Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Structure and dynamics of coronal plasmas

The Normal Incidence X-ray Telescope (NIXT) obtained a unique set of high resolution full disk solar images which were exposed simultaneously by X-rays in a passband at 63.5 A and by visible light. The perfect alignment of a photospheric visible light image with a coronal X-ray image enables us to present observations of X-ray intensity vs an accurately determined height above the visible limb. The height at which the observed X-ray intensity peak varies from 4000 km in active regions to 9000 km in quiet regions of the sun. The interpretation of the observations stems from the previously established fact that, for the coronal loops, emission in the NIXT bandpass peaks sharply just above the footpoints. Because there is not a sharp peak in the observed X-ray intensity vs off limb height, we conclude that the loop footpoints, when viewed at the limb, are obscured by absorption in chromospheric material along the line of sight. We calculate the X-ray intensity vs height predicted by a number of different idealizations of the solar atmosphere, and we compare these calculations with the observed X-ray intensity vs height. The calculations use existing coronal and chromospheric models. In order for the calculations to reproduce the observed off limb X-ray intensities, we are forced to assume an atmosphere in which the footpoints of coronal loops are interspersed along the line of sight with cooler chromospheric material extending to heights well above the loop footpoints. We argue that the absorption coefficient for NIXT X-rays by chromospheric material is roughly proportional to the neutral hydrogen density, and we estimate an average neutral hydrogen density and scale height implied by the data.

Golub, Leon↗

Translimb Spectroscopy with SOHO/SUMER

We have used SUMER to obtain deep exposures of the 1300-1400 A spectrum, at the extreme limb and off-limb. Previous "translimb" studies in the thermal infrared had revealed remarkable extensions of cold material (T approximately 3000 K)--traced by carbon monoxide emission lines--into the heart of the hot chromosphere. A main objective of our program was to search for corresponding far-UV signatures of the "thermally-bifurcated" low chromosphere; for example, radiatively fluoresced emissions of the CO A-X 4th-positive system (collisional excitation would be negligible in cold gas). We conducted two separate observing programs with SUMER. Both made use of the 1"-diameter circular aperture, translated across the limb in the minimum motor step increments of 0.375", along the central meridian in the Northern polar coronal hole. The first program executed for nine hours beginning 19UT 25 Oct 1996. The full wavelength range was 1340-1400 A. It was recorded in two overlapping segments, placing key regions of the spectrum alternately on the KBr and bare parts of the detector, to help isolate 2nd-order features. Each segment was integrated for 500 s, and 32 pairs were obtained to span a 12" swath centered on the optical limb. The second program was conducted 00-09UT 01 Dec 1996. It consisted of a single wavelength setting (1300-1340 A) with exposure time 500 s, but twice the spatial coverage of the earlier series: 64 steps, for a total displacement of 24". The strong chromospheric resonance lines of atomic oxygen (1302-1305 A) and ionized carbon (1334-1335 A) were observed on the bare part of the MCP camera. We report our progress in cataloging the rich, diverse translimb emission spectrum; and our efforts to deduce fundamental properties of the thermally heterogeneous chromosphere.

Ayer, Thomas R.↗

The EOS-CHEM Mission

The EOS-CHEM Mission is currently scheduled for launch in late 2002. The payload consists of four instruments: a microwave limb sounder, MLS, an infrared limb sounder, HIRDLS, an infrared nadir and limb Fourier transform spectrometer, TES, and a UV backscatter sounder, OMI, The science objectives of the CHEM mission will be discussed as well as the observing strategies. The limb instruments are designed to make near coincidental measurements of the same air mass thus providing a nearly complete assessment of key stratospheric trace gases. The nadir instruments will provide the first global measurements of tropospheric ozone and the tropospheric ozone residual.

Schoeberl, Mark↗

Long-term Global Morphology of Gravity Wave Activity Using UARS Data

An extensive body of research this quarter is documented. Further methodical analysis of temperature residuals in Cryogenic Limb Array Etalon Spectrometer (CLAES) Version 8 level 3AT data show signatures during December 1992 at middle and high northern latitudes that, when compared to Naval Research Laboratory/Mountain Wave Forecast Model (NRL)/(MWFM) mountain wave hindcasts, reveal evidence of long mountain waves in these data over Eurasia, Greenland, Scandinavia and North America. The explicit detection of gravity waves in limb-scanned Cryogenic Infrared Spectrometers and Telescopes for the Atmosphere (CRISTA) temperatures is modeled at length, to derive visibility functions. These insights are used to convert CRISTA gravity wave temperature residuals into data that more closely resemble gravity wave fluctuations detected in data from other satellite instruments, such as Microwave Limb Sounder (MLS), Limb Infrared Monitor of the Stratosphere (LIMS) and Global Positioning System/Meteorology (GPS)/(MET). Finally, newly issued mesospheric temperatures from inversion of CRISTA 15gin emissions are analyzed using a new method that uses separate Kalman fits to the ascending and descending node data. This allows us to study global gravity wave amplitudes at two local times, 12 hours apart. In the equatorial mesosphere, where a large diurnal tidal temperature signal exists, we see modulations of gravity wave activity that are consistent with gravity wave-tidal interactions produced by tidal temperature variability.

Eckermann, Stephen D.↗

Obstructive apnea during sleep is associated with peripheral vasoconstriction

Obstructive apnea during sleep is associated with a substantial transient blood pressure elevation. The mechanism of this pressor response is unclear. In this study we measured muscle sympathetic nerve activity (MSNA), mean arterial pressure (Psa), and mean limb blood velocity as an index of blood flow (MBV, Doppler) and calculated changes in limb vascular resistance during and after apneas during both wakefulness and sleep in patients with the obstructive sleep apnea syndrome. Immediately postapnea during sleep Psa increased significantly compared with the earlier stages of apnea and this was preceded by a rise of MSNA (n = 5). In contrast to blood pressure, MBV remained unchanged. Because resistance = blood pressure/blood flow, limb vascular resistance increased by 29 +/- 8% from late apnea to postapnea (n = 7, p < 0.002). Voluntary breathhold maneuvers during room air exposure evoked similar responses (n = 10). Supplemental oxygen administered via nonrebreather face mask attenuated the MSNA and vasoconstrictor responses to obstructive (n = 2) and voluntary apneas (n = 10). Our data suggest that obstructive apneas in patients with the obstructive apnea syndrome are accompanied by transient limb vasoconstriction. This vasoconstrictor response appears to be, at least in part, mediated by the sympathetic nervous system and may be linked to hypoxia.

NASA Discipline Cardiopulmonary↗

High Salt Intake Promotes Urinary Loss of Vitamin D Metabolites by Dahl Salt-Sensitive Rats in a Space Flight Model

Vitamin D metabolism in the Dahl salt-sensitive (S) rat, a model of salt-induced hypertension, differs from that in the Dahl salt-resistant (R) rat. We have demonstrated that female S rats are more vulnerable than female R rats to decreases in plasma 25-hydroxyvitamin D (25-OHD) and 1,25-dihydroxyvitamin D (1,25-(OH)2D) concentrations during hind limb unloading (a space flight model). We report here on the response of the vitamin D endocrine system of S and R rats to hind limb unloading during high salt intake. Dahl female rats (9.7-week-old) were tail-suspended (hind limb unloaded) for 28 days, while fed a diet containing twice the salt in standard rat chow (2 % sodium chloride). Control rats were fed the same diet, but were not hind limb unloaded. Vitamin D metabolites were analyzed by HPLC and radioimmunoassay kits from Diasorin.

Thierry-Palmer, M.↗

Wide and Narrow CMEs and Their Source Explosions Observed at the Spring 2003 SOHO-Sun-Ulysses Quadrature

At the time of the spring 2003 Ulysses-SOHO-Sun quadrature, Ulysses was off the East limb of the Sun at 14.5 degrees north latitude and 4.91 AU. LASCO/C2 images show small transient events that originated from near the limb on May 25, 26 and 27 in the north-east quadrant, along with a large Coronal Mass Ejection (CME) that originated from an active region near disk center on May 26. Ulysses data bear clear signatures of the large CME, specifically including an enhanced abundance of highly ionized Fe. SOHO/UVCS spectra at 1.75 solar radii, near the radial direction to Ulysses, give no evidence of emission from high temperature lines, even for the large CME: instead, for the small events, occasional transient high emission in cool lines was observed, such as the CIII 977 Angstrom line usually absent at coronal levels. Each of these events lasted ca. 1 hour or less and never affected lines from ions forming above ca. 106K. Compact eruptions in Helium 304 Angstrom EIT images, related to the small UVCS transients, were observed at the limb of the Sun over the same period. At least one of these surge events produced a narrow CME observed in LASCO/C2. Most probably all these events are compact magnetic explosions (surges/jets, from around a small island of included polarity) which ejected cool material from lower levels. Ulysses data have been analyzed to find evidence of the cool, narrow CME events, but none or little was found. This puzzling scenario, where events seen by UVCS have no in situ counterparts and vice versa, can be partially explained once the region where the large CME originated is recognized as being at the center of the solar disk so that the CME material was actually much further from the Sun than the 1.7 Rsun height of the UVCS slit off the limb. Conversely, the narrow events may simply have missed Ulysses or been too brief for reliable signatures in composition and ionization state. A basic feature demonstrated by these observations is that large magnetic explosions produce wide-angle CMEs whereas compact magnetic explosions produce narrow CMEs. The results show that quadrature observations need some luck to be successfull: that is, events must be in the plane of the sky to allow SOHO/UVCS and Ulysses to sample the same plasma. This will most easily occur in winter 2007 and winter 2008, when the quadrature geometry will allow for prolonged observations.

Suess, Steven↗

Past and Future SOHO-Ulysses Quadratures

With the launch of SOHO, it again became possible to carry out quadrature observations. In comparison with earlier observations, the new capabilities of coronal spectroscopy with UVCS and in situ ionization state and composition with Ulysses/SWICS enabled new types of studies. Results from two studies serve as examples: (i) The acceleration profile of wind from small coronal holes. (ii) A high-coronal reconnecting current sheet as the source of high ionization state Fe in a CME at Ulysses. Generally quadrature observations last only for a few days, when Ulysses is within ca. 5 degrees of the limb. This means luck is required for the phenomenon of interest to lie along the radial direction to Ulysses. However, when Ulysses is at high southern latitude in winter 2007 and high northern latitude in winter 2008, there will be unusually favorable configurations for quadrature observations with SOHO and corresponding bracketing limb observations from STEREO A/B. Specifically, Ulysses will be within 5 degrees of the limb from December 2006 to May 2007 and within 10 degrees of the limb from December 2007 to May 2008. These long-lasting quadratures and bracketing STEREO A/B observations overcome the limitations inherent in the short observation intervals of typical quadratures. Furthermore, ionization and charge state measurements like those on Ulysses will also be made on STEREO and these will be essential for identification of CME ejecta - one of the prime objectives for STEREO.

Suess, Steven↗

Reconfigurable structure

A reconfigurable structure includes a plurality of selectively extensible and retractable limbs, at least one node pivotably receiving respective ends of at least two limbs, and an actuator associated with each limb for extending and retracting the limb. The structure may further include an addressable module associated with each actuator to control the actuator.

Curtis, Steven A.↗

EOS MLS Level 1B Data Processing Software

This software is an improvement on Version 2, which was described in EOS MLS Level 1B Data Processing, Version 2.2, NASA Tech Briefs, Vol. 33, No. 5 (May 2009), p. 34. It accepts the EOS MLS Level 0 science/engineering data, and the EOS Aura spacecraft ephemeris/attitude data, and produces calibrated instrument radiances and associated engineering and diagnostic data. This version makes the code more robust, improves calibration, provides more diagnostics outputs, defines the Galactic core more finely, and fixes the equator crossing. The Level 1 processing software manages several different tasks. It qualifies each data quantity using instrument configuration and checksum data, as well as data transmission quality flags. Statistical tests are applied for data quality and reasonableness. The instrument engineering data (e.g., voltages, currents, temperatures, and encoder angles) is calibrated by the software, and the filter channel space reference measurements are interpolated onto the times of each limb measurement with the interpolates being differenced from the measurements. Filter channel calibration target measurements are interpolated onto the times of each limb measurement, and are used to compute radiometric gain. The total signal power is determined and analyzed by each digital autocorrelator spectrometer (DACS) during each data integration. The software converts each DACS data integration from an autocorrelation measurement in the time domain into a spectral measurement in the frequency domain, and estimates separately the spectrally, smoothly varying and spectrally averaged components of the limb port signal arising from antenna emission and scattering effects. Limb radiances are also calibrated.

Perun, Vincent S.↗

Line Profile Measurements of the Lunar Exospheric Sodium

We report ongoing results of a program to measure the lunar sodium exospheric line profile from near the lunar limb out to two lunar radii (approx 3500 km). These observations are conducted from the National Solar Observatory McMath-Pierce telescope using a dual-etalon Fabry-Perot spectrometer with a resolving power of 180,600 (1.7 km/s) to measure line widths and velocity shifts of the Na D2 (5889 950 A) emission line in equatorial and polar regions at different lunar phases. The typical field of view (FOV) is 3 arcmin (approx 360 km) with an occasional smaller 1 arcmin FOV used right at the limb edge. The first data were obtained from full Moon to 3 days following full Moon (waning phase) in March 2009 as part of a demonstration run aimed at establishing techniques for a thorough study of temperatures and velocity variations in the lunar sodium exosphere. These data indicate velocity displacements from different locations off the lunar limb range between 150 and 600 m/s from the lunar rest velocity with a precision of +/- 20 to +/- 50 m/s depending on brightness. The measured Doppler line widths for observations within 10.5 arcmin of the east and south lunar limbs for observations between 5 deg and 40 deg lunar phase imply temperatures ranging decreasing from 3250 +/- 260K to 1175 +/- 150K. Additional data is now being collected on a quarterly basis since March 2011 and preliminary results will be reported.

Oliversen, Ronald J.↗

High voltage fault current limiter having immersed phase coils

A fault current limiter including: a ferromagnetic circuit formed from a ferromagnetic material and including at least a first limb, and a second limb; a saturation mechanism surrounding a limb for magnetically saturating the ferromagnetic material; a phase coil wound around a second limb; a dielectric fluid surrounding the phase coil; a gaseous atmosphere surrounding the saturation mechanism.

42 ENGINEERING↗

Percutaneous Intraluminal Recanalization of Long, Chronic Superficial Femoral and Popliteal Occlusions Using the Frontrunner XP CTO Device: A Single-Center Experience

The purpose of this study was to examine the safety and efficacy of the Frontrunner XP CTO (chronic total occlusion) Catheter (Cordis) for recanalization of long femoropopliteal artery occlusions. A Frontrunner catheter was used to treat 26 CTOs in SFA after guidewire failure (68.3 {+-} 8.8 years). Sixty-seven percent of patients had severe claudication. Critical lower limb ischemia with rest pain or minor tissue loss was present in three and eight patients, respectively. All the lesions were considered complex (TASC B, C, and D); 68% of the lesions were heavily calcified. The mean lesion length was 17.6 cm (range, 10-42 cm). The initial attempt to cross the occlusion with the CTO guidewire V18 was unsuccessful in 26 of 76 limbs (34.26%). A secondary attempt using the Frontrunner catheter (crossover approach, 27%; antegrade, 73%) performed in all 26 failed cases was successful in 17 limbs (65.38%), increasing the technical success rate to 88.12%. The main reasons for failure with the Frontrunner were inability to cross the lesion due to heavy calcification (six of nine) and inability to re-enter the true lumen after subintimal passage of the occluded segment (three of nine). The mean fluoroscopy time was 22.9 min. Minor complications included one distal extension of the dissection with involvement of the first popliteal segment and one perforation in the occluded segment. No major complications were seen. In conclusion, recanalization with the Frontrunner CTO catheter is a simple and safe method with a high technical success rate in the endovascular treatment of long superficial femoral artery occlusions and should be an alternative method after guidewire failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of 'Cutting' Balloon Angioplasty for the Treatment of Short Femoral Bifurcation Steno-Obstructive Disease

This study was designed to report our experience with 'cutting' balloon angioplasty (CBA) for the treatment of short femoral bifurcation arterial stenosis. Between March 2005 and September 2007, 18 consecutive patients who were high-risk for surgery with critical limb ischemia or severe lifestyle-limiting claudication underwent 'cutting' balloon angioplasty (4-6 mm diameter/15-20-mm length) for the treatment of 27 focal (<3 cm) severe fibro-calcified stenosis of the common femoral artery (n = 14) and/or the proximal part of the superficial femoral artery (n = 6) or profunda femoris (n = 7). Baseline patient demographic data, pre- and post-procedural patient clinical data, and procedural results were recorded. Follow-up consisted of clinical check-up and color duplex ultrasonography (CDU) examination 1, 3, 6, 12, and 18 months after the procedure. All endovascular treatments were successfully performed with clinical success obtained for all patients. No complications occurred during all treatments and no patient required surgical conversion or placement of a stent because of recoil, dissection, or arterial tears. No acute vessel closure was registered. During a mean follow-up of 9.4 (range, 6-18) months, endovascular treatment (CBA) was performed for restenosis/occlusion of seven lesions (25.9%) in four patients, whereas surgical treatment (endarterectomy with patch) for restenosis/occlusion of three lesions (11.1%) was performed in two patients with a consequent reintervention rate of 37%. Primary and secondary patency rates were 84.6 and 88.4% at 6 months and 57.9 and 79.6% at 12 months, respectively. No major limb amputation was performed, with a 12-month limb salvage rate of 88.9%. CBA seems to be a valuable tool for the endovascular treatment of focal femoral bifurcation stenotic lesions for patients who are poor candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PTA of Infrapopliteal Arteries: Long-term Clinical Follow-up and Analysis of Factors Influencing Clinical Outcome

This study was a retrospective analysis of patients with CLI who underwent infrapopliteal percutaneous transluminal angioplasty (PTA). The main goal was to evaluate clinical and morphological factors that influence the clinical outcome of PTA in long-term follow-up. A total of 1,445 PTA procedures were performed in 1,268 patients. Main indications for PTA included gangrene, nonhealing ulcers, or rest pain. The mean number of treated arteries was 1.77 artery/limb, and the majority of lesions were type TASC D. The technical success rate of PTA was 89% of intended-to-treat arteries. The main criterion of clinical success was functional limb salvage (LS). One-year follow-up involved 1,069 limbs. Primary and secondary 1-year LS rates were 76.1 and 84.4%, respectively. The effect of clinical and morphological parameters on the 1-year LS was that the only associated disease with an adverse effect on LS rate was DM combined with dialysis. Regarding limb preprocedural status, gangrene was clearly a negative predictor. The most important factor affecting LS was the number of patent arteries post-PTA: patients with 0, 1, 2, and 3 patent arteries had 1-year primary LS rates of 56.4, 73.1, 80.4, and 83%, respectively. Long-term follow-up of LS rates demonstrated secondary LS rates of 84.4, 78.8, and 73.3% at 1, 5, and 10 years. Every effort should be made to perform PTA for as many arteries as possible, even if TASC D type, to improve clinical outcome. Our study shows that repeat PTA is capable of keeping the long-term LS rate close to 75%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subintimal Recanalization of Occluded Stents: The Substent Technique

PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan-Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 {+-} 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 {+-} 90.78 mm. The mean occluded stented segment length was 90.21 {+-} 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year's follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few alternatives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Recanalization of Thromboangiitis Obliterans (Buerger’s Disease) in Twenty-Eight Consecutive Patients and Combined Antegrade–Retrograde Intervention in Eight Patients

Purpose: The aim of the study was to evaluate the technical success of the procedure and the clinical efficacy of treatment in patients with thromboangiitis obliterans (TAO) (Buerger’s disease) based on a change in the Rutherford classification. Materials and Methods: A total of 28 consecutive patients (26 males, 2 females, mean age 43.3 ± 5.32 years) underwent endovascular recanalization with a diagnosis of TAO, between April 2015 and July 2018. After unsuccessful attempts using the antegrade approach, retrograde approaches were used in 8 patients under ultrasound guidance. Clinical follow-up was routinely performed at 1-month, 3-month, 6-month, and 1-year intervals. Results: A total of 28 TAO patients underwent 40 procedures in 32 limbs. Technical success was achieved in 28 of the 32 limbs (87.5%). In total, 45 of 59 (76.2%) below the knee arteries were treated successfully. One major amputation was performed, providing a 96.8% rate for limb salvage both at 12 and 24 months. Amputation-free survival estimated by Kaplan–Meier analysis was 84% at 12 and 24 months. Primary patency rates at 12, 24, and 36 months were 84%, 78%, and 75%, respectively. Secondary patency rates were 87.5% both at 12 and 24 months. Conclusion: Endovascular treatment is a technically feasible and potentially effective treatment modality for Buerger’s disease. Combined antegrade and retrograde interventions in TAO patients may improve technical success and clinical recovery, especially in cases where the antegrade approach has failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recurrence Patterns and Survival for Patients With Intermediate- and High-Grade Myxofibrosarcoma

Purpose: Myxofibrosarcoma (MFS) is a rare sarcoma with a predilection for multiple local recurrences (LR), for which optimal treatment has not been defined. We reviewed our experience to determine the impact of surgery and radiation therapy (RT) on pattern of recurrence, limb salvage, and overall survival (OS). Methods and Materials: Between 1995 and 2005, 36 patients with localized intermediate- or high-grade MFS were treated at our institution. Data on clinicopathologic features, treatments, and patient outcomes were reviewed and analyzed. Results: Median age was 72.5 years (range, 42-96 years). Median tumor size was 7.5 cm, and 34 tumors (94%) were high grade. All patients underwent surgery at our institution, including re-resections in 20 patients (56%) after initial surgery elsewhere. Margins were microscopically positive in 9 patients (25%). RT was given to 28 patients (78%) pre - and/or postoperatively. After a median follow-up of 3.5 years (range, 0.4-12.4 years), 11 patients (31%) developed LR. There were no significant predictors for LR on univariate analysis, including margin status or use of RT. Limb salvage was ultimately achieved in only 5 of 11 LRs (45%) because of multiple subsequent LRs. Distant recurrence (DR) occurred in 6 patients (17%). Median and 4-year OS were 96 months and 65%, respectively. Seven patients (19%) died of tumor-related causes, 6 of whom had DRs. On univariate analysis, tumor size was associated with OS. Conclusions: Despite aggressive surgery and RT, intermediate- and high-grade MFS are associated with a high rate of LR that adversely affects limb preservation. More aggressive local treatment strategies are necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗