AC-LGADs Fermilab front-end electronics characterization

Here, we characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the time resolution is influenced by the front-end electronics. To achieve this, we developed a setup capable of generating input signals with varying amplitudes. The output results demonstrated that signal processing by the front-end electronics plays a crucial role in enhancing time resolution. We showed that the time resolution achieved by the FEE board is better than 2 p s at the 1 σ level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward a DM Search with Phonon-Mediated MKID Devices at NEXUS

To continue the search for dark matter (DM) into the sub-GeV mass range, the development and characterization of new detectors with sub-eV thresholds is critical. Microwave Kinetic Inductance Detectors (MKIDs) offer an attractive architecture for novel microcalorimeters with the requisite energy resolution and threshold for probing DM down to the fermionic thermal relic mass limit of a few keV. A phonon-sensitive MKID device featuring an aluminum resonator patterned onto a silicon substrate has been operating at the NEXUS low-background facility at Fermilab for characterization and evaluation of its efficacy for a dark matter search. Currently, our estimate of the energy resolution of this device is limited by the efficiency for phonons produced via particle interactions in the substrate to propagate to the superconductor and break Cooper pairs. In this poster, I will present our constraints on the substrate-superconductor coupling and the progress on an absolute energy calibration performed by exposing the rear of the substrate to a pulsed source of 470 nm photons. I will also review the current status and next steps of the phonon-mediated MKID effort at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Black Hole Flares: Ejection of Accreted Magnetic Flux through 3D Plasmoid-mediated Reconnection

Magnetic reconnection can power bright, rapid flares originating from the inner magnetosphere of accreting black holes. We conduct extremely high-resolution (5376 × 2304 × 2304 cells) general-relativistic magnetohydrodynamics simulations, capturing plasmoid-mediated reconnection in a 3D magnetically arrested disk for the first time. We show that an equatorial, plasmoid-unstable current sheet forms in a transient, nonaxisymmetric, low-density magnetosphere within the inner few Schwarzschild radii. Magnetic flux bundles escape from the event horizon through reconnection at the universal plasmoid-mediated rate in this current sheet. The reconnection feeds on the highly magnetized plasma in the jets and heats the plasma that ends up trapped in flux bundles to temperatures proportional to the jet's magnetization. The escaped flux bundles can complete a full orbit as low-density hot spots, consistent with Sgr A* observations by the GRAVITY interferometer. Reconnection near the horizon produces sufficiently energetic plasma to explain flares from accreting black holes, such as the TeV emission observed from M87. The drop in the mass accretion rate during the flare and the resulting low-density magnetosphere make it easier for very-high-energy photons produced by reconnection-accelerated particles to escape. The extreme-resolution results in a converged plasmoid-mediated reconnection rate that directly determines the timescales and properties of the flare.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser-induced electron diffraction of the ultrafast umbrella motion in ammonia

Visualizing molecular transformations in real-time requires a structural retrieval method with Ångström spatial and femtosecond temporal atomic resolution. Imaging of hydrogen-containing molecules additionally requires an imaging method sensitive to the atomic positions of hydrogen nuclei, with most methods possessing relatively low sensitivity to hydrogen scattering. Laser-induced electron diffraction (LIED) is a table-top technique that can image ultrafast structural changes of gas-phase polyatomic molecules with sub-Ångström and femtosecond spatiotemporal resolution together with relatively high sensitivity to hydrogen scattering. Here, we image the umbrella motion of an isolated ammonia molecule (NH3) following its strong-field ionization. Upon ionization of a neutral ammonia molecule, the ammonia cation (NH3+) undergoes an ultrafast geometrical transformation from a pyramidal (ΦHNH=107°) to planar (ΦHNH=120°) structure in approximately 8 femtoseconds. Using LIED, we retrieve a near-planar (ΦHNH=117 ± 5°) field-dressed NH3+ molecular structure 7.8−9.8 femtoseconds after ionization. Our measured field-dressed NH3+ structure is in excellent agreement with our calculated equilibrium field-dressed structure using quantum chemical ab initio calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solution-phase sample-averaged single-particle spectroscopy of quantum emitters with femtosecond resolution

Here, the development of many optical quantum technologies depends on the availability of solid-state single quantum emitters with near-perfect optical coherence. However, a standing issue that limits systematic improvement is the significant sample heterogeneity and lack of mechanistic understanding of microscopic energy flow at the single emitter level and ultrafast timescales. Here we develop solution-phase single-particle pump-probe spectroscopy with photon correlation detection that captures sample-averaged dynamics in single molecules and/or defect states with unprecedented clarity at femtosecond resolution. We apply this technique to single quantum emitters in two-dimensional hexagonal boron nitride, which suffers from significant heterogeneity and low quantum efficiency. From millisecond to nanosecond timescales, the translation diffusion, metastable-state-related bunching shoulders, rotational dynamics, and antibunching features are disentangled by their distinct photon-correlation timescales, which collectively quantify the normalized two-photon emission quantum yield. Leveraging its femtosecond resolution, spectral selectivity and ultralow noise (two orders of magnitude improvement over solid-state methods), we visualize electron-phonon coupling in the time domain at the single defect level, and discover the acceleration of polaronic formation driven by multi-electron excitation. Corroborated with results from a theoretical polaron model, we show how this translates to sample-averaged photon fidelity characterization of cascaded emission efficiency and optical decoherence time. Our work provides a framework for ultrafast spectroscopy in single emitters, molecules, or defects prone to photoluminescence intermittency and heterogeneity, opening new avenues of extreme-scale characterization and synthetic improvements for quantum information applications.

36 MATERIALS SCIENCE↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Imaging Power Losses in CdSeTe Solar Cells

Much of the research on CdSeTe photovoltaics is focused on improving the open-circuit voltage (V oc ) of the solar cell. But solar cells operate at the maximum power point (MPP) rather than at V oc . The recombination processes at MPP may be different than those at V oc , and increasing the power output at MPP is the key to advancing efficiency. Here, we introduce a camera-based PL imaging system that enables power loss analysis under operating conditions and across cm-sized areas covering multiple cells. The instrument is demonstrated with CdSeTe devices having efficiencies greater than 19%. An implied current density versus implied voltage (iJV) curve can be produced at each pixel with <20 µm resolution. We find that regions with high implied open circuit voltage are often those with low implied fill factor, showing that voltage loss analysis at open circuit is not sufficient to understand power losses under operating conditions. Measurement of JV curves as a function of irradiance can also be performed in the system, which allows series resistance-free pseudo JV (pJV) curves to be produced. Comparison of pJV to measured JV and iJV curves allows further analysis of the operational losses, pointing the way to higher efficiency.

14 SOLAR ENERGY↗

High-Field Nuclear Magnetic Resonance (NMR) Spectroscopy

Nuclear magnetic resonance (NMR) is a non-destructive spectroscopic technique that provides detailed molecular structural information via the electronic environments of nuclei in materials. Higher magnetic field strengths enhance the resolution of NMR, enabling discernment of unique chemical environments that might not be possible at low fields. Herein, the application of high-field NMR to catalyst and electrochemical system characterization are detailed. A brief description of NMR and quadrupolar nuclei are presented where the effects of magnetic field are described. Examples of high-field NMR are provided with particular focus on employing NMR to elucidate the structure of oxides of aluminum and vanadium for catalyst applications. The role of high-field NMR to conduct challenging experiments for energy storage materials is also explored and numerous other nuclei which require high-field measurement are briefly summarized.

Catalyst, Spectroscopy, NMR, High-field, Quadrupol↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

Implications of high-pressure oxygen hydrates on radiolytic oxygen in Jovian icy moons

Various icy moons, such as Europa and Ganymede, have thin oxygen atmospheres and exhibit spectral features attributed to oxygen held in their surface ices. The oxygen forms from the radiolysis of water. The interiors of these bodies are subject to high pressures and it is not known how deep into icy moons oxygen-bearing ices can penetrate, or the structures formed by the oxygen–water system at high pressure. Here, we show that oxygen hydrates are stable to 2.6 GPa, allowing them to penetrate deep into icy moons, both above and below proposed sub-surface liquid-water oceans. Similarities between oxygen and hydrogen hydrates indicate potentially enhanced recombination rates, transforming them back into water and offering a resolution to the discrepancy between predicted and measured radiolysis rates. In addition to the low-pressure CS-II clathrate, our results find three high-pressure phases in the oxygen–water system: an ST clathrate, a C 0 hydrate, and a filled ice isomorphous with methane hydrate III. This shows a vast storage potential for molecular oxygen in icy moons and indicates that Europa could still be absorbing oxygen into its crustal ice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-photoelectron collection efficiency in 4D ultrafast electron microscopy

In femtosecond (fs) 4D ultrafast electron microscopy (UEM), a tradeoff is made between photoelectrons per packet and time resolution. One consequence of this can be longer-than-desirable acquisition times for low-density packets, and particularly for low repetition rates when complete photothermal dissipation is required. Thus, gaining an understanding of photoelectron trajectories in the gun region is important for identifying factors that limit collection efficiency (CE; fraction of photoelectrons that enter the illumination system). Here, we continue our work on the systematic study of photoelectron trajectories in the gun region of a Thermo Fisher/FEI Tecnai Femto UEM, focusing specifically on CE in the single-electron regime. Using General Particle Tracer, calculated field maps, and the exact architecture of the Tecnai Femto UEM, we simulated the effects of fs laser parameters and key gun elements on CE. The results indicate CE strongly depends upon the laser spot size on the source, the (unbiased) Wehnelt aperture diameter, and the incident photon energy. The CE dispersion with laser spot size is found to be strongly dependent on aperture diameter, being nearly dispersionless for the largest apertures. A gun crossover is also observed, with the beam-waist position being dependent on the aperture diameter, further illustrating that the Wehnelt aperture acts as a simple, fixed electrostatic lens in UEM mode. This work provides further insights into the operational aspects of fs 4D UEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge exchange recombination spectroscopy measurements of DIII-D poloidal rotation with poloidal asymmetry in angular rotation

Sixteen new tangential views for the charge exchange recombination (CER) spectroscopy diagnostic at DIII-D were installed in 2019 on the high-field side (HFS) of the tokamak with the main goal being the measurement of main-ion (deuterium) poloidal rotation. Eight of the new views are connected to spectrometers, which view the main-ion spectrum, adding main-ion measurements where there were previously none, and another eight new views increased the spatial resolution of existing impurity (carbon) measurements on the HFS. When combined with the existing low-field side measurements, measurements at two locations on flux surfaces out to a normalized minor radius of ≈0.6 are possible. The new tangential views have been used to measure the deuterium poloidal rotation directly for the first time using the Poloidal Asymmetry in Angular Rotation (PAAR) method. Furthermore, these new measurements enable further testing of the validity of neoclassical poloidal rotation predictions. Separate measurements of the radial electric field can be made for an impurity ion and the main-ion by combining the PAAR measurements with additional CER measurements of toroidal rotation, temperature, and density. These independent measurements of the radial electric field agree reasonably well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft phonon and the central peak at the cubic-to-tetragonal phase transition in SrTiO 3

The continuous displacive phase transition in SrTiO 3 near 𝑇 𝑐 ≈105 K features a central elastic peak in neutron-scattering investigations at temperatures above 𝑇 𝑐 , i.e., before the corresponding soft phonon mode is overdamped upon cooling. The origin of this central peak is still not understood. Here, in this work, we report an inelastic x-ray scattering investigation of the cubic-to-tetragonal phase transition in SrTiO 3 . We compare quantitatively measurements of the soft phonon mode on two differently grown samples and discuss the findings regarding results from thermodynamic and transport probes such as specific heat and thermal conductivity. Furthermore, we use inelastic x-ray scattering to perform elastic scans with both high momentum and milli-electronvolt energy-resolution and, thus, are able to separate elastic intensities of the central peak from low-energy quasielastic phonon scattering. Our results indicate that the evolution of the soft mode is similar in both samples though the intensities of the central peak differ by a factor of four. Measurements revealing anisotropic correlation lengths on cooling towards 𝑇 𝑐 , indicate that local properties of the crystals to which collective lattice excitations are insensitive are likely at the origin of the central elastic line in SrTiO 3 .

anharmonic lattice dynamics↗

Smart Readout of Nondestructive Image Sensors with Single Photon-Electron Sensitivity

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest in the array, or dynamically, depending on the charge or energy of interest in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep subelectron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as electron multiplier charge coupled devices, silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Performance/-Precision/-Z(HPPZ) Scintillator Grids via Advanced Electrochemistry. Phase I – Project # 20210572MFR- Mid year review [Slides]

Scintillation grids with improved imaging resolution in time and space, are required for future mission needs at various facilities (pRad user station, LANSCE, DARHT, Scorpius etc). Current technologies use inorganic crystal scintillators, which are positioned within a high-Z scintillator septa. Dense and high-Z materials are optimal for gamma-ray detection making them promising candidates for development of high -performance/-precision/-Z (HPPZ) scintillator grids. The current resolution of standard chemical etching and fabrication processes of high-Z materials is very low, leading to undesired undercutting and ultimately reducing crystal performance efficiency. Goals are to: Perform initial feasibility studies with the aim of producing complex parts for applications with difficult-to-process high-Z material; Use of pulse and pulse-reverse electrochemical methods on additive approaches to produce high-precision Au and Re scintillator grids at a small scale; and, Follow up in Phase II with the delivery of a large-scale scintillator grid of the best material candidate with unprecedented properties for LANL needs determined in Phase I.

36 MATERIALS SCIENCE↗

Cryogenic Platforms at Fermilab: Recent Results and Outlook

The Cosmic Quantum group at Fermilab operates three cryogenic facilities dedicated to the development and calibration of superconducting low-threshold detectors and qubits. One of which (LOUD) is located at the surface, while the other two (NEXUS and QUIET) are located 100 m underground enabling low-background device characterization and rare event searches. Recently, we have demonstrated world-leading resolution in the quasiparticle channel for kinetic inductance phonon-mediated detectors as well as the lowest rate of spatially- and temporally- correlated errors ( charge jumps ) in superconducting qubit chips. We have additionally made significant progress in expanding the suite of tools for simulating signal production and readout of these devices. In this talk, I will review these recent results, discuss some nascent projects focused on enhancing sensitivity of these detectors to sub-GeV dark matter, and highlight activities in these facilities over the next year.

Temples, Dylan J.↗

Analysis of Deformation Mechanisms, Strain Localization, and Fracture in Highly Irradiated Austenitic Steels – Light-Water Reactor Core Materials – via Advanced inSEM Techniques

The present report describes the establishing of an advanced experimental approach – high-resolution digital image correlation or µDIC – for testing miniature irradiated specimens in the ORNL’s Low Activation Materials Development and Analysis (LAMDA) facility. As expected, the µDIC approach will allow for studying strain localization inside grains, for instance, during dislocation channel-grain boundary interaction processes. This information is of high importance for understanding degradation processes in irradiated austenitic steels – in-core materials of Light Water Reactors. The Level 4 report provides a brief introduction, lists materials designated for µDIC testing and delivered in LAMDA this FY, discusses methodical concerns and preliminary observations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗