measuring calibrated pupil alignment references (PARs) in instruments. The PAR can also be measured using an alignment telescope or an imaging system. PAR allows the verification of the science instrument (SI) pupil alignment at the integrated science instrument module (ISIM) level of assembly at ambient and cryogenic operating temperature. This will allow verification of the ISIM+SI alignment, and provide feedback to realign the SI if necessary.

Hagopian, John G.↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized, preprocessed by a small onboard computer, and then sent wirelessly to a desktop computer, where the collected data are analyzed and displayed. In addition to the raw data on temperature, pressure, flow, and mole fractions of oxygen and carbon dioxide, the display can include volumetric oxygen consumption, volumetric carbon dioxide production, respiratory equivalent ratio, and volumetric flow rate of exhaled gas.

Dietrich, Daniel L.↗

A Comparison of Aerosol Optical Property Measurements Made During the DOE Aerosol Intensive Operating Period and Their Effects on Regional Climate

The amount of radiant energy an aerosol absorbs has profound effects on climate and air quality. It is ironic that aerosol absorption coefficient is one of the most difficult to measure aerosol properties. One of the main purposes of the DOE Aerosol Intensive Operating Period (IOP) flown in May, 2003 was to assess our ability to measure absorption coefficient in situ. This paper compares measurements of aerosol optical properties made during the IOP. Measurements of aerosol absorption coefficient were made by Particle Soot Absorption Photometer (PSAP) aboard the CIRPAS Twin-Otter (U. Washington) and on the DOE Cessna 172 (NOAA-C,MDL). Aerosol absorption coefficient was also measured by a photoacoustic instrument (DRI) that was operated on an aircraft for the first time during the IOP. A new cavity ring-down (CRD) instrument, called Cadenza (NASA-AkC), measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. Absorption coefficient is obtained from the difference of measured extinction and scattering within the instrument. Measurements of absorption coefficient from all of these instruments during appropriate periods are compared. During the IOP, several significant aerosol layers were sampled aloft. These layers are identified in the remote (AATS-14) as well as in situ measurements. Extinction profiles measured by Cadenza are compared to those derived from the Ames Airborne Tracking Sunphotometer (AATS-14, NASA-ARC). The regional radiative impact of these layers is assessed by using the measured aerosol optical properties in a radiative transfer model.

Strawa, Anthony W.↗

Instrumentation for radio astronomy measurements aboard the IMP-I spacecraft

The design considerations and performance parameters of a satellite-borne instrumentation system are discussed. The system is designed to make radio astronomy measurements at eight discrete frequencies from 50 kHz to 3.53 MHz. These measurements are to detect solar and Jovian radio frequency bursts and to determine the average cosmic background radiation level down to 50 kHz. Procedures used for preflight and inflight calibration of the radiometer and the ground support equipment used for preflight testing are described.

Haddock, F. T.↗

Very long baseline interferometry /VLBI/ applications to secular geodynamics and earth strain measurement

An instrumental technique from radio astronomy known as very long baseline interferometry (VLBI) offers significant promise for the solution of the problem of accurate long-distance, three-dimensional surveying and determination of whole earth geodynamical phenomena. The methods of VLBI make it possible for receiving stations to be independently operated at arbitrary separations using extragalactic radio sources as their frame of time-invariant angular reference. Feasibility demonstrations at S-band (13 cm) wavelengths have been performed, and accuracies of a few centimeters for three-dimensional surveying over a short distance (16 km) have been demonstrated. VLBI operation on longer baselines (8400 km) has been performed between Goldstone, California, and Madrid, Spain, in order to develop the capability for determination of universal time variations, in addition to the measurements of this intercontinental baseline. Systems analysis indicates that necessary calibrations can be developed so as to make possible the implementation of a transportable radio interferometer station concept.

Macdoran, P. F.↗

Results from the 1995 Stratospheric Ozone Profile Intercomparison at Mauna Loa (MLO3)

In August 1995 multiple instruments that measure the stratospheric ozone vertical distribution were intercompared at the Mauna Loa Observatory, Hawaii, under the auspices of the Network for the Detection of Stratospheric Change. The instruments included two UV lidar systems, one from JPL and the other from Goddard Space Flight Center, ECC balloon-sondes, a ground-based microwave instrument, Umkehr measurements, and a new ground-based FTIR instrument. The MLS instrument on the UARS satellite provided correlative profiles of ozone, and there was one close overpass of the SAGE II instrument. The results show that much better consistency among instruments is being achieved than even a few years ago, usually to within the instrument uncertainties. The different measurement techniques in this comparison agree to within +/-10% at almost all altitudes, and in the 20 km to 45 km region most agreed within +/-5%. The results show that the current generation of lidars are capable of accurate measurement of the ozone profile to a maximum altitude of 50 km. SAGE agreed well with both lidar and balloon-sonde down to at least 17 km. The ground-based microwave measurement agreed with other measurements from 22 km to above 50 km. One minor source of disagreement continues to be the pressure-altitude conversion needed to compare a measurement of ozone density versus altitude with a measurement of ozone mixing ratio versus pressure.

McPeters, R. D.↗

Comprehensive analysis of gratings for ultraviolet space instrumentation

Comprehensive measurements in the vacuum UV range of 1200-3000 A of efficiency, polarization, and scattering of classically ruled and photoresist gratings are reported. The results show that the art of ruling gratings for vacuum UV use has reached a high level of sophistication and that careful analysis of grating properties can lead to useful improvement of the ruling art.

Mount, G. H.↗

Crosstalk in solar polarization measurements

The instrumental crosstalk associated with the Marshall Space Flight Center Vector Magnetograph and the solar crosstalk created by the magnetic field are described and their impact on the reconstruction of the solar vector magnetic field is analyzed. It is pointed out that identifying and correcting the crosstalk is important in the development of realistic models describing the solar atmosphere. Solar crosstalk is spatially dependent on the structure of the magnetic field while instrumental crosstalk is dependent on the position of the analyzer.

West, E. A.↗

An Instrument for Real-Time Measurement of Solid Rocket Motor Insulation Erosion

An instrument (eroding potentionmeter) has been designed to measure real-time case wall and inhibitor insulation char depth within a rocket motor during firing. Thus measurement can be close to the real-time recession of the insulation surface. The eroding potentionmeter consists of two small (3 mils 9in diameter) twisted resistive wires that are polyimide insulated. The wire pair form an electrical circuit and will recede with the erosion of the rocket motor internal insulation. A constant current applied along the wires will detect the resistance change via a voltage drop across the wires as the wire pair recedes with the decomposition fo the insulation. The eroding potentionmeter, as presently designed, can be an effective tool for real time measurement of internal insulation recession of a solid rocket motor. This tool will provide a way to accurately measure inhibitor performance or to measure flight effects of insulation erosion on a flight test. The eroding potentiometer has been verified on a plasma torch test and two static tests of a small solid rocket motor. There are some irregularities in the measured date, but the data remains useful in determining the real-time performance of internal insulation during a motor firing.

McWhorter, B. B.↗

Constructing Gloved wings for aerodynamic studies

Recently, two aircraft from the Dryden Flight Research Facility were used in the general study of natural laminar flow (NLF). The first, an F-14A aircraft on short-term loan from the Navy, was used to investigate transonic natural laminar flow. The second, an F-15A aircraft on long-term loan from the Air Force, was used to examine supersonic NLF. These tests were follow-on experiments to the NASA F-111 NLF experiment conducted in 1979. Both wings of the F-14A were gloved, in a two-phased experiment, with full-span(upper surface only) airfoil shapes constructed primarily of fiberglass, foam, and resin. A small section of the F-15A right wing was gloved in a similar manner. Each glove incorporated provisions for instrumentation to measure surface pressure distributions. The F-14A gloves also had provisions for instrumentation to measure boundary layer profiles, acoustic environments, and surface pitot pressures. Discussions of the techniques used to construct the gloves and to incorporate the required instrumentation are presented.

Bohn-Meyer, Marta R.↗

Experimental studies on the tripping behavior of narrow T-stiffened flat plates subjected to hydrostatic pressure and underwater shock

An experimental investigation was conducted to determine the static and dynamic responses of a specific stiffened flat plate design. The air-backed rectangular flat plates of 6061-T6 aluminum with an externally machined longitudinal narrow-flanged T-stiffener and clamped boundary conditions were subjected to static loading by water hydropump pressure and shock loading from an eight pound TNT charge detonated underwater. The dynamic test plate was instrumented to measure transient strains and free field pressure. The static test plate was instrumented to measure transient strains, plate deflection, and pressure. Emphasis was placed upon forcing static and dynamic stiffener tripping, obtaining relevant strain and pressure data, and studying the associated plate-stiffener behavior.

Budweg, H. L.↗

An instrumented fastener for shear force measurements in joints

A preliminary investigation has been conducted on instrumented fasteners for use as sensors to measure the shear loads transmitted by individual fasteners installed in double-splice joints. Calibration and load verification tests were conducted for instrumented fasteners installed at three fastener torque levels. Results from calibration tests show that the shear strains obtained from the instrumented fasteners vary linearly with the applied load and that the instrumented fasteners can be effectively used to measure shear loads transmitted by individual fasteners installed in double-splice joints. Tests were also conducted with three instumented fasteners installed in a typical double-splice joint. The test results showed that the load distribution between individual fasteners is dependent on the location of the fastener in the joint and the fastener torque level.

Sawyer, J. W.↗

AIRS Infrared Polarization Sensitivity and In-Flight Observations

The Atmospheric Infrared Sounder (AIRS) is a space-based instrument that measures the upwelling atmospheric spectrum in the infrared. AIRS is one of several instruments on the EOS-Aqua spacecraft launched on May 4, 2002: Typically, instrument polarization is not a concern in the infrared because the scene is usually not significantly polarized. A small amount of polarization is expected over ocean, which can be seen in the AIRS 3.7 (micro)m window channels. The polarization is seen as a signal difference between two channels with the same center frequency but different polarizations. The observations are compared to a model that relies on measurements of instrument polarization made pre-flight. A first look at a comparison of the observations of sea surface polarization to expectations is presented.

infrared↗

Continuous Measurement Of Mass Density Of Yarn

Prototype instrument provides measurement data from which one computes mass density of strand of yarn. Includes fixtures placing known length of yarn under known tension across fixed and movable support. Transverse vibrations induced in yarn by moving movable support up and down. Source of light illuminates photodetector at midlength of yarn, and photodetector senses repeated shadowing caused by vibration of yarn through light, thereby measuring vibrations. Also used for continuous real-time monitoring of such yarn-manufacturing processes as coating or impregnation.

Hinkley, Jeffrey A.↗