Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

The Physics Analysis of a Gas Attenuator with Argon as a Working Gas

A gas attenuator is an important element of the LCLS facility. The attenuator must operate in a broad range of x-ray energies, provide attenuation coefficient between 1 and 10{sup 4} with the accuracy of 1% and, at the same time, be reliable and allow for many months of un-interrupted operation. S. Shen has recently carried out a detailed design study of the attenuator based on the use of nitrogen as a working gas. In this note we assess the features of the attenuator based on the use of argon. We concentrate on the physics issues, not the design features.

43 PARTICLE ACCELERATORS↗

Direct Comparison of Brookhaven Reflectivity Measurements with Free-Electron Theory

The reflectivity at normal incidence of copper and aluminum samples was recently measured over a large frequency range at Brookhaven by one of us (JT). Then using the Kramers-Kroning integrals, and assuming the free-electron model of conductivity, the dependence of conductivity on frequency was obtained. The results seemed to suggest, for example, that the dc conductivities of the copper and evaporated aluminum samples are a factor of 3 lower than expected. We propose in this report, instead, directly fitting the free-electron model to the low frequency end of the reflectivity data. This fitting does not depend on the higher frequency results and on Kramers-Kronig integrations, but it does assume that the data at the low frequency end is sufficiently accurate. Note that for our LCLS wakefield studies, it is only over these (relatively) low frequencies that we need to know the electrical properties of the metals. The equations that relate reflectivity R with the free electron parameters dc conductivity {sigma} and relaxation time {tau} are: (1) {tilde {sigma}} = {sigma}/1-ikc{tau}; (2) {tilde n} = {radical} {tilde {epsilon}} = {radical}(1+4{pi}i{tilde k}c/{omega}); and (3) R = |{tilde n}-1/{tilde n} + 1|{sup 2}. The parameters are ac conductivity {tilde {sigma}}, index of refraction {tilde n}, dielectric constant {tilde {epsilon}}, and wave number k = {omega}/c, with {omega} frequency and c the speed of light. In Fig. 1 we show the ideal behavior of R for a reasonably good conducting metal, where {sigma} = 0.12 x 10{sup 17}/s and {tau} = 0.55 x 10{sup -14} s (solid line); these parameters are, respectively, 2% ({sigma}) and 20% ({tau}) of the nominal values for copper. The parameters were chosen so that the important features of R(k) could be seen easily in one plot. We see 3 distinct regions: (1) for low frequencies, k {approx}< 1/c{tau}, R continually decreases, with positive curvature, and with a low frequency asymptote of (1 - {radical}2kc/{pi}{sigma}); (2) for intermediate frequencies the reflectivity is nearly constant, R {approx} (1 - {radical}1/{pi}{sigma}{tau}); (3) for k {approx}> k{sub p} = {radical}4{pi}{sigma}/c{sup 2}{tau}, the plasma frequency of the metal, R quickly drops to zero. The dashed lines in Fig. 1 give the analytic guideposts for the 3 regions. Note that it is only in the first and part of the second region that we can expect the free electron model to have validity in real metals; at higher frequencies the effects of absorption bands and other physics will distort the R(k) curve. In principle, knowing R accurately in the entire 1st region suffices for obtaining the free-electron parameters {sigma} and {tau}; in practice, however, knowing it also in the 2nd region gives us more confidence in the model and especially in the value of {tau}.

36 MATERIALS SCIENCE↗

Wakefield Calculations for Radiation Stopper 1 (RST1)

The main result of this note is that no wakefield mitigation is required for the Radiation Stopper (RST1) in the LCLS injector. The RST1 geometry is not symmetric in the vertical direction, and we derive a slight modification to the diffraction model wake for a cylindrically symmetric (2D) cavity that can be used for this problem. Performing a full 3D MAFIA calculation for the nominal 1 mm (rms) long bunch, we show that the modified diffraction model well describes the wakefields generated in RST1. The results imply an on-axis emittance growth of 0.0075%, well below the 0.5% tolerance threshold. To reach the 0.5% threshold the beam would need to be mis-steered by a large amount - 7 mm - from the axis. One reason that the effect is small is that the beta functions at the RST1 are small.

43 PARTICLE ACCELERATORS↗

Wakefield Computations for the Injector (Part I)

In this document, we report on basic wakefield computations used to establish the impedance budget for the LCLS injector. Systematic comparisons between analytic formulae and results from ABCI are done. Finally, a comparison between 2D and 3D wakefield calculations are given for a cross. The three parts of the document are presented as follows: (1) ABCI computations for a few structures (Flange, Bellows...); (2) Comparison analytic with ABCI runs; and (3) Comparison Cross and Cavity using MAFIA.

43 PARTICLE ACCELERATORS↗

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.

43 PARTICLE ACCELERATORS↗

Using SciDB to Support Photon Science Data Analysis

Array data analytic systems like SciDB hold great potential to accelerate processing data from SLAC's Linac Coherent Light Source and other experiments. SciDB is unique in its ability to integrate storage and processing of array data efficiently, providing both space-efficient storage and out-of-memory efficient parallel array processing. We describe a recent effort to leverage SciDB to store and process LCLS data. The work includes development of software to import data into SciDB, subsequent benchmarks, and interactive manipulation of data in SciDB.

43 PARTICLE ACCELERATORS↗

Much Ado about Microbunching: Coherent Bunching in High Brightness Electron Beams

The push to provide ever brighter coherent radiation sources has led to the creation of correspondingly bright electron beams. With billions of electrons packed into normalized emittances (phase space) below one micron, collective effects may dominate both the preservation and use of such ultra-bright beams. An important class of collective effects is due to density modulations within the bunch, or microbunching. Microbunching may be deleterious, as in the case of the Microbunching Instability (MBI), or it may drive radiation sources of unprecedented intensity, as in the case of Free Electron Lasers (FELs). In this work we begin by describing models of microbunching due to inherent beam shot noise, which sparks both the MBI as well as SLAC's Linac Coherent Light Source, the world's first hard X-ray laser. We first use this model to propose a mechanism for reducing the inherent beam shot noise as well as for predicting MBI effects. We then describe experimental measurements of the resulting microbunching at LCLS, including optical radiation from the MBI, as well as the first gain length and harmonic measurements from a hard X-ray FEL. In the final chapters, we describe schemes that use external laser modulations to microbunch light sources of the future. In these sections we describe coherent light source schemes for both both linacs and storage rings.

43 PARTICLE ACCELERATORS↗

Simulations and Analysis of an Infrared Prism Spectrometer for Ultra-short Bunch Length Diagnostics at the Linac Coherent Light Source

We require a means of determining the minimum achievable bunch length at the Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory. Current methods of measurement in the time domain do not have the resolution to measure ultra-short bunch lengths below 10 fs. An alternative method has been designed, using a single-shot near- to mid-infrared prism spectrometer for bunch length diagnosis in the frequency domain. This design requires the precision alignment of sensitive optical equipment and complete understanding of the spectrum reaching the spectrometer's detector surface. This paper provides information on preliminary simulations designed to model beam behavior in the optical set-up and at the detector surface for comparison to measured values as an indication of the current achievable optical alignment and the study of optimal detector orientation. The results of these simulations indicate the necessity for a method of greater precision in optical alignment and further study of achievable spectrometer range!

OTHER↗

Optical Design of a Broadband Infrared Spectrometer for Bunch Length Measurement at the Linac Coherent Light Source

The electron pulses generated by the Linac Coherent Light Source at the SLAC National Accelerator Laboratory occur on the order of tens of femtoseconds and cannot be directly measured by conventional means. The length of the pulses can instead be reconstructed by measuring the spectrum of optical transition radiation emitted by the electrons as they move toward a conducting foil. Because the emitted radiation occurs in the mid-infrared from 0.6 to 30 microns a novel optical layout is required. Using a helium-neon laser with wavelength 633 nm, a series of gold-coated off-axis parabolic mirrors were positioned to direct a beam through a zinc selenide prism and to a focus at a CCD camera for imaging. Constructing this layout revealed a number of novel techniques for reducing the aberrations introduced into the system by the off—axis parabolic mirrors. The beam had a recorded radius of less than a millimeter at its final focus on the CCD imager. This preliminary setup serves as a model for the spectrometer that will ultimately measure the LCLS electron pulse duration.

43 PARTICLE ACCELERATORS↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

Meeting Report: User Workshop on High-Power Lasers at the Linac Coherent Light Source

A two-day international workshop on the physics and integration of high-power lasers with the Linac Coherent Light Source was held in Stanford, USA, on October 1-2, 2013. The workshop was co-organized by UC Berkeley, Lawrence Berkeley, Lawrence Livermore and SLAC National Accelerator Laboratories. More than 150 scientists, including 30 students and postdocs who are working in high-intensity laser-matter interactions, fusion research, and dynamic high-pressure science came together from North America, Europe and Asia. The group discussed the most promising and important new physics experiments that will be enabled by the unique combination of high-power lasers with the world-class LCLS freeelectron laser X-ray beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast Structural Dynamics in Combustion Relevant Model Systems

The research project explored the time resolved structural dynamics of important model reaction system using an array of novel methods that were developed specifically for this purpose. They include time resolved electron diffraction, time resolved relativistic electron diffraction, and time resolved Rydberg fingerprint spectroscopy. Toward the end of the funding period, we also developed time-resolved x-ray diffraction, which uses ultrafast x-ray pulses at LCLS. Those experiments are just now blossoming, as the funding period expired. In the following, the time resolved Rydberg Fingerprint Spectroscopy is discussed in some detail, as it has been a very productive method. The binding energy of an electron in a Rydberg state, that is, the energy difference between the Rydberg level and the ground state of the molecular ion, has been found to be a uniquely powerful tool to characterize the molecular structure. To rationalize the structure sensitivity we invoke a picture from electron diffraction: when it passes the molecular ion core, the Rydberg electron experiences a phase shift compared to an electron in a hydrogen atom. This phase shift requires an adjustment of the binding energy of the electron, which is measurable. As in electron diffraction, the phase shift depends on the molecular, geometrical structure, so that a measurement of the electron binding energy can be interpreted as a measurement of the molecule’s structure.

99 GENERAL AND MISCELLANEOUS↗

SLAC Disk Loaded Waveguide (DLWG) Accelerator Structure

This drawing package is for the SLAC s-band DLWG accelerator structures used in the original linac. These structures are still operating to this day serving in the SLAC LCLS-I and FACET linacs. For access to the drawings, contact the SLAC Office of Research Partnerships & Technology Commercialization (IPRP@slac.stanford.edu).

Tremaine, Aaron↗

XL4 Klystron (Top level drawing AD-700-924-00)

This drawing package is for the SLAC XL4 x-band pulsed klystron that was originally developed as a source for high gradient accelerator structures for the Next Linear Collider project. This device has proven to be a very useful source for driving a variety of high gradient breakdown experiments to linearizer and deflector structures instrumental to the LCLS operation. This klystron operates at a frequency of 11.424 GHz and produces a peak output power of 50 MW with a pulse length of 1.5 {mu}s at 60 Hz pulse repetition rate.

Tremaine, Aaron↗

5045 Klystron (Top level drawing AD-700-870-00)

This drawing package is for the SLAC 5045 s-band pulsed klystron that was designed to power the SLAC Linear Collider. It is currently powering the SLAC LCLS and FACET linear accelerators. This klystron operates at a frequency of 2.856 GHz and produces a peak output power of 67 MW with a pulse length of 3.5 {mu}s at 180 Hz pulse repetition rate.

Tremaine, Aaron↗

The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser

This is the final report for the DoE BES contract DE-FG02-07ER46272. This grant began under a title that gives its history in a few words: The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser. At the time of adopting this name, the UCLA Particle Beam Physics Laboratory (PBPL) was at the forefront of the first demonstrations of SASE FEL, giving the experimental basis for the 4th generation X-ray light source now exemplified by the LCLS, a remarkable generation of machines that have revolutionize nanoscale and ultrafast science. The grant title indicates that physical aspects of the FEL are of interest, and implies that progress requires comprehensive investigations. These aspects include: the physics and technology of high brightness electron beam generation, phase space manipulations, advanced beam diagnostics, state-of-the-art undulators, studies of FEL mode characteristics, as well as the introduction of new theoretical models and start-to-end simulations, all yielding a deep understanding of the SASE FEL. The latest period (2010-13) of BES grant support has been the most productive yet for the UCLA PBPL, and the extensive list of accomplishments is illustrative of our central contributions to advanced FEL research. We give a concise overview here and review our research results in further detail below. In FEL and ultrafast beam physics, we have experimentally investigated: production of helical beams and FEL modes with orbital angular momentum; chirp-taper single-spike FEL gain; new FROG techniques optimized for FEL, introduced coherent imaging of beam profiles using transition radiation; and demonstrated a next generation cryoundulator. We have performed deep theoretical studies of these phenomena and other advanced FEL physics concepts, such as the space-charge amplifier. In high brightness beams, we have: introduced a new class of hybrid photoinjector for <100 fs beam production; developed new approaches to self-shaped ellipsoidal beams; used nonlinear plasma oscillations to create beam pulse trains; tested new plasmonic, high quantum efficiency cathodes, and developed new methods of beam measurement with um spatial/sub-fs temporal resolution. In ultrafast imaging, we have: developed advanced electro-optic timing systems, performed the 1st pump-probe study using single shot UED, demonstrated continuously time-resolved UED with RF deflection; made initial use of inverse Compton scattering (ICS) X-ray sources in application through single-shot inline phase contrast imaging, established single-shot X-ray diffraction, and observed ICS high harmonic generation and redshifting due to nonlinear effects. In 5th generation light source research, we have developed the techniques of narrowband, very high power coherent Cerenkov radiation sources based on dielectric wakefield devices. This work is represented by numerous publications in leading journals: e.g. Nature Physics, Physical Review Letters, Applied Physics Letters. The PBPL program’s influence on the field also extends to organization of the electron beam applications community; we have organized the first international UED workshops and the initial two meetings dedicated to 5th generation light source.

43 PARTICLE ACCELERATORS↗

Novel Multiple-Gigahertz Electron Beams for Advanced X-Ray and Gamma-Ray Light Sources

Current and future generations of advanced light sources largely depend on high brightness electron beams. LLNL has spent the past decade developing Mono-Energetic Gamma-ray (MEGa-ray) sources by scattering laser light off an electron beam for nuclear physics applications. At the SLAC National Accelerator Laboratory, the Linac Coherent Light Source (LCLS) is generating extraordinarily high peak brightness x-ray beams useful for biological, chemical, and physics studies by passing a 13.6 GeV electron beam through a series of magnetic undulators to form a Free-Electron Laser (FEL). Los Alamos is in the process developing the “MaRIE” (Matter-Radiation Interactions in Extremes) concept, which will also rely on FELs. All these light sources would benefit from improved average brightness by increasing the repetition rate of the electron beam source. Since the undulators are based on permanent magnets, they will generate x-rays from as many electron bunches as can be delivered. Similarly, for MEGa-ray sources very little laser light is scattered from each individual electron bunch. If there are additional electron bunches to see the laser, they will also scatter photons, generating more gamma-rays. Modeling has shown that using trains of hundreds of electron bunches allows high gamma-ray fluxes to be generated using ns-long scattering laser pulses. This means that chirped pulse amplification would not be needed for the interaction laser, considerably simplifying the architecture. This would also allow for lower laser bandwidth at the interaction point, along with a larger focal spot size, eliminating the laser contribution to the scattered gamma-ray bandwidth. Additionally, lower charge per bunch allows more flexibility in the transport, simplifying efforts to mitigate noise-inducing dark current. The overarching goal of the proposed research is to develop and demonstrate the required technology to generate multi-GHz rep-rate electron beams at pC-scale bunch charges to allow 100x increases in the average beam current. To achieve this, the project consisted of two major efforts: 1. Demonstration of a photocathode drive laser capable of generating the electron beam. 2. Commissioning of an x-band accelerator to enable studies of inter-bunch electromagnetic field interactions. Excellent results were achieved in both areas.

42 ENGINEERING↗

Probing Warm Dense Silica with Betatron Radiation - Oral Presentation [Slides]

Laser wakefield acceleration (LWFA) has been shown to produce short X-ray pulses from oscillations of electrons within the plasma wake. These betatron X-rays pulses have a broad, synchrotron-like energy spectrum and a duration on the order of the driving laser pulse, thereby enabling probing of ultrafast interactions. Using the 1 J, 40fs short-pulse laser at the Matter in Extreme Conditions experimental station at LCLS, we have implemented LWFA to generate and subsequently characterized betatron X-rays. A scintillator and lanex screen were used to measure the charge fluence and energy spectrum of the produced electron beam.

43 PARTICLE ACCELERATORS↗