Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Data centers as dispatchable loads to harness stranded power

Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast, optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.

97 MATHEMATICS AND COMPUTING↗

Nailing the Peak: City-Scale, Building-Specific Load Factor and Contribution to a Utility’s Hour of Critical Generation

Maintaining electrical generation assets to meet peak demand increases the cost of providing electricity to a country’s buildings and insufficient assets can result in power outages. In order to keep reliable electricity costs low for consumers and demand charges low for utilities, there exist markets and financial incentives for limiting consumption during peak demand.The team has partnered with an electrical distributor servicing a 1,390 km2 area and 178,368 buildings with the aim of using urban-scale building energy modelling to inform business decisions necessary for the operation of their electric grid. A suite of software has been developed that allows the scalable creation of a “digital twin” for all buildings in the utility’s service area. This virtual utility area is analysed for targeted deployment of new technologies or policies to assess building-specific savings, effects on critically-loaded grid infrastructure (e.g. feeders, substations), and aggregated impact to utility-scale operations.This work leverages 15-minute data from each building to compare actual and simulated monthly peak-hour demand and assessment of the load factor for each building. Findings include market characterization via clustering of relative energy use profiles for ~180,000 buildings as well as simulation-informed savings opportunities indicating residential load factors of 0.17, commercial load factors of 0.2-0.4 depending on year of construction, and general load factors of 0.16-0.5 depending on building type.

New, Joshua↗

An integrative modeling framework to evaluate the productivity and sustainability of biofuel crop production systems

The potential expansion of biofuel production raises food, energy, and environmental challenges that require careful assessment of the impact of biofuel production on greenhouse gas (GHG) emissions, soil erosion, nutrient loading, and water quality. In this study, we describe a spatially explicit integrative modeling framework (SEIMF) to understand and quantify the environmental impacts of different biomass cropping systems. This SEIMF consists of three major components: (1) a geographic information system (GIS)-based data analysis system to define spatial modeling units with resolution of 56 m to address spatial variability, (2) the biophysical and biogeochemical model Environmental Policy Integrated Climate (EPIC) applied in a spatially-explicit way to predict biomass yield, GHG emissions, and other environmental impacts of different biofuel crops production systems, and (3) an evolutionary multiobjective optimization algorithm for exploring the trade-offs between biofuel energy production and unintended ecosystem-service responses. Simple examples illustrate the major functions of the SEIMF when applied to a nine-county Regional Intensive Modeling Area (RIMA) in SW Michigan to (1) simulate biofuel crop production, (2) compare impacts of management practices and local ecosystem settings, and (3) optimize the spatial configuration of different biofuel production systems by balancing energy production and other ecosystem-service variables. Potential applications of the SEIMF to support life cycle analysis and provide information on biodiversity evaluation and marginal-land identification are also discussed. The SEIMF developed in this study is expected to provide a useful tool for scientists and decision makers to understand sustainability issues associated with the production of biofuels at local, regional, and national scales.

bioenergy↗

2010 Annual Wastewater Reuse Report for the Idaho National Laboratory Site's Central Facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2009, through October 31, 2010. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of special compliance conditions • Discussion of the facility’s environmental impacts. During the 2010 permit year, approximately 2.2 million gallons of treated wastewater was land-applied to the irrigation area at Central Facilities Area Sewage Treatment plant.

99 GENERAL AND MISCELLANEOUS↗

Preparation and characterization of reactive blends of poly(lactic acid), poly(ethylene-co-vinyl alcohol), and poly(ethylene-co-glycidyl methacrylate)

The ternary blends of poly(lactic acid) (PLA), poly(ethylene-co-vinyl alcohol) (EVOH), and poly(ethylene-co-glycidyl methacrylate) (EGMA) were prepared. The role of EGMA as a compatibilizer was evaluated. The weight ratio of PLA:EVOH was 80:20 and the EGMA loadings were varied from 5-20 phr. The blends were characterized as follows: thermal properties by differential scanning calorimetry, morphology by scanning electron microscopy, and mechanical properties by pendulum impact tester, and universal testing machine. The glass transition temperature of PLA blends did not change much when compared with that of PLA. The blends of PLA/EGMA and EVOH/EGMA showed EGMA dispersed droplets where the latter led to poor impact properties. However, the tensile elongation at break and tensile toughness substantially increased upon addition of EGMA to blends of PLA and EVOH. It was noted in tensile test samples that both PLA and EVOH domains fibrillated significantly to produce toughness.

36 MATERIALS SCIENCE↗

On the dynamic tensile strength of an FCC metal

The tensile response of ductile, polycrystalline metals is often accompanied by the formation of pores within the material, which coalesce and fail a plane within a metal. This large deformation process is broadly progressive, with a physical path consisting of nucleation, growth, coalescence, and failure, which occur individually over short periods of time. Thus distinct micro-mechanisms operate, each influenced by microstructure, loading path, and loading profile, which remains a significant challenge to represent and predict numerically at the macroscale. In a previous study, the influence of loading path on damage evolution in high-purity tantalum has been presented; in this paper, complimentary measurements are made on a pure, FCC copper. Samples were shock loaded to three different peak stresses using both symmetric impact, and two different composite flyer plate configurations, such that upon unloading, the three samples were subject to nearly identical tensile loading. The damage evolution in the soft-recovered copper samples was then quantified using optical metallography and electron-back-scatter diffraction. We shall compare metallurgical observations, velocimetry histories and simulations to discuss the dynamic failure mechanics observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Operational Impacts of Wind Energy Resources in the Bonneville Power Administration Control Area - Phase I Report

This report presents a methodology developed to study the future impact of wind on BPA power system load following and regulation requirements. The methodology uses historical data and stochastic processes to simulate the load balancing processes in the BPA power system, by mimicking the actual power system operations. Therefore, the results are close to reality, yet the study based on this methodology is convenient to conduct. Compared with the proposed methodology, existing methodologies for doing similar analysis include dispatch model simulation and standard deviation evaluation on load and wind data. Dispatch model simulation is constrained by the design of the dispatch program, and standard deviation evaluation is artificial in separating the load following and regulation requirements, both of which usually do not reflect actual operational practice. The methodology used in this study provides not only capacity requirement information, it also analyzes the ramp rate requirements for system load following and regulation processes. The ramp rate data can be used to evaluate generator response/maneuverability requirements, which is another necessary capability of the generation fleet for the smooth integration of wind energy. The study results are presented in an innovative way such that the increased generation capacity or ramp requirements are compared for two different years, across 24 hours a day. Therefore, the impact of different levels of wind energy on generation requirements at different times can be easily visualized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climate change is projected to have severe impacts on the frequency and intensity of peak electricity demand across the United States

Significance The existing empirical literature on the impacts of climate change on the electricity sector has focused on changing electricity consumption patterns. In this paper, we show that incorporating impacts on the frequency and intensity of peak load consumption during hot days implies sizable required investments in peak generating capacity (or major advances in storage technology or the structure of electricity prices), which results in substantially larger impacts than those from just changes in overall consumption.

Auffhammer, Maximilian↗

Development of a Dynamic Model and Control System for Load-Following Studies of Supercritical Pulverized Coal Power Plants

Traditional energy production plants are increasingly forced to cycle their load and operate under low-load conditions in response to growth in intermittent renewable generation. A plant-wide dynamic model of a supercritical pulverized coal (SCPC) power plant has been developed in the Aspen Plus Dynamics® (APD) software environment and the impact of advanced control strategies on the transient responses of the key variables to load-following operation and disturbances can be studied. Models of various key unit operations, such as the steam turbine, are developed in Aspen Custom Modeler® (ACM) and integrated in the APD environment. A coordinated control system (CCS) is developed above the regulatory control layer. Three control configurations are evaluated for the control of the main steam; the reheat steam temperature is also controlled. For studying servo control performance of the CCS, the load is decreased from 100% to 40% at a ramp rate of 3% load per min. The impact of a disturbance due to a change in the coal feed composition is also studied. The CCS is found to yield satisfactory performance for both servo control and disturbance rejection.

20 FOSSIL-FUELED POWER PLANTS↗

Viral Load Kinetics of Severe Acute Respiratory Syndrome Coronavirus 2 in Hospitalized Individuals With Coronavirus Disease 2019

Abstract Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) kinetics remain understudied, including the impact of remdesivir. In hospitalized individuals, peak sputum viral load occurred in week 2 of symptoms, whereas viremia peaked within 1 week of symptom-onset, suggesting early systemic seeding of SARS-CoV-2. Remdesivir treatment was associated with faster viral decay.

60 APPLIED LIFE SCIENCES↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Investigation of Passive and Semi-Active Tuned Mass Dampers for a Tension Leg Platform Floating Offshore Wind Turbine in ULS Conditions

Offshore Wind Turbines (OWTs) are subjected to complex external loadings caused by combined wind and wave sources. The application of structural damping control techniques to OWTs using Tuned Mass Dampers (TMDs) has shown to be effective in reducing the integrated system loads and accelerations. In this work, the impact of passive and semi-active (S-A) TMD’s applied to both fixed-bottom (monopile) and floating (tension leg platform) OWTs are evaluated under the Fatigue Limit State (FLS) and Ultimate Limit State (ULS). Different S-A control logics like ON/OFF state damping based on the ground hook (GH) control policy are implemented, and the frequency response of each algorithm is investigated. It is shown that the performance of each algorithm varies according to the load conditions such as FLS (normal operation) and ULS (idling state). Fully-coupled time domain simulations are conducted through the developed simulation tool for structural control integrated into the high-fidelity wind turbine design code, FASTv8. Compared to the passive TMD, it is shown that a S-A TMD results in higher load reductions, as well as, smaller strokes under both FLS and ULS conditions. In FLS analysis, the S-A TMD using Displacement Based Ground Hook (DB-GH) control is capable of reducing the fore-aft and side-to-side damage equivalent loads for the monopile substructure by approximately 12 % and 64 %, respectively. The ultimate loads at the tower base for the floating substructure (TLP) are also reduced by 9% with S-A TMD followed by Inverse Velocity Based Ground Hook control (IVB-GH). The dynamic characteristics and practical feasibility of a magnetorheological (MR) damper (for S-A control) are also evaluated.

17 WIND ENERGY↗

Multiphysics simulation of supercritical CO 2 gasification for hydrogen production

A bench-scale supercritical CO 2 gasifier is being considered by the U.S. Department of Energy’s National Energy Technology Laboratory (NETL). A reacting computational fluid dynamics (CFD) model was developed using ANSYS/Fluent in order to investigate the impact of various operating parameters on syngas composition. The model was validated using available data in the literature. Simulations were conducted over a range of coal-slurry loadings, reaction temperatures, system pressures, and oxygen mass flowrates with the goal of optimizing hydrogen production for the considered reactor. The results from the simulations identified a positive correlation between slurry loading and hydrogen production, while reactor temperature and pressure had a limited impact on H 2 production at the conditions of interest. Additionally, the simulations indicated that oxygen mass flowrate has less of an impact on hydrogen production at higher slurry loadings.

08 HYDROGEN↗

Multiphysics Simulation of Supercritical CO2 Gasification for Hydrogen Production

A bench-scale supercritical CO2 gasifier is being considered by the U.S. Department of Energy’s National Energy Technology Laboratory (NETL). A reacting computational fluid dynamics (CFD) model was developed using ANSYS/Fluent in order to investigate the impact of various operating parameters on syngas composition. The model was validated using available data in the literature. Simulations were conducted over a range of coal-slurry loadings, reaction temperatures, system pressures, and oxygen mass flowrates with the goal of optimizing hydrogen production for the considered reactor. The results from the simulations identified a positive correlation between slurry loading and hydrogen production, while reactor temperature and pressure had a limited impact on H2 production at the conditions of interest. Additionally, the simulations indicated that oxygen mass flowrate has less of an impact on hydrogen production at higher slurry loadings.

Prlina, Alexander↗

Aerodynamic Analysis of Wind Loading on Parabolic Trough Collectors Using High-Fidelity CFD Modeling

Wind loading on parabolic solar collector support structures is the key driver for material costs. As identified by NREL's CSP Best Practices project [1], ability to predict wind-loading in deep-arrays and the impact of edge effects has potential to decrease levelized cost of electricity (LCoE) by 15%. In this study, we present a high-fidelity computational model that can model the flow around deep arrays of parabolic troughs under varying turbulent inflow conditions. Ability to accurately reproduce atmospheric boundary layer (ABL) profiles is first demonstrated through Large Eddy Simulation (LES) simulations and compared against wind tunnel measurements. Thereafter, unsteady turbulent flow past single row and six row configurations is computed using hybrid RANS/LES simulations. Investigations of wind loading, through parametric tilt angle variations of single row and on waked collectors in six-row configuration, are used to highlight design considerations for parabolic troughs only possible through high-fidelity unsteady calculations.

aerodynamics↗

Impact Assessment of Plug-In Hybrid Vehicles on Pacific Northwest Distribution Systems

The U.S. electric power infrastructure is a significantly underutilized strategic asset which, with the proper shift in operational paradigms, could provide a significant portion of the energy requirements for the existing light duty vehicle (LDV) fleet. This shift would result in reduced emissions, improved economics for utilities, and a reduced dependence on oil. A previous study has shown that the existing generation and transmission assets of the electric power infrastructure could feasibly supply the electricity for about 70% of the U.S. LDV fleet [1]. The limitations of the distribution system were not explicitly addressed and are more difficult to quantify because of the large diversity of distribution systems topology, design guidelines and load growth. This paper focuses on the impacts of a high penetration of Plug-In Electric Hybrid Vehicles (PHEVs) on the distribution systems. Presented are results specific for the Pacific Northwest.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Probabilistic impact of electricity tariffs on distribution grids considering adoption of solar and storage technologies

This study models the role of electricity tariffs on the long-term adoption of photovoltaic and storage technologies as well as the consequent impact on the distribution grid. An adoption model that captures the economic rationality of tariff-driven investments and considers the stochastic nature of individual consumers’ decisions is proposed. This model is then combined with a probabilistic load flow to evaluate the long-term impacts of the adoption on the voltage profiles of the distribution grid. To illustrate the methodology, different components of the electricity tariffs, including solar compensation mechanisms and time differentiation of Time-of-Use (ToU) rates, are evaluated, using a case study involving a section of a medium-voltage network with 118 nodes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Rate Dependent Multi-Mechanism Discharge of Ag 0.50 VOP 4 ·1.8H 2 O: Insights from In Situ Energy Dispersive X-ray Diffraction

Ag 0.50 VOPO 4 ·1.8H 2 O (silver vanadium phosphate, SVOP) demonstrates a counterintuitive higher initial loaded voltage under higher discharge current. Energy dispersive X-ray diffraction (EDXRD) from synchrotron radiation was used to create tomographic profiles of cathodes at various depths of discharge for two discharge rates. SVOP displays two reduction mechanisms, reduction of a vanadium center accompanied by lithiation of the structure, or reduction-displacement of a silver cation to form silver metal. In-situ EDXRD provides the opportunity to observe spatially resolved changes to the parent SVOP crystal and formation of Ag 0 during reduction. At a C/170 discharge rate V 5+ reduction is the preferred initial reaction resulting in higher initial loaded voltage. At a discharge rate of C/400 reduction of Ag + with formation of conductive Ag 0 occurs earlier during discharge. Discharge rate also affects the spatial location of reduction products. The faster discharge rate initiates reduction close to the current collector with non-uniform distribution of silver metal resulting in isolated cathode areas. The slower rate develops a more homogenous distribution of reduced SVOP and silver metal. This study illuminates the roles of electronic and ionic conductivity limitations within a cathode at the mesoscale and how they impact the course of reduction processes and loaded voltage.

25 ENERGY STORAGE↗