Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAMMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Initial and Long-Term Results of Endovascular Therapy for Chronic Total Occlusion of the Subclavian Artery

Purpose: To study the initial and long-term results of angioplasty and primary stenting for the treatment of chronic total occlusion (CTO) of the subclavian artery (SA). Materials and Methods: From January 1999 to February 2010, 56 patients (25 men with a mean age of 58 {+-} 8 years) underwent endovascular treatment for CTO of the SA. Duplex scans and arteriograms confirmed occlusion in all cases. Indications for recanalization were subclavian steal syndrome in 33 patients (58.1%), arm claudication in 13 patients (23.2%), and coronary ischemia in 7 patients (12.5%) who had a history of previous coronary artery bypass grafting that included left internal thoracic artery graft. Three patients (5.4%) were treated before the scheduled coronary artery bypass surgery, which included left internal thoracic artery graft. After successful recanalization, all arteries were stented, and all of the patients were followed-up at 1, 3, 6, and 12 months after surgery and annually thereafter. Results: Successful recanalization of the SA was achieved in 46 patients (82.1%), and the complication rate was 7.1%. During follow-up (mean 40 {+-} 26 months; range 2 to 125), the primary patency rates after 1 and 3 years were 97.9% and 82.7%, respectively. At the end of follow-up, 76% of the arteries showed no evidence of restenosis. Univariate analysis failed to identify any variable predictive of long-term patency of successfully recanalized SA. Conclusion: Percutaneous transluminal angioplasty with stenting of the complete total occlusion of the SA is a safe and effective procedure associated with low risks and good long-term results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Arterial Embolization with Doxorubicin-Loaded Superabsorbent Polymer Microspheres in a Rabbit Liver Tumor Model

Objectives: The pharmacokinetic profile after hepatic arterial embolization with superabsorbent microspheres (QuadraSpheres) loaded with doxorubicin was studied. Methods: Rabbits with hepatic VX2 tumors were treated with intra-arterial administration of QuadraSpheres loaded with doxorubicin, or transarterial chemoembolization (TACE) using doxorubicin, Lipiodol and Embospheres, or hepatic arterial infusion (HAI) of doxorubicin. Tumor specimens were evaluated by fluorescence microscopy, and plasma and tumor concentrations of doxorubicin were measured. Results: The peak plasma concentration of doxorubicin was lower in the QuadraSphere group (309.9 ng/ml) than in the HAI (673.4 ng/ml) or TACE (360.5 ng/ml) groups, suggesting higher tumor retention in the QuadraSphere group. Intratumoral doxorubicin levels declined to negligible levels at 1 and 3 days after treatment, respectively, in the HAI and TACE groups. In the QuadraSphere groups, intratumoral doxorubicin level declined after day 1, but was still detectable at 14 days after treatment and was higher than that in the other groups at 1, 3, and 7 days. Intratumoral doxorubicin fluorescence was detected at all time points in the QuadraSphere group, but only at 1 day after treatment in the TACE group. Conclusions: Hepatic arterial administration of doxorubicin-loaded QuadraSpheres enables the sustained release of doxorubicin to hepatic tumors.

60 APPLIED LIFE SCIENCES↗

Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization

Purpose: We evaluated the effects of the combination of Tirapazamine (TPZ), activated preferentially under hypoxic conditions, and gelatin microspheres (GMS) on the tumor growth ratio in rabbits. Methods: We assigned 20 liver tumor-bearing Japanese white rabbits to 4 equal groups. Group 1 received 1 ml of saline intra-arterially (i.a.) and 20 ml of saline intraperitoneally (i.p.; saline group). Group 2 was injected with GMS i.a. and 20 ml saline i.p. (GMS group). Group 3 received 1 ml of saline i.a. and 300 mg/m{sup 2} of TPZ i.p. (TPZ group), and group 4 was treated with GMS i.a. and 300 mg/m{sup 2} of TPZ i.p. (GMS + TPZ group). The infusion of GMS was stopped when the blood flow stagnated. Before and 7 days after treatment, the liver tumor volumes were measured as the total number of pixels on 0.3Tesla (T) magnetic resonance imaging (MRI) scans. Results: The tumor growth ratio (mean {+-} standard deviation) of the saline, GMS, TPZ, and GMS + TPZ groups was 519.15 {+-} 93.78, 279.24 {+-} 91.83, 369.78 {+-} 95.73, and 119.87 {+-} 17.62, respectively. The difference between the GMS + TPZ group and the other groups was statistically significant (P < 0.05). Conclusions: Our results show that the combination of TPZ i.p. and GMS i.a. enhanced the antitumor effect of TPZ. This procedure may represent a new alternative treatment for patients with hepatic cell carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 {+-} 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD's tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine

Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histological analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Results of Catheter-Directed Ultrasound-Accelerated Thrombolysis for Thromboembolic Obstructions of the Aortofemoral Arteries: A Feasibility Study

Purpose: This article reports the 30-day technical and clinical outcome of ultrasound (US)-accelerated thrombolysis in patients with aortofemoral arterial thromboembolic obstructions. Methods: A prospective cohort study was conducted from December 2008 to December 2009 of patients who were treated with US-accelerated thrombolysis for thromboembolic obstructions of aortofemoral arteries or bypasses. Urokinase was infused in a dosage of 100,000 IU per hour. Twice daily, a control angiography was performed. Thirty-day follow-up consisted of duplex scanning, combined with magnetic resonance angiography. Results: The study included 21 consecutive patients (20 men; median age, 66 (range, 52-80) years) with 24% artery versus 76% bypass occlusions. Median duration of symptoms was 11 (range, 7-140) days. Median occlusion length was 32 (range, 6-80) cm. In 20 patients (95%), an US-accelerated thrombolysis catheter could be successfully placed. In one patient, placement of an US-accelerated thrombolysis catheter was technically not feasible, and therefore a standard catheter was placed. Median thrombolysis time was 26.5 (range, 8.5-72) hours. Complete thrombolysis (>95% lysis of thrombus) was achieved in 20 patients; in 9 patients within 24 hours. Median ankle-brachial index (ABI) increased from 0.28 (range, 0-0.85) to 0.91 (range, 0.58-1.35). One patient had a thromboembolic complication and needed surgical intervention. No hemorrhagic complications, and no deaths occurred. At 30-day follow-up, 17 of 21 patients (81%) had a patent artery or bypass. Conclusions: This feasibility study showed a high technical success rate of US-accelerated thrombolysis for aortofemoral arterial obstructions. US-accelerated thrombolysis led to complete lysis within 24 hours in almost half of patients, with a low 30-day major complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Decompression of Lumbar Spinal Stenosis with a New Interspinous Device

Objective: This study was designed to evaluate the feasibility of the implantation of a new interspinous device (Falena) in patients with lumbar spinal stenosis. The clinical outcomes and imaging results were assessed by orthostatic MR during an up to 6-month follow-up period. Methods: Between October 2008 and February 2010, the Falena was implanted at a single level in 26 patients (17 men; mean age, 69 (range, 54-82) years) who were affected by degenerative lumbar spinal stenosis. All of the patients were clinically evaluated before the procedure and at 1 and 3 months. Furthermore, 20 patients have completed a 6-month follow-up. Pain was assessed before and after the intervention using the Visual Analogue Scale score and the Oswestry Disability Index questionnaire. Orthostatic MR imaging was performed before the implantation and at 3 months to assess the correlation with the clinical outcome. Results: The mean ODI score decreased from 48.9 before the device implantation to 31.2 at 1 month (p < 0.0001). The mean VAS score decreased from 7.6 before to 3.9 (p < 0.0001) at 1 month and 3.6 at 3 months after the procedure (p = 0.0115). These values were stable at 6 months evaluation. No postimplantation major complications were recorded. MRI evaluation documented in most cases an increased size of the spinal canal area. Similarly a bilateral foraminal area improvement was found. The variation of the intervertebral space height measured on the posterior wall was not significant. Conclusions: In our preliminary experience with the Falena in a small cohort of patients, we obtained clinical and imaging results aligned to those reported with similar interspinous devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Peripheral Vascular Malformations in Children: Long-Term Clinical Outcome

Purpose: This study was designed to assess the rate of complications and clinical failure at 3 and 12 months after percutaneous treatment of vascular malformations in children. Furthermore, we describe patient satisfaction of treatment results during 5 years of follow-up. Methods: In a retrospective cohort study, we evaluated 26 patients younger than aged 19 years who were treated for symptomatic vascular malformations. Data on treatment outcomes and patient satisfactions were obtained with a precoded structured questionnaire. Patient files and imaging data were retrieved to obtain information regarding the vascular malformations and treatment. Clinical success was defined as disappearance or partial improvement of the complaints. Patient satisfaction was declared whenever patients answered in the questionnaire that they were satisfied with the treatment results. Results: Of 26 eligible patients, we included 23 (88%). The mean follow-up was 36 (range, 15-127) months. Posttreatment, 87% (20/23; 95% confidence interval (CI), 66-97%) of patients reported clinical success at 3 months. At 1, 2, 3, 4, and 5 years of follow-up this percentage was 74%, 59%, 59%, 59%, and 59%, respectively. Eleven (48%, 95% CI 27-69%) patients had experienced complications and 22% (95% CI 7-44%) had major complications, of which 5 had required additional treatment. In all, 83% (19/23) of the patients reported satisfaction with the treatment. Conclusions: Percutaneous treatment of vascular malformations improved clinical symptoms in 87% of the patients at 3 months and were sustainable for half of all patients during a 5-year follow-up period. However, major complications were seen in 22%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes ('Temperature Control' and 'Power Control') on Procedural Outcome

Purpose: This study was designed to analyze the effect of two different ablation modes ('temperature control' and 'power control') of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 {+-} 0 s in group I and 102 {+-} 21 s in group II. Long axis diameter was 20.3 {+-} 4.6 mm in group I and 19.8 {+-} 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 {+-} 2 mm in group I and 10.5 {+-} 2.4 mm in group II (NS). Circularity was 0.5 {+-} 0.1 in group I and 0.5 {+-} 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Thrombolysis and Spasmolysis of Acute Leg Ischemia after Accidental Intra-arterial Injection of Dissolved Flunitrazepam Tablets

A 37-year-old man with known intravenous drug abuse presented in the surgical ambulatory care unit with acute leg ischemia after accidental intra-arterial injection of dissolved flunitrazepam tablets into the right femoral artery. A combination of anticoagulation, vasodilatation, and local selective and superselective thrombolysis with urokinase was performed to salvage the leg. As a result of the severe ischemia-induced pain, the patient had to be monitored over the complete therapy period on the intensive care unit with permanent administration of intravenous fluid and analgetics. We describe the presenting symptoms and the interventional technique, and we discuss the recent literature regarding the management of accidental intra-arterial injection of dissolved flunitrazepam tablets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination Therapy of Transcatheter Arterial Chemoembolization and Arterial Administration of Antiangiogenesis on VX2 Liver Tumor

Purpose: This study was designed to evaluate the antitumorigenic efficiency of Endostar (an antiangiogenic agent) arterially administrated combined with transcatheter arterial chemoembolization (TACE) on liver tumor, and validation of perfusion CT for quantitative measurements of the results.Experimental DesignThirty rabbits bearing VX2 liver tumors were randomly and equally distributed into three groups. One of the following treatment protocols was performed in each group: 1) group 1 was treated with TACE and simultaneously arterially administrated Endostar; 2) group 2 with TACE alone, and 3) a control group that had saline injected through hepatic artery. Routine CT scan was performed before treatment, and perfusion CT imaging was performed 2 weeks after treatment. Immunohistochemical biomarkers of microvascular density (MVD) and the expression of vascular endothelial growth factor (VEGF) were measured for assessments of angiogenesis. Results: We observed a statistically significant reduction from the control in the volume, growth rate, and size of the tumor 2 weeks after treatment with both TACE plus Endostar and with TACE alone (P < 0.01). Although there was no statistically significant difference in tumor size between the group with TACE plus Endostar and the group with TACE alone (P > 0.05), MVD and VEGF were significantly less expressed in the TACE plus Endostar group than both groups with TACE alone and the control group (P < 0.01). Blood flow (BF), blood volume (BV), and permeability-surface area products (PS) in the group with TACE plus Endostar on perfusion CT were significantly higher than other two groups (P < 0.05), which were positively correlated with the MVD and VEGF values (P < 0.05). Conclusions: TACE with arterial administration of Endostar simultaneously significantly inhibited the angiogenesis biomarkers associated with TACE in a rabbit model bearing VX2 liver tumor, which indicates that the combined treatment protocol may have potential synergistic effects on liver cancer. It also is suggested that perfusion CT may be useful for monitoring antiangiogenic/antivascular treatment in the liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unenhanced MR Angiography of Uterine and Ovarian Arteries after Uterine Artery Embolization: Differences between Patients with Incomplete and Complete Fibroid Infarction

Purpose: To compare the status of uterine and ovarian arteries after uterine artery embolization (UAE) in patients with incomplete and complete fibroid infarction via unenhanced 3D time-of-flight magnetic resonance (MR) angiography. Materials and Methods: Thirty-five consecutive women (mean age 43 years; range 26-52 years) with symptomatic uterine fibroids underwent UAE and MR imaging before and within 2 months after UAE. The patients were divided into incomplete and complete fibroid infarction groups on the basis of the postprocedural gadolinium-enhanced MR imaging findings. Two independent observers reviewed unenhanced MR angiography before and after UAE to determine bilateral uterine and ovarian arterial flow scores. The total arterial flow scores were calculated by summing the scores of the 4 arteries. All scores were compared with the Mann-Whitney test. Results: Fourteen and 21 patients were assigned to the incomplete and complete fibroid infarction groups, respectively. The total arterial flow score in the incomplete fibroid infarction group was significantly greater than that in the complete fibroid infarction group (P = 0.019 and P = 0.038 for observers 1 and 2, respectively). In 3 patients, additional therapy was recommended for insufficient fibroid infarction. In 1 of the 3 patients, bilateral ovarian arteries were invisible before UAE but seemed enlarged after UAE. Conclusion: The total arterial flow from bilateral uterine and ovarian arteries in patients with incomplete fibroid infarction is less well reduced than in those with complete fibroid infarction. Postprocedural MR angiography provides useful information to estimate the cause of insufficient fibroid infarction in individual cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Treatment of Large Hepatocellular Carcinoma with Transcatheter Arterial Chemoembolization and Percutaneous Ethanol Injection with a Multipronged Needle: Experimental and Clinical Investigation

Purpose: This study was designed to evaluate the usefulness of percutaneous ethanol injection (PEI) with a multipronged needle for the treatment of large hepatocellular carcinoma (HCC). An experimental animal study and a clinical investigation were performed. Methods: In the experimental study, 20 ml of 99.5% ethanol was injected into porcine liver in vivo with a multipronged needle (n = 5) or a straight needle (n = 5), and the volumes of coagulation necrosis were compared. In the clinical investigation, PEI was performed in 17 patients (10 men, 7 women; mean age 73.4 {+-} 6.7 years) with single, large HCC (mean tumor diameter, 47.2 {+-} 11.5 mm; range, 32-70 mm) by using a multipronged needle. Fifteen of 17 patients received transarterial chemoembolization (TACE) before PEI. Results: The volume of coagulation in porcine liver in vivo was significantly increased with the multipronged needle compared with the straight needle (longest perpendicular diameters, 34.2 {+-} 3.6 mm Multiplication-Sign 30.2 {+-} 3.6 mm vs. 22.6 {+-} 2.5 mm Multiplication-Sign 19 {+-} 2.2 mm, respectively; P < 0.05). In the clinical trial, initial complete response (CR) of the tumor was achieved in 17 of 17 patients, 7 of whom required two PEI sessions. During the follow-up, local recurrence was detected in 4 of 17 patients at 3-19 months after the procedure, for a rate of sustained local CR of 76%. No major complication occurred. Conclusions: Use of a multipronged needle substantially increases the volume of coagulation in vivo with respect to the conventional PEI technique. Combined TACE and PEI with multipronged needles is a safe and effective option for percutaneous treatment of single, large HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interlocking Detachable Coil Embolization by Technique of Dumbbell-Shaped Framing and Filling and Bridge Formation Under Balloon Dilatation for Huge Conglomerate Pulmonary Arteriovenous Malformation

A 60-year-old woman presented with a conglomerate pulmonary arteriovenous malformation (PAVM) size 8.2 Multiplication-Sign 7.2 cm on chest X-ray. Feeding arteries were A{sub a}{sup 7} and A{sub b}{sup 7}, A{sup 8}, and A{sup 10}. The diameter and length of the A{sub b}{sup 7} neck were 15.5 and 16 mm, respectively. After percutaneous transcatheter embolization of A{sup 8} and A{sup 10}, PTE of A{sub a}{sup 7} and A{sub b}{sup 7} was conducted under balloon occlusion with interlocking detachable coils using a technique of dumbbell-shaped framing and filling, making a bridge from A{sub b}{sup 7} to the trunk of A{sup 9} and A{sup 10}across A{sup 7}. Follow-up computed tomography 10 months after treatment showed marked shrinkage of the PAVM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pilot Study of Uterine Artery Embolization with Tris-Acryl Gelatin Microspheres in Guinea Pigs

Objective: This study was designed to establish guinea pigs as an animal model for uterine artery embolization (UAE) with tris-acryl gelatin microspheres (TAGM). Methods: Twenty-five female adult guinea pigs were randomly divided into two groups, including a uterine artery casting mould group (n = 10) and a UAE group (n = 15). Pelvic angiography and vascular casting mould were performed in the first group. The anatomical characters of the pelvic cavity in guinea pigs were described. In the second group, the technical feasibility of performing UAE with TAGM in guinea pigs was investigated. The histopathological slides of the uterus of guinea pigs after UAE were examined to inspect the outcomes of UAE. Results: The uterine artery springs from the internal iliac artery, ascends tortuously along the cervix, and gives off vertically 8-10 branches to the cervix uteri and uterine horns. The diameters of the trunk of the uterine artery and its first branch were 0.32 {+-} 0.027 mm and 0.14 {+-} 0.01 mm, respectively. For UAE animals, the dosages of 40-120 and 100-300 {mu}m TAGM were 0.033 {+-} 0.003 ml and 0.015 {+-} 0.002 ml, respectively. On histopathological slides, embosphere particles were found in the first branches of the uterine artery, the subserous arteries, and the intramural arteries. Inflammatory reactions in the uterus were common in guinea pigs after UAE. Local or dispersed areas of necrosis in uterus also were observed in a few guinea pigs. Conclusions: Guinea pigs are an appropriate and feasible model for UAE with TAGM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Preclinical Study of the Safety and Efficacy of Occlusin Trade-Mark-Sign 500 Artificial Embolization Device in Sheep

Introduction: This study evaluated the safety, effectiveness, and biodegradation of a new embolic agent, Occlusin Trade-Mark-Sign 503 Artificial Embolization Device (OCL 503). The agent consists of biodegradable poly-lactic-co-glycolic acid microspheres (150-212 {mu}m) coated with type I bovine collagen and was compared with Embosphere{sup Registered-Sign} Microspheres (300-500 {mu}m) in this controlled study of uterine artery embolization (UAE) in sheep. Methods: Unilateral UAE was performed in 32 adult ewes randomly assigned. Vessels were embolized to effective stasis. The cohort was divided into four groups, which were sacrificed at 1, 3, 6, and 12 months. Results: Both agents were 100% effective in achieving stasis. At 6 months, all OCL 503-treated arteries were occluded, the microspheres degraded with time, and at 12 months all four animals examined demonstrated recanalization. OCL 503 was found in the untreated uterine artery in one animal with no other evidence of non target embolization. In the Embosphere-treated group, all vessels remained occluded and microspheres were detected in the contralateral uterine artery in 6 of 15 examined vessels and in 10 vaginal, 2 ovarian, and 1 vesical artery. No procedural-related complications were seen in either group. Conclusions: OCL 503 is as effective an embolic agent as Embosphere{sup Registered-Sign} Microspheres when embolizing ovine uterine arteries and resorbs with time, allowing recanalization of the treated arteries. No device-related issues or adverse events were observed.

60 APPLIED LIFE SCIENCES↗

Lung Radiofrequency Ablation for the Treatment of Unresectable Recurrent Non-Small-Cell Lung Cancer After Surgical Intervention

Purpose: A retrospective evaluation was done of clinical utility of lung radiofrequency (RF) ablation in recurrent non-small-cell lung cancer (NSCLC) after surgical intervention. Methods: During May 2003 to October 2010, 44 consecutive patients (26 male and 18 female) received curative lung RF ablation for 51 recurrent NSCLC (mean diameter 1.7 {+-} 0.9 cm, range 0.6 to 4.0) after surgical intervention. Safety, tumor progression rate, overall survival, and recurrence-free survival were evaluated. Prognostic factors were evaluated in multivariate analysis. Results: A total of 55 lung RF sessions were performed. Pneumothorax requiring pluerosclerosis (n = 2) and surgical suture (n = 1) were the only grade 3 or 4 adverse events (5.5%, 3 of 55). During mean follow-up of 28.6 {+-} 20.3 months (range 1 to 98), local tumor progression was found in 5 patients (11.4%, 5 of 44). The 1-, 3-, and 5-year overall survival rates were 97.7, 72.9, and 55.7%, respectively. The 1- and 3-year recurrence-free survival rates were 76.7 and 41.1%, respectively. Tumor size and sex were independent significant prognostic factors in multivariate analysis. The 5-year survival rates were 73.3% in 18 women and 60.5% in 38 patients who had small tumors measuring {<=}3 cm. Conclusion: Our results suggest that lung RF ablation is a safe and useful therapeutic option for obtaining long-term survival in treated patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗