Experimental measurements of interfacial rheology using several techniques.
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
No abstract prepared.
Much effort has been put into determining methods to make accurate thickness measurements, especially at elevated temperatures. An accuracy of +/- 0.001 inches is typically noted for commercial ultrasonic thickness gauges and ultrasonic thickness techniques. Codes and standards put limitations on many inspection factors including equipment, calibration tolerance and temperature variations. These factors are important and should be controlled, but unfortunately do not guarantee accurate and repeatable measurements in the field. Most technicians long for a single technique that is best for every situation, unfortunately, there are no 'silver bullets' when it comes to nondestructive testing. This paper will describe and discuss some of the major contributors to measurement error as well as some advantages and limitations of multiple echo techniques and why multiple echo techniques should be more widely utilized for ultrasonic thickness measurements.
Properties of fluids confined in pore systems are needed for modeling fluid flow, fluid-rock interactions, and changes in reservoir porosity. The properties of CO2-rich fluids are particularly relevant to geothermal heat mining using carbon dioxide instead of water. While manometric, volumetric, and gravimetric techniques have been used successfully to investigate adsorption of low-density subcritical vapors, the results have not been satisfactory at higher, liquid-like densities of supercritical fluids. Even if the requirements for high experimental accuracy in the neighborhood of the critical region were met, these methods are fundamentally unable to deliver the total adsorption capacity, since the properties (e.g. density) of the adsorbed phase are in general not known. In this work we utilize vibrating tube densimetry for the first time to measure the total amount of fluid contained within a mesoporous solid. The method is first demonstrated using propane at subcritical and supercritical temperatures between 35 C and 97 C confined in silica aerogel (density 0.2 g cm-3, porosity 90%) that was synthesized inside Hastelloy U-tubes. Sorption and desorption of carbon dioxide on the same solid was measured at 35 C at pressures to 120 bar (density to 0.767 g cm-3). The results show total adsorption increasing monotonically with increasing pressure, unlike excess adsorption isotherms which show a maximum close to the critical density.
The rheology at gas-liquid interfaces strongly influences the stability and dynamics of foams and emulsions. Several experimental techniques are employed to characterize the rheology at liquid-gas interfaces with an emphasis on the non-Newtonian behavior of surfactant-laden interfaces. The focus is to relate the interfacial rheology to the foamability and foam stability of various aqueous systems. An interfacial stress rheometer (ISR) is used to measure the steady and dynamic rheology by applying an external magnetic field to actuate a magnetic needle suspended at the interface. Results are compared with those from a double wall ring attachment to a rotational rheometer (TA Instruments AR-G2). Micro-interfacial rheology (MIR) is also performed using optical tweezers to manipulate suspended microparticle probes at the interface to investigate the steady and dynamic rheology. Additionally, a surface dilatational rheometer (SDR) is used to periodically oscillate the volume of a pendant drop or buoyant bubble. Applying the Young-Laplace equation to the drop shape, a time-dependent surface tension can be calculated and used to determine the effective dilatational viscosity of an interface. Using the ISR, double wall ring, SDR, and MIR, a wide range of sensitivity in surface forces (fN to nN) can be explored as each experimental method has different sensitivities. Measurements will be compared to foam stability.
No abstract prepared.
No abstract prepared.
The booster synchrotron for NSLS-II will include a 7-cell PETRA cavity, which was manufactured for the PETRA-II project at DESY. The cavity fundamental frequency operates at 500 MHz. In order to verify the impedances of the fundamental and higher-order modes (HOM), which were calculated by computer code, we measured the magnitude of the electromagnetic field of the fundamental acceleration mode and HOM using the bead-pull method. To keep the cavity body temperature constant, we used a chiller system to supply cooling water at 20 degrees C. The bead-pull measurement was automated with a computer. We encountered some issues during the measurement process due to the difficulty in measuring the electromagnetic field magnitude in a multi-cell cavity. We describe the method and apparatus for the field measurement, and the obtained results.
A technique adapted from the guarded-comparative-longitudinal heat flow method was selected for the measurement of the thermal conductivity of a nuclear fuel compact over a temperature range characteristic of its usage. This technique fulfills the requirement for non-destructive measurement of the composite compact. Although numerous measurement systems have been created based on the guarded comparative method, comprehensive systematic (bias) and measurement (precision) uncertainty associated with this technique have not been fully analyzed. Using finite element modeling, this paper presents the study of two types of error sources in the thermal conductivity measurement process: sample and system geometries and working conditions. The results and conclusions provide valuable reference for designing and operating an experimental measurement system using this technique.
Variance estimates that are used in the analysis of radiation measurements must represent all of the measurement and computational uncertainties in order to obtain accurate parameter and uncertainty estimates. This report describes an approach for estimating components of the variance associated with both statistical and computational uncertainties. A multi-sensor fusion method is presented that renders parameter estimates for one-dimensional source models based on input from different types of sensors. Data obtained with multiple types of sensors improve the accuracy of the parameter estimates, and inconsistencies in measurements are also reflected in the uncertainties for the estimated parameter. Specific analysis examples are presented that incorporate a single gross neutron measurement with gamma-ray spectra that contain thousands of channels. The parameter estimation approach is tolerant of computational errors associated with detector response functions and source model approximations.
Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.
Presentation on real-time imaging of plant cell wall structure at nanometer scale. Objectives are to develop tools to measure biomass at the nanometer scale; elucidate the molecular bases of biomass deconstruction; and identify factors that affect the conversion efficiency of biomass-to-biofuels.
Measurement and analysis of residence time distribution (RTD) data is the focus of this study where data collection methods were developed specifically for the pretreatment reactor environment. Augmented physical sampling and automated online detection methods were developed and applied. Both the measurement techniques themselves and the produced RTD data are presented and discussed.
Oxygen concentration in liquid sodium is a critical measurement in assessing the potential for corrosion damage in sodium-cooled fast reactors (SFRs). There has been little recent work on sodium reactors and oxygen detection. Thus, the technical expertise dealing with oxygen measurements within sodium is no longer readily available in the U.S. Two methods of oxygen detection that have been investigated are the plugging meter and the galvanic cell. One of the overall goals of the Univ. of Wisconsin's sodium research program is to develop an affordable, reliable galvanic cell oxygen sensor. Accordingly, attention must first be dedicated to a well-known standard known as a plugging meter. Therefore, a sodium loop has been constructed on campus in effort to develop the plugging meter technique and gain experience working with liquid metal. The loop contains both a galvanic cell test section and a plugging meter test section. Consistent plugging results have been achieved below 20 [wppm], and a detailed process for achieving effective plugging has been developed. This paper will focus both on an accurate methodology to obtain oxygen concentrations from a plugging meter, and on how to easily control the oxygen concentration of sodium in a test loop. Details of the design, materials, manufacturing, and operation will be presented. Data interpretation will also be discussed, since a modern discussion of plugging data interpretation does not currently exist. (authors)
The Region 3 Aerial Measurement System Flight Planning Tool is used by the National Nuclear Security Agency (NNSA), United States Department of Energy, Radiological Assistance Program, Region 3, to respond to emergency radiological situations. The tool automates the flight planning package process while decreasing Aerial Measuring System response times and decreases the potential for human error. Deployment of the Region Three Aerial Measurement System Flight Planning Tool has resulted in an immediate improvement to the flight planning process in that time required for mission planning has been reduced from 1.5 hours to 15 minutes. Anecdotally, the RAP team reports that the rate of usable data acquired during surveys has improved from 40-60 percent to over 90 percent since they began using the tool. Though the primary product of the flight planning tool is a pdf format document for use by the aircraft flight crew, the RAP team has begun carrying their laptop computer on the aircraft during missions. By connecting a Global Positioning System (GPS) device to the laptop and using ESRI ArcMap's GPS tool bar to overlay the aircraft position directly on the flight plan in real time, the RAP team can evaluate and correct the aircraft position as the mission is executed. (authors)
The critical configuration of the small, compact critical assembly (SCCA) experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) in 1962-1965[1,2] have been evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and were determined to be acceptable benchmark experiments and are included in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook)[3]. The initial intent of these experiments was to support the design of the Medium Power Reactor Experiment (MPRE) program, whose purpose was to study 'power plants for the production of electrical power in space vehicles'.[4] The third configuration in this series of experiments was a beryllium-reflected mockup of a stainless-steel-clad, highly enriched uranium (HEU)-O{sub 2} fuel, potassium-cooled, space power reactor. Reactivity measurements, cadmium ratio spectral measurements, and fission rate measurements were measured through the core and top reflector. Fuel effect worth measurements and neutron moderating and absorbing material worths were also measured in the assembly fuel region. The cadmium ratios, fission rate, and worth measurements were evaluated for the International Reactor Physics Experiment Evaluation Project (IRPhEP) and are published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook)[5]. More recently, two additional critical configurations have been evaluated and added to the existing evaluation report in the ICSBEP Handbook. The new critical configurations measure the effect of filling the core with potassium. The critical configuration consisted of 30.48 cm tall fuel tubes of 93.15 wt.% enriched uranium dioxide (UO{sub 2}) pellets. Each fuel tube had 26 pellets with a total mass of 295.8 g UO{sub 2} per tube. There were 253 tubes were arranged with 1.506-cm center-to-center, triangular spacing and surrounded on all side by a beryllium reflected. The reactivity of the system was measured with the core tank empty and filled with potassium. The system reactivity was increased from 13.4 c to 32 c. This change in system reactivity represents the worth of the potassium. Simple benchmark models for the empty and potassium filled cores have been derived and evaluated and found to be acceptable as benchmark experiments. The benchmark experiment eigenvalues are 1.0001 ± 0.0008 and 1.0011 ± 0.0009 for the empty and filled cores, respectively. When calculated with MCNP5 and ENDF/B-VII.0 the calculated eigenvalues are 0.98906 ± 0.00002 and 0.98883 ± 0.00002, respectively. These results are concerning due to the drop of the calculated system reactivity when potassium is added to the system rather than the expected increase in system reactivity. (authors)