Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mars Missions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The PH-D proposal - A manned mission to Phobos and Deimos

The rationale for a manned mission to the satellites of Mars is discussed. The view has been expressed that NASA must define a major program to follow the Shuttle and to utilize it. However, such a program could not be initiated and proceed without public support, and to obtain this support, public interest would have to be excited. It is shown that, of a number of possible targets for manned exploration in the solar system, Mars appears to be the only possible candidate. Attention is given to a comparison of three Mars missions, a Mars 1984 mission, a manned landing on Mars surface, a manned landing on Phobos and Deimos (Ph-D project), putting men in Mars orbit, the capabilities of the Ph-D mission, a description of the spacecraft, a Ph-D project operations plan, and aspects of timing, technology, and costs.

Singer, S. F.↗

NASA Mars 2020 Landed Mission Development

In January of 2014, NASA received fifty-eight proposals from U.S. and international teams for science and exploration technology investigations, for consideration for inclusion as part of NASA's next mobile landed mission to Mars. The results of the competitive procurement were released in late July of 2014: Seven payloads were selected for the investigations that would contribute to meeting the overall objectives of the mission. The extraordinary scientific and technology development interest in the Mars 2020 mission is a direct result of NASA's sustained and coordinated plan for the exploration of Mars, and ultimately, its search for life elsewhere in the universe. The Mars 2020 Mission will preserve the heritage and directly build upon NASA's Mars Science Laboratory Mission and Curiosity Rover to implement its mission. In this paper, early development history leading to its development announcement, as well as key development status and design features for its implementation, is summarized.

MSR↗

NASA Mars 2020 landed mission development

In January of 2014, NASA received fifty-eight proposals from U.S. and international teams for science and exploration technology investigations, for consideration for inclusion as part of NASA’s next mobile landed mission to Mars. The results of the competitive procurement were released in late July of 2014: Seven payloads were selected for the investigations that would contribute to meeting the overall objectives of the mission. The extraordinary scientific and technology development interest in the Mars 2020 mission is a direct result of NASA’s sustained and coordinated plan for the exploration of Mars, and ultimately, its search for life elsewhere in the universe. The Mars 2020 Mission will preserve the heritage and directly build upon NASA’s Mars Science Laboratory Mission and Curiosity Rover to implement its mission. In this paper, early development history leading to its development announcement, as well as key development status and design features for its implementation, is summarized.

Abilleira, Fernando↗

Investigations Using Laboratory Testbeds to Interpret Flight Instrument Datasets from Mars Robotic Missions

The Astromaterials Research and Exploration Science Directorate at the NASA Johnson Space Center (JSC) has laboratory instrumentation that mimic the capabilities of corresponding flight instruments to enable interpretation of datasets returned from Mars robotic missions. The lab instruments have been and continue to be applied to datasets for the Moessbauer Spectrometer (MB) on the Mars Exploration Rovers (MER), the Thermal & Evolved Gas Analyzer (TEGA) on the Mars Phoenix Scout, the CRISM instrument on the Mars Reconnaissance Orbiter Missions and will be applied to datasets for the Sample Analysis at Mars (SAM), Chemistry and Mineralogy (CheMin) and Chemistry & Camera (ChemCam) instruments onboard the Mars Science Laboratory (MSL). The laboratory instruments can analyze analog samples at costs that are substantially lower than engineering models of flight instruments, but their success to enable interpretation of flight data depends on how closely their capabilities mimic those of the flight instrument. The JSC lab MB instruments are equivalent to the MER instruments except without flight qualified components and no reference channel Co-57 source. Data from analog samples were critical for identification of Mg-Fe carbonate at Gusev crater. Fiber-optic VNIR spectrometers are used to obtain CRISM-like spectral data over the range 350-2500 nm, and data for Fephyllosilicates show irreversible behavior in the electronic transition region upon dessication. The MB and VNIR instruments can be operated within chambers where, for example, the absolute H2O concentration can be measured and controlled. Phoenix's TEGA consisted of a calorimeter coupled to a mass spectrometer (MS). The JSC laboratory testbed instrument consisted of a differential scanning calorimeter (DSC) coupled to a MS configured to operate under total pressure (12 mbar), heating rate (20 C/min), and purge gas composition (N2) analogous to the flight TEGA. TEGA detected CO2 release at both low (400-680 C) and high (725-820 C) temperature and an endothermic reaction in concert with the high temperature release. The high-temperature thermal decomposition is consistent with calcite, dolomite, or ankerite, (3-6 wt.%) or any combination of these phase based upon laboratory testbed experiments. Recent laboratory experiments suggest that the low temperature CO2 release was caused by a reaction between calcium carbonate and hydrated magnesium perchlorate; although, CO2 release by the oxidation of organic materials and Fe-/Mg-rich carbonates cannot be ruled out. MSL landed in Gale crater on August 5, 2012. Although numerous analog samples have been analyzed on the JSC laboratory testbeds, no SAM, CheMin, or ChemCam analyses have been acquired by MSL to date. The JSC SAM laboratory testbed consists of a thermal analyzer coupled with a MS configured to operate under total pressure (30 mbar), heating rate (35 C/min), and purge gas composition (He) analogous to the flight SAM. The CheMin and ChemCam laboratory testbeds were developed and built by inXitu, Inc. and Los Alamos National Laboratory, respectively, to acquire datasets relevant to the MSL CheMin and ChemCam flight instruments.

Ming, D. W.↗

The first Viking mission to Mars

The paper outlines the major goals and present achievements of the Viking 1 mission to Mars. The construction and instrumentation of the orbiter and lander are described. The criteria used to select the optimum landing site are discussed together with orbit adjustments and the landing process. Special attention is given to constraints on surface coverage and observation conditions.

Soffen, G. A.↗

Human Missions to Mars Orbit, Phobos, and Mars Surface Using 100-kWe-Class Solar Electric Propulsion

Solar electric propulsion (SEP) tugs in the 100-kWe range, may be utilized to preposition cargo in the Mars system to enable more affordable human missions to Phobos and to the surface of Mars. The SEP tug, a high heritage follow-on to the 50-kWe SEP spacecraft proposed for the Asteroid Redirect Robotic Mission (ARRM), would have the same structure, tankage, electric propulsion components, and avionics as the ARRM version, But with double the number of solar arrays, Hall thrusters, and power processor units (PPUs) and would be accommodated within the same launch envelope defined for ARRM. As a feasibility study, a 950-day human mission to Phobos using a conjunction class trajectory, such as the 2033 opportunity, was developed using two 100-kWe SEP vehicles to preposition a habitat at Phobos and propulsion stages in high Mars orbit (HMO). An architecture concept for a crewed Mars surface lander mission was also developed as a reference to build on the Phobos mission architecture, adding a lander element that could be delivered using chemical propulsion and aerocapture.

Price, Humphrey W.↗

The 1975 Viking mission to Mars

An overall description is presented of the Viking mission and systems as well as what may be learned from this mission. Pre-space-age knowledge about Mars is summarized together with information obtained by the Mariner probes. It is noted that the subject of life on Mars is a prominent theme of the Viking mission, and brief descriptions are given of the mission profile and landing sites. The thirteen scientific investigations to be conducted are outlined, including atmospheric-water mapping, surface thermal mapping, orbiter and lander imaging, radio experiments, measurements of the present physical and chemical state of the Martian atmosphere, and the three biochemical experiments. Relatively detailed descriptions are provided for the space vehicles, launch operations, mission profile, and management responsibilities.

Martin, J. S., Jr.↗

Nuclear-electric propulsion - Manned Mars propulsion options

Nuclear-electric propulsion can significantly reduce the launch mass for manned Mars missions. By using high-specific-impulse (lsp) electric propulsion systems with advanced nuclear reactors, the total mass-to-orbit for a series of manned Mars flight is reduced. Propulsion technologies required for the manned Mars mission are described. Multi-megawatt Ion and Magneto-Plasma-Dynamic (MPD) propulsion thrusters, Power-Processing Units and nuclear power source are needed. Xenon (Xe)-Ion and MPD thruster performance are detailed. Mission analyses for several Mars mission options are addressed. Both MPD and Ion propulsion were investigated. A four-megawatt propulsion system power level was assumed. Mass comparisons for all-chemical oxygen/hydrogen propulsion missions and combined chemical and nuclear-electric propulsion Mars fleets are included. With fleets of small nuclear-electric vehicles, short trip times to Mars are also enabled.

Palaszewski, Bryan↗

Physiological Health Challenges for Human Missions to Mars

During the next decades, manned space missions are expected to be aiming at the Lagrange points, near Earth asteroids, and Mars flyby and/or landing. The question is therefore: Are we ready to go? To answer this with a yes, we are currently using the International Space Station to develop an integrated human physiological countermeasure suite. The integrated countermeasure suite will most likely encounter: 1) Exercise devices for aerobic, dynamic and resistive exercise training; 2) sensory‐motor computer training programs and anti‐motion sickness medication for preparing EVAs and G‐transitions; 3) lower limb bracelets for preventing and/or treating the VIIP (vision impairment and intracranial pressure) syndrome; 4) nutritional components for maintenance of bone, muscle, the cardiovascular system and preventing oxidative stress and damage and immune deficiencies (e. g. omega‐3 fatty acids, PRO/K, anti‐oxidants and less salt and iron); 5) bisphosphonates for preventing bone degradation.; 6) lower body compression garment and oral salt and fluid loading for landing on a planetary surface to combat orthostatic intolerance; 7) laboratory analysis equipment for individualized monitoring of biomarkers in blood, urine and saliva for estimation of health status in; 8) advanced ultrasound techniques for monitoring bone and cardiovascular health; and 9) computer modeling programs for individual health status assessments of efficiency and subsequent adjustments of countermeasures. In particular for future missions into deep space, we are concerned with the synergistic effects of weightlessness, radiation, operational constraints and other spaceflight environmental factors. Therefore, increased collaboration between physiological, behavioral, radiation and space vehicle design disciplines are strongly warranted. Another venue we are exploring in NASA's Human Research Program is the usefulness of artificial gravity for mitigating the health risks of long duration weightlessness.

Norsk, Peter↗

Testing of Space Suit Materials for Mars

Human missions to Mars may require radical changes in our approach to EVA suit design. A major challenge is the balance of building a suit robust enough to complete 50 EVAs in the dirt under intense UV exposure without losing mechanical strength or compromising its mobility. We conducted ground testing on both current and new space suit materials to determine performance degradation after exposure to 2500 hours of Mars mission equivalent UV. This testing will help mature the material technologies and provide performance data that can be used by not only the space suit development teams but for all Mars inflatable and soft goods derived structures from airlocks to habitats.

Larson, Kristine↗

Reusable In-Space Transportation Architecture Options for Human Mars Expeditions

NASA has been investigating the use of Solar Electric Propulsion, Chemical Propulsion, and Nuclear Thermal Propulsion systems to deliver crew and cargo to Mars orbit in support of expeditions to the Martian surface. In order to evaluate the effect of the selection of in-space transportation options on a series of human Mars missions across multiple opportunities, campaign level analysis must be performed and the transportation options must be evaluated using the same set of ground rules and assumptions to provide equal comparison. In this study, a comparison of three in-space transportation options was shown from a campaign level perspective. Campaign level metrics such as total launch mass, launch vehicle launch rate, and total launch vehicle required are presented to show how the different transportation systems perform to field a series of Mars missions across multiple mission opportunities. Each transportation option was utilized to perform three crew roundtrip missions to Mars, with supporting cargo missions starting in 2029, the first crewed mission to Mars in 2035. The transportation options each have strengths and weaknesses from a campaign and strategic investment point of view, as evident by the comparison between the total launch mass and the total number of launch vehicles required. While the analysis shown in this study provides an initial comparison between the transportation options, significant challenges still exists for each options in terms of the detailed mission operations and the feasibility of all of the assumptions.

Chai, Patrick R.↗

A Mars rover mission concept

This paper discusses the design concept of the Mars Rover/Sample Return (MRSR) mission. Special consideration is given to the issues of the power source, the scale and performance of the mobility subsystem, the requirements of the sampling subsystem, and the degree of automation, as well as to the features and the orbit design of a Mars orbiting vehicle (MOV) supporting the landed operations. The details of the integrated aeroshell configuration, that includes the rover, the lander, and the MOV during the Mars orbit insertion phase are described, and the diagrams of the MRSR mission and its elements are presented.

Randolph, J. E.↗

Developing Ultra Reliable Life Support for the Moon and Mars

Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.

Jones, Harry W.↗