Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METASTASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Gastric cancer tissue-derived mesenchymal stem cells impact peripheral blood mononuclear cells via disruption of Treg/Th17 balance to promote gastric cancer progression

Highlights: • GC-MSCs educate PBMCs to promote gastric cancer progression. • GC-MSCs disrupt the Treg/Th17 balance in PBMCs. • GC-MSCs induce Treg cell differentiation and suppress Th17 cell proliferation. Gastric cancer tissue-derived mesenchymal stem cells (GC-MSCs) are important resident stromal cells in the tumor microenvironment (TME) and have been shown to play a key role in gastric cancer progression. Whether GC-MSCs exert a tumor-promoting function by affecting anti-tumor immunity is still unclear. In this study, we used GC-MSC conditioned medium (GC-MSC-CM) to pretreat peripheral blood mononuclear cells (PBMCs) from healthy donors. We found that GC-MSC-CM pretreatment markedly reversed the inhibitory effect of PBMCs on gastric cancer growth in vivo, but did not affect functions of PBMCs on gastric cancer cell proliferation, cell cycle and apoptosis in vitro. PBMCs pretreated with GC-MSC-CM significantly promoted gastric cancer migration and epithelial-mesenchymal transition in vitro and liver metastases in vivo. Flow cytometry analysis showed that GC-MSC-CM pretreatment increased the proportion of Treg cells and reduced that of Th17 cells in PBMCs. CFSE labeling and naïve CD4{sup +} T cells differentiation analysis revealed that GC-MSC-CM disrupted the Treg/Th17 balance in PBMCs by suppressing Th17 cell proliferation and inducing differentiation of Treg cells. Overall, our collective results indicate that GC-MSCs impair the anti-tumor immune response of PBMCs through disruption of Treg/Th17 balance, thus providing new evidence that gastric cancer tissue-derived MSCs contribute to the immunosuppressive TME.

60 APPLIED LIFE SCIENCES↗

Migration-inducing gene-7 independently predicts poor prognosis of human osteosarcoma and is associated with vasculogenic mimicry

Highlights: • MIG-7 expression is associated with VM formation. • MIG-7 is an independent indicator of both overall and metastasis-free survival. • MIG-7 knockdown reduces osteosarcoma cells migration, invasion and VM formation. • MIG-7 knockdown didn’t affect osteosarcoma cell apoptosis or proliferation. • MIG-7 knockdown exhibits potent antimetastasis and anti-VM effects in vivo. Vasculogenic mimicry (VM) is a special type of vascular channel formed by tumor cells without endothelial cell participation. Migration-inducing gene 7 (MIG-7) plays an important role in regulating VM. In this study, immunohistochemical staining was used to detect MIG-7 in tissue specimens from 141 primary osteosarcoma patients, and the relationship between MIG-7 and VM was examined. Survival analysis were performed to evaluate the prognoses. MIG-7 knockdown osteosarcoma cells were used for cell proliferation, apoptosis, migration, invasiveness and VM formation assays. A spontaneously metastasizing cell line-derived orthotopic xenograft mouse model was established to evaluate the effect of MIG-7 knockdown on tumorigenesis, VM formation and lung metastasis. MIG-7 expression was associated with VM formation. There were significant differences in overall and metastasis-free survival between the MIG-7-positive and MIG-7-negative groups. The MIG-7 expression was shown to be an independent indicator of both overall and metastasis-free survival. In vitro knockdown of MIG-7 dramatically reduced migration, invasion and VM formation in osteosarcoma cells without any significant effect on cell proliferation and apoptosis. MIG-7 knockdown also exhibited potent antitumor, antimetastasis and anti-VM effects in the orthotopic mouse model of 143B osteosarcoma. Therefore, MIG-7 serves as an independent unfavorable prognostic indicator in osteosarcoma patients and MIG-7 is an important mediator of osteosarcoma VM formation.

60 APPLIED LIFE SCIENCES↗

Upregulated SCUBE2 expression in breast cancer stem cells enhances triple negative breast cancer aggression through modulation of notch signaling and epithelial-to-mesenchymal transition

Highlights: • SCUBE2 overexpression enhances the cancer stem cell-like and metastatic phenotypes. • SCUBE2 modulation of the Notch signaling pathway. • SCUBE2 high/ALDH+ TNBC cells exhibit enhanced tumorigenicity in vivo. Metastatic and/or recurrent breast carcinomas are leading causes of cancer-related death worldwide. Breast cancer stem cells (BCSCs) have been implicated in cancer metastases and progression, thus, the need for the discovery and development of effective BCSCs-specific therapies against metastatic and triple negative breast cancer (TNBC). The expression of SCUBE2, originally identified in vascular endothelia, then in several non-endothelial cell types, is downregulated in invasive breast carcinomas. However, the role of SCUBE2 in BCSCs remains unknown. This present study investigated the probable involvements of SCUBE2 in BCSCs and TNBC metastasis.

60 APPLIED LIFE SCIENCES↗

MiR-205–5p suppresses angiogenesis in gastric cancer by downregulating the expression of VEGFA and FGF1

Highlights: • MiR-205-5p was commonly downregulated in GC tissues from TCGA database and our hospital, and these events were associated with a worse TNM stagedistant metastasis and poor survival. • MiR-205-5p and CD31 expressions were negatively inter-related within GC tissues from TCGA database and our hospital. • GC cell lines expressed lower level of miR-205-5p significantly as compared with the normal gastric cell line. • MiR-205-5p upregulation significantly impaired proliferation and colony formation of GC cells and neovascularization induced by GC cells in vitro and in vivo. • The angiogenesis and ERK-signaling were depressed by VEGFA and FGF1 downregulation induced by miR-205-5p overexpression. The miR-205-5p inhibitor promoted malignant phenotypes by enhancing VEGFA and FGF1 expressions, as well as the activation of ERK-signaling. Anti-angiogenic therapy represents one of the most promising treatment modalities for human cancers. However, the response to antiangiogenic therapy in gastric cancer (GC) remains dismal. To help identify new strategies for antiangiogenic therapy in GC, we evaluated miR-205–5p expression in GC tissues from TCGA database and our hospital, and its functions in angiogenesis were explored in vitro and in vivo. We investigated miR-205–5p expression and microvessel densities (MVDs) in GC tissues and liver metastases from patients. The function and mechanisms of miR-205–5p were examined in human cell lines and in xenograft mouse models. Associations between miR-205–5p expression and clinical characteristics were analyzed using either Pearson's χ{sup 2} test or Fisher's exact test. Differences in overall survival (OS) distributions were evaluated using the log-rank test. Differences in measurement data were compared using Student's t-test and one-way ANOVA. We found that miR-205–5p expression was downregulated in GC tissues and was negatively correlated with CD31 expression in both TCGA and our clinical samples. GC cell lines expressed low levels of miR-205–5p, and miR-205–5p upregulation significantly impaired the proliferation and angiogenesis of GC cells. Moreover, vascular endothelial growth factor A (VEGFA) and fibroblast growth factor 1 (FGF1) expression and activation of extracellular-related kinase (ERK) signaling were suppressed by miR-205–5p. MiR-205–5p inhibition promoted malignant phenotypes by enhancing VEGFA and FGF1 expression, as well as the activation of ERK signaling. Angiogenesis and ERK signaling were decreased in response to VEGFA and FGF1 downregulation induced by miR-205–5p overexpression. The dual-luciferase reporter assay showed that VEGFA and FGF1 were direct targets of miR-205–5p. Xenograft mouse models revealed that miR-205–5p suppressed tumor growth by inhibiting neovascularization. Altogether, these results demonstrate that miR-205–5p suppresses angiogenesis in GC by attenuating the expression of VEGFA and FGF1, indicating that upregulation of miR-205–5p may represent as an antiangiogenic therapy for GC.

60 APPLIED LIFE SCIENCES↗

Preclinical tumor organoid models in personalized cancer therapy: Not everyone fits the mold

Highlights: • In personalized cancer medicine, each patient receives a specific treatment. • The tumor microenvironment and interpersonal differences can affect treatment. • Organoid culture systems fully recapitulate the tumor microenvironments. In contrast to conventional cancer treatment, in personalized cancer medicine each patient receives a specific treatment. The response to therapy, clinical outcomes, and tumor behavior such as metastases, tumor progression, carcinogenesis can be significantly affected by the heterogeneous tumor microenvironment (TME) and interpersonal differences. Therefore, using native tumor microenvironment mimicking models is necessary to improving personalized cancer therapy. Both in vitro 2D cell culture and in vivo animal models poorly recapitulate the heterogeneous tumor (immune) microenvironments of native tumors. The development of 3D culture models, native tumor microenvironment mimicking models, made it possible to evaluate the chemoresistance of tumor tissue and the functionality of drugs in the presence of cell-extracellular matrix and cell-cell interactions in a 3D construction. Various personalized tumor models have been designed to preserving the native tumor microenvironment, including patient-derived tumor xenografts and organoid culture strategies. In this review, we will discuss the patient-derived organoids as a native tumor microenvironment mimicking model in personalized cancer therapy. In addition, we will also review the potential and the limitations of organoid culture systems for predicting patient outcomes and preclinical drug screening. Finally, we will discuss immunotherapy drug screening in tumor organoids by using microfluidic technology.

60 APPLIED LIFE SCIENCES↗

Dynamic T{sub 2}-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1 Degree-Sign C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T{sub 2}, since T{sub 2} increases linearly in fat during heating. T{sub 2}-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T{sub 2}. Calibration of T{sub 2}-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T{sub 2} and temperature with a thermocouple. A positive T{sub 2} temperature dependence in bone marrow of 20 ms/ Degree-Sign C was observed. Dynamic T{sub 2}-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

60 APPLIED LIFE SCIENCES↗

Nurse exposure doses resulted from bone scintigraphy patient

Bone scintigraphy is used for displaying the radiologic undiagnosed bone lesions in nuclear medicine. It’s general indications are researching bone metastases, detection of radiographically occult fractures, staging and follow-up in primary bone tumors, diagnosis of paget’s disease, investigation of loosening and infection in orthopedic implants. It is applied with using {sup 99m}Tc labeled radiopharmaceuticals (e.g {sup 99m} Tc MDP,{sup 99m}Tc HEDP and {sup 99m}Tc HMDP). 20 -25 mCi IV radiotracer was injected into vein and radiotracer emits gamma radiation. Patient waits in isolated room for about 3 hours then a gamma camera scans radiation area and creates an image. When some patient’s situation is not good, patients are hospitalized until the scanning because of patients’ close contact care need. In this study, measurements were taken from ten patients using Geiger Muller counter. After these measurements, we calculated nurse’s exposure radiations from patient’s routine treatment, examination and emergency station.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiopharmaceuticals for SPECT cancer detection

The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Composite implants coated with biodegradable polymers prevent stimulating tumor progression

In this experiment we studied oncologic safety of model implants created using the solution blow spinning method with the use of the PURASORB PL-38 polylactic acid polymer and organic mineral filler which was obtained via laser ablation of a solid target made of dibasic calcium phosphate dihydrate. For this purpose the implant was introduced into the area of Wistar rats’ iliums, and on day 17 after the surgery the Walker sarcoma was transplanted into the area of the implant. We evaluated the implant’s influence on the primary tumor growth, hematogenous and lymphogenous metastasis of the Walker sarcoma. In comparison with sham operated animals the implant group demonstrated significant inhibition of hematogenous metastasis on day 34 after the surgery. The metastasis inhibition index (MII) equaled 94% and the metastases growth inhibition index (MGII) equaled 83%. The metastasis frequency of the Walker sarcoma in para aortic lymph nodes in the implant group was not statistically different from the control frequency; there was also no influence of the implant on the primary tumor growth noted. In case of the Walker sarcoma transplantation into the calf and the palmar pad of the ipsilateral limb to the one with the implant in the ilium, we could not note any attraction of tumor cells to the implant area, i.e. stimulation of the Walker sarcoma relapse by the implant. Thus, the research concluded that the studied implant meets the requirements of oncologic safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal neutron irradiation field design for boron neutron capture therapy of human explanted liver

The selective uptake of boron by tumors compared to that by healthy tissue makes boron neutron capture therapy (BNCT) an extremely advantageous technique for the treatment of tumors that affect a whole vital organ. An example is represented by colon adenocarcinoma metastases invading the liver, often resulting in a fatal outcome, even if surgical resection of the primary tumor is successful. BNCT can be performed by irradiating the explanted organ in a suitable neutron field. In the thermal column of the Triga Mark II reactor at Pavia University, a facility was created for this purpose and used for the irradiation of explanted human livers. The neutron field distribution inside the organ was studied both experimentally and by means of the Monte Carlo N-particle transport code (MCNP). The liver was modeled as a spherical segment in MCNP and a hepatic-equivalent solution was used as an experimental phantom. In the as-built facility, the ratio between maximum and minimum flux values inside the phantom ({phi}{sub max}/{phi}{sub min}) was 3.8; this value can be lowered to 2.3 by rotating the liver during the irradiation. In this study, the authors proposed a new facility configuration to achieve a uniform thermal neutron flux distribution in the liver. They showed that a {phi}{sub max}/{phi}{sub min} ratio of 1.4 could be obtained without the need for organ rotation. Flux distributions and dose volume histograms were reported for different graphite configurations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical note: The calibration of {sup 90}Y-labeled SIR-Spheresusing a nondestructive spectroscopic assay

{sup 90}Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq{+-}10% and is not independently verified by the end user. This technical note shows that the results of a nondestructive spectroscopic assay of a SIR-Spheressample was 26% higher than the activity stated by the manufacturer. This difference should not impact the current empirical prescription method but may be problematic for patient-specific dosimetry applications, such as image-based dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated treatment planning for a dedicated multi-source intracranial radiosurgery treatment unit using projected gradient and grassfire algorithms

Purpose: The purpose of this work is to develop a framework to the inverse problem for radiosurgery treatment planning on the Gamma Knife{sup Registered-Sign} Perfexion Trade-Mark-Sign (PFX) for intracranial targets. Methods: The approach taken in the present study consists of two parts. First, a hybrid grassfire and sphere-packing algorithm is used to obtain shot positions (isocenters) based on the geometry of the target to be treated. For the selected isocenters, a sector duration optimization (SDO) model is used to optimize the duration of radiation delivery from each collimator size from each individual source bank. The SDO model is solved using a projected gradient algorithm. This approach has been retrospectively tested on seven manually planned clinical cases (comprising 11 lesions) including acoustic neuromas and brain metastases. Results: In terms of conformity and organ-at-risk (OAR) sparing, the quality of plans achieved with the inverse planning approach were, on average, improved compared to the manually generated plans. The mean difference in conformity index between inverse and forward plans was -0.12 (range: -0.27 to +0.03) and +0.08 (range: 0.00-0.17) for classic and Paddick definitions, respectively, favoring the inverse plans. The mean difference in volume receiving the prescribed dose (V{sub 100}) between forward and inverse plans was 0.2% (range: -2.4% to +2.0%). After plan renormalization for equivalent coverage (i.e., V{sub 100}), the mean difference in dose to 1 mm{sup 3} of brainstem between forward and inverse plans was -0.24 Gy (range: -2.40 to +2.02 Gy) favoring the inverse plans. Beam-on time varied with the number of isocenters but for the most optimal plans was on average 33 min longer than manual plans (range: -17 to +91 min) when normalized to a calibration dose rate of 3.5 Gy/min. In terms of algorithm performance, the isocenter selection for all the presented plans was performed in less than 3 s, while the SDO was performed in an average of 215 min. Conclusions: PFX inverse planning can be performed using geometric isocenter selection and mathematical modeling and optimization techniques. The obtained treatment plans all meet or exceed clinical guidelines while displaying high conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13–125 Gy).Conclusions: A three-dimensional inpatient dose reconstruction method has been developed that is based on the PET/CT data of a patient treated with {sup 90}Y microspheres. It allows for a complete description of the absorbed dose by the tumor and critical structures. It represents the first step in building predictive models for treatment outcomes for patients receiving this therapeutic modality as well as it allows for better analysis of patients' dose response and will ultimately improve future treatment administration.

61 RADIATION PROTECTION AND DOSIMETRY↗

MR-guided focused ultrasound surgery, present and future

MR-guided focused ultrasound surgery (MRgFUS) is a quickly developing technology with potential applications across a spectrum of indications traditionally within the domain of radiation oncology. Especially for applications where focal treatment is the preferred technique (for example, radiosurgery), MRgFUS has the potential to be a disruptive technology that could shift traditional patterns of care. While currently cleared in the United States for the noninvasive treatment of uterine fibroids and bone metastases, a wide range of clinical trials are currently underway, and the number of publications describing advances in MRgFUS is increasing. However, for MRgFUS to make the transition from a research curiosity to a clinical standard of care, a variety of challenges, technical, financial, clinical, and practical, must be overcome. This installment of the Vision 20/20 series examines the current status of MRgFUS, focusing on the hurdles the technology faces before it can cross over from a research technique to a standard fixture in the clinic. It then reviews current and near-term technical developments which may overcome these hurdles and allow MRgFUS to break through into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-04: A Data-Driven, Response-Based, Multi-Criteria Decision Support System for Personalized Lung Radiation Treatment Planning

Purpose: To develop a decision support tool to predict a patient's potential overall survival (OS) and radiation induced toxicity (RIT) based on clinical factors and responses during the course of radiotherapy, and suggest appropriate radiation dose adjustments to improve therapeutic effect. Methods: Important relationships between a patient's basic information and their clinical features before and during the radiation treatment are identified from historical clinical data by using statistical learning and data mining approaches. During each treatment period, a data analysis (DA) module predicts radiotherapy features such as time to local progression (TTLP), time to distant metastases (TTDM), radiation toxicity to different organs, etc., under possible future treatment plans based on patient specifics or responses. An information fusion (IF) module estimates intervals for a patient's OS and the probabilities of RIT from a treatment plan by integrating the outcomes of module DA. A decision making (DM) module calculates “satisfaction” with the predicted radiation outcome based on trade-offs between OS and RIT, and finds the best treatment plan for the next time period via multi-criteria optimization. Results: Using physical and biological data from 130 lung cancer patients as our test bed, we were able to train and implement the 3 modules of our decision support tool. Examples demonstrate how it can help predict a new patient's potential OS and RIT with different radiation dose plans along with how these combinations change with dose, thus presenting a range of satisfaction/utility for use in individualized decision support. Conclusion: Although the decision support tool is currently developed from a small patient sample size, it shows the potential for the improvement of each patient's satisfaction in personalized radiation therapy. The radiation treatment outcome prediction and decision making model needs to be evaluated with more patients and demonstrated for use in radiation treatments for other cancers. P01-CA59827;R01CA142840.

60 APPLIED LIFE SCIENCES↗

SU-E-T-84: Comparison of Three Different Systems for Patient-Specific Quality Assurance: Cranial Stereotactic Radiosurgery Using VMAT with Multiple Non Coplanar Arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered. The purpose of the study is to compare three different dosimeters for pre-treatment QA. Methods: Nineteen patients (affected by neurinomas, brain metastases, and by meningiomas) were treated with VMAT plans computed on a Monte Carlo based TPS. Gafchromic films inside a slab phantom (GF), 3-D cylindrical phantom with two orthogonal diodes array (DA), and 3-D cylindrical phantom with a single rotating ionization chambers array (ICA), have been evaluated. The dosimeters are, respectively, characterized by a spatial resolution of: 0.4 (in our method), 5 and 2.5 mm. For GF we used a double channel method for calibration and reading protocol; for DA and ICA we used the 3-D dose distributions reconstructed by the two software sold with the dosimeters. With the need of a common system for analyze different measuring approaches, we used an in-house software that analyze a single coronal plane in the middle of the phantoms and Gamma values (2% / 2 mm and 3% / 3 mm) were computed for all patients and dosimeters. Results: The percentage of points with gamma values less than one was: 95.7% for GF, 96.8% for DA and 95% for ICA, using 3%/3mm criteria, and 90.1% for GF, 92.4% for DA and 92% for ICA, using 2% / 2mm gamma criteria. Tstudent test p-values obtained by comparing the three datasets were not statistically significant for both gamma criteria. Conclusion: Gamma index analysis is not affected by different spatial resolution of the three dosimeters.

60 APPLIED LIFE SCIENCES↗

SU-E-T-150: End to End Tests On the First Clinical EDGETM

Purpose: To quantify the sub millimeter overall accuracy of EDGETM, the dedicated linac based SRS/SABR treatment platform from Varian, using a novel End-to-End (E2E) test phantom. Methods: The new E2E test phantom developed by Varian consists of a cube with an outer dimension of 15x15x15 cm3. The phantom is equipped with an exchangable inner cube (7×7×7 cm3) to hold radiochromic films or a tungsten ball (diameter = 5 mm) for Winston-Lutz tests. 16 ceramic balls (diameter = 5 mm) are embedded in the outer cube. Three embedded Calypso transponders allow for Calypso based monitoring. The outer surface of the phantom is tracked using the Optical Surface Monitoring System (OSMS). The phantom is positioned using kV, MV and CBCT images. A simCT of the phantom was acquired and SRS/SABR plans were treated using the new phantom on the first clinical installed EDGETM. As a first step a series of EPID based Winston-Lutz tests have been performed. As a second step the calculated dose distribution applied to the phantom was verified with radiochromic films in orthogonal planes. The measured dose distribution is compared with the calculated (Eclipse) one based on the known isocenter on both dose distributions. The geometrical shift needed to match both dose distributions is the overall accuracy and is determined using dose profiles, isodose lines or gamma pass rates (3%, 1 mm). Results: Winston-Lutz tests using the central tungsten BB demonstrated a targeting accuracy of 0.44±0.18mm for jaw (2cm × 2cm) defined 0.39±0.19mm for MLC (2cm × 2cm) defined and 0.37±0.15mm for cone (12.5 mm) defined fields. A treated patient plan (spinal metastases lesion with integrated boost) showed a dosimetric dose localization accuracy of 0.6mm. Conclusion: Geometric and dosimetric E2E tests on EDGETM, show sub-millimeter E2E targeting and dose localisation accuracy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-269: Quality Assurance of Spine Volumetric Modulated Arc Therapy with Flattening Filter Free Beams Using Gafchromic EBT3 Films

Purpose: We implemented the Gafchromic film-based patient specific QA of volumetric modulated arc therapy (VMAT) with flattening-filter free (FFF) beams for spine metastases and validated the accuracy of fast arc delivery. Methods: EBT3 films and a homemade cylindrical QA phantom were employed for dosimetric verification of VMATs. For 14 FFF VMAT plans (10 with 10-MV FFF beams and 4 with 6-MV FFF beams), the doses were recalculated on the phantom and delivered by a TrueBeam STx accelerator equipped with a high-definition 120 leaf MLC. The EBT3 films were scanned using an Epson 10000XL scanner through the FilmQA Pro software. All the irradiated film images were converted to dose map using a calibration response curve. The resulting dose map of film measurement was compared with treatment plan and evaluated using gamma analysis with dose tolerance of 2% within 2 mm. In addition, the point-dose measurement in the phantom using an ion chamber was evaluated as a reference in a ratio of measured and planned doses. Results: The gamma pass rates averaged over all FFF plans for composite-field measurements were 96.0 ± 3.6% (88.9%–99.5%). When adopting a tolerance level of 3% - 3 mm, the gamma pass rates were improved with the ranges from 98% to 100%. In addition, dose profiles and dose distributions showed that spinal cord was protected by the rapid dose fall-off and by delivering the treatment with high precision. In point-dose measurements, the average differences between the measured and planned doses were 0.5% ± 1.0% of the prescription dose. Conclusion: We demonstrated that Gafchromic EBT3 film would be an effective patient-specific QA tool, especially for VMAT of spine SBRT with treatment of small fields and highly gradient dose distributions. The results of film QA verified that the dosimetric accuracy of spine SBRT utilizing RapidArc with FFF beams in our institution is reliable.

60 APPLIED LIFE SCIENCES↗