Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Reshaping of Truncated Pd Nanocubes: Energetic and Kinetic Analysis Integrating Transmission Electron Microscopy with Atomistic-Level and Coarse-Grained Modeling

Stability against reshaping of metallic fcc nanocrystals synthesized with tailored far-from-equilibrium shapes is key to maintaining optimal properties for applications such as catalysis. Yet Arrhenius analysis of experimental reshaping kinetics, and appropriate theory and simulation, is lacking. As such, we use TEM to monitor the reshaping of Pd nanocubes of ~25 nm side length between 410 °C (over ~4.5 h) and 440 °C (over ~0.25 h), extracting a high effective energy barrier of E eff ≈ 4.6 eV. We also provide an analytic determination of the energy variation along the optimal pathway for reshaping that involves transfer of atoms across the nanocube surface from edges or corners to form new layers on side {100} facets. The effective barrier from this analysis is shown to increase strongly with the degree of truncation of edges and corners in the synthesized nanocube. Theory matches experiment for the appropriate degree of truncation. In addition, we perform simulations of a stochastic atomistic-level model incorporating a realistic description of diffusive hopping for undercoordinated surface atoms, thereby providing a visualization of the initial reshaping process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Molecule Fluorescence Microscopy Reveals Energy Transfer Active versus Inactive Nanocrystal/Dye Conjugate Pairs

Defect-mediated energy transfer (EnT) is a radiative process that occurs between donor defect states in the forbidden bandgap of semiconductor nanocrystals (NCs) and dye molecules bound to their surfaces. The EnT efficiency depends on the number of dye molecules attached to each NC, the donor–acceptor distance, and the dipole orientation factor between the donor and acceptor, all of which vary across all individual NCs in a sample. While ensemble-level fluorescence spectroscopy measurements have provided average values for donor–acceptor distances, dye-to-NC ratios, and EnT rate constants, questions remain about the impact of donor/acceptor heterogeneity on observed EnT efficiencies. Notably, ensemble-level measurements cannot distinguish between bare NCs and EnT-active versus inactive NC/dye pairs in the same sample batch, limiting the ability to design systems with 100% EnT efficiency. To address this, we studied defect-mediated EnT between AlexaFluor 555 dye acceptors chemically bound to ZnO NC donors at the level of single molecules and single NCs. Interestingly, 20% of bound NC/dye pairs are EnT-inactive, likely contributing to residual defect photoluminescence (PL) observed in ensemble-level measurements and reducing overall EnT efficiency. Single particle-level ZnO defect PL and acceptor fluorescence trajectories exhibited distinct microfluctuations, which are absent in bare ZnO NCs. We hypothesized that our observations can be explained with a competitive dye fluorescence quenching pathway, possibly due to charge transfer between the excited state dye and the ZnO NC. Numerical simulations of single-molecule PL traces for this scenario produced microfluctuations consistent with the experimental results. These findings highlight the impact of sample heterogeneity on EnT processes and provide insights for designing light-harvesting systems with optimized EnT efficiency.

25 ENERGY STORAGE↗

Imaging mechanism for hyperspectral scanning probe microscopy via Gaussian process modelling

We investigate the ability to reconstruct and derive spatial structure from sparsely sampled 3D piezoresponse force microcopy data, captured using the band-excitation (BE) technique, via Gaussian Process (GP) methods. Even for weakly informative priors, GP methods allow unambiguous determination of the characteristic length scales of the imaging process both in spatial and frequency domains. We further show that BE data set tends to be oversampled in the spatial domains, with ~30% of original data set sufficient for high-quality reconstruction, potentially enabling faster BE imaging. At the same time, reliable reconstruction along the frequency domain requires the resonance peak to be within the measured band. This behavior suggests the optimal strategy for the BE imaging on unknown samples. Finally, we discuss how GP can be used for automated experimentation in SPM, by combining GP regression with non-rectangular scans.

47 OTHER INSTRUMENTATION↗

Nanoscale imaging of phonon dynamics by electron microscopy

Spatially resolved vibrational mapping of nanostructures is indispensable to the development and understanding of thermal nanodevices, modulation of thermal transport and novel nanostructured thermoelectric materials. Through the engineering of complex structures, such as alloys, nanostructures and superlattice interfaces, one can significantly alter the propagation of phonons and suppress material thermal conductivity while maintaining electrical conductivity. There have been no correlative experiments that spatially track the modulation of phonon properties in and around nanostructures due to spatial resolution limitations of conventional optical phonon detection techniques. Here we demonstrate two-dimensional spatial mapping of phonons in a single silicon–germanium (SiGe) quantum dot (QD) using monochromated electron energy loss spectroscopy in the transmission electron microscope. Tracking the variation of the Si optical mode in and around the QD, we observe the nanoscale modification of the composition-induced red shift. We observe non-equilibrium phonons that only exist near the interface and, furthermore, develop a novel technique to differentially map phonon momenta, providing direct evidence that the interplay between diffuse and specular reflection largely depends on the detailed atomistic structure: a major advancement in the field. Our work unveils the non-equilibrium phonon dynamics at nanoscale interfaces and can be used to study actual nanodevices and aid in the understanding of heat dissipation near nanoscale hotspots, which is crucial for future high-performance nanoelectronics.

36 MATERIALS SCIENCE↗

Imaging phonon dynamics with ultrafast electron microscopy: Kinematical and dynamical simulations

Ultrafast x-ray and electron scattering techniques have proven to be useful for probing the transient elastic lattice deformations associated with photoexcited coherent acoustic phonons. Indeed, femtosecond electron imaging using an ultrafast electron microscope (UEM) has been used to directly image the influence of nanoscale structural and morphological discontinuities on the emergence, propagation, dispersion, and decay behaviors in a variety of materials. Here, we describe our progress toward the development of methods ultimately aimed at quantifying acoustic-phonon properties from real-space UEM images via conventional image simulation methods extended to the associated strain-wave lattice deformation symmetries and extents. Using a model system consisting of pristine single-crystal Ge and a single, symmetric Lamb-type guided-wave mode, we calculate the transient strain profiles excited in a wedge specimen and then apply both kinematical- and dynamical-scattering methods to simulate the resulting UEM bright-field images. While measurable contrast strengths arising from the phonon wavetrains are found for optimally oriented specimens using both approaches, incorporation of dynamical scattering effects via a multi-slice method returns better qualitative agreement with experimental observations. Contrast strengths arising solely from phonon-induced local lattice deformations are increased by nearly an order of magnitude when incorporating multiple electron scattering effects. We also explicitly demonstrate the effects of changes in global specimen orientation on the observed contrast strength, and we discuss the implications for increasing the sophistication of the model with respect to quantification of phonon properties from UEM images.

36 MATERIALS SCIENCE↗

Direct imaging of plasma waves using ultrafast electron microscopy

A femtosecond plasma imaging modality based on a new development of ultrafast electron microscope is introduced. We investigated the laser-induced formation of high-temperature electron microplasmas and their subsequent non-equilibrium evolution. Based on a straightforward field imaging principle, we directly retrieve detailed information about the plasma dynamics, including plasma wave structures, particle densities, and temperatures. We discover that directly subjected to a strong magnetic field, the photo-generated microplasmas manifest in novel transient cyclotron echoes and form new wave states across a broad range of field strengths and different laser fluences. Intriguingly, the transient cyclotron waves morph into a higher frequency upper-hybrid wave mode with the dephasing of local cyclotron dynamics. The quantitative real-space characterizations of the non-equilibrium plasma systems demonstrate the feasibilities of a new microscope system in studying the plasma dynamics or transient electric fields with high spatiotemporal resolutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond stimulated Raman spectro-microscopy for probing chemical reaction dynamics in solid-state materials

Femtosecond stimulated Raman spectroscopy (FSRS) is a chemically specific vibrational technique that has the ability to follow structural dynamics during photoinduced processes such as charge transfer on the ultrafast timescale. FSRS has a strong background in following structural dynamics and elucidating chemical mechanisms; however, its use with solid-state materials has been limited. As photovoltaic and electronic devices rely on solid-state materials, having the ability to track the evolving dynamics during their charge transfer and transport processes is crucial. Following the structural dynamics in these solid-state materials will lead to the identification of specific chemical structures responsible for various photoinduced charge transfer reactions, leading to a greater understanding of the structure–function relationships needed to improve upon current technologies. Furthermore, isolating the specific nuclear motions and molecular structures that drive a desired physical process will provide a chemical blueprint, leading to the rational design and fabrication of efficient electronic and photovoltaic devices. In this perspective, we discuss technical challenges and experimental developments that have facilitated the use of FSRS with solid-state samples, explore previous studies that have identified structure–function relationships in charge transfer reactions, and analyze the future developments that will broaden and advance the field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic states of atomic vacancies in graphite probed by scanning tunneling microscopy

Intrinsic defects in graphitic materials, like vacancies and edges, have been expected to possess magnetic states from the many-body interaction of localized electrons. However, charge screening from graphite bulk carriers significantly reduces the localization effect and hinders the observation of those magnetic states. Here, we use an ultra-low-temperature scanning tunneling microscope with a high magnetic field to observe the magnetic states of atomic vacancies in graphite generated by ion sputtering. Scanning tunneling spectroscopy reveals localized states at the vacancies, which exhibit splitting at a certain magnetic field whose separation increases with the field strength. The transition is well described by the “Anderson model,” which describes the emergence of localized magnetic states inside the metallic reservoir through electron–electron interaction. The interaction strength is estimated to be between 1 meV and 3 meV, which is supported by the density functional theory calculation. The observation provides an important foundation for application of intrinsic defects to carbon-based spintronic devices.

36 MATERIALS SCIENCE↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗