Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LUNGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Advancing Translational Space Research Through Biospecimen Sharing: Amplified Impact of Studies Utilizing Analogue Space Platforms

Biospecimen Sharing Programs (BSPs) have been organized by NASA Ames Research Center since the 1960s with the goal of maximizing utilization and scientific return from rare, complex and costly spaceflight experiments. BSPs involve acquiring otherwise unused biological specimens from primary space research experiments for distribution to secondary experiments. Here we describe a collaboration leveraging Ames expertise in biospecimen sharing to magnify the scientific impact of research informing astronaut health funded by the NASA Human Research Program (HRP) Human Health Countermeasures (HHC) Element. The concept expands biospecimen sharing to one-off ground-based studies utilizing analogue space platforms (e.g., Hindlimb Unloading (HLU), Artificial Gravity) for rodent experiments, thereby significantly broadening the range of research opportunities with translational relevance for protecting human health in space and on Earth. In this presentation, we will report on biospecimens currently being acquired from HHC Award Head-Down Tilt as a Model for Intracranial and Intraocular Pressures, and Retinal Changes during Spaceflight, and their availability. The BSP add-on to the project described herein has already yielded for HHC-funded investigators more than 4,700 additional tissues that would otherwise have been discarded as waste, with additional tissues available for analysis. Young (3-mo old) male and female rats and Older (9-mo old) male rats are being exposed to HLU for either 7, 14, 28, or 90 days. Additional groups are exposed to 90 days of unloading followed by either 7, 14, 28 days or 90 days of recovery (normal loading). Comparisons are made with non-suspended controls. Unused tissues are: Skin, Lungs, Thymus, Adrenals, Kidneys, Spleen, Hindlimb Muscles (Soleus, Extensor Digitorum Longus, Tibialis Anterior, Plantaris Gastrocnemius), Fat Pads, Reproductive Organs, and Intestines. Tissues are harvested, weighed, preserved then archived (with metadata) using a sample tracking system (CryoTrack). Preservation techniques include snap-freezing and RNALatersnap-freezing. Specimens were weighed at the time of dissection, and organ mass:body mass ratios analyzed to determine unloading effects across conditions and durations. The results corroborate previously reported effects of short-term exposure to microgravity or unloading exposure on various organs, and provide new insights into adaptation to long-duration unloading relevant to sustained spaceflight exposures on ISS.

biospecimen sharing↗

Preparing for Planetary Surface Exploration by Measuring Habitat Dust Intrusion with Filter Tests During an Analogue Mars Mission

As humans venture deeper into space more issues related to operations will become apparent. While the perils ofdust particles may not be widely recognized, it is one of the major issues astronauts will face on the surface of theMoon and Mars. Dust particles present a problem for both astronaut health and equipment as revealed during theApollo era lunar surface missions. Dust particles cling to spacesuits and field gear, which upon ingress would begincirculating throughout the spacecraft or habitat. An astronaut's health is compromised by the dust particle's potentialto embed in the lungs and cause respiratory illnesses. The extreme abrasiveness and granularity of the particles makeit near impossible to completely shield a spacecraft or habitat from dust related damage. NASA's Glenn ResearchCenter collaborated with Crew 188 at the Mars Desert Research Station (MDRS) in Utah to measure how much dustentered the habitat during a series of extravehicular activities (EVAs), or surface excursions. A NASA GRCdeveloped multistage filter system, coined the Scroll Filter System, was tested, for its effectiveness in removing dustthat entered the airlock and habitat after the EVAs. An optical particle counter measured the ambient airlockparticulates five times including: before the start of operations; after the crew left for EVA; in the middle of the EVAwith the settled air; before the crew entered the airlock after EVA; and finally, after the crew simulated repressurizationand suit brushing off in the airlock. Data was also collected in several of the working environmentlocations around MDRS and outside the habitat in the wind. Data collected from this research will help establishfilter equipment for life support systems and prescribed operations for astronaut transition from a planetary surfaceinto a desired clean habitat. Measurements may aid in updating a baseline expected dust load for a surface habitatand further facilitate the mitigation of astronaut's exposure to dust particles on the surface of celestial bodies.

Kobrick, Ryan L.↗

Developing an Air Quality Index for Space Vehicles and Habitats

The development of an adequate tool to help the layperson understand pollution levels in their environment is of high importance. This tool must be able to inform about the levels of pollution in a simple and understandable way but also can be used for decision-making and mitigation activities to protect the health of the exposed population. One of the most useful and up-to-date approaches for characterizing air pollution is the Air Quality Index (AQI). It is an easily-calculated, powerful, data-driven tool that summarizes a complex phenomenon, such as air pollution, in straightforward indicators. The AQI system has been developed in different countries around the world, mainly for outdoor environments, based on the results of risk assessments, epidemiological studies, and current local air pollution regulations and standards. There is a need for such a system in low gravity indoor environments where air quality is of fundamental importance to astronaut health, with concerns encompassing both gaseous contaminants and particulate matter. Earth-based AQIs cannot be extrapolated to microgravity indoor environments due to different aerosol transport characteristics and altered lung deposition in low and partial gravity. The objectives of this work are to explore what areas of expertise, types of research, and data will be required to formulate a spacecraft-specific AQI. An initial dataset is available for this effort, combined from two aerosol sampling experiments, which have characterized airborne particulate matter on the International Space Station (ISS). We outline future research needs for formulating a narrowly focused version of a widely-used metric, namely, an indoor AQI for future space missions.

Sorek-Hamer, Meytar↗

Developing an Air Quality Index for Microgravity Indoor Environments/Space Missions

Indoor pollution sources (on Earth) that release gases or particles into the air are the primary cause of air quality problems in indoor environments. The development of an adequate tool to understand pollution levels in a certain location is of high importance. This tool must be able to inform about the levels of pollution in a simple and understandable way but also, used to take a series of predetermined measures to protect the health of the exposed population. One of the most useful and up to date approaches for characterizing air pollution is the Air Quality Index (AQI). It is an easily-calculated powerful data-driven tool, that summarizes a complex phenomenon, such as air pollution, in straightforward indicators. The AQI system has been developed in different countries around the world, mainly for outdoor environments, based on the results of risk assessments, epidemiology studies, and current local air pollution regulations and standards.Air quality in microgravity indoor environments is of fundamental importance to crew health, with concerns encompassing both gaseous contaminants and particulate matter. Although the concentration of gases in the microgravity indoor environment is well studied, aerosols remain one of the major pollutants that affect air quality and has reported adverse health effects and hasn't been reported under these unique conditions. Earth-based AQIs can't be extrapolated to microgravity indoor environments due to different aerosol characteristics and altered lung deposition in low gravity.Concurrent with the aerosol-focused AQI effort, we assess and document how the process would apply for combining particles & gases into a composite index, with the ability to query each AQI independently. All this information can be combined in a spacecraft-specific AQI for future space missions and habitats. The objective of this work are to determine what areas of expertise will contribute, what research and data will be required, and explore the scope of effort needed to formulate a spacecraft AQI in addition to analyzing ISS aerosol sampling data and incorporate results from both aerosol Sampling experiments (the only relevant data available from space).

Sorek-Hamer, Meytar↗

Medics: Medical Decision Support System for Long-Duration Space Exploration

The Autonomous Medical Operations (AMO) group at NASA Ames is developing a “medical decision support system” to enable astronauts on long-duration exploration missions to operate autonomously. The system will support clinical actions by providing medical interpretation advice and procedural recommendations during emergent care and clinical work performed by crew. The current state of development of the system, called MedICS (Medical Interpretation Classification and Segmentation) includes two separate aspects: a set of machine learning diagnostic models trained to analyze organ images and patient health records, and an interface to ultrasound diagnostic hardware and to medical repositories. Three sets of images of different organs and medical records were utilized for training machine learning models for various analyses, as follows: 1. Pneumothorax condition (collapsed lung). The trained model provides a positive or negative diagnosis of the condition. 2. Carotid artery occlusion. The trained model produces a diagnosis of 5 different occlusion levels (including “normal”). 3. Ocular retinal images. The model extracts optic disc pixels (image segmentation). This is a precursor step for advanced autonomous fundus clinical evaluation algorithms to be implemented in FY20. 4. Medical health records. The model produces a differential diagnosis for any particular individual, based on symptoms and other health and demographic information. A probability is calculated for each of 25 most common conditions. The same model provides the likelihood of survival. All results are provided with a confidence level. Item 1 images were provided by the US Army and were part of a data set for the clinical treatment of injured battlefield soldiers. This condition is relevant to possible space mishaps, due to pressure management issues. Item 2 images were provided by Houston Methodist Hospital, and item 3 health records were acquired from the MIT laboratory of computational physiology. The machine learning technology utilized is deep multilayer networks (Deep Learning), and new models will continue to be produced, as relevant data is made available and specific health needs of astronaut crews are identified. The interfacing aspects of the system include a GUI for running the different models, and retrieving and storing data, as well as support for integration with an augmented reality (AR) system deployed at JSC by Tietronix Software Inc. (HoloLens). The AR system provides guidance for the placement of an ultrasound transducer that captures images to be sent to the MedICS system for diagnosis. The image captured and the associated diagnosis appear in the technician’s AR visual display.

Colombano, Silvano↗

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗

Patch Plate Materials Compatibility Assessment

Lunar dust proved to be a greater problem during the Apollo missions than was originally anticipated. The highly angular, charged dust particles stuck to seals, radiators, and visors; clogged mechanisms; and abraded space suits. As reported by Apollo 12 astronaut Pete Conrad "We must have had more than a hundred hours suited work with the same equipment, and the wear was not as bad on the training suits as it is on these flight suits in just the eight hours we were out.". Dust clinging to surfaces was also transport-ed into habitable spaces leading to lung and eye irritation of the astronauts. The Apollo astronauts were on the Lunar surface less than 24 hours and experienced many dust related problems. With the Artemis program, we are planning longer stays on the surface, with more activities that have the potential to put the astronauts and equipment in contact with greater quantities of Lunar dust. The success of these missions will depend on our understanding of material interactions with Lunar dust and the development of ways to mitigate dust effects in cases where exposure to dust will lead to failure of components, unacceptable loss of power or thermal control, unacceptable loss of visibility, or health issues. Through the Lunar Surface In-novation Initiative (LSII), we are initiating a Patch Plate Materials Compatibility Assessment project. The overall goal of the three year project is to develop passive approaches to mitigate Lunar dust adhesion to surfaces for technologies that are currently at TRL levels 2-3 to bring them to TRL level 5 through ground-based assessment, culminating in a demonstration flight experiment on a Commercial Lunar Payload Services (CLPS) lander in 2022-2023. This paper discusses the detailed technical objectives and approach for this project. References: Gaier, J.R. "The Effects of Lunar Dust on EVA Systems During the Apollo Missions," NASA/TM-2005-213610/REV1, (2005), Apollo 12 Technical Crew Debriefing, December 1, 1969, pp. 10-54.

Miller, S. K. R.↗

Minipigs as a Model to Study Separate and Combined Effects of Space Radiation and Altered Gravity on Cardiovascular disease, Spaceflight-Associated Neuro-Ocular Syndrome (SANS), and Central Nervous System (CNS) effects

Minipigs are a well-characterized animal model used to study thecardiovascular system, metabolism, bone, gastrointestinal tract,pancreas, liver, kidney, lung, immune system, central nervous system(white matter) etc. Due to their anatomical, physiological, andbiochemical similarities to humans, minipigs are considered atranslational model in biomedical research and development. Also, their large size and cognitive abilities allow collection of supplementary information regarding the central nervous system(BMed) and Spaceflight-Associated Neuro-Ocular Syndrome (SANS) risk.

Janapriya Saha↗

Machine Intelligence for Radiation Science: Summary of the Radiation Research Society 67th Annual Meeting Symposium

The era of high-throughput techniques created big data in the medical field and research disciplines. Machine intelligence (MI) approaches can overcome critical limitations on how those large-scale data sets are processed, analyzed, and interpreted. The 67 th Annual Meeting of the Radiation Research Society featured a symposium on MI approaches to highlight recent advancements in the radiation sciences and their clinical applications. This article summarizes three of those presentations regarding recent developments for metadata processing and ontological formalization, data mining for radiation outcomes in pediatric oncology, and imaging in lung cancer.

radiation↗

Global Premature Mortality By Dust and Pollution PM 2.5 Estimated From Aerosol Reanalysis of the Modern-Era Retrospective Analysis for Research and Applications, Version 2

This study quantifies global premature deaths attributable to long-term exposure of ambient PM 2.5 , or PM 2.5 -attributable mortality, by dust and pollution sources. We used NASA’s Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA-2) aerosol reanalysis product for PM 2.5 and the cause-specific relative risk (RR) from the integrated exposure-response (IER) model to estimate global PM2.5-attributable mortality for five causes of deaths, namely ischaemic heart disease (IHD), cerebrovascular disease (CEV) or stroke, lung cancer (LC), chronic obstructive pulmonary disease (COPD), and acute lower respiratory infection (ALRI). The estimated yearly global PM 2.5 -attributable mortality in 2019 amounts to 2.89 (1.38–4.48) millions, which is composed of 1.19 (0.73–1.84) million from IHD, 1.01 (0.35–1.55) million from CEV, 0.29 (0.11–0.48) million from COPD, 0.23 (0.14–0.33) million from ALRI, and 0.17 (0.04–0.28) million from LC (the numbers in parentheses represent the estimated mortality range due corresponding to RR spread at the 95% confidence interval). The mortality counts vary with geopolitical regions substantially, with the highest number of deaths occurring in Asia. China and India account for 40% and 23% of the global PM 2.5 -attributable deaths, respectively. In terms of sources of PM 2.5 , about 22% of the global all-cause PM 2.5 -attributable deaths are caused by desert dust. The largest dust attribution is 37% for ALRI. The relative contributions of dust and pollution sources vary with the causes of deaths and geographical regions. Enforcing air pollution regulations to transfer areas from PM 2.5 nonattainment to PM2.5 attainment can have great health benefits. Being attainable with the United States air quality standard (AQS) of 15 μg/m 3 globally would have avoided nearly 40% or 1.2 million premature deaths. The most recent update of PM 2.5 guideline from 10 to 5 μg/m 3 by the World Health Organization (WHO) would potentially save additional one million lives. Our study highlights the importance of distinguishing aerodynamic size from geometric size in accurately assessing the global health burden of PM 2.5 and particularly for dust. A use of geometric size in diagnosing dust PM 2.5 from the model simulation, a common approach in current health burden assessment, could overestimate the PM 2.5 level in the dust belt by 40–170%, leading to an overestimate of global all-cause mortality by 1 million or 32%.

PM2.5↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Evaluation of Aerosol Data Assimilation and Forecasts in the NASA GEOS Model during the ASIA-AQ Campaign

Fine particulate matter (PM2.5) poses significant risks to human health and the environment by penetrating the lungs and causing respiratory and cardiovascular diseases, making it crucial to understand its sources and behavior for effective air quality management. The Goddard Earth Observing System (GEOS) Forward Processing (FP) system model, operated by the Global Modeling and Assimilation Office (GMAO) at NASA's Goddard Space Flight Center, provides real-time weather and aerosol analyses and forecasts. In addition to meteorological data assimilation, the GEOS-FP system also assimilates aerosol using Moderate Resolution Imaging Spectroradiometer (MODIS) Aerosol Optical Depth (AOD) and Aerosol Robotic Network (AERONET) AOD data. In this study, the aerosol data assimilation and forecasts performance of the GEOS-FP model were evaluated for predicting PM2.5 in Korea using observations from the Airborne and Satellite Investigation of Asian Air Quality (ASIA-AQ) campaign. The ASIA-AQ campaign, an international collaborative field study initiative, aims to enhance understanding of local air quality issues and address common challenges in interpreting satellite data and air quality modeling. Conducted in South Korea from February 15 to March 13, 2024, during the high PM2.5 concentration winter season, this campaign provided extensive airborne and ground observations for intensive analysis of PM2.5 model simulations. We demonstrate how the assimilation runs and the forecasting performance of PM2.5 at 24-hour and 48-hour intervals vary. Additionally, we analyzed the differences and characteristics of PM2.5 composition in cases of long-range transport and local emissions. Using ASIA-AQ airborne data, we also examined the vertical profile of fine particulate matter. Through the intensive observations of this campaign, the GEOS model was assessed over South Korea using both in situ and airborne measurements to establish a baseline and identify priorities for future development.

Seunghee Lee↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

Potential Health Impacts, Treatments, and Countermeasures of Martian Dust on Future Human Space Exploration

The challenges of human space exploration produce some of humanity’s greatest technological and scientific advances, not excluding innovations in medicine. The microgravity environment causes a whole host of physiological changes, and exposure to dust on the Moon caused considerable pulmonary distress to astronauts during the Apollo missions. As the National Aeronautics and Space Administration (NASA)and other space organizations prepare for long duration exploration missions to Mars, the hazards and consequences of the Martian surface need to be accounted for. This review investigates how substances analogous to the hazardous components of Martian dust have caused disease in people on Earth. Because of the small grain size of Martian dust, dust on Mars is more likely to cause lung irritation, absorb into the bloodstream, and lead to diseases in astronauts. Toxic components of Martian dust to astronaut health include perchlorates, silica, nanophase iron oxides, and gypsum in addition to trace amounts of toxic metals whose abundances are debated: chromium, beryllium, arsenic, and cadmium. Predicted effects of dust exposure ranges from asymptomatic to life threatening, with many substances being carcinogenic and most damage impacting the pulmonary system. The longer transit time for astronauts to return home makes the operations of performing emergency medical treatment more difficult and increases both the likelihood and consequences of developing chronic disease. Exposure mitigation needs to be prioritized; however, supplements may be taken to prevent disease from breakthrough exposures and treatment regimens could lessen morbidity and mortality. Treatments and equipment need to be carefully thought out and transported with the astronauts to be prepared for all possible scenarios.

Justin L Wang↗

Bi-terminal pegylated integrin-binding peptides and methods of use thereof

The present invention provides bi-terminal PEGylated peptide conjugates that target an integrin such as αvβ6 integrin. In particular embodiments, the peptide conjugates of the present invention further comprise a biological agent such as an imaging agent or a therapeutic agent, e.g., covalently attached to one of the PEG moieties. The peptide conjugates of the present invention are particularly useful for imaging a tumor, organ, or tissue and for treating integrin-mediated diseases and disorders such as cancer, inflammatory diseases, autoimmune diseases, chronic fibrosis, chronic obstructive pulmonary disease (COPD), lung emphysema, and chronic wounding skin disease. Compositions and kits containing the peptide conjugates of the present invention find utility in a wide range of applications including, e.g., in vivo imaging and immunotherapy.

Hausner, Sven H.↗

Chapter 22 - Chlorine. In: “Handbook of Toxicology of Chemical Warfare Agents, Third Edition”, Editor: Ramesh C. Gupta.

Chlorine gas is used widely by industry and as a disinfectant and bleach, and, due to its toxicity and ease of procurement, has been used as a chemical warfare agent. Chlorine is a strong oxidizer that hydrolyzes in water to form hydrochloric and hypochlorous acid. Upon chlorine inhalation, the respiratory tract is the predominant target organ in humans and animals as chlorine is a contact irritant. Exposure causes sensory irritation and pulmonary dysfunction, and at sufficiently high concentrations results in lung lesions and injury to other internal organs including the heart. Human and animal studies have shown that chlorine toxicity is influenced more by exposure concentration than duration, is gender-independent, and increases with age, cigarette smoking, and preexisting respiratory conditions such as asthma and airway hyperreactivity. Treatment is largely supportive, although animal studies are examining the utility of various compounds for chlorine-specific treatment based on its mechanism of action.

Milanez, Sylvia↗

Acute shortage ventilator

We have implemented an ″Acute Shortage Ventilator″ (ASV) motivated by the COVID-19 pandemic and the possibility of severe ventilator shortages in the near future. The unit cost per ventilator is less than $400 US excluding the patient circuit parts. The ASV mechanically compresses a self-inflating bag resuscitator, uses a modified patient circuit, and is commanded by a microcontroller and an optional laptop. It operates in both Volume-Controlled Assist-Control mode and a Pressure-Controlled Assist-Control mode. It has been tested using an artificial lung against the EURS guidelines. The key design goals were to develop a simple device with high performance for short-term use, made primarily from common hospital parts and generally-available non-medical components, and at low cost and ease in manufacturing.

Breur, Sander↗

Bi-terminal pegylated integrin-binding peptides and methods of use thereof

The present invention provides bi-terminal PEGylated peptide conjugates that target an integrin such as αvβ6 integrin. In particular embodiments, the peptide conjugates of the present invention further comprise a biological agent such as an imaging agent or a therapeutic agent, e.g., covalently attached to one of the PEG moieties. The peptide conjugates of the present invention are particularly useful for imaging a tumor, organ, or tissue and for treating integrin-mediated diseases and disorders such as cancer, inflammatory diseases, autoimmune diseases, chronic fibrosis, chronic obstructive pulmonary disease (COPD), lung emphysema, and chronic wounding skin disease. Compositions and kits containing the peptide conjugates of the present invention find utility in a wide range of applications including, e.g., in vivo imaging and immunotherapy.

Hausner, Sven H.↗