Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Novel method to control explosive shock sensitivity: Formulations, experiments and modeling

The microstructure of a heterogeneous high explosive (HE) affects its shock initiation sensitivity and detonation performance. Alteration of the void content and/or void structure (i.e., bulk heating or mechanical damage) therefore changes the shock initiation behavior. Controlling and predicting the change in shock sensitivity after an HE has undergone microstructural changes addresses an important and challenging goal for the design and understanding of novel energetic material formulations. In this study, we aimed to develop HE systems to precisely tune shock sensitivity by a thermal treatment prior to use. Specifically, we incorporated a small fraction (1 wt% or less) of thermally expandable microspheres (TEMs) during the formulation process of various plastic-bonded explosives (PBX). TEMs typically consist of a thermoplastic acrylonitrile shell (10-50 µm diameter), which encapsulates an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol% (irreversibly). Here, we present our progress on shock sensitivity comparisons of HE formulations doped with TEMs after heating and expansion. Experiments, using Composition C-4 thermally cycled to 120°C, showed an increase in shock sensitivity. Additionally, mesoscale modeling revealed that the TEM itself does not act as a hotspot, but instead has a secondary effect on the response of nearby voids. We conclude that TEMs indeed do provide a method to tune shock sensitivity. Further, our results emphasize the non-uniformity of shock waves at the mesoscale, and that upstream defects influence the reactivity of downstream defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel fabrication tools for dynamic compression targets with engineered voids using photolithography methods

Mesoscale imperfections, such as pores and voids, can strongly modify the properties and the mechanical response of materials under extreme conditions. Tracking the material response and microstructure evolution during void collapse is crucial for understanding its performance. In particular, imperfections in the ablator materials, such as voids, can limit the efficiency of the fusion reaction and ultimately hinder ignition. To characterize how voids influence the response of materials during dynamic loading and seed hydrodynamic instabilities, we, in this paper, have developed a tailored fabrication procedure for designer targets with voids at specific locations. Our procedure uses SU-8 as a proxy for the ablator materials and hollow silica microspheres as a proxy for voids and pores. By using photolithography to design the targets’ geometry, we demonstrate precise and highly reproducible placement of a single void within the sample, which is key for a detailed understanding of its behavior under shock compression. This fabrication technique will benefit high-repetition rate experiments at x-ray and laser facilities. Insight from shock compression experiments will provide benchmarks for the next generation of microphysics modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lamination of transparent conductive adhesives for tandem solar cell applications

A transparent conductive adhesive (TCA) interlayer for mechanically stacked multijunction solar cells provides adhesive strength and electrical connection between sub-cells when stacked. The fabrication of TCA sheets from an ethyl-vinyl acetate (EVA) matrix and silver coated compliant conductive microspheres, similar to industry-standard EVA encapsulant sheets, compatible with a standard lamination process was developed. Blade coating TCA sheets using 3D printed blades and testing of vertical conduction through the interlayer with a TCA conductivity jig allowed for reproducible measurements and low-cost fabrication. The supplemental information provides design files to enable other researchers to produce their own blades and testing jigs. We identified 0.5 mm as an optimal blade height for producing lab-scale TCA sheets and 120 °C at 3 psi for 10 min as the optimal vacuum lamination process to minimize resistance and possible damage to samples. For TCA sheets with coverages between 0.75% and 9%, the series resistance was approximately 0.2 O cm2 which should result in minimal losses for one-sun photovoltaic applications.

14 SOLAR ENERGY↗

Prototype tests of the electromagnetic particle injector-2 for fast time response disruption mitigation in tokamaks

Predicting and controlling disruptions is an important and urgent issue for ITER. Some disruptions with a short warning time may be unavoidable. For these cases, a fast time response disruption mitigation method is essential. Experimental tests on a prototype system of a novel, rapid time-response disruption mitigation system being developed for tokamak-based reactors and as a backup option for ITER, referred to as the electromagnetic particle injector (EPI), have been able to verify the primary advantages of the concept. These are its ability to meet short warning time scales of <10 ms while attaining the projected high velocities for deep radiative payload penetration in reactor-scale plasmas. The EPI relies on an electromagnetic propulsion system. A metallic sabot is accelerated electromagnetically to the required velocities (>1 km s -1 ) within 2 ms, at which point it releases a radiative payload consisting of a shell pellet or well-defined microspheres. Initial experimental tests from the prototype system show attainment of over 600 m s -1 in about 1 ms. Finally, essential aspects of payload separation from the sabot and sabot capture have also been demonstrated at 200 m s -1 , and the method can be extended to over 2 km s -1 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy transfer between localized emitters in photonic cavities from first principles

Radiative and nonradiative resonant couplings between defects are ubiquitous phenomena in photonic devices used in classical and quantum information technology applications. In this work, we present a first-principles approach to enable quantitative predictions of the energy transfer between defects in photonic cavities, beyond the dipole-dipole approximation and including the many-body nature of the electronic states. As an example, we discuss the energy transfer from a dipolelike emitter to an 𝐹 center in MgO in a spherical cavity. We show that the cavity can be used to controllably enhance or suppress specific spin-flip and spin-conserving transitions. Specifically, we predict that an ∼10–100 enhancement in the resonant energy transfer rate can be gained in the case of the 𝐹 center in MgO at ∼10 nm distances from a dipolar source, using rather moderate cavity with quality factor 𝑄 ∼ 400. We also show that a similar suppression in the transfer rate can be achieved by off-tuning the cavity resonance relative to the emitter transition energy. The framework presented here is general and readily applicable to a wide range of devices where localized emitters are embedded in microspheres, core-shell nanoparticles, and dielectric Mie resonators. Hence, our approach paves the way to predict how to control energy transfer in quantum memories and in ultrahigh-density optical memories, and in a variety of quantum information platforms.

First-principles calculations↗

Mode-selective thermal radiation from a microparticle

We experimentally demonstrate that thermal radiation from a micron-sized dielectric particle depends sensitively on its size and shape through the cavity quantum-electrodynamic effect. Our laser trapping technique levitated a high-temperature microsphere of Al{sub 2}O{sub 3} and enabled emission spectroscopy of the single particle. As the particle becomes smaller, a blackbodylike spectrum turns into a spectrum dominated by multiple peaks resonant with whispering gallery modes of the spherical resonator. The observed sharp frequency selectivity is applicable to spectral control of thermal radiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Trapping of High-Aspect-Ratio NaYF Hexagonal Prisms for kHz-MHz Gravitational Wave Detectors

Here, we present experimental results on optical trapping of Yb-doped β-NaYF subwavelength-thickness high-aspect-ratio hexagonal prisms with a micron-scale radius. The prisms are trapped in vacuum using an optical standing wave, with the normal vector to their face oriented along the beam propagation direction, yielding much higher trapping frequencies than those typically achieved with microspheres of similar mass. This platelike geometry simultaneously enables trapping with low photon-recoil-heating, high mass, and high trap frequency, potentially leading to advances in high frequency gravitational wave searches in the Levitated Sensor Detector, currently under construction. The material used here has previously been shown to exhibit internal cooling via laser refrigeration when optically trapped and illuminated with light of suitable wavelength. Employing such laser refrigeration methods in the context of our work may enable higher trapping intensity and thus higher trap frequencies for gravitational wave searches approaching the several hundred kilohertz range.

47 OTHER INSTRUMENTATION↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability of rare‐earth‐doped spherical yttria‐stabilized zirconia synthesized by ultrasonic spray pyrolysis

Abstract Phase stability is one of the crucial requirements for any material that can be used at elevated temperature applications such as thermal barrier coating ( TBC ). The most traditional TBC material, partially stabilized zirconia, limits the operating temperature due to its phase transformation. Conversely, the low thermal conductivity of fully stabilized zirconia ( YSZ ) may enable effective reduction in the surface temperature on the coated component, while avoiding deleterious phase transitions, although still being subjected to sintering and grain growth. It has been reported that addition of rare‐earths as dopants to YSZ can significantly increase resistance to grain growth at high temperature. Keeping this under consideration, this work investigates the role of rare‐earths (lanthanum and gadolinium) in increasing thermal stability of YSZ microspheres, the building blocks for high‐temperature photonics for reflective TBC . The spheres were produced by ultrasonic spray pyrolysis, and the doping led to significant improvement of stability by significant inhibition of grain growth. While the individual dopants showed significant growth and sintering inhibition up to 900°C, co‐doping with 4% (in mol) of each (Gd and La) led to coarsening resistance up to 1000°C for 3 hours, when particles retained reasonable spherical features with nanometric crystallite sizes.

Nafsin, Nazia↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

SU-E-I-90: Characterizing Small Animal Lung Properties Using Speckle Observed with An In-Line X-Ray Phase Contrast Benchtop System

Purpose: We demonstrate a novel X-ray phase-contrast (XPC) method for lung imaging representing a paradigm shift in the way small animal functional imaging is performed. In our method, information regarding airway microstructure that is encoded within speckle texture of a single XPC radiograph is decoded to produce 2D parametric images that will spatially resolve changes in lung properties such as microstructure sizes and air volumes. Such information cannot be derived from conventional lung radiography or any other 2D imaging modality. By computing these images at different points within a breathing cycle, dynamic functional imaging will be readily achieved without the need for tomography. Methods: XPC mouse lung radiographs acquired in situ with an in-line X-ray phase contrast benchtop system. The lung air volume is varied and controlled with a small animal ventilator. XPC radiographs will be acquired for various lung air volume levels representing different phases of the respiratory cycle. Similar data will be acquired of microsphere-based lung phantoms containing hollow glass spheres with known distributions of diameters. Image texture analysis is applied to the data to investigate relationships between texture characteristics and airspace/microsphere physical properties. Results: Correlations between Fourier-based texture descriptors (FBTDs) and regional lung air volume indicate that the texture features in 2D radiographs reveal information on 3D properties of the lungs. For example, we find for a 350 × 350 πm2 lung ROI a linear relationship between injected air volume and FBTD value with slope and intercept of 8.9×10{sup 5} and 7.5, respectively. Conclusion: We demonstrate specific image texture measures related to lung speckle features are correlated with physical characteristics of refracting elements (i.e. lung air spaces). Furthermore, we present results indicating the feasibility of implementing the technique with a simple imaging system design, short exposures, and low dose which provides potential for widespread use in laboratory settings for in vivo studies. This research was supported in part by NSF Award CBET1263988.

60 APPLIED LIFE SCIENCES↗

SU-E-T-663: Radiation Properties of a Water-Equivalent Material Formulated Using the Stoichiometric Analysis Method in Heavy Charged Particle Therapy

Purpose: A material has been designed to be employed as water-equivalent in particle therapy using a previously established stoichiometric analysis method (SAM). After manufacturing, experimental verification of the material’s water-equivalent path length (WEPL) and analysis of its total inelastic nuclear interaction cross sections for proton beams were performed. Methods: Using the SAM, we optimized the material composed of three base materials, i.e., polyurethane, calcium carbonate and microspheres. From the elemental composition of the compound, electron density, linear attenuation coefficients, particle stopping powers and inelastic nuclear cross sections for protons using data from ICRU 63 were calculated. The calculations were then compared to Hounsfield units (HUs) measured with 350 mAs at 80, 100, 120 and 140 kV and the WEPLs measured with three different ions: proton (106.8 MeV/u), helium (107.93 MeV/u) and carbon (200.3 MeV/u). Results: The material’s measured HUs (0.7±3.0 to 2.6±6.2 HU) as well as its calculated relative electron density (1.0001) are in close agreement with water as reference. The WEPLs measured on a 20.00 mm thick target were 20.16±0.12, 20.29±0.12 and 20.38±0.12 mmH2O for proton, helium and carbon ions, respectively. Within measurement uncertainties, these values verified the calculated WEPLs of 20.28 mmH2O (proton), 20.28 mmH2O (helium) and 20.26 mmH2O (carbon). Moreover, the calculated proton inelastic cross sections of the material differed only by 0.89% (100 MeV/u) and 0.01% (200 MeV/u) when compared to water. Conclusion: The SAM is capable of optimizing material with defined properties, e.g., HU, electron density, WEPL and inelastic nuclear interaction cross section for particle therapy. Such material will have a wide range of applications amongst others absolute dosimetry. This work was supported by grant ZIM KF2137107AK4 from the German Federal Ministry for Economic Affairs and Energy.

07 ISOTOPE AND RADIATION SOURCES↗

MO-AB-201-01: Regulatory Compliance and Safety with New Radiotherapies: Spheres and Ra-223

The role of the Radiation Safety Officer at a medical facility can be complicated. The complexity of the position is based on the breadth of services provided at the institution and the nature of the radioactive materials license. Medical practices are constantly changing and the use of ionizing radiation continues to rise in this area. Some of the newer medical applications involving radiation have unique regulatory and safety issues that must be addressed. Oversight of the uses of radiation start at the local level (radiation safety officer, radiation safety committee) and are heavily impacted by outside agencies (i.e. Nuclear Regulatory Commission, State Radiologic Health, The Joint Commission (TJC), etc). This session will provide both an overview of regulatory oversight and essential compliance practices as well as practical ways to assess and introduce some of the new applications utilizing radioactive materials into your medical facility. Learning Objectives: Regulatory Compliance and Safety with New Radiotherapies: Spheres and Ra-223 (Lance Phillips) Understand the radioactive materials license amendment process to add new radiotherapies (i.e., SIR-Spheres, Therasphere, Xofigo). Understand the AU approval process for microspheres and Xofigo. Examine the training and handling requirements for new procedures. Understand the process involved with protocol development, SOP in order to define roles and responsibilities. The RSO and The RSC: Challenges and Opportunities (Colin Dimock) Understand how to form an effective Committee. Examine what the Committee does for the Program and the RSO. Understand the importance of Committee engagement. Discuss the balance of the complimentary roles of the RSO and the Committee. The Alphabet Soup of Regulatory Compliance: Being Prepared for Inspections (Linda Kroger) Recognize the various regulatory bodies and organizations with oversight or impact in Nuclear Medicine, Radiology and Radiation Oncology. Examine 10CFR35 requirements as they relate to the everyday practice of Nuclear Medicine and Radiation Oncology. Understand the nature of available guidance documents (e.g., NUREG 1556). Examine the commonalities between TJC and CMS preparedness.

60 APPLIED LIFE SCIENCES↗

SU-C-204-07: Radiation Therapy as a Potential Treatment for Obesity: Initial Data from a Preclinical Investigation

Purpose: To evaluate the feasibility of Yttrium-90 (90Y) radionuclide therapy as a potential treatment for obesity in a porcine model. As the only appetite-stimulating hormone, localized targeting of ghrelin-producing X/A cells in the fundus of the stomach using 90Y may reduce serum ghrelin levels and decrease hunger. Methods: Under approval of the University of Tennessee IACUC, 8 young female pigs aged 12–13 weeks and weighing 21.8–28.1 Kg were included in this study. Six animals underwent transfemoral angiography as part of a two-day procedure involving: (1) infusion of 99mTc-MAA, followed by nuclear scintigraphy and contrast-enhanced CT for treatment-planning and (2) administration of resin 90Y microspheres into the stomach fundus. Calibrated 90Y activities were infused into the main left gastric and the gastric artery arising from the splenic to yield predetermined fundal absorbed doses. Control animals underwent a sham procedure with saline and contrast. Weekly animal weight and serum ghrelin were measured along with post-euthanasia histologic analyses of mucosal integrity and ghrelin immunoreactive cell-density. Results: 90Y radioembolization was administered to six pigs in dosages from 46.3 to 105.1 MBq resulting in average fundal absorbed doses between 35.5 and 91.9 Gy. No animal showed any signs of pain or GI complication through the duration of the study. Ghrelin immunoreactive cell-density was significantly lower in treated vs. control animals in both the stomach fundus (13.5 vs 34.8, P < 0.05) and body (11.2 vs 19.8, P < 0.05). A trend towards decreased weight gain in treated animals as well as a decrease in explanted stomach volume was also noted. Conclusion: The safety and technical feasibility of radiation therapy using 90Y radioembolization as a potential treatment for obesity has been demonstrated at fundal absorbed doses over 90 Gy. Preliminary data is suggestive of short-term safety and potential efficacy, however, further animal studies are required. Project was funded by SIRTex medical ltd.

60 APPLIED LIFE SCIENCES↗

A GATE evaluation of the sources of error in quantitative {sup 90}Y PET

Purpose: Accurate reconstruction of the dose delivered by {sup 90}Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with {sup 90}Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of {sup 90}Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom-containing either {sup 90}Y or {sup 18}F were simulated using GATE. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the {sup 90}Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated {sup 90}Y data was slightly poorer than that for simulated {sup 18}F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of {sup 90}Y PET confirm that quantitative {sup 90}Y is achievable with the same approach as that used for {sup 18}F, and that there is likely very little margin for improvement by attempting to model aspects unique to {sup 90}Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tailored ultrasound propagation in microscale metamaterials via inertia design

The quasi-static properties of micro-architected (meta)materials have been extensively studied over the past decade, but their dynamic responses, especially in acoustic metamaterials with engineered wave propagation behavior, represent a new frontier. However, challenges in miniaturizing and characterizing acoustic metamaterials in high-frequency (megahertz) regimes have hindered progress toward experimentally implementing ultrasonic-wave control. Here, we present an inertia design framework based on positioning microspheres to tune responses of 3D microscale metamaterials. We demonstrate tunable quasi-static stiffness by up to 75% and dynamic longitudinal-wave velocities by up to 25% while maintaining identical material density. Using noncontact laser-based dynamic experiments of tunable elastodynamic properties and numerical demonstrations of spatio-temporal ultrasound wave propagation, we explore the tunable static and elastodynamic property relation. This design framework expands the quasi-static and dynamic metamaterial property space through simple geometric changes, enabling facile design and fabrication of metamaterials for applications in medical ultrasound and analog computing.

42 ENGINEERING↗

Microlens-Enhanced Substrate Patterning and MBE Growth of GaP Nanowires

In this paper we demonstrate the results on selective area growth of GaP nanowires via self-catalyzed growth method using molecular beam epitaxy (MBE) technique on patterned Si(111) substrates. The pattern fabrication method on a base of the photolithography process over an array of microspherical lenses has been studied theoretically and then optimized in order to obtain the nanostructures with controlled morphology. It was found that the positive resist thickness corresponding to the best achievable resolution in the subwavelength region is 250 nm in case of 1.5 μm silica spheres and excitation with 365 nm LED. The silica growth mask for selective epitaxy was fabricated. The ordered array of GaP nanowires was synthesized with MBE. Large scale ordering and selectivity of the growth technique is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wide bandgap photoconductor (SiC:V)-based optically addressed light valve for high fluence operation

Optically addressable light valves based on wide bandgap 4H- and 6H-SiC as photoconductors were designed to withstand higher operational laser fluences than the state of-the-art bismuth silicon oxide (BSO; Bi 12 SiO 20 ) based devices. Vanadium-doped SiC was selected as the photoconductors due to their reasonable photoresponsivity while many fold improvement in laser induced damage threshold as compared to BSO. The laser induced damage threshold values of the materials were measured after exposing ~ 200 sites on the samples to increasing levels of fluence of a gaussian pulsed Nd: YAG laser system (1064 nm) with a 5 Hz repetition rate. The measured damage threshold values for BSO, 4H- and 6H-SiC were 0.4 J/cm 2 , 1.75 J/cm 2 and 1.8 J/cm 2 , respectively. Photoconductive switches based on 4H and 6H-SiC samples were characterized at wavelengths of 380 nm, 405 nm, and 447 nm. The peak photoresponsivity values of the 4H- and 6H-SiC materials were measured to be under 380 nm and 405 nm, respectively. The photoconductor was bonded to a BK7 optical window with 5 μm diameter microspheres as spacers. A twisted nematic type E7 liquid crystal (LC) was filled in the 5 μm gap in a vacuum chamber. The desired alignment of the liquid crystal was achieved by mutually orthogonal orientation of LC alignment layers on the two mating faces (SiC and BK7). The fabricated devices were modulated using address beams of wavelengths 380 nm, 405 nm, and 447 nm. In conclusion, required transmission levels of > 90% was achieved for the fabricated OALVs for a sinusoidal voltage waveform that meets the lifetime requirement of the device.

36 MATERIALS SCIENCE↗